Data / Medical devices / France / Tornier S.A.S.
Tornier S.A.S.: FDA-registered device maker in Montbonnot Saint-Martin Isere, France, 43 510(k) clearances
Tornier S.A.S. is registered with the FDA (registration 3000931034) in Montbonnot Saint-Martin Isere, France. It lists 45 device types. The FDA files 43 510(k) clearances under its listings, the newest dated April 3, 2026. 5 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3000931034
- Address
- 161 rue Lavoisier, Montbonnot Saint-Martin Isere, France, 38330
- Owner or operator
- STRYKER CORP. (1811755)
- Roles
- Complaint file establishment, Contract manufacturer, Exporter to the US, Manufacturer, Specification developer
- First device listed
- January 12, 1978
- Registered through
- 2027
- Brand names listed
- 10.5MM FLEXIBLE REAMER, 10MM FLEXIBLE REAMER, 10mm SUBFIX TRIAL, 11.5MM FLEXIBLE REAMER, 11.5mm SUBFIX TRIAL, 11MM FLEXIBLE REAMER, 12MM FLEXIBLE REAMER, 135 mm Reusable Slat, SE Retr, 10 Pack and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Awl | HWJ | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Bit, Drill | HTW | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Bit, Surgical | GFG | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Blade, Saw, General & Plastic Surgery, Surgical | GFA | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Broach | HTQ | 1 | Contract manufacturer | accessdata.fda.gov |
| Cement Obturator | LZN | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Clamp | HXD | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Curette | HTF | 1 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Elevator | HTE | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Extractor | HWB | 1 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
| Forceps | HTD | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Gauge, Depth | HTJ | 1 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
| Guide, Surgical, Instrument | FZX | 1 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
| Hammer, Surgical | FZY | 1 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Impactor | HWA | 1 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
| Instrument, Compression | HWN | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Instrument, Surgical, Orthopedic, Ac-Powered Motor And Accessory/Attachment | HWE | 1 | Manufacturer | accessdata.fda.gov |
| Mesh, Surgical | FTM | 2 | Manufacturer | accessdata.fda.gov |
| Mixer, Cement, For Clinical Use | JDZ | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Orthopedic Manual Surgical Instrument | LXH | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Passer | HWQ | 1 | Contract manufacturer | accessdata.fda.gov |
| Prosthesis, Elbow, Constrained, Cemented | JDC | 2 | Contract manufacturer | accessdata.fda.gov |
| Prosthesis, Elbow, Hemi-, Radial, Polymer | KWI | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Prosthesis, Elbow, Semi-Constrained, Cemented | JDB | 2 | Complaint file establishment, Contract manufacturer, Manufacturer | accessdata.fda.gov |
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | JDI | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented | HSD | 2 | Complaint file establishment, Contract manufacturer, Manufacturer, Specification developer | accessdata.fda.gov |
| Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented | KWT | 2 | Complaint file establishment, Contract manufacturer, Manufacturer, Specification developer | accessdata.fda.gov |
| Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented | PAO | 2 | Contract manufacturer | accessdata.fda.gov |
| Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented | KWS | 2 | Complaint file establishment, Contract manufacturer, Exporter to the US, Manufacturer, Specification developer | accessdata.fda.gov |
| Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained | PKC | 2 | Contract manufacturer, Manufacturer | accessdata.fda.gov |
| Prosthesis, Wrist, Carpal Trapezium | KYI | 2 | Exporter to the US, Manufacturer | accessdata.fda.gov |
| Punch, Surgical | LRY | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Pusher, Socket | HXO | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Rasp | HTR | 1 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
| Reamer | HTO | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Retractor | GAD | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Saw, Manual And Accessories | GDR | 1 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Screwdriver | HXX | 1 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
| Shoulder Arthroplasty Implantation System | QHE | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Shoulder Joint Humeral (Hemi-Shoulder) Ceramic Head/Metallic Stem Cemented Or Uncemented Prosthesis | QKW | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Shoulder Prosthesis, Reverse Configuration | PHX | 2 | Complaint file establishment, Contract manufacturer, Exporter to the US, Manufacturer, Specification developer | accessdata.fda.gov |
| Tap, Bone | HWX | 1 | Manufacturer | accessdata.fda.gov |
| Template | HWT | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Tray, Surgical, Instrument | FSM | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Wrench | HXC | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| April 3, 2026 | K253674 | Blueprint Patient-Specific Instrumentation | PHX | Substantially Equivalent | Stryker Corporation (Tornier, S.A.S.) | accessdata.fda.gov |
| January 8, 2026 | K252788 | Tornier Perform Reversed Monopost Glenoid (Perform Mono) | PHX | Substantially Equivalent | Tornier, Inc. | accessdata.fda.gov |
| October 10, 2024 | K241491 | Blueprint Patient-Specific Instrumentation; Shoulder iD Primary Reversed Glenoid | PHX | Substantially Equivalent | Stryker Corporation (Tornier, S.A.S.) | accessdata.fda.gov |
| February 21, 2024 | K232265 | BLUEPRINT Patient Specific Instrumentation | PHX | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| December 16, 2022 | DEN220012 | Tornier Pyrocarbon Humeral Head | QKW | Unknown | Tornier S.A.S. | accessdata.fda.gov |
| November 12, 2021 | K211359 | Tornier Perform Patient-Matched Primary Reversed Glenoid and BLUEPRINT Patient Specific Instrumentation | PHX | Substantially Equivalent | Tornier, Inc. | accessdata.fda.gov |
| June 12, 2019 | K190521 | Aequalis Ascend Flex Shoulder System | KWS | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| February 22, 2017 | K162800 | BLUEPRINT Patient Specific Instrumentation | KWS | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| December 27, 2016 | K161789 | BLUEPRINT Patient Specific Instrumentation | KWS | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| November 15, 2016 | K161742 | Aequalis PerFORM Reversed, Aequalis PerFORM+ Reversed Glenoid | PHX | Substantially Equivalent | Tornier, Inc. | accessdata.fda.gov |
| June 10, 2016 | K160555 | BLUEPRINT Patient Specific Instrumentation | KWS | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| September 24, 2015 | K151293 | Aequalis Ascend Flex Shoulder System, Aequalis Reversed Shoulder Prosthesis | KWS | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| April 8, 2015 | K143374 | BLUEPRINT Patient Specific Instrumentation | KWS | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| March 4, 2015 | K143552 | Simpliciti Shoulder System | PKC | Substantially Equivalent | Tornier, Inc. | accessdata.fda.gov |
| August 6, 2014 | K140478 | AEQUALIS REVERSED SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| July 18, 2014 | K140082 | AEQUALIS(TM) ASCENT(TM) FLEX SHOULDER SYSTEM | PHX | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| December 5, 2013 | K132285 | AEQUALIS REVERSED SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| October 16, 2013 | K131231 | AEQUALIS SHOULDER FRACTURE SYSTEM, AEQUALIS REVERSED SHOULDER PROSTHESIS, AEQUALIS REVERSED FRACTURE SHOULDER PROTHESIS | PHX | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| January 8, 2013 | K122698 | AEQUALIS ASCEND FLEX SHOULDER SYSTEM | KWS | Substantially Equivalent | Tornier S.A.S. | accessdata.fda.gov |
| March 13, 2012 | K112144 | AEQUALIS SHOULDER FRACTURE SYSTEM, AEQUALIS REVERSED SHOULDER PROSTHESIS, AEQUALIS REVERSED FRACTURE SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| November 3, 2011 | K111902 | AEQUALIS SHOULDER SYSTEM | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| May 6, 2010 | K100142 | AEQUALIS REVERSED SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| October 24, 2008 | K082120 | AEQUALIS REVERSED FRACTURE SHOULDER PROTHESIS | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| July 17, 2008 | K081059 | AEQUALIS REVERSED SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| October 18, 2007 | K071948 | AEQUALIS REVERSED ADAPTER | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| September 14, 2006 | K061824 | TORNIER CEMENT RESTRICTOR | LZN | Substantially Equivalent | Tornier | accessdata.fda.gov |
| July 20, 2006 | K061439 | AEQUALIS REVERSED PROSTHESIS | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| May 10, 2006 | K060386 | NEXA CARPO METACARPAL IMPLANT | KYI | Substantially Equivalent | Nexa Orthopedics, Inc. | accessdata.fda.gov |
| April 18, 2006 | K060438 | RHS | JDB | Substantially Equivalent | Tornier | accessdata.fda.gov |
| March 2, 2006 | K060209 | AEQUALIS SHOULDER FRACTURE SYSTEM & AEQUALIS SHOULDER SYSTEM | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| March 16, 2005 | K050316 | AEQUALIS REVERSED SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| August 25, 2004 | K041873 | AEQUALIS REVERSED SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| June 17, 2004 | K041339 | AEQUALIS SHOULDER SYSTEM | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| May 14, 2004 | K030941 | AEQUALIS REVERSED SHOULDER PROSTHESIS | PHX | Substantially Equivalent | Tornier | accessdata.fda.gov |
| August 15, 2001 | K012212 | MODIFICATION TO AEQUALIS SHOULDER SYSTEM | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| July 13, 2001 | K011942 | AEQUALIS PRESS-FIT SHOULDER PROSTHESIS | HSD | Substantially Equivalent | Tornier | accessdata.fda.gov |
| August 31, 2000 | K994041 | TORNIER BIPOLAR RADIAL HEAD PROSTHESIS | KWI | Substantially Equivalent | Tornier, Inc. | accessdata.fda.gov |
| July 20, 2000 | K001932 | TORNIER CEMENT RESTRICTOR | JDI | Substantially Equivalent | Tornier | accessdata.fda.gov |
| June 22, 2000 | K994393 | AEQUALIS UNIVERSAL SHOULDER GLENOID | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| March 10, 2000 | K994392 | AEQUALIS SHOULDER FRACTURE SYSTEM | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| August 23, 1999 | K980244 | AEQUALIS SHOULDER PROSTHESIS | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
| December 9, 1997 | K973453 | TORNIER CEMENT RESTRICTOR | JDI | Substantially Equivalent | Tornier | accessdata.fda.gov |
| September 27, 1995 | K952928 | AEQUALIS SHOULDER SYSTEM FOR TOTAL & HEMISHOULDER APPLICATIONS | KWS | Substantially Equivalent | Tornier | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| April 10, 2025 | 96651 | Class II | Ongoing | Blueprint Software, BPUE001. Intended for use by surgeons as a pre surgical planner for shoulder replacement. | A software bug in Blueprint version 4.2.1 prevents users from accessing cases initiated in previous versions of the software. | accessdata.fda.gov |
| March 5, 2025 | 96437 | Class II | Ongoing | stryker Blueprint Mixed Reality BP MxR Glenoid Pin Guide PPSU + Stainless Steel, Catalog Number MRUE200, packaged in stryker Blueprint Mixed Reality Instrument Kit, Catalog Number MRUEGLN; Total Shoulder Arthroplasty | Stryker identified an elevated complaint rate related to difficulties using the Blueprint Mixed Reality Guidance Instrumentation system is multifactorial, but in each instance prohibits the system from meeting its intended use. The most commonly reported complaints were related to impaired software functioning, impaired instrumentation functioning, and gener | accessdata.fda.gov |
| December 18, 2024 | 96030 | Class II | Ongoing | Stryker Blueprint Mixed Reality BP MxR Glenoid Pin Guide, REF MRUE200. Indicated for use during Total Shoulder Arthroplasty. | The Pin Guide is being recalled because the metal tube may disassemble from the plastic handle. This can result in the Blueprint Mixed Reality headset being unable to detect the Pin Guide and potentially prolonging surgery time or changing of surgical method from guided to conventional. | accessdata.fda.gov |
| April 16, 2024 | 94444 | Class II | Ongoing | Stryker Blueprint Software, Catalog #BPUE001. | The software bug allows for case planning with anatomic glenoid Perform / Perform Augmented implants and anatomic humeral Tornier Flex implant configurations that are incompatible and do not have regulatory approval. | accessdata.fda.gov |
| June 25, 2021 | 88174 | Class II | Ongoing | The Aequalis Pyrocarbon Humeral Heads. Shoulder implant component. Sold OUS only: a) Catalog # DWH039 - Diameter 39 mm Height 14 mm Eccentric LOW (1.5) Material PyC/CoCr, b) Catalog # DWH041 - Diameter 41 m m Height 15 m | Potential patient exposure to the graphite substrate. | accessdata.fda.gov |
Compare with other makers
- All makers of Orthopedic Manual Surgical Instrument
- All makers of Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
- All makers of Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
- All makers of Screwdriver
- All makers of Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
- All makers of Cement Obturator
Updated April 3, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.