Skip to the page

Data / Medical devices / United States / The Ruhof Corporation

The Ruhof Corporation: FDA-registered device maker in Mineola, NY, United States, 7 510(k) clearances

The Ruhof Corporation is registered with the FDA (registration 3003207991) in Mineola, NY, United States. It lists 14 device types. The FDA files 7 510(k) clearances under its listings, the newest dated October 16, 2023. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3003207991
Address
393 Sagamore Ave, Mineola, NY, United States, 11501
Owner or operator
The Ruhof Corporation (10038187)
Roles
Complaint file establishment, Manufacturer, Repackager or relabeler, Specification developer
First device listed
September 22, 2011
Registered through
2026
Brand names listed
345CKENT Custom Kit, 345CVTK, 345EBK500 345EBKNA500 G4SVECOLRF 345EBK, 345PTC100, 345SVECOS, 345SVV04, 345SVVO4, 345SVVO5 and more

Devices it lists

DeviceProduct codeClassRoleSource
Accessories, Cleaning Brushes, For EndoscopeMNL1Complaint file establishment, Manufacturer, Repackager or relabeleraccessdata.fda.gov
Adaptor, Bulbs, Miscellaneous, For EndoscopeFFY1Complaint file establishmentaccessdata.fda.gov
Applicator, Absorbent Tipped, SterileKXG1Complaint file establishmentaccessdata.fda.gov
Cannula, Nasal, OxygenCAT1Complaint file establishmentaccessdata.fda.gov
Cleaner, Ultrasonic, Medical InstrumentFLG1Manufactureraccessdata.fda.gov
Container, Specimen Mailer And Storage, SterileKDT1Complaint file establishmentaccessdata.fda.gov
Culture Media, Non-Propagating TransportJSM1Complaint file establishmentaccessdata.fda.gov
Endoscope Channel AccessoryODC2Complaint file establishment, Manufactureraccessdata.fda.gov
Endoscopic Irrigation/Suction SystemOCX2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Gauze / Sponge,Nonresorbable For External UseNAB1Repackager or relabeleraccessdata.fda.gov
General Purpose ReagentPPM1Complaint file establishmentaccessdata.fda.gov
Lubricant, PatientKMJ1Complaint file establishmentaccessdata.fda.gov
Syringe, Irrigating (Non Dental)KYZ1Repackager or relabeleraccessdata.fda.gov
Transport Medium, Notified Per The Vtm GuidanceQMC1Complaint file establishmentaccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
October 16, 2023K232118ANDORATE® Valve KitODCSubstantially EquivalentGa Health Company Limitedaccessdata.fda.gov
August 18, 2022K212856iClean Viral Transport System (VTM-RT kit)JSMSubstantially EquivalentHuachenyang (Shenzhen) Technology Co. , Ltd.accessdata.fda.gov
April 17, 2019K182998Andorate Auxiliary Water ConnectorOCXSubstantially EquivalentSmartdata Suzhou Co., Ltd.accessdata.fda.gov
July 6, 2018K181509Endorate Valve SetsOCXSubstantially EquivalentSmartdata Suzhou Co., Ltd.accessdata.fda.gov
December 3, 2015K151714Disposable Endoscope Valves Set AODCSubstantially EquivalentWilson Instruments (Shanghai) Company Limitedaccessdata.fda.gov
May 17, 2013K122417SCOPEVALET DISPOSABLE BIOPSY VALVEOCXSubstantially EquivalentThe Ruhof Corp.accessdata.fda.gov
April 10, 2012K112110STERILE LUBRICATING JELLYKMJSubstantially EquivalentJianerkang Medical Dressing Companyaccessdata.fda.gov

Compare with other makers

Updated October 16, 2023. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.