Data / Workplace safety / Ohio / Lacko Poured Walls, LLC
Lacko Poured Walls, LLC, Grove City, OH: 10 OSHA citations, $86,067 in penalties (2025)
OSHA recorded 1 inspection at Lacko Poured Walls, LLC, 3885 Mason Lane, Grove City, OH 43123, on March 26, 2025. 1 inspection ended in citations: 10 citations with $215,165 in initial penalties and $86,067 in current penalties. The latest citation was issued August 22, 2025.
SpecStream is the live web data engine for teams and agents. It reads OSHA inspections and citations from the US Department of Labor's enforcement data, and this page is that reading. Ask for the employers you check by industry, state or standard and new inspections and citations arrive in your sheet, CRM, Slack or agent as they are posted.
- Site
- 3885 Mason Lane, Grove City, OH 43123
- Industry
- 238110 Poured Concrete Foundation and Structure Contractors
- Ownership
- Private
- Employees at the site
- 70 (as recorded at the latest inspection)
- Inspections
- 1, of which 1 with citations
- Citations
- 10
- Penalties
- $215,165 initial, $86,067 current
Inspections
Every inspection OSHA opened at this site since November 3, 2021.
| Opened | Closed | Type | Scope | Focus | Citations | Current penalties | Source |
|---|---|---|---|---|---|---|---|
| March 26, 2025 | Planned | Partial | Safety | 10 | $86,067 | osha.gov |
Citations
One row for each citation, newest first. Gravity is OSHA's level of gravity for serious violations.
| Inspection opened | Standard cited | Standard title | Type | Gravity | Issued | Initial penalty | Current penalty | Source |
|---|---|---|---|---|---|---|---|---|
| March 26, 2025 | 1926.652(c)(3)(iii) | Requirements for protective systems | Other than serious | Not listed | August 22, 2025 | $0 | $0 | osha.gov |
| March 26, 2025 | 1926.652(a)(1) | Requirements for protective systems | Repeat | 10 | August 22, 2025 | $23,170 | $0 | osha.gov |
| March 26, 2025 | 1926.651(k)(1) | Specific excavation requirements | Repeat | 10 | August 22, 2025 | $23,170 | $11,585 | osha.gov |
| March 26, 2025 | 1926.651(c)(2) | Specific excavation requirements | Repeat | 10 | August 22, 2025 | $115,860 | $57,930 | osha.gov |
| March 26, 2025 | 1926.501(b)(15) | Duty to have fall protection | Serious | 5 | August 22, 2025 | $8,276 | $4,138 | osha.gov |
| March 26, 2025 | 1926.651(d) | Specific excavation requirements | Serious | 10 | August 22, 2025 | $11,585 | $0 | osha.gov |
| March 26, 2025 | 1926.102(a)(1) | Eye and face protection | Serious | 5 | August 22, 2025 | $8,276 | $0 | osha.gov |
| March 26, 2025 | 1926.100(a) | Head protection | Serious | 5 | August 22, 2025 | $8,276 | $4,138 | osha.gov |
| March 26, 2025 | OSH Act section 5(a)(1) | General duty clause | Serious | 5 | August 22, 2025 | $8,276 | $4,138 | osha.gov |
| March 26, 2025 | OSH Act section 5(a)(1) | General duty clause | Serious | 5 | August 22, 2025 | $8,276 | $4,138 | osha.gov |
Also on SpecStream
- All OSHA citations in Foundation, Structure, and Building Exterior Contractors in Ohio
- OSHA citations in Ohio
- 29 CFR 1926.651, Specific excavation requirements: all citations
- 29 CFR 1926.652, Requirements for protective systems: all citations
- 29 CFR 1926.100, Head protection: all citations
Updated November 3, 2026. Read from US Department of Labor, OSHA enforcement data. Public domain (U.S. government work). Penalties are as OSHA records them on the date this page was read and can change after a contest or a settlement. Citations OSHA deleted are left out. Each row links to OSHA's own inspection record. This page uses US Department of Labor data and is not endorsed or certified by the US Department of Labor. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.