Data / Medical devices / United States / Zap Surgical Systems Inc.

Zap Surgical Systems Inc.: FDA-registered device maker in San Carlos, CA, United States, 2 510(k) clearances

Zap Surgical Systems Inc. is registered with the FDA (registration 3012039133) in San Carlos, CA, United States. It lists 2 device types. The FDA files 2 510(k) clearances under its listings, the newest dated November 3, 2025. 2 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3012039133
Address
590 Taylor Way, San Carlos, CA, United States, 94070
Owner or operator
Zap Surgical Systems Inc. (10058325)
Roles
Complaint file establishment, Manufacturer
First device listed
July 6, 2023
Registered through
2026
Brand names listed
ZAP-X Radiosurgery System

Devices it lists

DeviceProduct codeClassRoleSource
Accelerator, Linear, MedicalIYE2Complaint file establishment, Manufactureraccessdata.fda.gov
System, Planning, Radiation Therapy TreatmentMUJ2Complaint file establishment, Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
November 3, 2025K250392ZAP-X Radiosurgery System (ZAP-X)IYESubstantially EquivalentZap Surgical Systems, Inc.accessdata.fda.gov
July 29, 2021K211663Zap-X Radiosurgical SystemIYESubstantially EquivalentZap Surgical Systems, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
July 25, 202597413Class IIOngoingZAP-X Radiosurgery System, Model: 300150If the radiosurgery system triggers a proximity error message during a long gantry move (greater-than180 degrees), and a subsequent proximity error message occurs after the automatic reduction of speed, a software defect could potentially lead the collimator to collide with patient shoulders or the patient table.accessdata.fda.gov
July 5, 202290716Class IIOngoingZAP-X Radiosurgery SystemSoftware issue identified in cases of initial patient setup with large (greater-than-or-equal-to 1.5 degrees) rotational deviations, between digitally reconstructed radiographs, and pre-delivery X-ray images. In these cases the transitional alignment algorithm may incorrectly calculate the new treatment table offset values, leading to an incorrect position faccessdata.fda.gov

Compare with other makers

Updated November 3, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.