Data / Medical devices / United States / Trilliant Surgical LLC

Trilliant Surgical LLC: FDA-registered device maker in Houston, TX, United States, 10 510(k) clearances and 1 PMA approval

Trilliant Surgical LLC is registered with the FDA (registration 3007420745) in Houston, TX, United States. It lists 41 device types. The FDA files 10 510(k) clearances and 1 PMA approval under its listings, the newest dated February 23, 2022. 14 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3007420745
Address
727 N. Shepherd Dr STE 100, Houston, TX, United States, 77007
Owner or operator
Trilliant Surgical (10027494)
Roles
Complaint file establishment, Contract manufacturer, Manufacturer, Repackager or relabeler, Specification developer
First device listed
November 12, 2008
Registered through
2027
Brand names listed
3S Hemi, 3S Hemi Implant, Arsenal, Arsenal Ankle Plating System, Awl, Bender, Broach, Clamp and more

Devices it lists

DeviceProduct codeClassRoleSource
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple ComponentKTT2Contract manufactureraccessdata.fda.gov
AwlHWJ1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
BenderHXW1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Bit, DrillHTW1Complaint file establishment, Contract manufacturer, Specification developeraccessdata.fda.gov
BroachHTQ1Complaint file establishment, Specification developeraccessdata.fda.gov
ClampHXD1Repackager or relabeleraccessdata.fda.gov
CountersinkHWW1Complaint file establishment, Specification developeraccessdata.fda.gov
ElevatorHTE1Complaint file establishment, Specification developeraccessdata.fda.gov
ExtractorHWB1Complaint file establishment, Specification developeraccessdata.fda.gov
Fastener, Fixation, Nondegradable, Soft TissueMBI2Contract manufactureraccessdata.fda.gov
ForcepsHTD1Repackager or relabeleraccessdata.fda.gov
Gauge, DepthHTJ1Complaint file establishment, Specification developeraccessdata.fda.gov
Guide, Surgical, InstrumentFZX1Complaint file establishment, Contract manufacturer, Specification developeraccessdata.fda.gov
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, UncementedOQG2Contract manufactureraccessdata.fda.gov
ImpactorHWA1Complaint file establishment, Specification developeraccessdata.fda.gov
Instrument, Manual, Surgical, General UseMDM1Repackager or relabeleraccessdata.fda.gov
Kit, Surgical Instrument, DisposableKDD1Contract manufactureraccessdata.fda.gov
Nail, Fixation, BoneJDS2Contract manufactureraccessdata.fda.gov
Orthopedic Manual Surgical InstrumentLXH1Complaint file establishment, Contract manufacturer, Specification developeraccessdata.fda.gov
Pin, Fixation, SmoothHTY2Manufactureraccessdata.fda.gov
Plate, Fixation, BoneHRS2Manufactureraccessdata.fda.gov
Prosthesis, Ankle, Uncemented, Non-ConstrainedNTG3Complaint file establishmentaccessdata.fda.gov
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous UncementedLPH2Contract manufactureraccessdata.fda.gov
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/PolymerJWH2Contract manufactureraccessdata.fda.gov
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer CementedKWS2Contract manufactureraccessdata.fda.gov
Prosthesis, Toe, Hemi-, PhalangealKWD2Complaint file establishment, Specification developeraccessdata.fda.gov
Punch, SurgicalLRY1Contract manufactureraccessdata.fda.gov
ReamerHTO1Complaint file establishment, Specification developeraccessdata.fda.gov
RetractorGAD1Repackager or relabeleraccessdata.fda.gov
Rod, Fixation, Intramedullary And AccessoriesHSB2Contract manufactureraccessdata.fda.gov
Screw, Fixation, BoneHWC2Contract manufacturer, Manufactureraccessdata.fda.gov
ScrewdriverHXX1Complaint file establishment, Specification developeraccessdata.fda.gov
Shoulder Prosthesis, Reverse ConfigurationPHX2Contract manufactureraccessdata.fda.gov
Staple, Fixation, BoneJDR2Contract manufactureraccessdata.fda.gov
Suture, Nonabsorbable, Synthetic, PolyethyleneGAT2Contract manufactureraccessdata.fda.gov
TemplateHWT1Complaint file establishment, Specification developeraccessdata.fda.gov
Tray, SurgicalLRP1Complaint file establishment, Specification developeraccessdata.fda.gov
Tray, Surgical, InstrumentFSM1Contract manufactureraccessdata.fda.gov
Washer, Bolt NutHTN2Contract manufacturer, Manufactureraccessdata.fda.gov
Washer, Bolt, Nut, Non-Spinal, MetallicNDG2Manufactureraccessdata.fda.gov
WrenchHXC1Complaint file establishment, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
February 23, 2022K212378Arsenal Ankle Plating SystemHRSSubstantially EquivalentTrilliant Surgicalaccessdata.fda.gov
August 12, 2019K191009Arsenal Plating SystemHRSSubstantially EquivalentTrilliant Surgicalaccessdata.fda.gov
October 26, 2018K181898Two-Step Implant SystemHWCSubstantially EquivalentTrilliant Surgicalaccessdata.fda.gov
November 16, 2017K172178Minimally Invasive Bunion Plating SystemHRSSubstantially EquivalentTrilliant Surgical, Ltd.accessdata.fda.gov
January 14, 2016K153338Tiger Cannulated Screw SystemHWCSubstantially EquivalentTrilliant Surgical, Ltd.accessdata.fda.gov
November 7, 2012K122959HAMMER TOE IMPLANTHWCSubstantially EquivalentTrilliant Surgical, Ltd.accessdata.fda.gov
June 4, 2012K121008TRILLIANT SURGICAL K-WIRESHTYSubstantially EquivalentTrilliant Surgical, Ltd.accessdata.fda.gov
October 20, 2011K112737TIGER HEADLESS CANNULATED SCREWSHWCSubstantially EquivalentTrilliant Surgical, Ltd.accessdata.fda.gov
August 4, 2008K081510TIGER CANNULATED SCREW SYSTEMHWCSubstantially EquivalentTrilliant Surgical, Ltd.accessdata.fda.gov
November 28, 2007K0729223S HEMI TOEKWDSubstantially EquivalentTrilliant Surgical, Ltd.accessdata.fda.gov

PMA approvals

Premarket approvals this establishment lists, with the supplements the FDA has decided since.

ApprovedPMA numberDeviceProduct codeSupplementsLatest decisionSource
May 27, 2009P050050SCANDINAVIAN TOTAL ANKLE REPLACEMENT SYSTEM (S.T.A.R.ANKLE)NTG23March 13, 2024accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
November 4, 201984987Class IITerminated8mm HTR Sterile Hammer Toe Reaming Kit, Material: Stainless Steel, Sterile: R, PX only, UDI: (01)00812926022345(17)231225 (10)TSL007202The firm has identified that parts from the kit, lot: TSL007202, have the potential to contain the incorrect contents of the 8mm HTR Sterile Hammer Toe Reaming Kit. The kit should contain (2) reamers total, (1) Concave Reamer and (1) Convex Reamer; there is the potential that kits from the identified lot may have (2) of the same reamer type as opposed to oneaccessdata.fda.gov
October 10, 201985374Class IITerminated3.5mm Aresenal Screw Drill Bit, Ref: 330-35-001, Qty. 70, Rx Only, Non-Sterile, UDI: (01)00812926029696 - Product Usage: A drill bit facilitates implant insertionLabeling Error; specifically, drill bits from lots # TSL008495A are marked with the lot # of TSL008495. This could lead to parts being misidentified and impact device traceability.accessdata.fda.gov
March 14, 201984350Class IITerminatedGridlock Ankle Screw Driver Bit REF 320-35-003 - Product Usage: A screwdriver facilitates implant insertion and removal.A screwdriver used to facilitate implant insertion and removal was found to be out of specification for the minor diameter of the drive feature causing the driver to be unable to retain screws as intended.accessdata.fda.gov
July 19, 201884977Class IITerminatedInstructions for Use and Surgical Cleaning and Sterilization Protocol for: (1) Trilliant Surgical Tiger Cannulated Screw System, Model 210-00-001; and (2) Combination Tiger/Tiger Headless Cannulated Screw System, Model 2Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.accessdata.fda.gov
March 27, 201880195Class IITerminatedCannulated Driver Handle, Catalog #: 210-00-003, Rx Only, Non SterileFirm is voluntarily recalling cannulated driver handles (210-00-003 and 210-00-004) that may demonstrate a degradation of function with the adapter collar sticking, and/or not retaining the mating adapter male shaft.accessdata.fda.gov
December 8, 201676029Class IITerminatedTiger Screw Sterilization Tray Base Assembly Model 210-00-001 Revision N, O The product is a component of a system indicated for the fixation of fractures, non-unions, arthrodeses, and osteotomies of bones appropriate foFour lots of Tiger Screw Sterilization Tray Base Assemblies were released to the field with a printing error where k-wire description markings indicate diameters of 0.45 and 0.35 instead of 0.045" and 0.035", respectively.accessdata.fda.gov
September 2, 201675187Class IITerminatedModel 208-70-110, Long Thread Tiger Large Cannulated Headless Screw, 7 x 110 mm labeled as "7.0 x 110mm LTTHCS REF 208-70-110 QTY 30 LOT TSL003721 2016-03-29 Trilliant Surgical, LTD"Screws were identified as having the incorrect part number and lot number marked upon them. The part number incorrectly indicated a length of 115 mm rather than 110 mm. The lot number incorrectly indicated lot number of TSL003765 rather than TSL003721.accessdata.fda.gov
August 6, 201571967Class IITerminated7 Hole VL Gridlock Fibula Plate, Part # 300-60-001 NON-STERILE SINGLE USE ONLY; 9 Hole VL Gridlock Fibula Plate, Part # 300-60-002 NON-STERILE SINGLE USE ONLY; 11 Hole VL Gridlock Fibula Plate, Part # 300-60-003 NON-STERThe affected parts subject to the recall are out of specification, resulting in in the loss of the optimal locking screw functionality of the plates. The thread depth of the screw holes is insufficient, potentially limiting the ability to engage and lock with associated mating locking screws.accessdata.fda.gov
July 31, 201571936Class IITerminated2.4, 3.0, and 4.0 mm Gridlock Screw Driver Bit, Model Number 310-30-003, Lot Number TSL002605, NON-STERILE. For use with the Gridlock Plating System for trauma and reconstructive procedures of small bones.Gridlock screw driver bits for the Gridlock Plating System were identified to be out of specification and have the potential for shallow engagement between the driver and the screw, resulting in an increased likelihood of stripping screw heads intraoperatively. Specifically, the minor diameter of the drive feature is above the specification, potentially reduaccessdata.fda.gov
July 20, 201571815Class IITerminatedConcave Reamer Head, 16 mm; Concave Reamer Head, 18 mm; Concave Reamer Head, 20 mm; Concave Reamer Head 22 mm; Convex Reamer Head, 16 mm; Convex Reamer Head, 18 mm; Convex Reamer Head 20 mm; Convex Reamer Head 22 mm, useThe cannulation of the Concave and Convex Reamer Heads may be too small to allow the Guide Pin to freely pass through.accessdata.fda.gov
July 20, 201571813Class IITerminatedTiger Cannulated Tray Lid Part # 210-00-001-1 NON-STERILE; Combined Tiger/Headless Screw Part # 210-99-101 NON-STERILE; These are components of the Tiger Cannulated Screw System and the Tiger Headless Cannulated Screw SySterilization tray lids for the Tiger and Tiger Headless Cannulated Screw Systems were reported to occasionally be difficult to remove from the sterilization tray.accessdata.fda.gov
July 20, 201571812Class IITerminated3.0/4.0 Cannulated Drill Bit; a component of the Tiger Cannulated Screw System The Tiger Cannulated Screw Fixation System implants are intended for fixation of fractures, non-unions, arthrodesis and osteotomies of the smThe cannulation of the 3.0/4.0 Cannulated Drill Bit inner diamter is too small to allow for the guide wire to pass completely through.accessdata.fda.gov
July 20, 201571783Class IITerminated2.0/2.4 Cannulated Screw Countersink Part # 210-24-002 NON-STERILE and 3.0/4.0 Cannulated Screw Countersink Part # 210-40-002 NON-STERILE Product Usage: The Tiger Cannulated Screw Fixation System implants are intended foThe cutting efficiency of the Countersinks was out of specification.accessdata.fda.gov
April 14, 200955180Not yet classifiedTerminated2.0/2.4 Cannulated Screw Driver Bit, part #210-24-003Firm received several complaints of field failures, e.g., "broke during surgery" and the firm initiated a design change. A communication to sales staff 04/14/2009 instructed them to recover and reconcile these products from user physicians.accessdata.fda.gov

Compare with other makers

Updated March 13, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.