Data / Medical devices / United States / ZimVie US Corp LLC

ZimVie US Corp LLC: FDA-registered device maker in Palm Beach Gardens, FL, United States, 101 510(k) clearances

ZimVie US Corp LLC is registered with the FDA (registration 1038806) in Palm Beach Gardens, FL, United States. It lists 9 device types. The FDA files 101 510(k) clearances under its listings, the newest dated October 23, 2024. 60 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1038806
Address
4555 Riverside Drive, Palm Beach Gardens, FL, United States, 33410
Owner or operator
ZimVie US Corp LLC (1038806)
Roles
Complaint file establishment, Contract manufacturer, Manufacturer, Manufacturer for export, Repackager or relabeler, Specification developer
First device listed
December 29, 1993
Registered through
2026
Brand names listed
3i T3 Ex Hex Parallel Walled Implant, 3i T3 Ex Hex Tapered Implant, 3i T3 Non-Platform Switched Parallel Walled Implant, 3i T3 Non-Platform Switched Tapered Implant, 3i T3 Parallel Walled Implant, 3i T3 Short External Hex Parallel Walled Implant, 3i T3 Short External Hex Parallel Walled Implant with DCD, 3i T3 Tapered Implant and more

Devices it lists

DeviceProduct codeClassRoleSource
Abutment, Implant, Dental, EndosseousNHA2Complaint file establishment, Contract manufacturer, Manufacturer, Manufacturer for export, Specification developeraccessdata.fda.gov
Accessories, Implant, Dental, EndosseousNDP1Manufacturer, Repackager or relabeler, Specification developeraccessdata.fda.gov
Attachment, Precision, AllEGG1Specification developeraccessdata.fda.gov
Bone Grafting Material, Human SourceNUN2Specification developeraccessdata.fda.gov
Bur, DentalEJL1Manufacturer for exportaccessdata.fda.gov
Implant, Endosseous, Root-FormDZE2Complaint file establishment, Manufacturer, Repackager or relabeler, Specification developeraccessdata.fda.gov
Resin, Denture, Relining, Repairing, RebasingEBI2Complaint file establishmentaccessdata.fda.gov
TemplateHWT1Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Tray, Surgical, InstrumentFSM1Manufacturer, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance. Newest 100 of 101.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
October 23, 2024K241753Immediate Molar ImplantsDZESubstantially EquivalentBiomet 3i, LLCaccessdata.fda.gov
September 14, 2022K220978TSX ImplantsDZESubstantially EquivalentBiomet 3i, LLCaccessdata.fda.gov
March 28, 2022K213672T3 Pro ImplantsDZESubstantially EquivalentBiomet 3i, LLCaccessdata.fda.gov
December 21, 2021K212730BellaTek Encode Emergence Healing AbutmentsNHASubstantially EquivalentBiomet 3i, LLCaccessdata.fda.gov
December 9, 2019K192522TSV BellaTek Express and BellaTek Flex AbutmentsNHASubstantially EquivalentBiomet 3i, LLCaccessdata.fda.gov
July 2, 2019K183138Certain BellaTek Express and BellaTek Flex AbutmentsNHASubstantially EquivalentBiomet 3iaccessdata.fda.gov
December 13, 2017K173374TSV BellaTek Encode Healing AbutmentsNHASubstantially EquivalentBiomet 3iaccessdata.fda.gov
November 20, 2015K1505713i T3 Short ImplantsDZESubstantially EquivalentBiomet 3iaccessdata.fda.gov
June 25, 2015K143505Zimmer Patient-Specific Abutment, Internal Hex, TitaniumNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
May 1, 2015K143528Zimmer Cast-to Gold Abutments for the 3.1mmD Dental Implant SystemNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
January 21, 2015K142572Zimmer Zfx Abutment for Zimmer 3.1mmD Implant SystemNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
October 28, 2014K142082ZIMMER 3.1MM DENTAL IMPLANT;2.9MM ANGLED ABUTMENT;STRAIGHT HEX, 2.9MM CONTOUR ABUTEMENTDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
June 16, 2014K140570CHAIRSIDE ATTACHMENT PROCESSING MATERIALEBISubstantially EquivalentZest Anchors, LLCaccessdata.fda.gov
March 4, 2014K133339ZIMMER DENTAL TAPERED SCREW VENT T IMPLANT, HA COATED;ZIMMER DENTAL TAPERED SCREW-VENT M IMPLANT, HA COATEDDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
January 8, 2014K1330493I T3(R) EXTERNAL HEX DENTAL IMPLANTSDZESubstantially EquivalentBiomet 3iaccessdata.fda.gov
November 19, 2013K132258ZIMMER DENTAL TRABECULAR METAL IMPLANT SYSTEMDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
July 30, 2013K130949CP4 OSSEOTITE CERTAIN DENTAL IMPLANTSDZESubstantially EquivalentBiomet 3iaccessdata.fda.gov
January 30, 2013K122300T3 DENTAL IMPLANTDZESubstantially EquivalentBiomet 3iaccessdata.fda.gov
November 8, 2012K120873ZIMMER ZFX ABUTMENT FOR NOBEL REPLACE IMPLANT SYSTEMNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
September 11, 2012K120776ABUTMENT FOR COMPETITIVE IMPLANT NOBEL ACTIVE CONNECTIONNHASubstantially EquivalentBiomet 3iaccessdata.fda.gov
August 30, 2012K113753ZIMMER DENTAL TAPERED SCREW-VENT XDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
January 23, 2012K113092ZIMMER CONTOUR PROVISIONAL COPINGNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
January 20, 2012K113645REGENEROSS ALLOGRAFT PLUS MINERLIZEDNUNSubstantially EquivalentBiomet Interpore Crossaccessdata.fda.gov
January 13, 2012K112730ABUTMENT FOR COMPETITIVE IMPLANT STRAUMANN BONE LEVEL CONNECTIONNHASubstantially EquivalentBiomet 3iaccessdata.fda.gov
December 14, 2011K112160TAPERED SCREW-VENT X IMPLANTDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
December 8, 2011K111853ANGLED TAPERED ABUTMENTNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
December 6, 2011K111889ZIMMER DENTAL TAPERED SCREW-VENT M IMPLANTDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
November 18, 2011K111216OSSEOTITE 2 DENTAL IMPLANTSDZESubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
September 1, 2011K110565ABUTMENTS FOR COMPETITIVE IMPLANT SYSTEMS-NOBEL REPLACENHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
August 11, 2011K111852ANODIZED HEALING COLLARNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
April 1, 2011K100724OSSEOTITE II MODEL XIFOSSXXXDZESubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
March 11, 2011K101608BIOMET 3I PATIENT SPECIFIC DENTAL ABUTMENTS-ENCODE ABUTMENTSNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
March 11, 2011K101607BIOMET 3I PATIENT SPECIFIC DENTAL ABUTMENTS - ENCODE ABUTMENTSNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
December 3, 2010K102209ENCODE PATIENT SPECIFIC ABUTMENTNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
November 8, 2010K101582CAM STRUCTSURE BARSNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
October 1, 2010K101880TAPERED SCREW-VENT T IMPLANT, TAPERED SCREW-VENT P IMPLANTDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
September 14, 2010K101977TAPERED SCREW-VENT T IMPLANTDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
December 15, 2009K0931643.25 SPLINE TWIST IMPLANT, HA COATEDDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
November 30, 2009K092341LOW PROFILE ABUTMENTS - INTERNAL AND EXTERNAL CONNECTIONNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
November 3, 2009K092377PLASTIC TEMPORARY ABUTMENTS, MODELS: PT341S, PT344S, PT341A, PT344A, PT451S, PT454S, PT451A, PT454A, PT561S, PT564SNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
October 30, 2009K092403TI PREPABLE ABUTMENT, MODEL 1618, 1619, 1620NHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
April 7, 2009K090723HEX-LOCK SHORT ABUTMENT, MODEL SA341, SA342, SA451, SA452, SA561, SA562 SHORT HEALING CAP, MODEL SAHEAL4, SAHEAL5,NHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
December 23, 2008K083474ZIMMER ANGLED CONTOUR ZIRCONIA ABUTMENTNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
December 19, 2008K082639ZIMMER DENTAL TAPERED SWISSPLUS IMPLANTSDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
September 25, 2008K080164ZIMMER PATIENT-SPECIFIC CERAMIC ABUTMENTNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
July 21, 2008K080864CAM STRUCTSURE PRECISION MILLED BARSNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
December 20, 2007K072642BIOMET 3I DENTAL ABUTMENTS AND RESTORATIVE COMPONENTSNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
October 4, 2007K072589TAPERED SCREW-VENT IMPLANT, 4.1MM, MODELS: TSV4B8, B10, B11, B13 AND B16, TSV4H8, H11, H13 AND H16DZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
September 20, 2007K071439ZIMMER PATIENT-SPECIFIC ABUTMENT, INTERNAL HEX, TITANIUMDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
August 30, 2007K071551QUICKBRIDGE TM CYLINDER AND CAPNHASubstantially EquivalentBiomet 3i, Inc.accessdata.fda.gov
May 30, 2007K071235ZIMMER ONE PIECE IMPLANT, 3.0MM ANGLED, MODELS ZOP30A10, ZOP30A11 AND ZOP30A13DZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
May 14, 2007K070147INTERGRO ORALNUNSubstantially EquivalentBiomet 3iaccessdata.fda.gov
April 30, 2007K0633413I OSSEOTITE CERTAIN DENTAL IMPLANTSDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
April 24, 2007K063286OSSEOTITE; OSSEOTITE NT; XP; TG OSSEOTITEDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
March 20, 2007K063403CONICAL ANGLED ABUTMENTNHASubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
February 23, 2007K061629CERTAIN PREVAIL DENTAL IMPLANTDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
October 12, 2006K061847ZIMMER CONTOUR CERAMIC ABUTMENT, MODELS ZRA341S, ZRA342S, KRA451S, ZRA452SNHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
September 8, 2006K061410SCREW-VENT IMPLANT SYSTEM, SV;TAPERED SCREW -VENT IMPLANT SYSTEM, TSV;ADVENT IMPLANT SYSTEM,AV;ZIMMER ONE-PIECE IMPLANTDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
July 21, 2006K061969PREFORMANCE POSTS AND TEMPORARY CYLINDERSNHASubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
May 17, 2006K060880ZIMMER DENTAL ONE PIECE TAPERED ABUTMENT, MODELS TAC1, TACW1, TA5C1NHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
February 27, 2006K060291PREFORMANCE TEMPORARY CYLINDERNHASubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
February 1, 2006K053170PREFORMANCE POSTSNHASubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
January 23, 2006K052997ZIMMER DENTAL ONE-PIECE IMPLANTDZESubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
October 20, 2005K052648MODIFICATION TO 3I PATIENT-SPECIFIC DENTAL ABUTMENTS AND OVERDENTURE BARSNHASubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
October 13, 2005K052600ZIMMER DENTAL HEX-LOCK PREPARED ABUTMENT (STRAIGHT & ANGLED)NHASubstantially EquivalentZimmer Dental, Inc.accessdata.fda.gov
September 15, 2005K0514613I OSSEOTITE DENTAL IMPLANTSDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
November 13, 2002K014050HEX-LOCK TEMPORARY ABUTMENTDZESubstantially EquivalentSulzer Dental, Inc.accessdata.fda.gov
September 19, 2002K0221133I DENTAL IMPLANT ACCESSORIESDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
January 18, 2002K0134943.75MM AND 5.0MM SPLINE TWIST IMPLANTDZESubstantially EquivalentSulzer Dental, Inc.accessdata.fda.gov
November 19, 2001K013227SCREW VENT IMPLANT; TAPERED SCREW VENT IMPLANTDZESubstantially EquivalentSulzer Dental, Inc.accessdata.fda.gov
September 28, 2001K0129113I LOCATER ABUTMENT SYSTEMDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
June 25, 2001K011245ADVENT IMPLANT SYSTEM, SWISS PLUS IMPLANT SYSTEMDZESubstantially EquivalentSulzer Dental, Inc.accessdata.fda.gov
May 21, 2001K011028SCREW-VENT DENTAL IMPLANT SYSTEMDZESubstantially EquivalentSulzer Dental, Inc.accessdata.fda.gov
May 15, 2001K011038TAPER-LOCK DENTAL IMPLANT SYSTEMDZESubstantially EquivalentSulzer Dental, Inc.accessdata.fda.gov
January 19, 2001K010073SPLINE DENTAL IMPLANT SYSTEMDZESubstantially EquivalentSulzer Calcitek, Inc.accessdata.fda.gov
December 8, 2000K002614ADVENT IMPLANT SYSTEMDZESubstantially EquivalentCore-Vent Corp.accessdata.fda.gov
October 30, 2000K002188SWISSPLUS IMPLANT SYSTEM, MODEL SPWB 8,10,12,14/OPH20/SMPR, SPB 8,10,12,14/OP3.5D/OPAR,OPB 8,10,12,14/OP2.3D/OP2.8D,DZESubstantially EquivalentCore-Vent Corp.accessdata.fda.gov
June 21, 2000K001786TEMPORARY GINGIVAL CUFF AND IMPRESSION POST AND IMPLANT ANALOGDZESubstantially EquivalentSulzer Calcitek, Inc.accessdata.fda.gov
September 22, 1998K982305SPLINE DENTAL IMPLANT SYSTEM-TEMPORARY ABUTMENTDZESubstantially EquivalentSulzer Calcitek, Inc.accessdata.fda.gov
August 26, 1997K9724443I INNOVATIVE IMPLANTS AND COVER SCREWSDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
June 23, 1997K970752SPLINE ENGAGING SHOULDERED ABUTMENT SYSTEMDZESubstantially EquivalentSulzer Calcitek, Inc.accessdata.fda.gov
August 29, 1996K962106SPLINE DENTAL IMPLANT SYSTEMSDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
March 8, 1996K9556195.0MM SPLINE ENDOSSEOUS DENTAL IMPLANT SYSTEMSDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
February 8, 1996K960021CALCITEK HA-COATED ENDOSSEOUS DENTAL IMPLANT SYSTEMSDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
February 8, 1996K943604INTEGRAL V BIOINTEGRATED DENTAL IMPLANT SYSTEMDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
December 21, 1995K953101PARAGON IMPLANT SYSTEMDZESubstantially EquivalentCore-Vent Bio-Engineering, Inc.accessdata.fda.gov
May 16, 1995K944327INTEGRAL VI BIOINTEGRATED DENTAL IMPLANT SYSTEMDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
May 27, 1994K932123IMPLANT INNOVATION PRE-ANGLED ABUTMENT SYSTEMDZESubstantially EquivalentImplant Innovations International, Inc.accessdata.fda.gov
April 26, 1994K933969TAPERED ABUTMENT AND RELATED COMPONENTSDZESubstantially EquivalentImplant Innovations, Inc.accessdata.fda.gov
November 5, 1993K932274INTEGRAL III DENTAL IMPLANT ABUTMENTDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
February 11, 1992K912059PRE-ANGLED ABUTMENTSDZESubstantially EquivalentCore-Vent Corp.accessdata.fda.gov
February 20, 1991K900179SCREW-VENT ENDOSSEOUS IMPLANT ABUTMENTSDZESubstantially EquivalentCore-Vent Corp.accessdata.fda.gov
February 11, 1991K900694CASTABLE ABUTMENTSDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
December 17, 1990K902969SCREW-VENT ENDOSSEOUS HA COATED DENTAL IMPLANTSDZESubstantially EquivalentCore-Vent Corp.accessdata.fda.gov
November 9, 1990K904228OSSEODENT DENTAL ATTACHMENTS (NON-ANGLED)DZESubstantially EquivalentCollagen Corp.accessdata.fda.gov
June 28, 1990K900549INTEGRAL PLUS BIOINTEGRATED DENTAL IMPLANT SYSTEMDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
June 22, 1990K900545O-RING PROSTHETIC ATTACHMENT DEVICEDZESubstantially EquivalentCalcitek, Inc.accessdata.fda.gov
October 10, 1989K891613OVERDENTURE ATTACHMENTDZESubstantially EquivalentImplant Innovations International, Inc.accessdata.fda.gov
September 1, 1989K883717BIO-VENTDZESubstantially EquivalentCore-Vent Corp.accessdata.fda.gov
July 10, 1987K871863ADBUTMENT CYLINDER AND SCREWDZESubstantially EquivalentImplant Innovations International, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
August 31, 202086402Class IITerminatedBellaTek Encode Defin3DPMSERitive Abutments-3D Printed Model Reference Numbers: 3DPMSER, 3DPMSERQHex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patientaccessdata.fda.gov
January 10, 202084771Class IITerminatedCERTAIN BELLATEK ENCODE HEALING ABUTMENT 3.4MM(D) X 3.8MM(P) X 3MM(H) Reference Number: IEHA343Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignmentaccessdata.fda.gov
February 26, 201982263Class IITerminatedCERTAIN(R) BELLATEK(R) TIN ABUTMENT 3.4MM, Item Number IEDAN3 - Product Usage: BIOMET3i Restorative products are intended for use as an accessory to endosseous dental implants for placement in the maxilla and mandibleDuring manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.accessdata.fda.gov
May 10, 201880609Class IITerminatedOuter Package Label: Tapered Screw-Vent Implant System, 4.1mm X 10mm, 3.5mm, REF:TSVM4B10, Sterile:R, Rx Only; Inner Package Label: Implant, MTX, 3.7mm x 10mm,3.5mm, REF: TSVB10. Zimmer Dental Implants are designed for uDental implants have incorrect item/lot numbers and size on the inner package labeling. Correct item/lot numbers and size are on the outer package labeling.accessdata.fda.gov
November 29, 201778667Class IITerminatedTapered Screw-Vent MTX, Dental Implant, sterile. Model TSVTB10.Two lots of the Tapered Screw-Vent Implants, with different outer thread diameters, were inadvertently commingled during the manufacturing process and may be mislabeled.accessdata.fda.gov
November 20, 201778635Class IITerminatedTapered Screw-Vent MTX Model TSVTB11Some implant vial caps in the recalled implant lot may inadvertently crack as the result of a manufacturing assembly condition.accessdata.fda.gov
October 11, 201778321Class IITerminatedZimmer Dental GemLock RHD2.5 Hex Driver. The label shows the product is Manufactured by Zimmer Dental Inc., Carlsbad, CA. Endosseous dental implant accessories are manually powered devices intended to aid in the placemenThe device may contain a manufacturing condition affecting the geometry of the driver's hex feature which prevents it from properly engaging the fixture mount transfer and/or a dental implant.accessdata.fda.gov
July 10, 201777911Class IITerminatedGuide Sleeve 3.25 REF 2220, Guide Sleeve 3.75 REF 2221, Guide Sleeve REF 2222, Guide Sleeve REF 2223Zimmer Biomet is conducting a medical device field correction for various dental products due to several parts being shipped to the customer with only standard IFUs. All the products were missing supplemental IFUs.accessdata.fda.gov
March 20, 201776746Class IITerminatedTapered SwissPlus Implant System, Model No. SPB10It was manufactured with the minor diameter of the internal thread that is below specification.accessdata.fda.gov
March 8, 201776809Class IITerminatedBIOMET 3i LTX DENTAL IMPLANTS Model LTX610 (6x10mm) - Plastic tray within Tyvek tray within cardboard box; one (1) unit per box. Labeled Sterile"A single lot of product that potentially has a single part within the lot that does not match the product on the label due to a commingle at the firm supplieraccessdata.fda.gov
September 14, 201675761Class IITerminatedBIOMET 3i CERTAIN LOW PROFILE 17 ABUTMENT 3.4MM(D) X 2MM(H) An endosseous dental implant abutment is a premanufactured prosthetic component directly connected to the endosseous dental implant and is intended for use as aA limited number of product pouches may not have been sealed during packaging.accessdata.fda.gov
August 8, 201674896Class IITerminated3I OSSEOTITE CERTAIN DENTAL IMPLANTS, 4x11.5 mm, Sterile, Rx only.Product was incorrectly packaged.accessdata.fda.gov
January 6, 201673013Class IITerminatedIMPLANT,TM, MTX 4.1 mm x 10 mm diameter 3.5 mm Catalog #TMM4B10 Product Usage: Zimmer Dental implant systems are designed for use in the maxilla or mandible for immediate loading or for loading after a conventional healiInformation specific to the 3.7 mmD and 4.1 mmD Trabecular Metal Zimmer Dental Implants was omitted from the latest revision of the applicable IFU in the Indications, Contraindications, and Precautions sections.accessdata.fda.gov
November 25, 201573184Class IITerminatedCertain EP Healing Abutment 5mm(D) x 5.6mm(P) x 2mm(H) Item: IWTH52 Dental implantsPouches may not have been sealed during packing.accessdata.fda.gov
November 16, 201572658Class IITerminatedRadiographic Transparency for Certain and External Connection Tapered Implants. Images that assist with measurements for dental implants.Images contained within radiographic transparency ART 1036 are undersized.accessdata.fda.gov
September 21, 201572446Class IITerminatedBIOMET 3i, PROVIDE PROTECTION CAP, Catalog # PPC484, PPC485, PPC654, and PPC655 BIOMET 3i Restorative Products are intended for use as an accessory to endosseous dental implants for placement in the maxilla and mandible.Inadequate biocompatibility testing.accessdata.fda.gov
August 10, 201572368Class IITerminatedBiomet 3i Narrow Right Angle Large Driver Tip (Hexed). Driver tips are attached to a surgical drilling unit to carry components such as implant mounts, healing abutments and screws for placement and removal. For dental aThe RASH3N, a hexed, abutment screw driver tip has been labeled and distributed as RASQ3N, a square, abutment screw driver tip. Additionally, the RASQ3N received the RASH3N's laser marking "RASH3N" during manufacturing.accessdata.fda.gov
July 29, 201572000Class IITerminatedUCLA Abutment Hexed Castable Cylinder 3.4mm Are accessories to endosseous dental implant to support a prosthetic device in a partially or completely edentulous patient.MUCC2, non-hexed, castable abutment cylinders, has been labeled and distributed as a MUCC1C, hexed, castable abutment cylinders for this one lot only.accessdata.fda.gov
January 22, 201570304Class IITerminatedGemLock Long Hex Driver, Catalog RHL2.5; Also distributed within the Tapered SwissPlus & SwissPlus Implant Systems Kits, Surgical, Complete, Catalog OPCST; Tapered Screw-Vent Implant System Surgical Kit, Complete, CataloThe Gemlock Long Hex Driver may not fit into the Fixture Mount Transfer (FMT) or the internal hex of the implant.accessdata.fda.gov
November 7, 201470628Class IITerminated3i T3 Non-Platform Switched Tapered Implant Rx Only; 3.25 x 8.5 - 15.0 mm Dental Implants.Endosseous Dental Implants in contact with a residual machine fluid caused the implants to be discolored.accessdata.fda.gov
October 1, 201469392Class IITerminatedSpline Twist Implant, HA 3.25mmD X 15mmL; Part No. 2135. Zimmer Dental Spline implant systems are designed for use in edentulous mandibles or maxillae for attachment of complete denture prostheses for immediate or convenZimmer Dental is recalling Tapered Screw-Vent Implants because the incorrect diameter size was printed on the inner vial.accessdata.fda.gov
June 25, 201468915Class IITerminatedBIOMET 3i Certain Bellatek Encode Healing Abutment Biomet 3i Healing abutments are temporary abutments indicated for use in maintaining the soft tissue opening throughout the healing process prior to dental restoration.Identifiers on the label are correct but the label has the incorrect color coding.accessdata.fda.gov
January 6, 201467207Class IITerminatedTapered Screw-Vent Implant, MTX, 4.7mm x 11.5mm, 4.5mm Platform. Catalog Number TSVWB11, Lot 62470008. Class II, 510(k) K13227.Zimmer Dental is conducting a voluntary recall of a single lot of the Tapered Screw-Vent Implant, Catalog TSVWB11, Lot 62470008, because some of the packages of this lot may have the Cap Label state 3.7 x 10mm instead of 4.7 x 11.5mm.accessdata.fda.gov
October 3, 201367194Class IIITerminatedENDOBON XENOGRAFT GRANULES 0.5 ML (Bovine bone substitute) Endobon is a bone substitute of bovine origin formed from ceramised bone for implantation or transplantation when bone is lost due to trauma or requested during Individual pieces of a batch of Biomet's Endobon Xenograft Granules 0.5 ML (Bovine Bone substitute) may have an incorrect label with the wrong batch number.accessdata.fda.gov
August 29, 201367609Class IITerminatedBIOMET 3i Endosseous Dental Implant.Due to residual machining fluid identified by discoloration (darker in appearance) on the external dental implant surface.accessdata.fda.gov
August 26, 201366787Class IITerminatedDental Abutment labeled in part: "4555 Riverside Drive Palm Beach Gardens, FL 33410 USA ***EDAZ, EDAZx and ILDExxx***BellaTek Zirconia Abutment Position Number: XX Abutment; Pilier; Abutment; Abutment; Pilastro; Pilar***Reports relating to Biomet 3i's BellaTek Zirconia Dental Abutment fractures were received.accessdata.fda.gov
July 22, 201367183Class IITerminatedNavigator Surgical Kit Product Usage: Molded plastic tray used in holding various dental instruments for autoclave processing.During recent revised sterilization validation testing, the included surgical trays did not meet the Sterility Assurance Level required.accessdata.fda.gov
June 10, 201366204Class IITerminatedOsseotite 2 Certain Prevail 5mm(D)X 4.1mm (P) X X 11.5mm (L) Dental Implant Product Usage: Surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in parOne of the dental implants do not have the internal hex feature. One of the dental implants do not have the internal thread feature.accessdata.fda.gov
May 10, 201365005Class IITerminatedBiomet 3i Dental Implant, Parallel Walled 6mm (D) x 10mm (L)A small number of outer implant boxes may be mislabeled. The inner tray, containing the implant, is label correctly. This condition, if present and not recognized could potentially result in the dental implant not being able to be placed into the osteotomy or seated to the desired depth if placement is attempted.accessdata.fda.gov
September 28, 201263618Class IITerminatedProduct is Full OSSEOTITE 2 Tapered Certain Implant, Model Number XIFNT413, and size 4 x 13 mm. The product is sterile. Product provides a means for prosthetic attachment in single tooth restorations and in partially or Biomet 3i recalled Full OSSEOTITE 2 Tapered Certain Implant and Full OSSEOTITE Parallel Walled Certain Implant due to a manufacturing condition where the depth of the implant's internal hex is too shallow. This condition may prevent the driver or abutment from fully engaging in the implant.accessdata.fda.gov
August 3, 201263313Class IITerminatedOsseotite Tapered Certain Implant 5 X 10mm Model INT510 Biomet 3i Dental Implants are intended for surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations anBiomet 3i recalled their Osseotite Tapered Certain Implant, Model # INT510 due to a small percentage of the devices are missing the internal threading.accessdata.fda.gov
May 31, 201262578Class IITerminatedLow Profile Abutment, Non-Hexed Castable Cylinder Model LPCCC1. Product is labeled in part: "***REF LPCCC1***Low profile Abutment Hexed Castable Cylinder***Cylinder; Cylindre; Zylinder; Cilindro; Cilindro; Cilindro***RX Biomet 3i conducted a recall on the device Low Profile Abutment, Non-Hexed Castable Cylinder due to some packages labeled LPCCC1, Hexed Castable Cylinder possibly containing LPCCC2, Non-Hexed Castable Cylinders.accessdata.fda.gov
March 23, 201262375Class IITerminatedREF IFNT611***Full OSSEOTITE Tapered Certain Implant 6 x 11.5mm***Sterile by radiation***Rx Only***BIOMET 3i Dental Iberica S.L. WTC Almeda Park, Ed, 1, Planta 1 Pl. de la Pau s/n08940 Cornella de Llobregat (Barcelona) SBiomet 3i is recalling their product Full Osseotite Tapered Certain Implant IFNT611. The depth of the implant's internal hex is too shallow. The condition, if present, may prevent the driver; cover screw or abutment from fully engaging the implant.accessdata.fda.gov
January 10, 201261473Not yet classifiedTerminatedCertain Low-Profile, Angled Abutment, Model Number ILPAC3217. Product is labeled in part: "***Biomet 3i***4555 Riverside Drive, Palm Beach Gardens, FL 33410 USA***REF ILPAC3217***LOT 2011091179***Certain Low Profile 17 ABiomet 3i initiated a recall for a small percentage of the 33mm (ILPAC3217) abutment packages that may contain the 5mm (ILPAC5217) abutment.accessdata.fda.gov
November 4, 201161376Class IITerminatedImplant, Dental, Endosseous, Acid Etched, ICE, Osseotite, Internal Connection.. Product is labeled in part: "***Certain 3.25, 13***REF IOSM313 LOT*** OSSEOTITE Certain Implant***3.25 x 13mm***CE 0086***Use by yyyy-mm***SOn November 3, 2011 Biomet 3i, Palm Beach Gardens, FL initiated a recall of their Osseotite Certain Implant, Model # IOSM313, Lot #2010111529. Dental implant lot may not have an internal thread.accessdata.fda.gov
September 28, 201160254Not yet classifiedTerminated"***BIOMET 3i***4555 Riverside Drive Palm Beach Gardens FL 33410 USA***REF AC4425***Conical 25 ANGLED ABUTMENT***4.1mm(D) X 4mm(H)***Abutment; Pilier: Abutment; Abutment; Pilastro; Pilar***RX Only***Sterile***BIOMET 3i DOn 09/28/2011 Biomet 3i, Palm Beach Gardens, FL initiated a recall of their Conical Angled Abutment, Model # AC4425 Lot 887628-5 and their Standard Conical Abutment Cylinder Model # SWCA62 Lot 848478. The packaging for the referenced products may not have been completely sealed prior to shipment.accessdata.fda.gov
March 14, 201158921Not yet classifiedTerminatedLPCCC2: Low Profile Abutment Non-Hexed Castable Cylinder by Biomet 3i Castable cylinders are intended to be used to produce a definitive casting for dental restoration onto which porcelain can then be castBiomet 3i, Palm Beach Gardens, FL is recalling the Model LPCCC2 Low Profile Abutment, Non-Hexed Castable Cylinder, Lots 2010101036 and 2010101037 Exp. 10/2015. Package labeling may not correctly describe the package contents. Product was distributed in Europe only.accessdata.fda.gov
March 10, 201158328Not yet classifiedTerminatedREF INT411***OSSEOTITE Tapered Certain Implant 4 x 11.5mm***Sterile Using Radiation***Rx Only***BIOMET 3i Dental lberica S.L.WTC Almeda Park, Ed, 1 Planta 1 Pl. de la Pau s/n08940 Cornella de Llobregat (Barcelona) Spain*Biomet 3i is recalling their product Osseotite NT Certain Dental Implant INT411. The internal thread was not manufactured correctly.accessdata.fda.gov
March 10, 201158326Not yet classifiedTerminatedREF IOSS413*** OSSEIOTITE Certain Implant 4 x 13mm*** Sterile using Radiation*** Rx Only***BIOMET 3i Dental Iberica S.L.WTC Almeda Park, Ed, 1, Planta 1 Pl. de la Pau s/n08940 Cornella de Llobregat (Barcelona) Spain*** BBiomet 3i is recalling their product Osseotite Certain Implant Device IOSS413. The internal thread was not manufactured correctly.accessdata.fda.gov
December 1, 201058769Not yet classifiedTerminated"***3i Incise Custom-Made Label. QP157 Approved 07/09/10*** 3i inc se Custom-made Dental Framework***Biomet 3i 4555 Riverside Drive Palm Beach Gardens, FL 33410 www.biomet3i.com Please consult instructions for use and reOn December 1, 2010 Biomet 3i recalled their product Incise Zirconia Coping (CBZR0102). The Coping contains a manufacturing defect. Coping is oversized. All affected direct accounts were notified by letter on December 14, 2010.accessdata.fda.gov
November 18, 201058766Not yet classifiedTerminatedREF IOSS511***OSSEOTITE Certain Implant 5 x 11.5mm***LOT 910695***Sterile using Radiation***Rx Only***BIOMET 3i Dental Iberica S.L.WTC Almeda Park, Ed, 1, Planta 1 Pl. de la Pau s/n 08940 Cornella de Llobregat (BarcelonaThe product may contain a manufacturing defect, that if present, may prevent the driver; cover screw or abutment from fully engaging the implant.accessdata.fda.gov
February 23, 201058768Not yet classifiedTerminated"***REF IWTH56***Certain EP HEALING ABUTMENT 5mm(D) X 5mm(P) X 6mm(H).*** Healing abutment*** STERILE.***Rx Only.*** Made in USA*** Implant Innovations, Inc. Global Headquarters 4555 Riverside Drive, Palm Beach Gardens, Biomet 3i of Palm Beach Gardens, FL is recalling their Certain EP Healing Abutment (IWTH56). The Healing Abutment dimensions did not match outside label and laser etching on part. The product was actually 8mm but the package indicated 6mm.accessdata.fda.gov
November 23, 200954074Not yet classifiedTerminatedLOCATOR Restorative Abutment, ILOA002, LOT 877423, Certain LOCATOR ABUTMENT, 4.1 mm(D) X 2mm(H), STERILE Made in USA, Sterile. BIOMET 3i 4555 Riverside Drive, Palm Beach Gardens, FL 33410 USA. For use on tissue supportedPackage labeled as sterile may have an incomplete or partial seal thereby possibly compromising sterility.accessdata.fda.gov
October 6, 200954371Not yet classifiedTerminatedBIOMET 3i GS300 GOLD SLOTTED SCREW-3mm, STERILE, Rx Only. Made in USA. Lots 868517, 865348, and 868515. BIOMET 3i, 4555 Riverside Dr., Palm Beach Gardens, FL.Biomet 3i, Palm Beach Gardens, FL is recalling their Gold Slotted Retaining Screw 3MM, Model Number GS300. Product is Out Of Specification - product was manufactured with a material not specified for use in this product.accessdata.fda.gov
June 29, 200952604Not yet classifiedTerminatedACT3020 Advanced Cutting technology (ACT) Twist Drill 3.0mm(D) X 20mm(L). BIOMET 3i 455 Riverside Drive, Palm Beach Gardens, FL 33410 USA. Made in Switzerland. Twist drill for preparation of osteotomy during dental implaSome of the packages of ACT3020, drills may actually contain an ACT3220 drill.accessdata.fda.gov
May 9, 200848677Not yet classifiedTerminatedNavigator System Surgical kit (SGKIT), handles inside of SGKIT Surgical Kit SGDPH1 through SGDPH5. The product is used for CT guided surgery.The drill malfunctions while in use. The drill has been observed to become lodged in the handle.accessdata.fda.gov
February 14, 200847342Not yet classifiedTerminatedBIOMET 3i, EP Healing Abutment, REF/Item Number: THA53, 4.1mm(D) X 5mm(P) X 3mm(H), Sterile, BIOMET 3i, Palm Beach, FLMis-labeling: Labeled THA53 device packaging may contain ITHA53 devices (The ITHA53 is designed to be used with an internally hexed implant--The THA53 is used with an external hex platform)accessdata.fda.gov
February 7, 200847340Not yet classifiedTerminatedBIOMET 3i LOCATOR ABUTMENT, Catalog/Item Number: LOA002, 2.0mm, BioMet 3i, Palm Beach, FL.Mispackaging: The Locator Abutment labeled as LOA002 may contain Catalog/Item # LOA003 product and visa versaaccessdata.fda.gov
February 6, 200847341Not yet classifiedTerminatedBIOMET 3i Certain MicroMiniplant Straight Healing Abutment, Model/Item Number: ISMHA32, 3.4mm(D) X 0mm(P) X 2mm(H), BioMet 3i, Palm Gardens, FL.Seating Problems: The Micro-miniplant Straight Healing Abutments do not fully seat onto the restorative platform of the implant leaving a gap between the abutment and the implant.accessdata.fda.gov
October 8, 200745431Not yet classifiedTerminatedBiomet 3i, Certain PreFormance Temporary Cylinder, Catalog Number: IPFTC42, Dental Implant, Biomet 3i, Palm Beach Gardens, FL 33410Incorrect assembly: The product does not allow for the screw to pass through the access hole and engage the implant properly. Therefore, the provisional restoration will not be seated on the implant platform.accessdata.fda.gov
August 3, 200738983Not yet classifiedTerminatedProduct is labeled as LTX XP Miniplant, Dental Implant, Sterile.The LTX XP Miniplant, BIOMET 3i dental implant, was labeled incorrectly. The 13MM implants were labeled and packaged as 11.5MM implants and 11.5MM implants were labeled and packaged as 13MM implants.accessdata.fda.gov
May 14, 200737994Not yet classifiedTerminatedBiomet 3 i, Disposable Twist Drills, Model Number DT2715.The depth indicator laser line markings on the drills are too faint for clinicians to read during use.accessdata.fda.gov
April 25, 200737865Not yet classifiedTerminatedCertain MicroMiniplant Straight Healing Abutment. Dental implant. Model numbers: ISMHA32, ISMHA33, ISMHA34 and ISMHA36.The Straight Healing Abutment did not fully seat to the restorative platform of the implant, leaving a gap between the abutment and the implant.accessdata.fda.gov
December 11, 200652631Not yet classifiedTerminated3i Custom # 5753, OSCM2913, 2.9MMX 3.4MM X 13MM, OSSEOTITE CUSTOM, MICROMINI IMPLANT, LOT # 470258, Sterile. Implant Innovations, Inc. 4555 Riverside Drive, Palm Beach Gardens, FL 33410. Custom temporary cover screws areHealing Abutment was not made within required manufacturing specification. The product did not have the relief behind the thread, which does not allow proper seating.accessdata.fda.gov
October 16, 200636616Not yet classifiedTerminatedEP Healing abutment- Product Code-ITHA52-a pre-manufactured prosthetic component directly connected to an endosseous dental implant.Package Integrity; sterility compromised-Incomplete seals on the nylon bags in which the product is packed.accessdata.fda.gov
October 4, 200430203Not yet classifiedTerminatedEP Healing Abutment- An abutment device is a premanufactured prosthetic component directly connected to the endosseous dental implant.The nylon bag holding the product was not completely sealed before sterilization. Patients could be infected if the abutment is implanted.accessdata.fda.gov
January 13, 200428217Not yet classifiedTerminatedAdvent Implant LineSterility barrier compromised.accessdata.fda.gov
December 2, 200328092Not yet classifiedTerminatedProducts are various dental surgical drills packed in a sealed tray and labeled as sterile. The tray is labled as follows: 3i Implant Innovations, Inc., 4555 Riverside Drive, Palm Beach 33410 USA DC500 LOT 5.0mm Implant The tray lid seals may be open thereby compromising the sterility barriers for the recalled lots.accessdata.fda.gov
May 9, 200326370Not yet classifiedTerminatedProduct is a drill used in dental surgery labeled in part: OFDR8 OsseoFix Drill 8mm Length 3i Implant Innovations, Inc. 4555 Riverside drive, Palm Beach Gardens, FL 33410 Non Sterile Contents must be sterilized prior to Some 8mm OsseoFix drills included in the kit may be incorrectly laser marked as 4mm OsseoFix drills.accessdata.fda.gov
January 28, 200325722Not yet classifiedTerminatedLTX Endosseous Implant 6.0 mm X 11.5 mm and also LTX Endosseous Implant 5.0 mm X 15 mm, SterileSterile Endosseous implants may be packaged in mislabeled packaging with the incorrect size.accessdata.fda.gov

Compare with other makers

Updated October 23, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.