Data / Medical devices / United States / ZOLL Manufacturing Corporation
ZOLL Manufacturing Corporation: FDA-registered device maker in Pittsburgh, PA, United States, 3 510(k) clearances and 1 PMA approval
ZOLL Manufacturing Corporation is registered with the FDA (registration 3008642652) in Pittsburgh, PA, United States. It lists 5 device types. The FDA files 3 510(k) clearances and 1 PMA approval under its listings, the newest dated December 19, 2019. 6 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3008642652
- Address
- 121 Gamma Dr, Pittsburgh, PA, United States, 15238
- Owner or operator
- ZOLL Manufacturing Corporation (9045611)
- Roles
- Manufacturer
- First device listed
- November 8, 2007
- Registered through
- 2026
- Brand names listed
- LifeVest Wearable Defibrillator, ZOLL Arrhythmia Management System, ZOLL ECG Analysis Software, uCor Heart Failure and Arrhythmia Management System
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Detector And Alarm, Arrhythmia | DSI | 2 | Manufacturer | accessdata.fda.gov |
| Electrocardiograph | DPS | 2 | Manufacturer | accessdata.fda.gov |
| Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | MHX | 2 | Manufacturer | accessdata.fda.gov |
| Plethysmograph, Impedance | DSB | 2 | Manufacturer | accessdata.fda.gov |
| Wearable Automated External Defibrillator | MVK | 3 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| December 19, 2019 | K190939 | ZOLL Arrhythmia Management Sysyem | MHX | Substantially Equivalent | Zoll Manufacturing Corporation | accessdata.fda.gov |
| January 28, 2019 | K182093 | ZOLL ECG Analysis Software | DPS | Substantially Equivalent | Zoll Manufacturing Corporation | accessdata.fda.gov |
| May 11, 2018 | K172510 | µCor Heart Failure and Arrhythmia Management System | MHX | Substantially Equivalent | Zoll Manufacturing Corporation | accessdata.fda.gov |
PMA approvals
Premarket approvals this establishment lists, with the supplements the FDA has decided since.
| Approved | PMA number | Device | Product code | Supplements | Latest decision | Source |
|---|---|---|---|---|---|---|
| December 18, 2001 | P010030 | WEARABLE CARDIOVERTER DEFIBRILLATOR (WCD) 2000 LIFEVEST | MVK | 198 | October 6, 2026 | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| September 12, 2017 | 78926 | Class II | Terminated | LifeVest Wearable Defibrillator Model 4000, Product Number 10A0988-A01. The LifeVest system is indicated for patients 18 years of age and older who are at risk for sudden cardiac arrest and are not candidates for or refu | Incorrect service code for properly catching critical defects during self-check. Potential for defibrillation shock failure | accessdata.fda.gov |
| September 24, 2010 | 56957 | Not yet classified | Terminated | Model 4000 Monitor component of the LifeVest Wearable Defibrillator | The response button function may become intermittent. This can result in the device not progressing beyond the response button test during startup, which may prevent a conscious patient from delaying a treatment shock. | accessdata.fda.gov |
| October 21, 2008 | 50119 | Not yet classified | Terminated | Monitor portion of the LifeVest device - specifically the Defibrillator printed circuit assembly (PCA) within the monitor. The LifeVest is indicated for adult patients who are at risk for sudden cardiac arrest and are no | The charging circuit will not shut down properly. | accessdata.fda.gov |
| September 14, 2007 | 44942 | Not yet classified | Terminated | Battery Pack portion of the LifeVest device. The LifeVest is a wearable cardioverter defibrillator worn by a patient at risk for sudden cardiac arrest (SCA). | Possible malfunction of the battery pack. A significant electrostatic discharge (ESD) can cause the battery pack to malfunction. The malfunction causes the battery pack to discharge more rapidly and prevents the pack from recharging. | accessdata.fda.gov |
| April 27, 2007 | 37869 | Not yet classified | Terminated | Electrode Belt, component of the LifeVest Wearable Defibrillator, Product number 10A0889-A01. Specifically the 3 Therapy Electrode Pads attached to the Electrode Belt. | The electrodes do not properly release conductive gel | accessdata.fda.gov |
| January 10, 2003 | 25387 | Not yet classified | Terminated | Life Vest (WCD 3000) Electrode Belt. Wearable Cardioverter Defibrillator. Product label 20A0051-FI. | Wires may break or pull out, causing device to malfunction | accessdata.fda.gov |
Compare with other makers
- All makers of Electrocardiograph
- All makers of Wearable Automated External Defibrillator
- All makers of Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
- All makers of Plethysmograph, Impedance
- All makers of Detector And Alarm, Arrhythmia
Updated October 6, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.