Skip to the page

Data / Medical devices / United States / Summit Industries, LLC

Summit Industries, LLC: FDA-registered device maker in Niles, IL, United States, 3 510(k) clearances

Summit Industries, LLC is registered with the FDA (registration 1450503) in Niles, IL, United States. It lists 8 device types. The FDA files 3 510(k) clearances under its listings, the newest dated February 9, 2018. 2 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1450503
Address
7555 N. Caldwell Avenue, Niles, IL, United States, 60714
Owner or operator
SUMMIT INDUSTRIES, LLC (1450503)
Roles
Complaint file establishment, Manufacturer
First device listed
July 18, 2001
Registered through
2026
Brand names listed
00210, 03900, 03901, A-172F, C256, D800, DFMT System, FMT System and more

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
February 9, 2018K173823Amrad Medical AAU Digital Radiography System; Amrad Medical AAU Plus Digital Radiography System; Amrad Medical DFMT Digital Radiography System; Amrad Medical FMT Digital Radiography SystemKPRSubstantially EquivalentSummit Industries, LLCaccessdata.fda.gov
March 14, 2016K153119Amrad Medical OTS Digital Radiography System, Amrad Medical DFMTS Digital Radiography SystemAmrad Medical FRS Digital Radiography System,KPRSubstantially EquivalentSummit Industries, LLCaccessdata.fda.gov
December 30, 1987K874687COLLI-MATETM MODEL NO. B800IZXSubstantially EquivalentSummit Industries, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
October 28, 201469631Class IITerminatedThe J700 Floor Mounted Tube Stand (FMTS) is intended to support and position the diagnostic x-ray tube housing assembly for a medical radiographic procedure. The product consists of a vertical column (with counterbalanceThe welds on J700 tube stands may be insufficient resulting in tube stand breakage, damage to the X-Ray machine, and/or patient or healthcare provider injury.accessdata.fda.gov
August 10, 200738512Not yet classifiedTerminatedLX125 Swivel Collimator, Model D800; Manual Radiographic Collimator; Summit Industries, Inc., Chicago, IllinoisThe D800 Swivel Collimator may come loose from the tubestand and fall onto the x-ray table.accessdata.fda.gov

Compare with other makers

Updated February 9, 2018. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.