Data / Medical devices / United States / Baxter Healthcare Corporation
Baxter Healthcare Corporation: FDA-registered device maker in Round Lake, IL, United States, 106 510(k) clearances and 6 PMA approvals
Baxter Healthcare Corporation is registered with the FDA (registration 1416980) in Round Lake, IL, United States. It lists 58 device types. The FDA files 106 510(k) clearances and 6 PMA approvals under its listings, the newest dated July 28, 2025. 106 recall events name it as the recalling firm (2 Class I). Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1416980
- Address
- 25212 W. Illinois Route 120, Round Lake, IL, United States, 60073
- Owner or operator
- BAXTER HEALTHCARE CORPORATION (1417572)
- Roles
- Complaint file establishment, Manufacturer, Specification developer
- First device listed
- April 1, 1991
- Registered through
- 2026
- Brand names listed
- 3 Lead Ext w/2 Interlink Inject Sit, 3 Port Adapter, 719-3 Li-Ion Plus USB Handle for Desk Charger, 719-DSK Welch Allyn Universal Desk Charger, 719-USB USB POWER SUPPLY,5V,1.4A,USB-A, ADAPTACAP, ALTAPORE, ARS-530 Air Regulator System and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance. Newest 100 of 106.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| July 28, 2025 | K251640 | SIGMA Spectrum Infusion Pump with Master Drug Library | FRN | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| July 28, 2025 | K251636 | Spectrum IQ Infusion System with Dose IQ Safety Software (3570009) | FRN | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| March 14, 2025 | K243529 | Solution Administration Sets | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| February 28, 2025 | K242339 | Intravascular Extension Sets and Accessories | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| January 15, 2025 | K242541 | GEM ZIPCLIP | FZP | Substantially Equivalent | Synovis Micro Companies Alliance A Subsidiary of Baxter Int | accessdata.fda.gov |
| September 5, 2024 | K242390 | Novum IQ Syringe Pump (40800BAXUS) | FRN | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| August 2, 2024 | K241564 | Actifuse ABX; Actifuse MIS; Actifuse Shape; ALTAPORE; ALTAPORE SHAPE; ALTAPORE MIS | MQV | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| March 29, 2024 | K230665 | Dose IQ Safety Software | PHC | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| March 29, 2024 | K211122 | Novum IQ Large Volume Pump | FRN | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| January 28, 2024 | K233394 | Gem Flow Now (GEM2770-FN) | IYN | Substantially Equivalent | Synovis Micro Companies Alliance | accessdata.fda.gov |
| April 7, 2023 | K223052 | Peri-Guard and Supple Peri-Guard | FTM | Substantially Equivalent | Synovis Life Technologies, Inc. | accessdata.fda.gov |
| March 10, 2023 | K223175 | lntravascular Administration Sets with Stopcock and Manifold | FMG | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| November 17, 2022 | K220558 | Blood Administration Sets | BRZ | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| October 19, 2022 | K221032 | Vascu-Guard Vascular Repair Patch | PSQ | Substantially Equivalent | Synovis Life Technologies, Inc. | accessdata.fda.gov |
| October 19, 2022 | K221029 | PERI-GUARD Repair Patch, SUPPLE PERI-GUARD Repair Patch | PSQ | Substantially Equivalent | Synovis Life Technologies, Inc. | accessdata.fda.gov |
| October 3, 2022 | K212262 | PCA Syringe Sets | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| September 14, 2022 | K221843 | GEM Biover Microvascular Clamps | DXC | Substantially Equivalent | Synovis Micro Companies Alliance, Inc. | accessdata.fda.gov |
| November 23, 2021 | K211649 | PCEA Syringe Set | PWH | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| October 27, 2021 | K213125 | PERI-STRIPS Dry Staple Line Reinforcement with VERITAS Collagen Matrix with SECURE GRIP Technology | FTM | Substantially Equivalent | Synovis Life Technologies. Inc. (A Subsidiary of Baxter | accessdata.fda.gov |
| September 30, 2021 | K203609 | Intravascular Administration Sets | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| June 18, 2021 | K210430 | Intravascular Extension Set | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| June 10, 2021 | K210335 | Blood Administration Set | BRZ | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| June 30, 2020 | K201464 | Altapore MIS | MQV | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| May 8, 2020 | K200640 | ALTAPORE SHAPE | MQV | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| January 9, 2020 | K192363 | Altapore | MQV | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| January 8, 2020 | K193137 | EASYGRIP FLO-41 Precision MIS Delivery System | GCJ | Substantially Equivalent | Baxter Healthcare Corportation | accessdata.fda.gov |
| December 17, 2019 | K192615 | Peri-Strips Dry with Veritas Collagen Matrix with Secure Grip Technology (PSDV-SG) | FTM | Substantially Equivalent | Synovis Life Technologies, Inc. (Baxter International Inc.) | accessdata.fda.gov |
| September 6, 2019 | K190499 | Gem FlowCoupler System | MVR | Substantially Equivalent | Baxter/ Synovis Micro Companies Alliance, Inc. | accessdata.fda.gov |
| July 9, 2019 | K191252 | Gem FlowCoupler System | MVR | Substantially Equivalent | Baxter/ Synovis Micro Companies Alliance, Inc. | accessdata.fda.gov |
| May 28, 2019 | K180739 | Clearlink System Solution Set | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| August 17, 2018 | K181306 | Actifuse Flow | MQV | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| May 11, 2018 | K173084 | Spectrum IQ Infusion System, Dose IQ Safety Software | FRN | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| September 22, 2017 | K172544 | IV Fat Emulsion Administration Sets | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| November 30, 2016 | K161323 | Solution Set for Epidural Use | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| December 28, 2015 | K153158 | Solution Administration Sets with 0.2 Micron Filter | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| April 16, 2015 | K150860 | Nitroglycerin Sets with DUO-VENT Spike | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| January 16, 2015 | K143589 | GEM Flow COUPLER Device and System | MVR | Substantially Equivalent | Synovis Life Technologies, Inc. | accessdata.fda.gov |
| November 19, 2014 | K142600 | VIAL-MATE Adaptor | LHI | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| September 16, 2014 | K142309 | GEM Flow COUPLER Device and System | MVR | Substantially Equivalent | Synovis Life Technologies, Inc. | accessdata.fda.gov |
| August 18, 2014 | K142011 | SOLUTION SET/EXTENSION SET | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| May 7, 2014 | K133801 | BAXTER SIGMA SPECTRUM INFUSION PUMP WITH MASTER DRUG LIBRARY | FRN | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| October 22, 2013 | K132727 | GEM FLOW COUPLER DEVICE AND SYSTEM | MVR | Substantially Equivalent | Synovis Life Technologies, Inc. | accessdata.fda.gov |
| October 8, 2013 | K132734 | NEUTRAL LUER ACTIVATED DEVICE (ONE-LINK NEEDLE-FREE IV CONNECTOR) AND EXTENSION SETS | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| April 24, 2013 | K130896 | VASCULAR PROBE, VASCULAR PROBE ES | DWP | Substantially Equivalent | Synovis Life Technologies, Inc. | accessdata.fda.gov |
| March 1, 2013 | K130245 | LARGE BORE STOPCOCK WITH ROTATING MALE LUER LOCK/LARGE BORE STOPCOCK WITH EXTENSION SET, GANG LARGE BORE STOPCOCK MANIFO | FMG | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| January 10, 2013 | K123874 | INTERLINK SYSTEM BURETROL SOLUTION SETS, INTERLINK SYSTEM BURETROL SOLUTION SETS, CONTINUED, CLEARLINK SYSTEM BURETROL S | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| January 8, 2013 | K123868 | INTERLINK SYSTEM LEVER LOCK CANNULA WITH CHECK VALVE, SECONDARY MEDICATION SETS, SOLUTION SETS, CONTINU-FLO SOLUTION SET | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| June 29, 2012 | K121634 | INTERLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO-REGULATORY CLEARLINK SYSTEM EXTENSION SET WITH CONTROL-A-FLO-REGULATOR | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| December 8, 2011 | K113227 | NON-DEHP MICRO-VOLUME EXTENSION SET WITH 0.22 MICRON FILTER | FPB | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| October 18, 2011 | K112893 | CLEARLINK LUER ACTIVATED VALVE, CLEARLINK SYSTEM NON-DEHP CATHETER EXTENSION SETS | FPA | Substantially Equivalent | Baxter Healthcare Corporation | accessdata.fda.gov |
| June 14, 2011 | K111217 | ADDITIVE CAP | KPE | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| October 8, 2010 | K102071 | OSTENE CT, AOC CT, OSTEOTENE, CERETENE | MTJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| July 2, 2010 | K101487 | CHEETAH NICOM SYSTEM | DXG | Substantially Equivalent | Cheetah Medical, Inc. | accessdata.fda.gov |
| February 1, 2010 | K093310 | GEM FLOW COUPLER DEVICE AND SYSTEM | MVR | Substantially Equivalent | Synovis Micro Companies Alliance, Inc. | accessdata.fda.gov |
| July 30, 2009 | K090850 | ACTIFUSE BONE GRAFT SUBSTITUTE, ACTIFUSE MICROGRANULES BONE GRAFT SUBSTITUTE | LYC | Substantially Equivalent | Apatech , Ltd. | accessdata.fda.gov |
| June 22, 2009 | K091636 | OSTENE CT, AOC CT, OSTEOTENE, CERETENE | MTJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| November 26, 2008 | K083039 | VERITAS COLLAGEN MATRIX (DRY) | FTM | Substantially Equivalent | Synovis Surgical Innovations | accessdata.fda.gov |
| November 25, 2008 | K082575 | ACTIFUSE BONE GRAFT SUBSTITUTE AND ABX E-Z-FIL AND SHAPE BONE GRAFT SUBSTITUTES | MQV | Substantially Equivalent | Apatech , Ltd. | accessdata.fda.gov |
| November 6, 2008 | K081979 | ACTIFUSE BONE GRAFT SUBSTITUTE AND E-Z-FIL AND SHAPE BONE GRAFT SUBSTITUTE | MQV | Substantially Equivalent | Apatech , Ltd. | accessdata.fda.gov |
| September 24, 2008 | K082491 | OSTENE CT SOLUBLE BONE HEMOSTASIS IMPLANT MATERIAL, AOC CT, AOC, OSTENE, OSTEOTENE & CERETENE | MTJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| September 11, 2008 | K082073 | ACTIFUSE FLOW BONE GRAFT SUBSTITUTE | MQV | Substantially Equivalent | Apatech , Ltd. | accessdata.fda.gov |
| September 9, 2008 | K071783 | VERSAPOD (TM) INSTRUMENT TRAYS | KCT | Substantially Equivalent | Containmed, Inc. | accessdata.fda.gov |
| April 16, 2008 | K080736 | ACTIFUSE SHAPE BONE GRAFT SUBSTITUTE | MQV | Substantially Equivalent | Apatech , Ltd. | accessdata.fda.gov |
| May 31, 2007 | K071206 | ACTIFUSE ABX E-Z-FIL PUTTY BONE GRAFT SUBSTITUTE | MQV | Substantially Equivalent | Apatech , Ltd. | accessdata.fda.gov |
| January 24, 2007 | K070093 | OSTENE, AOC, OSTEOTENE, CERETENE, CEREPOR, APTENE, APATENE, ACTIPASTE | KHJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| December 11, 2006 | K062280 | OSTENE, AOC, OSTEOTENE, CERETENE, CEREPOR, APTENE, APATENE AND ACTIPASTE | KHJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| December 6, 2006 | K062915 | VERITAS COLLAGEN MATRIX | FTM | Substantially Equivalent | Synovis Surgical Innovations | accessdata.fda.gov |
| March 29, 2006 | K060074 | INTERLINK SYSTEM-T-CONNECTOR EXTENSION SET, MODEL 2N3326 | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| October 11, 2005 | K052528 | AOC BONE WAX OSTENE, OSTEOTENE AND CERETENE | MTJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| May 2, 2005 | K050495 | EASYSPRAY AND SPRAY SET FOR TISSEEL (FIBER SEALANT) | FMF | Substantially Equivalent | Baxter Healthcare Corp., Bioscience | accessdata.fda.gov |
| March 24, 2005 | K050440 | AOC BONE WAX, OSTENE, OSTEOTENE, ORTHOSEAL, OSTEOSEAL, CERETENE, MODEL BW-12 | MTJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| October 27, 2004 | K041669 | VERITAS DRY COLLAGEN MATRIX, VERITAS DRY OR VERITAS PSD | FTM | Substantially Equivalent | Synovis Surgical Innovations | accessdata.fda.gov |
| August 4, 2004 | K040082 | PORE-SI BONE GRAFT SUBSTITUTE | MQV | Substantially Equivalent | Apatech , Ltd. | accessdata.fda.gov |
| July 27, 2004 | K041363 | AOC BONE WAX | MTJ | Substantially Equivalent | Ceremed , Inc. | accessdata.fda.gov |
| August 12, 2002 | K022523 | RAPID-FILL TUBESET, MODEL 90005 | LHI | Substantially Equivalent | Baxa Corp. | accessdata.fda.gov |
| June 24, 2002 | K020666 | DUPLOJECT EASY-PREP SYSTEM 1ML, 2ML, 5ML | FMF | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| June 7, 2002 | K014088 | DUPLOREACH | FMF | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| June 28, 2001 | K011317 | MULTIRATE INFUSOR SV; MULTIRATE INFUSER LV; BAXTER PAIN MATE PAIN MANAGEMENT SYSTEM | MEB | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| March 28, 2001 | K002705 | EXACTA-MIX 2400 COMPOUNDING SYSTEM, MODEL EXACTA-MIX 2400 | LHI | Substantially Equivalent | Baxa Corp. | accessdata.fda.gov |
| December 20, 2000 | K003730 | CHEMO-AIDE DISPENSING PIN | LHI | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| July 5, 2000 | K981089 | TISSOMAT AND SPRAY SET | FMF | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| November 17, 1999 | K993120 | MODIFIED BLOOD RECIPIENT SET | BRZ | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| November 12, 1998 | K983602 | CV PERI-GUARD AND VASCU-GUARD | DXZ | Substantially Equivalent | Bio-Vascular, Inc. | accessdata.fda.gov |
| October 9, 1998 | K983162 | PERI-GUARD, CV PERI-GUARD, OCU-GUARD, SUPPLE PERI-GUARD, PERI-STRIPS - SLEEVE, PERI-STRIPS-STRIPS, PERI-STRIPS DRY, VASC | FTM | Substantially Equivalent | Bio-Vascular, Inc. | accessdata.fda.gov |
| August 4, 1998 | K981624 | FLO-THRU | DXC | Substantially Equivalent | Bio-Vascular, Inc. | accessdata.fda.gov |
| July 30, 1998 | K982282 | DURA-GUARD - DURAL REPAIR PATCH | GXQ | Substantially Equivalent | Bio-Vascular, Inc. | accessdata.fda.gov |
| December 8, 1997 | K973510 | DUPLOJECT (0.5/1.0 ML, 2.0 ML, 5.0 ML) | FMF | Substantially Equivalent | Immuno-U.S., Inc. | accessdata.fda.gov |
| March 31, 1997 | K964853 | INTRAVIA CONTAINER, EMPTY | KPE | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| June 21, 1996 | K961225 | CONTINUFLO SOLUTION SET/SECONDARY MEDICATION SET | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| May 14, 1996 | K960787 | TUR,ARTHROSCOPIC,CYSTOSCOPY IRRIGATION SETS | LJH | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| July 27, 1995 | K952074 | SOLUTION SET WITH 1.2 MICRON AIR ELIMINATING FILTER | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| August 3, 1993 | K925058 | BARD AMBU PUMP SPIK TUB SET PACRET PROVID PUMP SET | FPA | Substantially Equivalent | C.R. Bard, Inc. | accessdata.fda.gov |
| June 18, 1993 | K925126 | INTERLINK(TM) INJECTION SITE | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| April 21, 1993 | K924064 | INTERLINK UNIVERSAL VIAL ADAPTER | LHI | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| April 20, 1993 | K921899 | INTERLINK SYSTEM - T-CONNECTOR EXTENSION SET | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| March 12, 1992 | K915390 | 3 LEAD EXTENSION WITH 2 INTERLINK INJECTION SITES | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| September 23, 1991 | K913627 | 3 PORT ADAPTER | FPA | Substantially Equivalent | Baxter Healthcare Corp | accessdata.fda.gov |
| February 7, 1991 | K905159 | FLO-RESTER(R) VESSEL SIZER | DWP | Substantially Equivalent | Bio-Vascular, Inc. | accessdata.fda.gov |
| November 7, 1990 | K903159 | VALVE CONTROLLER FOR MICROMACRO COMPOUNDER | LHI | Substantially Equivalent | Baxa Corp., Sub. of Cook Group, Inc. | accessdata.fda.gov |
| April 18, 1990 | K900585 | TUBING SETS FOR BAXA EXACTA-MED PHARMACY PUMP | LHI | Substantially Equivalent | Baxa Corp., Sub. of Cook Group, Inc. | accessdata.fda.gov |
PMA approvals
Premarket approvals this establishment lists, with the supplements the FDA has decided since.
| Approved | PMA number | Device | Product code | Supplements | Latest decision | Source |
|---|---|---|---|---|---|---|
| May 19, 2023 | P210036 | PerClot® Polysaccharide Hemostatic System | LMG | 7 | August 7, 2026 | accessdata.fda.gov |
| March 1, 2013 | P100030 | ARTERX SURGICAL SEALANT | NBE | 18 | July 10, 2025 | accessdata.fda.gov |
| July 28, 2006 | P050011 | ADEPT (4% ICODEXTRIN) ADHESION REDUCTION SOLUTION | MCN | 9 | August 23, 2024 | accessdata.fda.gov |
| December 12, 2003 | P030039 | COSEAL SURGICAL SEALANT | NBE | 28 | December 18, 2025 | accessdata.fda.gov |
| December 8, 1999 | P990009 | FLOSEAL MATRIX/FLOSEAL MATRIX HEMOSTATIC SEALANT/PROCEED HEMOSTATIC SEALANT | PMX | 74 | November 13, 2025 | accessdata.fda.gov |
| August 12, 1996 | P950034 | SEPRAFILM(TM) (HAL-F(TM)) BIORESORBABLE MEMBRANE | MCN | 52 | December 19, 2024 | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI. Newest 100 of 106.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| June 30, 2021 | 88219 | Class II | Terminated | Sharesource Connectivity Platform for Use with the Amia Automated PD System | Baxter Healthcare Corporation has identified that the AMIA Sharesource User Guide that is used with the AMIA Automated PD System cyclers incorrectly describes the function of the UF (Ultrafiltration) Limit setting as the ending criteria of the cyclers Extra Last Drain Mode. In some locations in the guide, it states that the UF volume achieved must exceed the | accessdata.fda.gov |
| September 3, 2014 | 69122 | Class II | Terminated | SPECTRUM Pump, Model No. 35700BAX. Intended to be used for the controlled administration of intravenous fluids. | One Service Technician may not have correctly serviced specific Sigma Spectrum Infusion Pumps according to established procedures during the time period of 5/5/2014 through 6/3/2014. | accessdata.fda.gov |
| October 16, 2013 | 66737 | Class II | Terminated | The HomeChoice Pro APD System is a peritoneal dialysis system. The HomeChoice Pro Automated Personal Cycler peritoneal dialysis system is intended for automatic control of dialysate solution exchange in the treatment of | The occluder in affected devices 1) may have sharp edges that could cut the pneumatic tubing that connects the occluder blade to the manifold causing an unrecoverable system error, and/or 2) blade may separate from the back plate and cause Slow / No Flow alarm requiring therapy termination. | accessdata.fda.gov |
| June 7, 2013 | 65365 | Class II | Terminated | Brand Name: Infusor SV and LV Elastomeric Infusion Devices. Indicated for the intravenous administration of medications. | Baxter Healthcare Corporation (Baxter) is issuing an Urgent Product Recall for the products listed above due to an increase in rupture complaints. Baxter has implemented product and process improvements which have substantially improved product quality. Complaint rates for ruptures have since decreased. Baxter wants to ensure that no affected product remains | accessdata.fda.gov |
| June 7, 2013 | 65364 | Class II | Terminated | Brand Name: Coiled Tube Infusors (Portable Elastomeric Infusion Systems). Baxter's Infusor SV Elastomeric Infusion Device Device Listing: D020871 Baxter's lnfusors SV Elastomeric Infusion Device is a single-use, disposab | Due to an increase in complaints for leaks at the distal male Luer and Luer cap. Baxter implemented enhancements to the blue winged cap to improve the seal between the cap and the Luer. | accessdata.fda.gov |
| December 14, 2012 | 63898 | Class II | Terminated | Baxter Non-DEHP Micro-Volume Extension Set, Male Luer Lock Adapter, 36 (91 cm), Volume 0.32 mL; an Rx sterile, single use nonpyrogenic fluid pathway; 50 sets per case; For the administration of drugs and solutions to a p | Some of the individual extension set packages were improperly sealed, compromising the sterility of the product. | accessdata.fda.gov |
| September 7, 2012 | 63059 | Class I | Terminated | Baxter Interlink System Buretrol Solution Set with 150 mL Burette (Ball-Valve Drip Chamber); a sterile Rx IV fluid pathway device. Product Usage: The device is used for the administration of fluids from a container into | Baxter has determined that the ball-valve feature of the Buretrol Solution Sets may not function as expected, allowing air to flow past the valve and into the tubing at the completion of dose within the burette. | accessdata.fda.gov |
| July 13, 2012 | 62558 | Class I | Terminated | AUTOMIX High Speed Compounder System, product 2M8077; automated nutrition compounders; Product Usage: The Automix Compounder Systems are electromechanical positive displacement fluid compounding devices used in the admix | After fluid ingress into the keypad of the AUTOMIX Compounder's (AUTOMIX) control module, the AUTOMIX may generate an incorrect device response to an AUTOMIX operator's key press. Also, the AUTOMIX system may experience an intermittent electrical failure, in which unexpected pump motor operations will occur. Also, the AUTOMIX system may intermittently experi | accessdata.fda.gov |
| December 6, 2011 | 60608 | Not yet classified | Terminated | Baxter Interlink System Continu-Flo Solution Set, 71" (1.8 m), 2 Injection Sites, Male Luer Lock Adapter, Standard Bore 3-Way Stopcock Manifold, Extension Set, 44" (112 cm), Vol. 6.6 mL, Injection Site, Male Luer Lock Ad | During production of the IV sets, solvent was inadvertently applied to the locking collar of the male luer connector, which may have damaged the component, preventing proper engagement of the locking collar to secure a connection. | accessdata.fda.gov |
| August 26, 2011 | 60168 | Not yet classified | Terminated | Baxter Flo-Gard 6301 Dual Channel Volumetric Infusion Pump; Baxter Healthcare Corporation, Deerfield, IL 60015; Product Code # 2M8064. The Flo-Gard Volumetric Infusion Pumps are an electromechanical pump used for intrave | The Flo-Gard infusion Pump was released to the customer with OOS values for the Air Sensor Calibrations with the Air in Tubing test. | accessdata.fda.gov |
| August 15, 2011 | 59734 | Not yet classified | Terminated | LOGIX Order Entry (OE) Software, all versions, catalog 2M8410; Baxter Healthcare, Deerfield, IL 60015; The software is included in a number of Baxter's pharmacy compounders. The software assists the pharmacist in managem | There is the potential for an order entry error during use of the LOGIX Order Entry (OE) software. When adding ingredients to a TPN order, the user can accept the pre-populated "per units" of "Bag" or select other "per units". A dosing error may occur if the user does not select the prescribed "per units" for the added ingredient. | accessdata.fda.gov |
| July 22, 2011 | 59449 | Not yet classified | Terminated | Baxter Colleague CX Infusion Pump, Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015. Product Code: 2M8161. Product Usage: Intended for use in a wi | Baxter's Service Center tested and returned to the user the Colleague infusion pump that did not meet PSIG (Pounds-force per Square Inch) specifications | accessdata.fda.gov |
| July 22, 2011 | 59448 | Not yet classified | Terminated | Baxter Colleague CX Infusion Pump, Single Channel Volumetric Infusion Pump. Baxter Healthcare Corporation, Deerfield, IL. Product Code: 2M8161. Intended for use in a wide variety of patient environments for adult, pediat | The Colleague infusion pump may not have met certain Air in Line (AIL) specifications after testing by the Baxter Global Technical Service Center. This issue could potentially cause a delay in initiation of therapy. | accessdata.fda.gov |
| July 22, 2011 | 59445 | Not yet classified | Terminated | Baxter Colleague CX Infusion Pump, Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Deerfield, IL; product code 2M8161 | A review of Baxter service records indicates that the Baxter Colleague CX Infusion Pump has not met certain voltage specifications. This issue could potentially cause a delay in initiation of therapy. | accessdata.fda.gov |
| July 21, 2011 | 59419 | Not yet classified | Terminated | Baxter Solution Set with Duo-Vent Spike; 109" (2.8 m), Male Luer Lock Adapter 10 drops/mL. Baxter Healthcare Corporation. A sterile, single use, nonpyrogenic fluid pathway for use with rigid nonvented and flexible contai | The Solution Sets are being recalled because the position of the slide clamp and roller clamp may have been reversed during assembly. The reversed orientation of the slide clamp and roller clamp will cause the set to be incorrectly loaded into an infusion pump, resulting in fluid flow from the patient to the pump, rather than from the pump to the patient. | accessdata.fda.gov |
| July 6, 2011 | 59263 | Not yet classified | Terminated | Baxter Interlink System Non-DEHP I.V. Catheter Extension Set, 6.6(17 cm), Volume 0.8 mL, Injection Site, Male Luer Lock Adapter; an Rx sterile, single use nonpyrogenic fluid pathway; 200 sets per case; Baxter Healthcare | Some of the individual extension set packages were improperly sealed, compromising the sterility of the product. | accessdata.fda.gov |
| July 5, 2011 | 59270 | Not yet classified | Terminated | Baxter Colleague CX Infusion Pump, Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division. Product Code: 2M8161. Product Usage: Intended for use in a wide variety of patient | While replacing a defective pump head mechanism and performing calibration, Baxter's Service center may have failed to apply GLYPTOL (a red insulating varnish) on a potentiometer that helps maintain pump accuracy for detecting an air bolus. | accessdata.fda.gov |
| May 31, 2011 | 58913 | Not yet classified | Terminated | Baxter Solution Set for Epidural Use, 110" (2.8 m), Male Luer Lock Adapter; a sterile, single use, nonpyrogenic fluid pathway for use with 6200 and 6300 series Flo-Gard Volumetric Infusion Pumps; Baxter Healthcare corpor | The lot of Baxter Solution Set for Epidural Use is being recalled because the position of the slide clamp and roller clamp may have been reversed during assembly. The reversed orientation of the slide clamp and roller clamp will cause the set to be incorrectly loaded into an infusion pump, resulting in fluid flow from the patient to the pump, rather than fro | accessdata.fda.gov |
| May 17, 2011 | 58834 | Not yet classified | Terminated | Baxter Interlink System Large Bore 4-Way Stopcock, Volume 0.65 mL, Injection Site, Rotating Male Luer Lock; a sterile, nonpyrogenic fluid pathway; product code 2N5601. Intended use: For the administration of drugs and so | There is the potential for pinholes and tears in the individual packaging of the stopcocks, compromising the sterility of the product. | accessdata.fda.gov |
| May 4, 2011 | 58806 | Not yet classified | Terminated | Baxter Colleague 3 and 3 CX Infusion Pumps, Triple Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division. Product Codes: 2 M8153 and 2M8163. Intended for use in a wide variety of | The Air In Line (AIL) test was not properly performed by the service technician at the Service Center. | accessdata.fda.gov |
| April 14, 2011 | 58586 | Not yet classified | Terminated | Baxter Colleague, Colleague CX and Colleague CXE Infusion Pumps, Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division. Product Codes: 2M8151, 2M8161 and 2M9161. Intended f | The Hi-Pot safety testing may not have been conducted on the affected pumps during service, prior to being returned to the end user. | accessdata.fda.gov |
| March 29, 2011 | 58420 | Not yet classified | Terminated | LOGIX Order Entry (OE) Software, all versions, catalog 2M8410; Baxter Healthcare, Deerfield, IL 60015; The software is included in a number of Baxter's pharmacy compounders. The software assists the pharmacist in managem | The LOGIX OE automated backup does not retain the three most recent backup files and instead will only retain the last three backups of the previous year. The software stores backup files in numeric order rather than chronological date order. | accessdata.fda.gov |
| March 24, 2011 | 58482 | Not yet classified | Terminated | Baxter Flo-Gard 6201, Single Channel Volumetric Infusion Pump; Baxter Healthcare Corporation, Deerfield, IL 60015; Product Code # 2M8063 The Flo-Gard Volumetric Infusion Pumps are an electromechanical pump used for intra | Pumps submitted for service may not have been properly serviced before being returned to the customer. | accessdata.fda.gov |
| March 15, 2011 | 58181 | Not yet classified | Terminated | Baxter Single Day Infusor 2 mL/h Portable Elastomeric Infusion System; an Rx sterile disposable drug delivery system; Baxter Healthcare Corporation, Deerfield, IL 60015; REF 2C1071KJP The Infusor device is indicated for | Some of the Single Day Infusor System 2 mL/h have a foil over-pouch that was incorrectly labeled as the Half Day Infusor System 5 mL/h, product code 2C1073KJP, lot 10H054. | accessdata.fda.gov |
| March 4, 2011 | 62881 | Class III | Terminated | Mini-Infuser Model 150XL Single Speed Infusion Pump, an Rx battery operated syringe infusion pump; Product Usage: These product codes includes refurbished units. Intended for the controlled rate delivery of small volume | Should a battery with the minimum contact diameter (.51 inches) be placed on the battery spring (.53 inches), an electrical circuit will not be completed and the Mini-Infuser will not operate. The reason being that the Mini-Infuser Battery Spring has a flat contact that measures.53 inches.01 inches on the inner diameter of the spring coil. The IEC 60086-2 an | accessdata.fda.gov |
| January 27, 2011 | 57790 | Not yet classified | Terminated | AUTOMIX High Speed Compounder System, product 2M8077; automated nutrition compounders; Baxter Healthcare Corporation, Clintec Nutrition Division, Deerfield, IL 60015 The Automix Compounder Systems are electromechanical p | The AUTOMIX compounder may not respond correctly to the key pressed by the operator using the keypad. The incorrect keypad response issue can occur both in manual data entry mode (STD Mode) and when entering order numbers to download from host software (MAN ID Mode). It is possible that an incorrect volume and/or an incorrect solution could be admixed into t | accessdata.fda.gov |
| January 10, 2011 | 57666 | Not yet classified | Terminated | InfusO.R. Infusion Pump, an Rx syringe infusion pump; Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A.; product codes 2L3100, 2L3100R, 2L3100U, 6461500 and 6461500R. These product codes includes refurbished unit | Should a battery with the minimum contact diameter (.51 inches) be placed on the battery spring (.53 inches), an electrical circuit will not be completed and the InfusOR will not operate. The reason being that the InfusOR (2L3100) Battery Spring has a flat contact that measures.53 inches.01 inches on the inner diameter of the spring coil. The IEC 60086-2 and | accessdata.fda.gov |
| December 1, 2010 | 57516 | Not yet classified | Terminated | Baxter Colleague CX and CXE Infusion Pumps, Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division. Product Codes: 2M8161 and 2M9161. Intended for use in a wide variety of p | The Air In Line (AIL) test was not properly performed by the service technician at the Service Center. | accessdata.fda.gov |
| December 1, 2010 | 57515 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pump. Baxter Healthcare Corporation, Medication Delivery Division. Product Code: 2M8161 | While the infusion pump was being serviced at the Baxter Service Center, it was inadvertently routed to the packaging area before the final inspection. | accessdata.fda.gov |
| November 17, 2010 | 57334 | Not yet classified | Terminated | Baxter FloGard 6201 Volumetric Infusion Pump. Baxter Healthcare Corporation, Medication Delivery Division. Product code 2M8063 For delivery of intravenous solutions, drug solutions, enteral feedings and blood. | The FloGard Infusion Pump was released from service without having the Current Leakage test performed. This could lead to the patient/user to receive an electrical shock. | accessdata.fda.gov |
| October 28, 2010 | 57089 | Not yet classified | Terminated | Baxter Three-Way Large Bore Stopcock with Rotating Male Luer Lock Adapter; a sterile, nonpyrogenic fluid pathway; Baxter Healthcare Corporation, Deerfield, IL 60015; product code 2C6201. Intended use: For the administrat | Rotating the handle on the 3-Way Large Bore Stopcock past the stop can cause the stopcock to leak. A leak can lead to under-infusion or interruption of critical life-sustaining therapy. | accessdata.fda.gov |
| October 21, 2010 | 56892 | Not yet classified | Terminated | Baxter Interlink System, Micro-Infusion Manifold; and Interlink Manifold. An Rx sterile device with 3 injection sites, volume per injection site 0.1 mL, priming volume 0.8 mL, length 8.7 cm. Product code 2N3410 and A2N34 | If the manifolds are connected in series, there may be a risk of the manifolds loosening or disconnecting at the luer connection between them. | accessdata.fda.gov |
| September 17, 2010 | 56792 | Not yet classified | Terminated | Baxter V-Link Luer Activated Device with Vitalshield Protective Coating Non-DEHP Catheter Extension Set Kit; 7.6" (19.3 cm), Vol. 1.0 mL, 1 Catheter Extension Set with Luer Activated Device with Silver for IV Access and | The removable paper liner covering the adhesive strip that is used to secure the catheter stabilization device to the patient is pyrogenic. The device is labeled as nonpyrogenic. | accessdata.fda.gov |
| September 9, 2010 | 56718 | Not yet classified | Terminated | Baxter Clearlink System Non-DEHP Y-Type Catheter Extension Set, 6.5" (16.5 cm), Vol 1.2 mL, Luer Activated Valve for I.V. Access, Male Luer Lock Adapter with Retractable Collar; an Rx sterile device; Manufactured by an a | During packaging testing, Baxter observed tears and pinholes in Chevron-style pouches for certain infusion disposable products. The pinholes and tears could compromise the sterile barrier properties of the pouch. | accessdata.fda.gov |
| September 3, 2010 | 56699 | Not yet classified | Terminated | Baxter Interlink System Buretrol Solution Set, 83" (2.1 m), 150 mL Burette Drip Chamber Filter Valve, 2 Injection Sites, Male Luer Lock Adapter, Large Bore 4-Way Stopcock with Rotating Male Luer Lock Extension Set, 38" ( | There are leaks in the Drip Chamber Check Valve Subassembly of the Solution Set. A leak in a sterile pathway could allow microbial entry, which could lead to a blood stream infection. | accessdata.fda.gov |
| August 4, 2010 | 56425 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division. Product Codes: 2M8151, 2M8161, and 2M9161. | The FDA sent a letter to Baxter on April 30, 2010, ordering the company to recall and destroy all models of its Colleague Volumetric Infusion Pumps currently in use in the United States. FDA determined that this action is necessary, as Baxter has failed to adequately correct, within a reasonable timeframe, the deficiencies in the Colleague pumps still in use | accessdata.fda.gov |
| July 14, 2010 | 60520 | Not yet classified | Terminated | Baxter Colleague CX Infusion Pump, Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015. Product Code: 2M8161. Product Usage: Intended for use in a wi | Baxter's Service Center did not perform the ground impedance and leakage current test which verify if any power overflow occurs and that it is properly discharged through the device electrical system. | accessdata.fda.gov |
| February 15, 2010 | 55016 | Not yet classified | Terminated | Baxter RenAmin (Amino Acid) Injection; Pharmacy Bulk Package Not for Direct Infusion, Rx Only, 250 mL type II glass bottles; Baxter Healthcare Corporation, Clintec Nutrition Division, Deerfield, IL 60015 USA, Made in USA | Routine stability testing of the evacuated container product, along with trending of results, indicates that the pH will exceed the upper specification limit prior to the expiration date of this product. Baxter decided to remove all potentially affected products even though there have been no out-of-specification pH results at the 0, 6 and 12 month intervals | accessdata.fda.gov |
| November 3, 2009 | 53751 | Not yet classified | Terminated | Buretrol Solution Sets, a sterile fluid pathway of 105 (2.7 m), 60 drops/mL, with 150 mL Burette Drip Chamber Filter Valve, 2 injection Y-sites, 3 Luer Activated Valves and Male Luer Lock Adapter with Retractable Collar; | The tubing may separate from the distal Clearlink Y-site of the set, which could result in patient injury if the separation occurs during patient use. | accessdata.fda.gov |
| July 2, 2009 | 52560 | Not yet classified | Terminated | Baxter Minicap Extended Life PD Transfer Set (6") with Twist Clamp; six sets per carton; Baxter Healthcare Corporation, Deerfield, IL 60015 USA; product code 5C4482 The set is used in disconnect applications and cycler a | The peritoneal dialysis transfer set has a defective white sleeve twist clamp. The twist clamp will not open or close completely, which could cause leakage and lead to peritonitis. | accessdata.fda.gov |
| May 8, 2009 | 60521 | Not yet classified | Terminated | Baxter Colleague CX Infusion Pump, Single Channel Volumetric Infusion Pumps. Product Code: 2M8161. | There was no documentation to show the required tests were performed following the replacement of the battery and battery harness. | accessdata.fda.gov |
| January 23, 2009 | 50839 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pumps. Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A., Made in Singapore. Product Codes: 2M8151, 2M8161, 2M9161, DNM8151, DNM91 | Baxter has identified failure codes that lead to an interruption of therapy, hazards associated with improper cleaning, and damaged battery messages for the Colleague Infusion Pumps. | accessdata.fda.gov |
| September 5, 2008 | 49443 | Not yet classified | Terminated | Baxter Auto Syringe AS50 Infusion Pump, product code 1M8550; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A. Indicated for infusion via intravenous, intra-arterial, epidural or sub | Non-conforming Electrostatic Discharge (ESD) grounding squares may cause the pump to be susceptible to shorting-out of circuitry, resulting in a loss of audio, and/or interruption of therapy. | accessdata.fda.gov |
| March 28, 2008 | 47441 | Not yet classified | Terminated | Logix TPN Software Solution, catalog 2M8410, consists of the Logix Order Entry (OE) Installation CD, version 1.0.28 and Logix Compounder Manager (CM) Installation CD, version 3.1.8. The software is included in a number o | Software anomaly results in inaccurate information being printed out on the Delivery Report, even though the compounder performed the compounding correctly. | accessdata.fda.gov |
| February 28, 2008 | 46912 | Not yet classified | Terminated | Baxter HEP LOCK (Heparin Lock Flush Solution, USP) 10 u/mL-1mL vial, 25 Pack, NDC 0641-0392-25 (NDC 0641-0392-21; on vial), Baxter Healthcare Corporation, Deerfield, IL 60015 | Due to an increase of adverse events in Baxter single and multi-dose Heparin for injection products, which used the same active pharmaceutical ingredient (API) source as the HEP LOCK products | accessdata.fda.gov |
| November 29, 2007 | 45919 | Not yet classified | Terminated | Baxter Single Day INFUSOR Portable Elastomeric Infusion System, Product Code: 2C1071KJP; 2mL/hr with Tubing Flow Restrictor; 12 units per case; Baxter Healthcare Corporation, Deerfield, IL 60015 | Leaking: leaks at the tubing flow restrictor connection to either the coupler or the male luer during filling. | accessdata.fda.gov |
| August 15, 2007 | 39415 | Not yet classified | Terminated | Baxter Colleague CX Single Channel Volumetric Infusion Pumps; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A., Made in Singapore; product code 2M8161 | Some of the pumps were upgraded by one service technician who failed to replace prisms and batteries as required in the upgrade. | accessdata.fda.gov |
| June 21, 2007 | 38221 | Not yet classified | Terminated | Baxter Flo-Gard 6201, SIngle Channel, Volumetric Infusion Pump; Baxter Healthcare Corporation, Deerfield, IL 60015; Product Code # 2M8063 | Falsified Repair/Test and Inspection records: Pumps submitted for repair or service may not have been properly repaired or serviced before being returned to the customer. | accessdata.fda.gov |
| June 20, 2007 | 38219 | Not yet classified | Terminated | Baxter Colleague Triple Channel Volumetric Infusion Pumps; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A., Made in Singapore; product codes 2M8153, 2M8163, 2M9163 | A software anomaly is causing newly upgraded Colleague Triple Channel Infusion Pumps to alarm, display an error code (16:310:867:0002) and stop the infusion. This occurs during user programming with all three channels simultaneously infusing fluids. In reported cases, the pump stopped infusing and both an audible and a visual alarm notification were activate | accessdata.fda.gov |
| February 16, 2007 | 37362 | Not yet classified | Terminated | Baxter Clearlink System Vented Paclitaxel Set; a sterile fluid pathway with polyethylene lined tubing, non-DEHP 12 inch pump segment, 0.22 micron downstream high pressure filter, Luer activated valve, male Luer lock adap | Baxter has received reports of disconnections/leaks during use of vented Paclitaxel administration sets. | accessdata.fda.gov |
| December 6, 2006 | 36928 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pumps; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A., Made in Singapore; product codes 2M8151, 2M8151R, 2M8161, 2M8161R | Baxter has identified the potential for a corruption of the memory chip in the pump to occur due to linear accelerator radiation exposure. If corruption occurs, it could result in an interruption of therapy with an audible and visual alarm notification to the user. | accessdata.fda.gov |
| November 27, 2006 | 36872 | Not yet classified | Terminated | Baxter Flo-Gard 6201 Volumetric Infusion Pump, catalog #2M8063, 2M8063R (refurbished); Baxter Healthcare Corporation, Deerfield, IL 60015 | There is the potential for non-detection of, and no alarm for, upstream occlusion for Flo-Gard Volumetric Infusion Pumps, if an occlusion occurs above a flexible chamber such as a drip chamber, Buretrol or blood filter. | accessdata.fda.gov |
| February 8, 2006 | 34579 | Not yet classified | Terminated | Baxter Auto Syringe AS40 and AS40A Infusion Pump, product code 1M8565 (pumps with drug library option) and product codes 1M8560 and 1M8560R (pumps without drug library option); Baxter Healthcare Corporation, Medication D | The occlusion detection and alarm may be delayed when the pumps are used with larger volume syringes at low flow rates. | accessdata.fda.gov |
| February 7, 2006 | 34580 | Not yet classified | Terminated | Baxter Auto Syringe AS50 Infusion Pump, product code 1M8550; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A. | A non-conforming gasket was used in manufacturing of the specific pumps, causing the pumps to be more susceptible to electro-static discharge, which could increase the potential for the pump to fail during use and alarm. | accessdata.fda.gov |
| January 10, 2006 | 34381 | Not yet classified | Terminated | Baxter Continuous Epidural Anesthesia Trays that contain BD Catheter Connectors; Sterile, single use only kits containing an epidural needle, epidural catheter, glass LOR syringe and non-latex components for the preparat | The BD catheter connector contained in the Epidural Anesthesia Trays may not fully secure the catheter and allows the catheter to either become loose or disconnected from the connector. | accessdata.fda.gov |
| December 21, 2005 | 34244 | Not yet classified | Terminated | Baxter I-Pump Pain Management System infusion pump, product codes 2L3107, 2L3107K and 2L3107R, Baxter Healthcare Corporation, Deerfield, IL 60015 | Delivery of unrequested PCA doses of medication due to damaged PCA cords, partial sticking of PCA button, and fluid ingress into the pump or PCA button. | accessdata.fda.gov |
| December 15, 2005 | 34290 | Not yet classified | Terminated | Baxter Interlink System Non-DEHP Y-Type Catheter Extension Set, product code 2N8371; An Rx sterile, nonpyrogenic fluid pathway, 6.0'', 1.0 mL Vol., with 2 Luer Activated Valves and a male Luer Lock adapter; Baxter Health | The extension sets contain microbore female luers that may crack during use, resulting in leakage of medication or incomplete delivery of medication. | accessdata.fda.gov |
| December 13, 2005 | 34096 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pumps; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A., Made in Singapore; product codes 2M8151, 2M8151R, BRM8151(Brazilian Port | Interruption of therapy due to battery undercharging, the generation of air-in-line alarms due to IV administration set tugging, and gearbox wear; and underinfusion due to misalignment of the pump head components. | accessdata.fda.gov |
| November 14, 2005 | 34020 | Not yet classified | Terminated | Baxter 6060 Multi-Therapy Infusion Pump, product codes 2M9832, 2M9832P and 2M9832R, and Sabratek 6060 Homerun Infusion Pumps, product codes 606000, 606000-40, 606000-40L, and 606000-40I; Manufactured by an affiliate of B | Failures within the PCA profile as well as incidents resulting in interruptions of therapy in various profiles. | accessdata.fda.gov |
| November 7, 2005 | 33999 | Not yet classified | Terminated | Baxter 6060 Multi-Therapy Infusion Pump, product codes 2M9832, 2M9832P and 2M9832R, and Sabratek 6060 Homerun Infusion Pumps, product codes 606000, 606000-40, 606000-40L, and 606000-40I; Manufactured by an affiliate of B | Possible shorting of some printed circuit boards could result in a possible interruption of therapy or cause the pump to fail the Power-On Self Test. | accessdata.fda.gov |
| October 27, 2005 | 33916 | Not yet classified | Terminated | Baxter I-Pump Pain Management System infusion pump, product codes 2L3107, 2L3107K and 2L3107R, Baxter Healthcare Corporation, Deerfield, IL 60015 | When infusing at flow rates below 0.5 mL/hr, the upstream occlusion alarm of the pumps may not detect the occlusion. | accessdata.fda.gov |
| August 29, 2005 | 33250 | Not yet classified | Terminated | Baxter''s Patient Care System (BPCS) software, Pharmacy Management - Inpatient - product code 2M5013 and Point of Care - product code 2M5014; Baxter Healthcare Corporation, 1 Baxter Parkway, Deerfield, IL 60015, USA, mad | If an administrative user modifies any of the seven pre-defined Monitoring Parameters when they are attached to a medication in the drug file, a Point of Care end user will be unable to enter monitoring parameter results on the handheld. | accessdata.fda.gov |
| August 17, 2005 | 33032 | Not yet classified | Terminated | Epidural Infusion Pumps sold under the following labels; a) Baxter 6060E Epidural Infusion Pump, product code 2L9351, 2L9351P and 2L9351R; Manufactured by an affiliate of Baxter Healthcare Corp., Deerfield, IL 60013 USA, | Potential overinfusion in the Auto-Ramp mode with software versions 3.00 or higher | accessdata.fda.gov |
| August 3, 2005 | 32812 | Not yet classified | Terminated | Baxter Interlink System Non-DEHP Y-Type Catheter Extension Set, product code 2N3371; An Rx sterile, nonpyrogenic fluid pathway, 5.7'', 0.8 mL Vol., with 2 injection sites and a male Luer Lock adapter; Baxter Healthcare C | The extension sets contain microbore female luers that may crack during use, resulting in leakage of medication or incomplete delivery of medication. | accessdata.fda.gov |
| July 20, 2005 | 32678 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pumps; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A., Made in Singapore; product codes 2M8151, 2M8151R, 2M8161, 2M8161R | A hardware problem can cause internal communications errors which halt therapies, generate alarms and communication failure codes. | accessdata.fda.gov |
| July 6, 2005 | 32589 | Not yet classified | Terminated | Baxter Healthcare Corporation, Medication Delivery Division, Syndeo PCA Syringe Pump, product codes 2L3113 and 2L3113R | During an infusion in the 'Basal + PCA' or 'PCA only' modes, the SYNDEO pump may generate false Service Code 919 or Service Code 920, which will cause the pump to stop the infusion. Also, while attempting to turn on the device by pressing the On/Off key, the pump may not power up properly. | accessdata.fda.gov |
| July 6, 2005 | 32588 | Not yet classified | Terminated | Baxter Interlink System Minivolume Extension Set, product code 1C8290; 11'', 0.86 mL Vol., with 2 injection sites and a male Luer Lock adapter; Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A. | Leaks and disconnection between the bifurcated Y-site and the set tubing may occur and result in underdelivery of medication, blood loss, and a breach of the sterile fluid pathway. | accessdata.fda.gov |
| June 16, 2005 | 32449 | Not yet classified | Terminated | Baxter''s Patient Care System (BPCS) software, composed of Pharmacy Management - Inpatient - product code 2M5013, Point of Care - product code 2M5014 and Management Reports - product code 2M5015; Baxter Healthcare Corpor | If a pharmacy end user alters the Administration Unit of Measure (AUOM) of an ordered drug, the AUOM will display incorrectly on the Medication Administration Record for the patient, possibly leading to medication errors. | accessdata.fda.gov |
| June 13, 2005 | 32254 | Not yet classified | Terminated | Baxter 6060 Multi-Therapy Infusion Pump, product code 2M9832, 606000-40, 606000-40L, 606000-40I; Manufactured by an affiliate of Baxter Healthcare Corp., Deerfield, IL 60013 USA, made in Singapore | There is an overinfusion condition in the Intermittent mode where the pump may continue to deliver at the higher dose rate instead of switching to the lower keep open rate once the first dose is completed. | accessdata.fda.gov |
| May 31, 2005 | 32191 | Not yet classified | Terminated | Baxter Interlink System Huber Needle Extension Set; a sterile 10'' fluid pathway with an Interlink Y-Injection Site and 3/4'' x 22 gauge needle; Manufactured for Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A.; | Some of the product code 2N3709 extension sets with Y-injections sites were placed in packages labeled as product code 2N3703 extension sets which do not have Y-injection sites. | accessdata.fda.gov |
| May 6, 2005 | 31992 | Not yet classified | Terminated | Baxter Auto Syringe AS50 Infusion Pump, product code 1M8550; Baxter Healthcare Corporation, Medication Delivery Division, Deerfield, IL 60015 U.S.A. | A 'Check Flange' alarm may occur even though the syringe has been properly loaded into the AS50 Infusion Pump. The false alarm may occur during the syringe loading process or while an infusion is running. Also, the occlusion detection and alarm may be delayed when the pumps are used with larger volume syringes at low flow rates. | accessdata.fda.gov |
| May 4, 2005 | 31969 | Not yet classified | Terminated | Baxter Sabraset 6060 Administration Set with Pre-attached 250 mL Bag and Cassette, product code 560500-250; Manufactured for Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A., Made in Mexico | The inlet and outlet lines of the administration set may be reversed, which would result in reverse flow. | accessdata.fda.gov |
| May 3, 2005 | 31965 | Not yet classified | Terminated | Baxter Flo-Gard 6201 Volumetric Infusion Pump, catalog #2M8063, 2M8063R (refurbished), 2M8063G (global), 2M8063U, 2M8063F, 2M8063A, 2M8063D & 2M8063B; Baxter Healthcare Corporation, Deerfield, IL 60015 | The mounting screws of the pole clamp may come loose, allowing the pole clamp assembly to detach from the rear pump housing, if they are not maintained on at least an annual basis. | accessdata.fda.gov |
| April 21, 2005 | 31800 | Not yet classified | Terminated | Baxter Interlink System Continu-Flo Solution Set with Large Bore 4-Way Stopcock Extension Set, 10 drops/mL, product code 3C0062s; a sterile, nonpyrogenic fluid pathway for administration of IV fluids; Manufactured by an | There is an unsecure connection between the male Luer and the stopcock on the I.V. extension set. | accessdata.fda.gov |
| March 28, 2005 | 31491 | Not yet classified | Terminated | Baxter Spinal Anesthesia Trays; sterile, single use only procedure trays that contain BD 25G x 8.9 cm (3-1/2'') Whitacre Spinal Needles; Assembled by Baxter Healthcare Corporation, Deerfield, IL 60015 | The anesthesia trays contain BD 25G Spinal Needles which which have leakage at the plastic hub of the needle. | accessdata.fda.gov |
| March 17, 2005 | 31469 | Not yet classified | Terminated | Buretrol Solution Sets, a sterile fluid pathway of various lengths, 60 drops/mL, with 150 mL Burette Ball Valve, 2 injection sites and male luer lock adapter; Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A | The Buretrol solution sets are currently labeled as acceptable for use with the Colleague Volumertric Pump, but there is a potential for a non-detection of an upstream occlusion under certain conditions. | accessdata.fda.gov |
| March 15, 2005 | 31490 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pumps; Baxter Healthcare Corporation, I.V. Systems Division, Deerfield, IL 60015 U.S.A., Made in Singapore; product codes 2M8151, 2M8151R, 2M8161, 2M8161R | The pumps may experience inadvertent power off, external communications port failures and electronic pump failure codes 402, 403, 533, 535, 599, 810:04 and 810:11. | accessdata.fda.gov |
| March 10, 2005 | 31467 | Not yet classified | Terminated | Clinician Workstation Software, product code 2M5042 | The medication administration results displayed in the 'View Results' link may be inaccurate. | accessdata.fda.gov |
| March 3, 2005 | 31275 | Not yet classified | Terminated | Baxter PosiFlow Access Device for IV Access; product code 2N9050; a single use, sterile device with PosiFlow Positive Displacement Feature and Male Luer Lock Adapter, 0.06 mL; Baxter Healthcare Corp., Deerfield, IL 60015 | Inadequate directions for use resulting in fluid leaks, valves sticking in the open position, and flow output restriction. | accessdata.fda.gov |
| March 2, 2005 | 31266 | Not yet classified | Terminated | Configuration Transfer Cable; an accessory for the Colleague Infusion pump, Product code 2M8155; Baxter Healthcare Corporation, Deerfield, IL | The Configuration Tranfer Cable for the Colleague Infusion Pumps has incorrect thumb screws on it., not allowing firm connections of the cable to the pump to transfer data to the biomedical engineer's diagnostic device. | accessdata.fda.gov |
| February 28, 2005 | 31245 | Not yet classified | Terminated | Baxter ClearLink Intravenous (IV) Solution Sets and Extension Sets that have a ClearLink luer activated valve for IV access, which allows the administration of medications/solutions with a needleless luer syringe; Baxter | Possible occlusion of the Clearlink injection site valve due to inadequate silicone lubrication of the slit in the upper seal of the valve. | accessdata.fda.gov |
| February 25, 2005 | 31188 | Not yet classified | Terminated | Baxter Colleague Single Channel Volumetric Infusion Pumps; Baxter Healthcare Corporation, I.V. Systems Division, product codes 2M8151, 2M8151R, 2M8161, 2M8161R | Swelling of the sealed lead-acid batteries in the infusion pump can cause internal pump damage, and excessive battery discharge can damage the batteries if the pump is left on battery power for an extended period of time after teh Battery Depleted alarm occurs. | accessdata.fda.gov |
| February 10, 2005 | 31191 | Not yet classified | Terminated | Baxter I-Pump Pain Management System infusion pump, product codes 2L3107, 2L3107K and 2L3107R, Baxter Healthcare Corporation, Deerfield, IL 60015 | Potential failures of the pump due to upstream occlusion alarms, electro-static discharge, system error 32 or 33, history printout errors and fluid volume in 'Use Previous Rx' when priming through the pump. | accessdata.fda.gov |
| January 20, 2005 | 31019 | Not yet classified | Terminated | Baxter Posiflow Access Device for IV Access; product code 2N9050; a single use, sterile device with Posiflow Positive Displacement Feature and Male Luer Lock Adapter, 0.06 mL; Baxter Healthcare Corp., Deerfield, IL 60015 | Product older than three years may not operate as intended. | accessdata.fda.gov |
| December 20, 2004 | 30715 | Not yet classified | Terminated | Anesthesia Set, product code 2C9216; a sterile fluid path consisting of a 72'' long PVC with DEHP tubing with a green stripe, inner diameter of 0.040'', priming volume 1.7 mL, with a luerlock connector with fixed collar; | The anesthesia set was incorrectly labeled as an anti-siphon set, but the set does not contain an anti-siphon component. | accessdata.fda.gov |
| December 20, 2004 | 30714 | Not yet classified | Terminated | Logix-CM Compounder Software, catalog 2M8400; Baxter Healthcare Corporation, Medication Delivery System, Round Lake, IL 60073 | Logix-CM software version 3.0.4 has not completed its official release process. | accessdata.fda.gov |
| December 8, 2004 | 30609 | Not yet classified | Terminated | Logix-CM Compounder Software, catalog 2M8400; Baxter Healthcare Corporation, Medication Delivery System, Round Lake, IL 60073 | A software anomaly in the Logix CM software could result in a drug mixture being compounded without one of the ingredients if two drugs have the same indentifier in Logix and another order entry program being used with the Logix software. | accessdata.fda.gov |
| November 19, 2004 | 30506 | Not yet classified | Terminated | Baxter labeled 6060 Solution Sets with AutoClamp; For use with model 6060 multi-therapy pumps only; a prescription, sterile, non-pyrogenic fluid pathway; Manufactured by an affiliate of Baxter Healthcare Corporation, Dee | A missing platen assembly in the cassette of the solution sets results in the infusion pump being unable to occlude the tubing of the set. This can lead to free-flow of the solution and a possible overdose of medication to the patient. | accessdata.fda.gov |
| November 4, 2004 | 30381 | Not yet classified | Terminated | Colleague Single Channel Volumetric Infusion Pumps, product code 2M8151and 2M8151R; Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A., Made in Singapore; monochrome display screen | A software anomaly causes a failure alarm code 12:303 which audibly alarms and stops the function of all channels in use. This causes an interruption in therapy, which may result in a risk to the patient. | accessdata.fda.gov |
| September 1, 2004 | 29958 | Not yet classified | Terminated | Baxter Lock Box for 100 mL or 250 mL Bag Set, for use with 6060 Pump Family; Baxter product code 2L9354 and previously marketed by Sabratek under product code 606194, Baxter Healthcare Corporation, Deerfield, IL 60015 | The pump may free-flow if the door to the 6060 pump is not closed prior to loading the pump in to the lock box. The pump will alarm 'Door Open', but if the pump is turned off to silence the alarm while remaining in the lock box, the fluid will free-flow. | accessdata.fda.gov |
| April 30, 2004 | 29017 | Not yet classified | Terminated | Compounding Brochure titled ''Nutrition Compounding Simplified'', Lit #800415, print date January 2002; the brochure is applicable to the Automix Plus High Speed Compounder System, product 2M8075, the Automix High Speed | The promotional material for the Automix/Accusource and Micromix compounders and Micromix Compounder Implementation Guide contain an incomplete accuracy statement regarding the delivery of each ingredient by the compounders. | accessdata.fda.gov |
| April 28, 2004 | 29014 | Not yet classified | Terminated | Baxter Clearlink Intravenous (IV) Delivery System; the system consists of solution sets, extension sets and blood sets that have a luer activated valve for IV access, which allows the administration of medications/soluti | Inadequate directions for use may have contributed to an increase in infection rates at a small number of customers beginning use of the Clearlink needleless device. | accessdata.fda.gov |
| April 26, 2004 | 28921 | Not yet classified | Terminated | Clintec Micromix Compounder, an I.V. solution compounder; Baxter Healthcare Corporation, Clintec Nutrition Division, Deerfield, IL 60015 USA; product code 2M8290 - 1.0 mL accuracy, and product code 2M8290L - less than 1. | The Micromix compounder may have ingredient delivery outside of the stated accuracy limits if the Vlier pin is not properly adjusted | accessdata.fda.gov |
| April 13, 2004 | 28824 | Not yet classified | Terminated | Colleague Single Channel Volumetric Infusion Pumps, product code 2M8151and 2M8151K (United Kingdom); Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A., Made in Singapore; monochrome display screen | Ink deterioration of the letters, numbers and symbols of the programming and pump channel keypads, which may impact the legibility of the keys over time. | accessdata.fda.gov |
| December 17, 2003 | 28037 | Not yet classified | Terminated | Baxter 6060 Multi-Therapy Infusion Pump, product code 2M9832; Manufactured by an affiliate of Baxter Healthcare Corp., Deerfield, IL 60013 USA, made in Singapore | Premature motor failure. | accessdata.fda.gov |
| December 16, 2003 | 28038 | Not yet classified | Terminated | Micromix BCR Compounder, product code 2M8297; a pharmacy automation device with a barcode reader used in preparation of parenteral solutions; Baxter Healthcare Corporation, Clintec Nutriiton Division, Deerfield, IL 60015 | The compounder may omit an ingredient during the compounding process. | accessdata.fda.gov |
| December 5, 2003 | 27896 | Not yet classified | Terminated | Baxter HomeChoice Automated PD Set with Lineo Connector, 4-prong, product codes R5C4479Q (English) and N5C4479Q (dual English/French label); Baxter Healthcare Corporation, Deerfield, IL 60015 USA; 30 units per case | Reports of loosening of the connections and disconnection of the device. | accessdata.fda.gov |
| October 30, 2003 | 27605 | Not yet classified | Terminated | CA Cellulose Acetate High Efficiency Hollow Fiber Dialyzers; Model CA 210, product code 5M1736; Distributed by Baxter Healthcare Corporation, Deerfield, IL 60015 USA, Made in Japan; 24 units per case | Use of the dialyzers may cause iritis (red-eye) patient reactions. | accessdata.fda.gov |
| July 16, 2003 | 26772 | Not yet classified | Terminated | Continu-Flo Solution Set, 10 drops/mL, 113'', 2 Luer Activated Valves, Male Luer Lock Adapter, catalog 2C9907; Baxter Healthcare Corporation, Deerfield, IL 60015 USA | There are possible pinholes or perforations in the set tubing, caused by damage that occurred during the packaging process. | accessdata.fda.gov |
| March 20, 2003 | 25818 | Not yet classified | Terminated | Baxter System 1000 Single Patient Hemodialysis Delivery System; Model SYS1000; all series 1000 instruments labeled as System 1000, AltraTouch 1000, Baxter Tina and Baxter Aurora; Baxter Healthcare Corporation, Deerfield, | The dialysis treatment may be run without the bicarbonate due to an undetected bicarbonate pump stall following a sodium change. | accessdata.fda.gov |
Compare with other makers
- All makers of Set, Administration, Intravascular
- All makers of Flowmeter, Blood, Cardiovascular
- All makers of Forceps
- All makers of Syringe, Piston
- All makers of Administrations Sets With Neuraxial Connectors
Updated August 7, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.