Data / Medical devices / United States / Tacmed Solutions, LLC
Tacmed Solutions, LLC: FDA-registered device maker in Anderson, SC, United States, 2 510(k) clearances
Tacmed Solutions, LLC is registered with the FDA (registration 3005853033) in Anderson, SC, United States. It lists 12 device types. The FDA files 2 510(k) clearances under its listings, the newest dated May 13, 2011. 1 recall event names it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3005853033
- Address
- 1250 Harris Bridge Rd, Anderson, SC, United States, 29621
- Owner or operator
- TACMED SOLUTIONS, LLC (9090046)
- Roles
- Manufacturer, Repackager or relabeler, Specification developer
- First device listed
- July 21, 2006
- Registered through
- 2026
- Brand names listed
- BLAST BANDAGE, Compact Trauma Bandage (CTB/TR011), Control Wrap, ESMARK, Foxtrot Litter, HEL-BLKT - Helios Blanket, HELIOS-K - Helios System, HELIOS-KW - Helios System with Warming and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Bandage, Elastic | FQM | 1 | Repackager or relabeler | accessdata.fda.gov |
| Cricothyrotomy Kit | OGP | 2 | Specification developer | accessdata.fda.gov |
| Device, Fixation, Tracheal Tube | CBH | 1 | Specification developer | accessdata.fda.gov |
| Dressing, Compression | MHW | 1 | Specification developer | accessdata.fda.gov |
| Hemostatic Wound Dressing Without Thrombin Or Other Biologics | QSY | U | Specification developer | accessdata.fda.gov |
| Needle, Aspiration And Injection, Disposable | GAA | 1 | Repackager or relabeler | accessdata.fda.gov |
| Pack, Hot Or Cold, Disposable | IMD | 1 | Specification developer | accessdata.fda.gov |
| Retractor | GAD | 1 | Specification developer | accessdata.fda.gov |
| Scalpel, One-Piece | GDX | 1 | Specification developer | accessdata.fda.gov |
| Stretcher, Hand-Carried | FPP | 1 | Specification developer | accessdata.fda.gov |
| Syringe, Piston | FMF | 2 | Repackager or relabeler | accessdata.fda.gov |
| Tourniquet, Nonpneumatic | GAX | 1 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 13, 2011 | K110771 | BD SINGLE USE, HYPODERMIC SYRINGE | FMF | Substantially Equivalent | Becton, Dickinson and Company | accessdata.fda.gov |
| August 25, 2009 | K092357 | CHITOGAUZE,2 IN X 2 IN,8 PLY, 4 IN X 4 IN 8 PLY, 4 IN X 8 IN, 8PLY, 1 IN X 4 IN, 8PLY, CHITOGAUZE, PACKAGING STRIP, 1/2 | QSY | Substantially Equivalent | Hem Con Medical Technologies, Inc. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| April 17, 2018 | 80157 | Class II | Terminated | BLAST Bandage, sterile. | Blast Bandages (part# BLAST) with Lot# 0617 were not terminally sterilized. | accessdata.fda.gov |
Compare with other makers
- All makers of Stretcher, Hand-Carried
- All makers of Hemostatic Wound Dressing Without Thrombin Or Other Biologics
- All makers of Scalpel, One-Piece
- All makers of Bandage, Elastic
- All makers of Syringe, Piston
- All makers of Cricothyrotomy Kit
Updated May 13, 2011. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.