Data / Workplace safety / Delaware / Mitra QSR Kne, LLC
Mitra QSR Kne, LLC, Camden Wyoming, DE: 7 OSHA citations, $20,028 in penalties (2024)
OSHA recorded 1 inspection at Mitra QSR Kne, LLC, 344 Walmart Drive, Camden Wyoming, DE 19934, on November 15, 2024. 1 inspection ended in citations: 7 citations with $28,611 in initial penalties and $20,028 in current penalties. The latest citation was issued April 16, 2025.
SpecStream is the live web data engine for teams and agents. It reads OSHA inspections and citations from the US Department of Labor's enforcement data, and this page is that reading. Ask for the employers you check by industry, state or standard and new inspections and citations arrive in your sheet, CRM, Slack or agent as they are posted.
- Site
- 344 Walmart Drive, Camden Wyoming, DE 19934
- Industry
- 722513 Limited-Service Restaurants
- Ownership
- Private
- Employees at the site
- 15 (as recorded at the latest inspection)
- Inspections
- 1, of which 1 with citations
- Citations
- 7
- Penalties
- $28,611 initial, $20,028 current
Inspections
Every inspection OSHA opened at this site since November 3, 2021.
| Opened | Closed | Type | Scope | Focus | Citations | Current penalties | Source |
|---|---|---|---|---|---|---|---|
| November 15, 2024 | May 7, 2026 | Complaint | Partial | Safety | 7 | $20,028 | osha.gov |
Citations
One row for each citation, newest first. Gravity is OSHA's level of gravity for serious violations.
| Inspection opened | Standard cited | Standard title | Type | Gravity | Issued | Initial penalty | Current penalty | Source |
|---|---|---|---|---|---|---|---|---|
| November 15, 2024 | 1910.305(i)(2)(i) | Wiring methods, components, and equipment for general use | Serious | 5 | April 16, 2025 | $0 | $0 | osha.gov |
| November 15, 2024 | 1910.305(b)(3)(ii) | Wiring methods, components, and equipment for general use | Serious | 5 | April 16, 2025 | $13,005 | $9,104 | osha.gov |
| November 15, 2024 | 1910.157(e)(2) | Portable fire extinguishers | Serious | 5 | April 16, 2025 | $0 | $0 | osha.gov |
| November 15, 2024 | 1910.157(c)(1) | Portable fire extinguishers | Serious | 5 | April 16, 2025 | $0 | $0 | osha.gov |
| November 15, 2024 | 1910.39(b) | Fire prevention plans | Serious | 5 | April 16, 2025 | $0 | $0 | osha.gov |
| November 15, 2024 | 1910.38(b) | Emergency action plans | Serious | 5 | April 16, 2025 | $0 | $0 | osha.gov |
| November 15, 2024 | 1910.37(a)(4) | Maintenance, safeguards, and operational features for exit routes | Serious | 5 | April 16, 2025 | $15,606 | $10,924 | osha.gov |
Also on SpecStream
- OSHA citations in Delaware
- 29 CFR 1910.157, Portable fire extinguishers: all citations
- 29 CFR 1910.305, Wiring methods, components, and equipment for general use: all citations
- 29 CFR 1910.37, Maintenance, safeguards, and operational features for exit routes: all citations
Updated November 3, 2026. Read from US Department of Labor, OSHA enforcement data. Public domain (U.S. government work). Penalties are as OSHA records them on the date this page was read and can change after a contest or a settlement. Citations OSHA deleted are left out. Each row links to OSHA's own inspection record. This page uses US Department of Labor data and is not endorsed or certified by the US Department of Labor. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.