Data / Medical devices / United States / Urologix, LLC
Urologix, LLC: FDA-registered device maker in Plymouth, MN, United States, 1 510(k) clearance and 1 PMA approval
Urologix, LLC is registered with the FDA (registration 2133936) in Plymouth, MN, United States. It lists 3 device types. The FDA files 1 510(k) clearance and 1 PMA approval under its listings, the newest dated November 15, 2012. 5 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 2133936
- FEI number
- 3000718675
- Address
- 13355 10th Ave N. Suite 110, Plymouth, MN, United States, 55441
- Owner or operator
- Urologix LLC (10051240)
- Roles
- Manufacturer, Remanufacturer
- First device listed
- February 22, 2016
- Registered through
- 2026
- Brand names listed
- Coolwave, Electrosurgical, Cutting & Coagulation & Accessories - Prostiva; Electrosurgical, Cutting & Coagulation & Accessories -, Targis
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Electrosurgical, Cutting & Coagulation & Accessories | GEI | 2 | Manufacturer | accessdata.fda.gov |
| System, Hyperthermia, Rf/Microwave (Benign Prostatic Hyperplasia),Thermotherapy | MEQ | 3 | Manufacturer, Remanufacturer | accessdata.fda.gov |
| Unit, Electrosurgical, Endoscopic (With Or Without Accessories) | KNS | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| November 15, 2012 | K113380 | PROSTIVA RF THERAPY HAND PIECE PROSTIVA RF THERAPY RF GENERATOR | GEI | Substantially Equivalent | Medtronic, Inc. | accessdata.fda.gov |
PMA approvals
Premarket approvals this establishment lists, with the supplements the FDA has decided since.
| Approved | PMA number | Device | Product code | Supplements | Latest decision | Source |
|---|---|---|---|---|---|---|
| August 22, 1997 | P970008 | TARGIS (T3) SYSTEM | MEQ | 62 | October 29, 2015 | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| October 21, 2013 | 66598 | Class II | Terminated | Prostiva RF Therapy Hand Piece Kit, REF 8929, Rx only, sterilized using Ethylene Oxide. The Prostiva RF Model 8929 Hand Piece Kit is the delivery system component of the Prostiva RF Therapy System. Prostiva RF Therapy de | A Hand Piece high deployment force exceeded the maximum specification. | accessdata.fda.gov |
| April 28, 2011 | 58695 | Not yet classified | Terminated | The following kits contain the UROLOGIX, Coolant Bag, CA1111B, Sterile EO, Manufactured for: UROLOGIX, Inc., 14405 Twenty-first Avenue North, Minneapolis, MN 55447. UROLOGIX, CTC Advance Short, (2.5-3.5 cm), PT1034, Ster | Urologix is recalling certain lots of Targis System Coolant Bag devices distributed over a two week period. The devices are packaged into disposable Procedure Kits containing a microwave catheter, a Coolant Bag and a RTU Plus balloon. The reason for this Recall involves three lots of Coolant Bags that contain an increased risk of leakage of water at the Sens | accessdata.fda.gov |
| February 18, 2010 | 54703 | Not yet classified | Terminated | UROLOGIX CTC Advance" Standard Microwave Catheter (3.0-5.0 cm), CTC Advance" Long Microwave Catheter (4.5+ cm), CTC Advance" Short Microwave Catheter (2.5 -3.5 cm), RTU Plus Balloon, and RTU Plus Handle, Sterile EO, Manu | Urolgix is recalling certain lots of CTC Advance" catheters and RTU Plus devices which are integral components of the Targis System. The reason for this Recall is a labeling error only; the issue involves a discrepancy in the"Use Before" date printed on the product label. In the affected lots, the "Use Before" date, commonly known as the expiration date, is | accessdata.fda.gov |
| March 16, 2007 | 37638 | Not yet classified | Terminated | Urologix Microwave Delivery System 3.0 - 5.0. For use with prostatic urethra lengths of 3.0-5.0 cm only. Model TA1121D. | The catheter in the kit matches the description on the kit and pouch label; however, an incorrect label was placed onto the catheter during manufacturing. | accessdata.fda.gov |
| December 10, 2003 | 27983 | Not yet classified | Terminated | Prostatron Praktis Type II for Transurethral Microwave Thermotherapy. The Prostatron is a computer-controlled device designed to deliver microwave energy to the prostrate for the treatment of BPH (Benign Prostatic Hyperp | During treatments, using the Prostatron units, the devices' Temperature Sensing System may change the rectal temperature reading by up to 2 degrees Celsius and may briefly delay updates to the rectal temperature reading. | accessdata.fda.gov |
Compare with other makers
- All makers of Unit, Electrosurgical, Endoscopic (With Or Without Accessories)
- All makers of Electrosurgical, Cutting & Coagulation & Accessories
- All makers of System, Hyperthermia, Rf/Microwave (Benign Prostatic Hyperplasia),Thermotherapy
Updated October 29, 2015. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.