Data / Medical devices / United States / Wenzel Spine
Wenzel Spine: FDA-registered device maker in Austin, TX, United States, 9 510(k) clearances
Wenzel Spine is registered with the FDA (registration 3006172536) in Austin, TX, United States. It lists 7 device types. The FDA files 9 510(k) clearances under its listings, the newest dated July 9, 2025. 4 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3006172536
- Address
- 2535 Brockton Dr Ste 450, Austin, TX, United States, 78758
- Owner or operator
- Wenzel Spine, Inc. (10030760)
- Roles
- Specification developer
- First device listed
- September 21, 2010
- Registered through
- 2026
- Brand names listed
- PrimaLOK-FF Facet Fixation System, PrimaLOK-SP Interspinous Fusion System, Surgical Planning Software version 1.1, VMA 3, VariLift-A Interbody Fusion System, VariLift-C Interbody Fusion System, VariLift-LX Interbody Fusion System, VariLift-C Interbody Fusion System, panaSIa SI Fusion System
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Appliance, Fixation, Spinal Interlaminal | KWP | 2 | Specification developer | accessdata.fda.gov |
| Intervertebral Fusion Device With Bone Graft, Cervical | ODP | 2 | Specification developer | accessdata.fda.gov |
| Intervertebral Fusion Device With Bone Graft, Lumbar | MAX | 2 | Specification developer | accessdata.fda.gov |
| Sacroiliac Joint Fixation | OUR | 2 | Specification developer | accessdata.fda.gov |
| Spinous Process Plate | PEK | 2 | Specification developer | accessdata.fda.gov |
| System, Facet Screw Spinal Device | MRW | U | Specification developer | accessdata.fda.gov |
| System, Image Processing, Radiological | LLZ | 2 | Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| July 9, 2025 | K250247 | panaSIa SI Fusion System | OUR | Substantially Equivalent | Wenzel Spine, Inc. | accessdata.fda.gov |
| September 27, 2023 | K231076 | VariLift®-C Interbody Fusion System | ODP | Substantially Equivalent | Wenzel Spine, Inc. | accessdata.fda.gov |
| August 15, 2023 | K231807 | primaLOK SP Interspinous Fusion System | PEK | Substantially Equivalent | Wenzel Spine, Inc. | accessdata.fda.gov |
| January 28, 2019 | K180822 | VariLift-LX Interbody Fusion System, VariLift-C Interbody Fusion System | MAX | Substantially Equivalent | Wenzel Spine, Inc. | accessdata.fda.gov |
| November 8, 2017 | K173247 | Surgical Planning Software version 1.1 | LLZ | Substantially Equivalent | Ortho Kinematics, Inc. | accessdata.fda.gov |
| August 25, 2017 | K172327 | VMA System version 3.0 | LLZ | Substantially Equivalent | Ortho Kinematics, Inc. | accessdata.fda.gov |
| September 30, 2010 | K102438 | PRIMALOK FACET FIXATION SYSTEM | MRW | Substantially Equivalent | Osteomed LP | accessdata.fda.gov |
| August 17, 2010 | K100354 | PRIMAL OK INTERSPINOUS FUSION SYSTEM | KWP | Substantially Equivalent | Osteomed LP | accessdata.fda.gov |
| August 5, 2010 | K100820 | WENZEL SPINE VARILIFT INTERBODY FUSION SYSTEM | MAX | Substantially Equivalent | Wenzel Spine | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| May 23, 2018 | 80769 | Class II | Ongoing | Vertebral Motion Analyzer (VMA), 2.3.250. Product System, image processing, radiological | This is to provide notification that, due to a software bug that has been corrected, the Radiological Read Report for the VMA test(s) contained an error. | accessdata.fda.gov |
| March 2, 2017 | 80771 | Class II | Ongoing | Vertebral Motion Analyzer (VMA), 2.3.239 - 2.3.254. Product Usage: VMA software is a quantitative imaging software application intended to be used to process digital image files. | Ortho Kinematics notified customers that errors were contained in Radiological Read Report and VMA Report for the VMA test. The error resulted from an administrative error of VMA user account settings and has been fixed. | accessdata.fda.gov |
| January 11, 2017 | 80680 | Class II | Ongoing | Vertebral Motion Analyzer (VMA) Version 2.3.252. VMA software is a quantitative imaging software application intended to be used to process digital image files. | Ortho Kinematics Inc. sent a Notice of Correction to Released Testing Results, Radiological Read Report for the Vertebral Motion Analyzer (VMA) test because it contained an error. The error occurred due to a software bug that has been corrected. | accessdata.fda.gov |
| August 12, 2016 | 80768 | Class II | Ongoing | Vertebral Motion Analyzer (VMA), VMA DataLink Software.2.3.231, 2.3.232. Product Usage: VMA software is a quantitative imaging software application intended to be used to process digital image files. | Ortho Kinematics, Inc. notified customers of erroneous results of VMA tests due to a software bug that has been corrected. | accessdata.fda.gov |
Compare with other makers
- All makers of Intervertebral Fusion Device With Bone Graft, Cervical
- All makers of Intervertebral Fusion Device With Bone Graft, Lumbar
- All makers of System, Facet Screw Spinal Device
- All makers of Appliance, Fixation, Spinal Interlaminal
- All makers of Spinous Process Plate
- All makers of System, Image Processing, Radiological
Updated July 9, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.