Steris Corporation: FDA-registered device maker in Mentor, OH, United States, 41 510(k) clearances

Steris Corporation is registered with the FDA (registration 1527821) in Mentor, OH, United States. It lists 4 device types. The FDA files 41 510(k) clearances under its listings, the newest dated April 8, 2026. 84 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1527821
Address
5960 Heisley Road, Mentor, OH, United States, 44060
Owner or operator
STERIS Corporation (10078069)
Roles
Specification developer
First device listed
October 13, 2020
Registered through
2027
Brand names listed
AMSCO V-PRO 1 Low Temperature Sterilization System (MY-CFE), AMSCO V-PRO 1 PLUS Low Temperature Sterilization System (MY-CFE), AMSCO V-PRO 1 Plus Low Temperature Sterilization System (MY-CFE), AMSCO V-PRO maX Low Temperature Sterilization System (MY-CFE), Amsco V-PRO 1 Low Temperature Sterilization System (MY-CFE), Amsco V-PRO 1 Low Temperature Sterilization Systems (MY-CFE), Amsco V-PRO 1 Plus Low Temperature Sterilization System (MY-CFE), Minncare HD and more

Devices it lists

DeviceProduct codeClassRoleSource
Accessories, Cleaning, For EndoscopeFEB2Specification developeraccessdata.fda.gov
Disinfectant, Subsystem, Water PurificationNIH2Specification developeraccessdata.fda.gov
Sterilant, Medical DevicesMED2Specification developeraccessdata.fda.gov
Sterilizer, ChemicalMLR2Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
April 8, 2026K251666SYSTEM 1E Liquid Chemical Sterilant Processing System, Model P6700; SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900MEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
December 2, 2024K243433enspire 3000 Cleaning and Liquid Chemical Sterilant Processing SystemFEBSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
October 20, 2023K233065V-PRO maX 2 Low Temperature Sterilization SystemMLRSubstantially EquivalentSterisaccessdata.fda.gov
October 3, 2023K232914SYSTEM 1E Liquid Chemical Sterilant Processing System (P6500); SYSTEM 1 endo Liquid Chemical Sterilant Processing System (P6800); SYSTEM 1 endo Liquid Chemical Sterilant Processing System (P6900)MEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
June 30, 2023K230930enspire 3000 Cleaning and Liquid Chemical Sterile Processing SystemFEBSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
March 28, 2023K230582SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900MEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
September 28, 2022K222615SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6800, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900, S40 Sterilant ConcentrateMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
September 9, 2022K222093V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization SystemMLRSubstantially EquivalentSterisaccessdata.fda.gov
September 7, 2021K211607SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6800, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900, S40 Sterilant ConcentrateMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
May 12, 2021K210737SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6800, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900, S40 Sterilant ConcentrateMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
December 10, 2019K192929SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6800, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900MEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
September 5, 2019K191343SYSTEM 1 endo Liquid Chemical Sterilant Processing System,Model P6900MEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
May 9, 2019K190917V-PRO 60 a Low Tempurature Strilization Systems, V-PRO s2 Low Temperature Sterilization SystemsMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
April 5, 2019K190103V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization System, V-PRO 1 Plus Low Temperature Sterilization System, V-PRO 1 Low Temperature Sterilization SystemMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
March 22, 2019K190104SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 Endo Liquid Chemical Sterilant Processing SystemMEDSubstantially EquivalentSteris Corporationsaccessdata.fda.gov
January 31, 2019K182827SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model 6900MEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
January 3, 2019K182568V-PRO s2 Low Temperature Sterilization System, V-PRO 60 Low Temperature Sterilization SystemMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
April 4, 2018K180342SYSTEM 1E Liquid Chemical Sterilant Processing SystemMEDSubstantially EquivalentSteris Corporationsaccessdata.fda.gov
March 2, 2018K173256System 1 endo Liquid Chemical Sterilant Processing SystemMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
February 9, 2018K172754V-PRO maX 2 Low Temperature Sterilization SystemMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
January 18, 2018K172319AMSCO V-PRO 1 Low Temperature Sterilization System, AMSCO V-PRO 1 Plus Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization System, V-PRO 60 Low Temperature Sterilization SystemMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
September 22, 2017K170956SYSTEM 1E Liquid Chemical Sterilant Processing SystemMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
March 31, 2017K162413AMSCO V-PRO 1 Low Temperature Sterilization System, AMSCO V-PRO 1 Plus Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization System, V-PRO 60 Low Temperature Sterilization SystemMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
August 5, 2016K161683SYSTEM 1E Liquid Chemical Sterilant Processing SystemMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
July 6, 2016K160433V-PRO® 1 Plus and V-PRO® maX Low TemperatureMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
August 27, 2014K133724MINNCARE HDNIHSubstantially EquivalentMedivators, Inc.accessdata.fda.gov
July 24, 2014K140498V-PRO 60 LOW TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
July 16, 2013K131120AMSCO V-PRO 1 LOW, V-PRO 1 PLUS, V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
July 5, 2013K131078SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEMMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
June 26, 2012K120632AMSCO V-PRO 1 LOW/PLUS/MAX TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
February 21, 2012K113520SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEMMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
December 1, 2011K112813AMSCO V-PROMLRSubstantially EquivalentSteris Corpaccessdata.fda.gov
November 22, 2011K112760AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
September 2, 2011K111810AMSCO V-PRO 1 AND V-PRO 1 PLUS LOW TEMPERATURE STERILIZATION UNITSMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
August 18, 2011K102394AMSCO V-PRO 1 LOW TEMPERATURE STERILIZATION SYSTEM; AMSCO V-PRO 1 PLUS LOW TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
August 12, 2011K102330AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
September 21, 2010K102462SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEMMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
August 2, 2010K101409SYSTEM IE LIQUID CHEMICAL CTERILANT PROCESSING SYSTEMMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
April 5, 2010K090036SYSTEM 1.5 STERILE PROCESSING SYSTEMMEDSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
August 3, 2009K083097AMSCO V-PRO 1 LOW TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov
October 4, 2007K062297VHP 136 LOW TEMPERATURE STERILIZATION SYSTEMMLRSubstantially EquivalentSTERIS Corporationaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
September 23, 202699856Class IIOngoingHexaVue Focus Integration System, a single, all-in-one system that handles operating room video routing, surgical video integration, and environmental control, Software Version: 2.0.18A software issue may result in unintended mismatch of patient information on manually printed images. Incorrect patient information appearing on printed images could create a documentation discrepancy or incorrect association of clinical images with a patient record.accessdata.fda.gov
September 21, 202699804Class IIOngoingRAPICIDE PA Part A High-Level Disinfectant, Model/Catalog Number: ML020115If the vented cap becomes blocked, gas may accumulate and the bottle may swell due to increased internal pressure. In some cases, excess vapor or liquid chemistry may escape from the bottle when the cap is twisted during opening, which could result in user exposure if required personal protective equipment (PPE) is not properly used. Such exposure may resultaccessdata.fda.gov
August 31, 202699704Class IIOngoingVERIFY Biological/Integrator Challenge Pack Model/Catalog Number: LCB006Geobacillus stearothermophilus spore population in affected products may fall below minimum shelf life specification. When used to monitor steam sterilization cycles, the potential hazard is that the biological indicator will show no growth, indicating that the steam cycle was effective, even if the steam cycle did not achieve the intended spore reductionaccessdata.fda.gov
May 15, 202698768Class IIOngoingHarmonyAIR A-Series Surgical Lighting SystemThe the plus and minus buttons (+/-) used to control light intensity on the light heads may detach.accessdata.fda.gov
May 15, 202698767Class IIOngoingHarmonyAIR A-Series Surgical Lighting SystemThere is a potential for paint delamination (chipping/peeling) on the lighting system's light heads.accessdata.fda.gov
November 19, 202597986Class IIOngoingAMSCO 7052HP Washer/Disinfector Model/Catalog Number: 7052HP Product Description: The AMSCO 7052HP Washer/Disinfector is intended for use in the cleaning and intermediate-level disinfection of soiled reusable simple hardWire connected to the electrical box may shift out of its intended position, which may result in electrical arcing. Electrical arcing remains internal within the unit (no risk of shock to users).accessdata.fda.gov
June 23, 202597068Class IIOngoingDual Flat Panel Monitor (DFPM) accessories for HarmonyAIR A-Series Surgical Lighting SystemsThe DFPM yoke assembly ("yoke assembly") may detach from the spring arm. Should the yoke assembly detach from the spring arm, the yoke assembly would not be expected to fully detach but rather hang from the wiring within the yoke assembly.accessdata.fda.gov
May 23, 202598266Class IIOngoingBarco MNA with the HexaVue IP Integration System, Model/Catalog Number: MNA-6x0-HThis is a sub-recall of event RES 96885. The supplier identified that during their manufacturing process for a limited batch of MNA-6x0 (adapter) components the incorrect configuration file was used.accessdata.fda.gov
June 13, 202494987Class IIOngoingHookup Model/Catalog Number: 2-8-540 Product Description: Hookups provide the interface between an Advantage Plus" Automated Endoscope Reprocessor and Advantage Plus" Pass-Thru Automated Endoscope Reprocessor ( AER ) andIFU for hookup were incorrectly reflected within hookup IFUs and online reference system, Hookup Lookup (HULU). Use of an incorrect hookup connection and/or parameter set may prevent an endoscope from being properly disinfected, which may present a risk of patient contamination or infectionaccessdata.fda.gov
December 12, 202393733Class IIOngoingDual Articulating Headrest, Pad Ret P/N P141210805, REF BF754Dual-articulating head rest may not stay in place or may fail to lock into position during a patient procedure which could result in an injury to the patient or a procedural delay.accessdata.fda.gov
November 16, 202393610Class IIOngoingV. Mueller Universal Bandage Scissors Black Plastic Handles Heavy-Duty, Autoclavable, Overall Length 7 (18 cm)- Intended to cut through tape and bandages Model: SU2014-001Bandage Scissors handle cover component contains an incorrect color masterbatch resin carrier. This may allow a pink dye/residue to appear on the Bandage Scissors and/or sterilization pouches after processing.accessdata.fda.gov
November 13, 202393566Class IIOngoingHookup Accessories used with MEDIVATORS ADVANTAGE PLUS and ADVANTAGE PLUS Pass Thru Automated Endoscope Reprocessors Model # Model Description 2-8-001 HU ZERO CHANNEL NO LT 2-8-010 ASSY, HOOK-UP, OLYMPUS 2-8-014 HOOKUP, Identification label on affected hookups could become illegible over time due to the label's ink coming off. This may potentially prevent users from being able to effectively identify the hookup and may ultimately result in postponement of patient procedures.accessdata.fda.gov
April 10, 202392044Class IIOngoingReliance Vision Multi-Chamber Washer/Disinfector, Reference Number FH83062In the remote occurrence in which the electrical contactor component present in the drying chambers of the Reliance Vision Multi-Chamber Washer/Disinfector malfunctions, the heating elements in the drying chamber could overheat, eventually resulting in smoke and/or fire.accessdata.fda.gov
March 17, 202392040Class IIOngoingSteris Lighting and Visualization Systems, Sterile Light Handle Cover (LB53)- Surgical light handle covers, including disposable surgical light handle covers are designed to fit over surgical light handles for sterile suLight handle covers may separate from the light handle (detach and fall off) during use, this could result in a procedure delay and/or impact the sterile field which could result in an injury to the patientaccessdata.fda.gov
December 12, 202291315Class IIOngoingVERIFY Dual Species Self-Contained Biological Indicators, 50 per box Item Number: S3060 Intended for use in installation testing and routine monitoring of steam and ethylene oxide sterilization processesBiological indicator (BI) used to promote growth of the G. stearothermophilus and B. atrophaeus spores was inconsistent in promoting growth throughout lot, some BIs within the lot performed as intended while others did not. When used to monitor steam and ethylene oxide sterilization cycles, the potential hazard is that the BI will show no growth indicating taccessdata.fda.gov
October 17, 202291020Class IITerminatedGI4000 Electrosurgical Unit - intended to deliver electrosurgical outputs to perform cutting and/or coagulation and coagulation with or without delivery of argon gas, in flexible endoscopic applications. MODEL #(s): G111Two electronic diode components (D1 & D4) placed in the reverse orientation on the controller printed circuit board assembly may result in premature wear of the power regulator, leading to the regulators failure which could cause a full power loss. If the regulator failure were to occur during a patient procedure, a procedural delay may resultaccessdata.fda.gov
September 2, 202290837Class IITerminatedHu-Friedy K360 Scalpel Handle, 360 Degree Scalpel Handle, REF K360The scalpel holder may separate from the handle for certain lots. If the tip falls off during use, it could fall into the patient's mouth which may result in a cut to the patient's mouth and also presents a choking hazard.accessdata.fda.gov
April 22, 202290222Class IITerminatedReliance Synergy Washer/DisinfectorThe firm identified that when the electrical contactor component in the drying chamber of the Washer/Disinfector malfunctions, the heating elements in the drying chamber could overheat, eventually resulting in smoke and/or fire.accessdata.fda.gov
March 22, 202290050Class IITerminatedUltra Pure Non-Woven Sponges Non-Sterile 4-Ply 5,000 per case 25 sleeves of 200 2 in x 2 in / 5.1 cm x 5.1 cm Model Number: ENC100Product not approved for release for US distributionaccessdata.fda.gov
January 21, 202187230Class IITerminatedOT1000 Series Orthopedic Surgical TablesOn January 7, 2021, STERIS identified that the glued bond between the beam and the leg spar assembly may begin to separate over time. This could result in unexpected movement of the affected leg spar if the separation occurred during a patient procedure.accessdata.fda.gov
December 11, 202086937Class IITerminatedReliance Vision Single-Chamber Washer/Disinfector - Product Usage: intended for use in the cleaning and intermediate level disinfection of soiled reusable utensils, trays, glassware, bedpans and urinals, rubber and plastThe electrical contactor component present in the drying chamber of the Reliance Vision Single-Chamber Washer/Disinfector may malfunction, potentially leading to the heating elements in the drying chamber to overheat, eventually resulting in smoke and/or fire.accessdata.fda.gov
December 2, 202086942Class IITerminatedVis-U-All High Temperature Tubing 3"x100'. One roll per box; 10 boxes per case 10 rolls/cs Model Number: 881031Purple ink located on the outside label of Vis-U-All Pouches may migrate ( bleed ) following steam processing causing cosmetic defects on the exterior of the pouch and in some instances, transference of the ink onto the device(s) contained within the pouchaccessdata.fda.gov
November 19, 202086906Class IITerminatedMedisafe Distal Duck Kit and Duck Bag, Cleaner, ultrasonic, medical instrument - Product Usage: intended to keep instruments moist during transportation between point of use and cleaning as an initial step of reprocessinSTERIS has identified that certain lots of diluted 4-Zyme may contain bacteria, specifically Pseudomonas fluorescens. The presence of this bacteria can cause the color of the detergent to darken over time. There is an improbable risk to users of the product from exposure to this bacteria, and no risk to patients.accessdata.fda.gov
October 7, 202086596Class IIITerminatedOlympus Leak Test Adapter used with Acu-sInQ Complete Endoscope Cleaning Aid Systems-intended to assist manual flexible endoscope cleaning Part number: 0600818OKNPotential for cleaning solution intrusion into endoscopeaccessdata.fda.gov
June 26, 202085871Class IITerminatedInnoWave Sonic Irrigator, There are currently six models (PCF, Pro, Ultra, Ultra+, Unity, and ECO) - Product Usage: STERIS InnoWave Sonic Irrigators are intended to thoroughly clean (remove tissue, blood, and other contaA recent FDA inspection at the firm identified that the foil test performed during installation of the device does not have clear acceptance criteria.accessdata.fda.gov
October 22, 201984229Class IITerminatedEvolution Loading Car and Transfer Carriage- Accessory to the Sterilizer, SteamThe locking pin of the front wheel asse mbly of the Evolution Transfer Carriages may not remain full y engaged with the transfer carriage and result in the transfer carriage and loading car unexpectedly falling forwardaccessdata.fda.gov
October 22, 201984185Class IITerminatedEagle 3000 Sterilizer, small steam sterilizer. Product Usage: The Eagle 3000 Small Sterilizer is designed for sterilization of certain materials used in healthcare facilities, and are available in two configurations: GraPotential for the incorrect pressure safety valve being included in the Preventive Maintenance (PM) kit for the 3000 Small Sterilizers.accessdata.fda.gov
December 26, 201882023Class IITerminatedATLAS Loading CarThe ATLAS loading car may not remain fully engaged with the latch on the transfer carriage when the loading car is empty, potentially resulting in the loading car unexpectedly sliding forward or falling to one side.accessdata.fda.gov
December 20, 201882035Class IITerminatedAMSCO 3000 Series Washer/Disinfector Model # 3052The software in the systems may not process the cycle originally intended. This could result in damage to the various medical devices and instruments processed in the washer/disinfector or potential for inadequate cleaning or disinfection.accessdata.fda.gov
July 26, 201880805Class IITerminatedAMSCO V-PRO 1, V-PRO 1 Plus, and V-PRO maX Low Temperature Sterilization Systems The V-PRO 1, V-PRO 1 Plus, and V-PRO maX Low Temperature Sterilization Systems, using VAPROX HC Sterilant, are intended for use in the termThere is the potential for a scenario where a punctured cup of sterilant expires while the system is powered down, upon power-up the unit will not detect the expired cup of sterilant; allowing for subsequent cycles to be run.accessdata.fda.gov
May 23, 201880255Class IITerminatedReliance 1227 Cart and Utensil Washer/Disinfector, FW03101, FW03102, FW03S003 Product Usage: The Reliance 1227 Cart and Utensil Washer/Disinfector is intended for use in the cleaning and low-level disinfection of bedpansThe firm has become aware that the Reliance 1227 Cart and Utensil Washer/Disinfector s Chemical Low Level alarm, intended to prevent the user from initiating a cycle when a low chemical level situation occurs, does not operate as intended. Currently, if a low chemical level situation occurs, the alarm will only be generated at the unit s next power-up or wheaccessdata.fda.gov
September 28, 201779101Class IITerminatedV-PRO 60 Low Temperature Sterilization System (UDI: 00724995152000)Correction to update sterilizer software to prohibit the use of expired sterilant prior to the start of a sterilization cycle.accessdata.fda.gov
June 15, 201779100Class IITerminatedVis-U-All High Temp 7.5"x13" Self Seal Pouch 200 pouches per box; 4 boxes per case Product Usage: The Vis-U-All High Temperature Sterilization Pouch is suitable for use by healthcare providers to enclose and seal medicalOn June 15, 2017, STERIS identified that the purple ink located on the outside label of Vis-U-All Pouches may migrate following steam processing causing cosmetic defects on the exterior of the pouch and in some instances, transference of the ink onto the device(s) contained within the pouch.accessdata.fda.gov
October 5, 201675385Class IITerminatedHarmony Insight Diagnostic Monitor Support System - 100 Spring Arm (EMS) The system is intended for use in surgical operating rooms (OR) or intraoperative surgical/imaging rooms where simultaneous multiple image viewing The Drager Pendula spring arm device has a set of screws located on the spring arm that were not properly secured with Loctite and may become loose.accessdata.fda.gov
May 23, 201674264Class IITerminatedOT1000 Series Orthopedic Surgical TablesSTERIS has identified that the pivot pin assembly located on the table top may become loose preventing the table from articulating properly.accessdata.fda.gov
December 4, 201573009Class IITerminatedQuick Connects. Steris Corporation. Model numbers: QKC1736E, QKC1736INT, QKC1737E, and QKC1737INT. Each Quick Connect contains a flow unit consisting of tubing, tethers, and adapters. For sterilant and rinse water used iThe firm discovered that one of the hysteroscope models listed for processing in four existing Quick Connects has one inlet port rather than two inlet ports as indicated in the Quick Connect processing instructions.accessdata.fda.gov
November 20, 201572825Class IITerminatedAMSCO Warming Cabinet. Manufactured by: STERIS Corporation To raise the temperature of blankets, linens and sterile surgical IV/irrigation solutions to an acceptable level for various surgical, obstetrical, emergency, crThe firm discovered that information printed on the quick reference magnet is incorrect; specifically, Fahrenheit to Celsius temperature conversions and the default Warming Cabinet temperature.accessdata.fda.gov
September 3, 201572217Class IIITerminatedAMSCO 400 and AMSCO C Small Steam SterilizersIn AMSCO Small Steam Sterilizers equipped with the CS-iQ feature, the sterilizer software inadvertently prevents the capability to operate the foot pedal, which allows the Operator to open and close the sterilizer door.accessdata.fda.gov
February 19, 201570938Class IITerminatedAMSCO C and AMSCO 400 Steam Sterilizers, STERIS Corporation. AMSCO C Small Sterilizer, AMSCO 400 Small Sterilizer, AMSCO 400 Medium Sterilizer. Designed for sterilization of heat and moisture-stable materials used in heaSTERIS has identified that the control board software in select AMSCO 400 and AMSCO C units will interrupt and cancel a processing cycle should the selected sterilizer shutdown time coincide with a processing cycle. This may result in a procedure delay.accessdata.fda.gov
February 19, 201570899Class IITerminatedCaviwave Pro Ultrasonic Cleaning System, Product Usage: To wash (remove tissue, blood and other contaminants) or dry laparoscopic and general surgical instruments prior to final disinfection and sterilization as requiredShould the Caviwave Pro Ultrasonic Cleaning System experience a temporary interruption in electrical power during a processing cycle, the circulation pump may stop functioning. In addition, it is possible that the ultrasonic generator may stop working. The machine does not provide an alert notifying the user of this device malfunction.accessdata.fda.gov
November 26, 201469987Class IITerminatedHarmony vLED Surgical Lighting System, one unit packaged per box The Harmony vLED Surgical Lighting System is a variable pattern, variable intensity surgical lighting fixture designed to provide visible illumination of tSTERIS has learned that groups of LED lights (modules) contained within the vLED light head may illuminate inconsistently.accessdata.fda.gov
October 10, 201469472Class IITerminatedThe 5085 is a general surgical table with high patient weight capacity, extended width capability, and lower minimal table top elevation.The 5085 and 5085SRT stainless steel column shrouds may become damaged as a result of misalignment during extreme table articulation, excessive side force on the table column, or pressure on the base of the table. Severe damage to the shrouds may prevent the user from raising or lowering the surgical table.accessdata.fda.gov
June 30, 201468696Class IIITerminatedReliance 1227 Cart and Utensil Washer/Disinfector Product Usage: Usage: The Reliance 1227 Cart and Utensil Washer/Disinfector is intended for use in the cleaning and low-level disinfection of bedpans and urinals, basins,STERIS has identified that deformation of the washers door handle pin may occur when the door handle is rotated with sufficient force. Should deformation and/or breakage of the door handle pin occur there is a potential for the washer door to become inoperable.accessdata.fda.gov
June 27, 201468678Class IITerminatedThe STERIS 4085 General Surgical Table Product Usage: is an electro-hydraulically operated surgical table designed to support all general surgical procedures.STERIS engineering analysis has determined the D1 pressure switch in the hydraulic column manifold does not adequately detect pressure level. If one or more of the table floor lock feet become unlocked due to the loss of hydraulic pressure, there is a potential for the table hand control to incorrectly indicate that the floor lock feet are locked.accessdata.fda.gov
April 4, 201468128Class IITerminatedVertical Spring Arm for Single or Dual Monitor Mount (Harmony LL 500 and Harmony LL 700 surgical lighting systems), Steris Corporation. Model numbers YG19051 and YG19262.Potential for the welded seam in affected monitor spring arms to crack and/or break.accessdata.fda.gov
December 19, 201367308Class IITerminatedVERIFY SixCess 270FP Challenge Pack, STERIS Corporation, 5960 Heisley Road, Mentor, OH 44060,. The VERIFY SixCess 270FP Challenge Pack is used to monitor steam sterilization loads processed at 270F using typical healthcaSTERIS has identified that the outer shipping package for one lot (Lot #024552A) of VERIFY SixCess Challenge Packs incorrectly identifies the lot as Lot #024522A.accessdata.fda.gov
November 21, 201367002Class IITerminatedSYSTEM 1E Liquid Chemical Sterilant Processing System, Distributed by STERIS Corporation, Mentor, OH The SYSTEM 1E Liquid Chemical Sterilant Processing System is intended for the liquid chemical sterilization of manuallyCustomers indicated fluctuations in environmental conditions sites and gradual degradation/deformation of check valve o-rings following frequent contact with S40 sterilant use solution result in nuisance aborts.accessdata.fda.gov
October 18, 201366874Class IITerminatedAMSCO Evolution steam sterilizer Transfer Carriage. Product Usage: Mobile, wheeled transportation unit utilized to carry, load, & unload the Loading Car into and out of steam sterilizer units.The firm discovered that unlatching can occur when overloaded transfer carriages are pulled or maneuvered incorrectly or with excessive force.accessdata.fda.gov
September 10, 201367036Class IITerminatedVERIFY Dual Species Self-Contained Biological Indicator, Distributed by STERIS Corporation, Mentor, OH. Intended for use in installation testing and routine monitoring of steam sterilization and ethylene oxide sterilizatSTERIS has identified that the population of the G. stearothermophilus spores that monitor STEAM sterilization cycles does not meet specifications for Lot # 131004 of the Verify Dual Species Self-Contained Biological Indicators. As a result the spore count on the affected product is lower than the labeled minimum and the product may incorrectly indicate thataccessdata.fda.gov
August 29, 201366247Class IITerminatedReliance Endoscope Processing System (REPS), STERIS Corporation, 5960 Heisley Road, Mentor, OH 44060-1834 USA www.steris.com. The intended use of the REPS is washing and high level disinfection of up to two manually pre-The air pipe that delivers unfiltered ambient air from the procedure room into the water bottle on the listed FUJINON G5 & G8 type flexible GI endoscopes does not connect to the main air/water channel within the light guide (LG) connection head and, as a result, the air pipe does not receive forced flow during the Reliance EPS processing cycle.accessdata.fda.gov
August 15, 201366138Class IITerminatedHarmony Equipment Management System, Model #603X/80XX, STERIS Corporation, Mentor, OH Harmony Equipment Management Systems (EMS) are used in hospital facilities to provide ready access to medical gasses, electrical powerDrger Medical GmbH has notified STERIS of the potential for a break in the drive screw contained in the motorized ceiling supply unit, a component of the Harmony EMS system. The ceiling supply unit controls the motorized adjustment of the height and rotation of the supply column. Should a break occur in the drive screw, there is potential for the adjustable accessdata.fda.gov
May 20, 201365573Class IITerminatedSTERIS Fine Traction Device, one unit per box Product Usage: The Fine Traction Device is used to provide traction and enable fine adjustments to traction and orientation of the leg during orthopedic procedures.A bearing used in the assembly of the Fine Traction Device did not perform successfully in pre-release reliability testing; a replacement bushing passed reliability testing and was substituted per a change order. The change order authorized use of the substitute bushing in assembly of the Fine Traction Accessory; however, inadvertently the new part was not iaccessdata.fda.gov
March 4, 201365138Class IITerminatedQuick Connect QLC1677E, QRC1699E, QPC1721E and QFC1683E. STERIS Corporation, Mentor, OH 44060 QLC1677E, QRC1699E, QPC1721E and QFC1683E contain processing instructions, a Quick Reference Wall Chart and a flow unit. The fDuring a routine label review, the firm identified four SYSTEM 1E Quick Connects that will be updated to reflect the removal of obsolete device models. This labeling review process also highlighted the opportunity to combine two existing quick connects into a single product while eliminating the obsolete models.accessdata.fda.gov
February 12, 201364440Class IITerminatedAMSCO C and AMSCO 400 Steam Sterilizers designed for sterilization of heat and moisture-stable materials used in healthcare facilities.The control boards alarm set points and temperature tolerances allowed for erroneous activation of the AD (analog/digital) alarm as temperature fluctuated during operation. When this alarm occurs, the sterilizer locks up and cannot be used until serviced, causing Customer nuisance.accessdata.fda.gov
August 10, 201262776Class IITerminatedQKC1692E The QKC1692E Quick Connect device connects endoscopes to the sterilization tray for C1220E liquid chemical sterilization processor.STERIS has been actively seeking devices for quick connect revalidation projects. STERIS was unable to obtain two (2) of the needed devices; these two devices represent the design of seven (7) models in one quick connect. Due to the unavailability of these two validation devices, STERIS will remove 7 models from the labeling of QKC1692E and will re-label allaccessdata.fda.gov
August 2, 201262852Class IIITerminated100 ft roll of tubing inside a cardboard box. Medical devices are sealed into the tubes prior to ethylene oxide sterilization. Tube maintains sterility of the enclosed medical devices until opened.On 7/20/2012 the firm became aware that a lot of tubing was distributed by the supplier after it was rejected by Steris due to failing process indicators.accessdata.fda.gov
August 1, 201262895Class IITerminatedThe SYSTEM 1E Liquid Sterilant Processing System. The SYSTEM 1E Liquid Sterilant Processing System is intended for the liquid chemical sterilization of manually cleaned immersible and reusable critical and semi-critical The firm initiated a recall after complaint investigations revealed that when the units are left on and not in use at night and/or on weekends the hose disconnects/separates resulting in water leakage that can cause damage to property.accessdata.fda.gov
July 14, 201262557Class IITerminatedThe Reliance 130 and 130L Cart Washer/Disinfector is a high capacity mechanical washer intended for use in the washing, low-level disinfecting, and drying of carts, utensils, beds and other miscellaneous reusable items uTo ensure that users are properly operating the Reliance 130 and 130L Cart Washers, a door close confirmation button and door open delay will be installed on your cart washer.accessdata.fda.gov
July 3, 201263129Class IITerminatedVerify Bowie-Dick Test Card, Model #S3098, Steris Biological Operations, 9325 Pinecone Drive, Mentor, OH 44060 The Verify Bowie-Dick Test Card consists of a card printed on one side with bars of chemical indicator ink. OSTERIS has learned that the Verify Bowie Dick Test Cards are not performing to product specifications. Specifically, test cards have resulted in false fail results when sterilizer performance is within acceptable ranges.accessdata.fda.gov
April 6, 201263142Class IITerminatedSTERIS 5085 and 5085 SRT Surgical Tables, Product Usage: The 5085 is a general surgical table with high patient weight capacity, extended width capability, and lower minimal table top elevation. It accommodates all generSTERIS has learned from Customer feedback and field service experience that damage from external impact to the table hydraulic column can cause the stainless steel shroud sections covering the table hydraulic column to become misaligned; if the damage is severe, the up/down movement of the table may be impeded. In addition, the table hand control may indicataccessdata.fda.gov
March 23, 201261786Not yet classifiedTerminatedThe Evolution steam sterilizers, manufactured by Steris Corporation, utilize a loading system to assist the operator in transporting, loading and unloading items to be sterilized. It consists of two major components: -LoThrough Customer feedback and field service experience, STERIS learned that operators may experience difficulty when inserting or removing equipment from the Evolution sterilizer using the transfer carriage due to the following issues with the transfer carriage. 1) Deformation of the latch pin or cracked ball bearings preventing the roller from turning. 2) Taccessdata.fda.gov
October 17, 201160305Not yet classifiedTerminatedSTERIS 5085 and 5085SRT Surgical Tables, Catalog Numbers: 5085- ST01-410-1; 5085SRT- ST0-1420-6.Some hydraulic column cylinders installed in certain 5085 and 5085SRT Surgical Tables were assembled by their supplier with incorrect snap rings and an anomaly was present in the tilt cylinder. This error may affect the user's ability to move the table top out of the full right tilt position.accessdata.fda.gov
August 11, 201159752Not yet classifiedTerminatedSYSTEM 1E Liquid Chemical Sterilant Processing System, Model # P6500, S/N: 400001 through 405005; Mfr. By: STERIS Corporation, Mentor, OH 44060. Product Usage: The SYSTEM 1E Liquid Chemical Sterilant Processing System isSTERIS learned that SYSTEM 1E users may experience aborted cycles due to a failure within the UV light system.accessdata.fda.gov
August 1, 201159520Not yet classifiedTerminatedAmsco V-PRO 1 and Amsco V-PRO 1 Plus Low Temperature Sterilization Systems Model #MLR, Serial # 033250701 - 031581115. The STERIS Amsco V-PRO and V-PRO 1 Plus Low Temperature Sterilizer are self-contained stand alone devSTERIS learned that Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems users may experience premature wear of the vacuum pump and filtering assembly components. Users may also experience incomplete aeration of the device's chamber following a failed leak test.accessdata.fda.gov
May 9, 201159570Not yet classifiedTerminatedReliance Vision Single Chamber Washer/Disinfector, Model # 1802983, The Vision Single Chamber Washer is intended for use in the cleaning and intermediate level disinfection of soiled reusable utensils, trays, glassware, STERIS learned that Vision SC Washer users were experiencing nuisance alarms and/or aborted cycles that are adversely affecting the reliability and operation of their unit.accessdata.fda.gov
March 16, 201159713Not yet classifiedTerminatedVerify SixCess Indicator Strips, Model #: PCC005, PCC006, PCC007, PCC008, PCC031, PCC033, PCC034, PCC037 & PCC038, Mfr. By: Albert Browne, LTD, Chancery House 190 Waterside Rd. Hamilton Industrial Park, Leicester, LeicesDuring an inspection the firm was notified that language contained in labeling and promotional literature directs Customers that the products can be used to replace biological indicators and/or release loads containing implants.accessdata.fda.gov
February 18, 201158107Not yet classifiedTerminatedHarmony LA/LED Monitor Arm Adapter. Model Number: LB61 The Harmony LA/LED Monitor Arm Adapter is an accessory to the Harmony LA and LED Surgical Lighting System and is attached to the end of the monitor suspension arm toThe arm adapter does not contain labelling specifying the applicable weight and moment limitations of the arm adapteraccessdata.fda.gov
August 12, 201056659Not yet classifiedTerminatedCmax Surgical Tables, Model #'s: Cmax110, Cmax 220 manufactured by Steris Corporation in Montgomery, ALCmax Surgical Tables may lose calibration if the table is operated only on battery power and if the table is in a low battery charge condition. This could result in the table moving into an unexpected tilt position when the Level button is depressed on the hand control keypad.accessdata.fda.gov
July 2, 201056245Not yet classifiedTerminatedSteris Reliance EPS Endoscope Processing System, manufactured by Corporation STERIS Canada, Quebec, Canada. Washing and high level disinfection of up to two manually pre-cleaned, immersible, reusable, heat-resistant, semReliance EPS had internal water leaks and interrupted cycles when air leaks triggered false Fault 38 alarm that DG/HLD cup has not been replaced.accessdata.fda.gov
May 14, 201055850Not yet classifiedTerminatedSTERIS 4085, 5085 & 5085SRT Surgical TablesSTERIS has learned that a limited quantity of manifold assemblies were manufactured by our supplier with incorrect washers and springs in the valves of the manifold. This supplier error has the potential to cause: a) an inability to articulate/move a table section when commanded by the operator; b) two different articulations occurring when a single articulaaccessdata.fda.gov
February 23, 201054742Not yet classifiedTerminatedHarmony Lux Advantage LA Surgical Lighting and Visualization System, also known as the Harmony LA 500, B129382391. Designed to provide visible immunization of the surgical field or the patient and to provide audio-visualPremature Bulb Failureaccessdata.fda.gov
February 17, 201054705Class IITerminatedA mobile, electro-hydraulically operated, fluoroscopic/C-Arm compatible general surgical table. Product Usage: Product provides a flexible, easy-to-use, articulated posturing of a patient for either general, I.A., or speCustomers may be storing objects on the base and/or around the column of the surgical table. This prohibited practice and misuse known by the customers can damage the override switch assembly located at the top of the column cover. Depending upon the nature and severity of the damage to the electronics of the table, it is possible that the table could move waccessdata.fda.gov
September 11, 200953475Not yet classifiedTerminatedSTERIS Harmony LL 500/700 Surgical Light, Vertical Spring-Loaded Arm. Intended for local illumination of the operating and examination area of the patient in treatment rooms.Drger Medical AG & Co., KGaA informed STERIS Corporation that they received (4) reported international cases where a welded seam at the joint of the spring-loaded arm of the Drger SOLA 500/700 surgical light broke as a result of a crack that had slowly developed over time. The STERIS Harmony LL 500/700 surgical light is a Private Label version of the Drger Saccessdata.fda.gov
May 12, 200952172Not yet classifiedTerminatedCmax 110v Surgical Table Hand Control. The Cmax Surgical Table is a mobile, electro-hydraulically operated surgical table designed to support all general surgical procedures, with the addition of STERIS table accessoriesA limited quantity of the Cmax Hand Controls, P150832-500, were manufactured without Loctite thread locker on the screws that attach the mounting clip to the hand control case. This clip provides a means of storing the hand control on the table side rails. It is possible that screws without Loctite can work loose and the clip can become separated from the haaccessdata.fda.gov
April 17, 200951953Not yet classifiedTerminatedASC2000 Ambulatory Surgical Table. Model #MTS110003. The device is used to provide complete and flexible positioning for surgical procedures.Upon investigation, the firm determined that repetitive rubbing of the hydraulic hoses against the interior of the stainless steel shroud may result in the rupture of the hydraulic hoses causing loss of control of the table surface.accessdata.fda.gov
August 4, 200849390Not yet classifiedTerminatedQuick Connect component p/n 201048. The component is contained in QPC1713 and QPC1724 Quick Connects. The QPC1724 is used to attach Pentax 70/70K/72/72K/80K/81K/90i/90K SERIES GI ENDOSCOPES WITH WATER JET to the C1160 UnDuring ongoing product development testing, it was discovered that, when the two inflow barbs on adapter 201048 # 4 are in a position to face one direction, the top Barblock may interfere with the top surface of bottom barb of the adapter. The interference may cause the plunger on the suction side to lift slightly which may affect flow of sterilant into the accessdata.fda.gov
March 6, 200848999Not yet classifiedTerminatedSteris Small Renaissance Eagle 3000 -- Remanufactured Gravity Models 3011 and 3021 and Prevacuum Models 3013 and 3023. Products are designed for efficient sterilization of non-porous and porous, heat and moisture-stable The firm discovered that some Eagle 3000 units may have a door post pin missing which could cause incomplete or no engagement of the radial arms into the lock rails of the door. The sterilizer is designed with switches that prevent cycle initiation if the door is not locked. However, in the event the door switches are not properly adjusted they may falsely iaccessdata.fda.gov
February 19, 200846753Not yet classifiedTerminatedSteris C1160 Universal Flexible Processing Tray, for use with STERIS SYSTEM 1 Processor, used for sterilization of flexible endoscopes.Failure to effectively sterilize: Under certain conditions, the design/operation of the C1160 Tray may compromise the ability of the SYSTEM 1 processor to correctly assess the state of the high pressure pump during the Sterile Cycle. The L6 sensor fails to alarm when the high pressure pump is not working properly.accessdata.fda.gov
March 22, 200738031Not yet classifiedTerminatedAmsco Century Medium Steam Sterilizer (26" x 37.5") (660 x 950mm).The cables inside the pump conduit box may be exposed (not covered with wire nut and/or electrical tape) that could cause a potential electrical shock hazard.accessdata.fda.gov
February 23, 200737493Not yet classifiedTerminatedSteris QFC1728 and QFC1729 Quick Connects used in connections and processing endoscopes. The QFC1728 is used to process the Fujinon 250/270/450/470/490 Group 5 and 530/590 series GI Endoscopes w/o Water Jet. The QFC1729 The center insert of the adaptor #6 restrictor could become loose and/or come out of the housing and may affect the sterilization process of the attached endoscopeaccessdata.fda.gov
March 15, 200428569Not yet classifiedTerminatedQPC1680 Quick Connect, for Pentax 30/40/K Series Two-Channel GI Endoscopes, in the Steris System 1 Sterile Processing System with the C1160 Universal Flexible Processing Tray, Cat No. QPT1680A defective port adapter may affect the sterilization process of the attached endoscope.accessdata.fda.gov
April 23, 200326151Not yet classifiedTerminatedC1141 Flexible Endoscope Processing Container, designed to fit the Steris System I Processor. The unit may be sold individually or with the processing tray assembly (C1140).The container flow port is inverted, which restricts the flow of sterilant to the endoscope and affects the sterilization process.accessdata.fda.gov
March 20, 200325946Not yet classifiedTerminatedQFC1631, QFC1683, QFC1685 Quick Connects for use with Fujinon gastrointestinal endoscopes, for use with the STERIS SYSTEM I Processor and the C1160 Universal Flexible Processing Tray. The QFC1631 is for Fujinon 450/485 SThe defective device may restrict the flow of sterilant to the attached endoscope and affect the sterilization process of the scope.accessdata.fda.gov
March 7, 200325374Not yet classifiedTerminatedC1406, QLC1406, C1473, and QLC1473 Quick Connect for Olympus 30/40/160/200/240 Series Bronchoscopes in the C1140 Universal Processing Trays. Catalog numbers: C11473 and QLC1473.The Steris device may not attach properly to retrofitted Olympus bronchoscopes, and become loose during the sterile processing cycle.accessdata.fda.gov

Compare with other makers

Updated October 7, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.