SPINEFRONTIER, INC. DBA LESspine Innovations: FDA-registered device maker in Burlington, MA, United States, 7 510(k) clearances

SPINEFRONTIER, INC. DBA LESspine Innovations is registered with the FDA (registration 3005977257) in Burlington, MA, United States. It lists 13 device types. The FDA files 7 510(k) clearances under its listings, the newest dated August 27, 2025. 26 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3005977257
Address
200 Summit Drive Suite 505, Burlington, MA, United States, 01803
Owner or operator
LESspine Innovations (9094359)
Roles
Manufacturer, Specification developer
First device listed
August 18, 2008
Registered through
2026
Brand names listed
A-CIFT SoloFuse, Arena-C, Arena-C HA, Arena-L, Dorado, E-LIFT, ELID, Endoscopic Less Invasive Decompression and more

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
August 27, 2025K243774ELID (Endoscopic Less Invasive Decompression) SystemHRXSubstantially EquivalentLesspine Innovationsaccessdata.fda.gov
September 28, 2023K232605Sacrix® Sacroiliac Joint Fusion Device System, Inspan® ScrewLES Fusion System, Invue® MAX™ + Invue Inset Anterior Cervical Plate System, and FacetFuse® Screw Fixation SystemOURSubstantially EquivalentLesspine Innovationsaccessdata.fda.gov
June 19, 2020K193106SpineFrontier Lumbar Interbody Fusion Device SystemMAXSubstantially EquivalentSpinefrontier, Inc.accessdata.fda.gov
May 8, 2018K172484A-CIFT SoloFuseOVESubstantially EquivalentSpinefrontier, Inc.accessdata.fda.gov
February 12, 2015K143377PedFuse Pedicle Screw SystemMNHSubstantially EquivalentSpinefrontier, Inc.accessdata.fda.gov
October 20, 2014K142026SPINEFRONTIER ARENA-C HA PEEK CERVICAL INTERVERTEBRAL BODY FUSION DEVICEODPSubstantially EquivalentSpinefrontier, Inc.accessdata.fda.gov
September 8, 2014K141337ARENA-CODPSubstantially EquivalentSpinefrontier, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
June 13, 201983166Class IITerminatedA-CIFT SoloFuse Fixed Angle Driver, Model Number 13-32101-01 (Component Part Numbers 14-32107-01 and 14-32106)There is a potential for the driver to bind up when attempting to advance the intervertebral body fixation screw.accessdata.fda.gov
March 5, 201570488Class IITerminatedSpineFrontier MISquito Percutaneous Pedicle Screw System Surgical Technique; Part Number: DOC80023. The Rod Caliper is a manual surgical instrument that may be used as part of the PedFuse Pedicle Screw System and its MISThe PedFuse Pedicle Screw Rod Caliper included with the MISquito Pedicle Screw System may be used incorrectly as the Surgical Technique does not adequately convey the intended use of the design.accessdata.fda.gov
December 19, 201470065Class IITerminatedlnline Persuader- PedFuse Pedicle Screw System; Part Number: 11-80164A crack may develop in the handle to the Inline Persuader, which may progress if the user continues to use the affected instrument.accessdata.fda.gov
November 20, 201366914Class IITerminatedIndus Invue Screws: IM71058-XX: 04.2mm, SelfTapping, Tapered. Used to secure the Invue Anterior Cervical Plate in position.Mismarked and unmarked screwsaccessdata.fda.gov
November 20, 201366873Class IITerminatedPedFuse Reset Screw Inserters; PedFuse Screw Inserter 05-7 REset Part #11-80110 The PedFuse Screw Inserter 05-7 REset, Screw Inserter 05-7 REspond, and Screw Inserter 08-9 REset are used as a screw capture, screw driver,Screw inserters may not mate properly with hex interface of the screws.accessdata.fda.gov
October 18, 201366698Class IITerminatedPedFuse Reset Screw; Model: 01-80115-55 The PedFuse Reset pedicle screw implants intended to be used to help provide immobilization and stabilization of spinal segments as an adjunct to fusion of the thoracic, lumbar, anDuring routine servicing, it was discovered that one 8mmx55mm Reset screw was assembled with an 8mm tulip head and a 9mm screw. The implant should have consisted of an 8mm tulip head and an 8mm screw. A recall was initiated to remove all remaining screws of the same lot from the field to investigate the nonconformity.accessdata.fda.gov
September 24, 201366298Class IITerminatedArena-L Trial Handle; Part: 11-81002 The trial heads are smooth plates that mimic the footprint of the implant, manufactured from 17-4 Stainless Steel into 35X26mm (11-81004-XX) and 38X28mm (11-81012-XX) varieties, each Handles and heads may not be compatible.accessdata.fda.gov
September 11, 201366273Class IITerminatedPedFuse Bone Probe; Part: SI81008 spinal pedicle fixation.Bone Probes used to create a pathway in pedicle bone were manufactured and marked to incorrect specifications.accessdata.fda.gov
August 28, 201365760Class IITerminatedS-LIFT Extension Shims Extension shims are manufactured from grade 5 titanium and are curved, rectangular slabs which have four protrusions used for ratcheting. They come in straight and pointed varieties, either with orFit variation among all lots of S-LIFT extension shims with corresponding retractor blades. The firm's investigation revealed that extension shims may not fit down all retractor blades.accessdata.fda.gov
June 21, 201365653Class IITerminatedIndus Invue Screw Caddy, Model: SI70097 The caddy holds, in an organized fashion within the case, a variety of shapes and sizes of plates and screws used during fixation of anterior cervical plates to provide stabilizatiDifficulty removing screws from the Invue caddies.accessdata.fda.gov
May 24, 201365429Class IITerminatedS-LIFT Inserter Outer Sleeve Product Usage: The Inserter Sleeve is an optional instrument to add further compression of the Inserter into the Implant during implantation of S-LIF Intervertebral Body Fusion Devices using The outer sleeve would not fit over the S-LIFT Inserter assembly because the hole at the top of the sleeve handle was too small.accessdata.fda.gov
May 17, 201365432Class IITerminatedBASE, S-LIFT Instrument Case Product Usage: System cases are designed to hold and secure all instrumentation to be used with a surgical system. Case and caddy components are used to contain implants intended for interverThe S-LIFT Instrument Case contained a bracket with peeling nylon coating.accessdata.fda.gov
May 10, 201365444Class IITerminatedInvue Split Driver, Assembly with Handle, Model SI70006 Rev G. Used in conjunction with the Invue Anterior Cervical Plate System under 501(k) clearance number K121060. The Invue Driver is an instrument consisting of a RaDevice design.accessdata.fda.gov
May 7, 201365442Class IITerminatedInSpan Inserter, Right Assembly; InSpan Inserter, Left Assembly Product Usage: Inserters are stainless steel instruments that have an inner shaft. The left and right inserters are used in combination with each other to pPotential for set screw to be come deformed.accessdata.fda.gov
April 25, 201365033Class IITerminatedS-LIFT Slap Hammer, Part Number: 11-50204, Revision A The slap hammers are used primarily to remove trial instruments that are used to estimate sizes of intervertebral body fusion devices intended to promote fusion. ThesMalfunction of slap hammer.accessdata.fda.gov
April 22, 201364970Class IITerminatedCase Lid and Base (Inspan, Invue, SLIFT) Caddy Lid (Inspan, Arena-C); Inspan Lid: 12-60039A, 11-60042B, 11-60043B, 11-60045B, 11-60046C, 11-60045A, 11-60046A, 11-60053A; Invue Lid: SI70095A; S-Lift Lid: SI50070A; S-Lift Non-toxic inks, used on the silk screen graphics of the case bases and lids, and caddy lids, were found to be either delaminating or running off from the substrate after repeated washing and sterilization cycles.accessdata.fda.gov
March 14, 201364984Class IITerminatedRev E PedFuse Return Screw Inserter, Part Number: 11-80030 Screw inserters are instruments which capture, hold and drive pedicle screw assemblies. There is a capturing feature that engages and holds the screw in place. TInserters have a set screw that fixes a collar to the inserter. The screw set can loosen and fall out of the inserter which allows the collar to slide off the proximal end of the inserter. When the collar is not in place the locking sleeve can also slide off the inserter.accessdata.fda.gov
November 9, 201264985Class IITerminatedDrill Guide - Chameleon FacetFuse Fixation System, Model: 11-00028 Rev. A FacetFuse Drill Guides were designed to provide a concentric pathway for the drills and taps to access the bone while protecting the soft tissue fPrior to use in surgery, the Drill Guides were presenting noticeable degrees of denting and/or bending. As a result, drills and taps could not be directed down guides during surgery due to mechanical interference.accessdata.fda.gov
October 5, 201264987Class IITerminatedCaddy - PedFuse, Screw Caddy, 8MM and 9MM, Part Number: 11-80009 Rev. B The caddy holds, in an organized fashion within the case, 8mm and 9mm pedicle screws used during implantation of pedicle screw system devices intendTwo sections that are designated for the 8mm and 9mm screws were switched; the holes that hold the 8mm screws are designed for 9mm screws, and the holes that hold the 9mm screws are designated for 8mm screws.accessdata.fda.gov
August 29, 201264993Class IITerminatedT-Handle, Strike Plate, Push Connection, Part Number: SI50023 Rev A T-handles are silicone handled instruments that have a quick release end. The silicone T-handle has an impactor cap on the proximal end of the handle whDuring an operation the strike plate of a T-Handle loosened and separated from the T-Handle.accessdata.fda.gov
August 28, 201263144Class IITerminatedSpine Frontier Inspan compressors Part Number: 11-60004. Inspan compressors provide pressure to drive spikes of Inspan implants into the spinous process bone, resulting in fixation of the implant.Inspan Compressors may break at weld causing a loss of compressionaccessdata.fda.gov
August 22, 201263075Class IITerminatedS-Lift Implant Guides (also known as S-LIF) Compressor Part Number: 11-50223 Product Usage: Surgical Guides allow a surgeon to place implants into tight spaces, such as a vertebral disc space, without having the implant When using the optional S-LIFT (also known as S-LIF) Implant Guides without stops, there is a known risk of moving the Implant Guides, and possibly the implant, too far into the disc space creating the potential for injury to the patient. The instructions for Use for the S-Lift Implant Guides will be amended to add the following warning: "Care is to be takenaccessdata.fda.gov
May 9, 201264994Class IITerminatedInvue Solid Driver, Tipped, AO. Part Number: 11-70083. Allows the user to retain the screw when changing axis of insertion during fixation of spinal intervertebral.The nipple of the tipped driver broke off when surgeons were attempting to insert the screw.accessdata.fda.gov
December 30, 201164989Class IITerminatedKRD1 PedFuse Rods, Model: IM80100-13 Rev B Product Usage: Pedicle rods are cylindrical rods which act as a linking mechanism between pedicle screws. The rod sits with the pedicle screw tulip and they are locked into placOne of the rods in each of two test constructs did not meet fatigue requirement as outlined in ASTM F1717-04 dynamic compression testing 5 million cycles.accessdata.fda.gov
December 23, 201163145Class IITerminatedSpineFrontier S-Lift Lock Shaft Inserter, an instrument used with S-LIFT Intervertebral Body Fusion Device in spinal fusion surgery. Product Usage: The S-Lift Lock Shaft SI50001 mates with SI50002, Implant Inserter, to aIt has been verified through field use that there are two possible breakages that may occur when using SI50001 Revision D Lock Shaft Inserter, possibly resulting in instrument fragments entering the sterile field: Impact Cap: The impact cap on the Lock Shaft Inserter can shear off under high-impact force during insertion and removal. Pin: The pin used to guiaccessdata.fda.gov
May 10, 200864991Class IITerminatedStraight Impactor - Dorado IBC, Part Number: SI02140. The device is used to position implants after they have been inserted into the disc space during implantation of intervertebral body fusion devices.During two separate occasions an impactor plate on the handle broke off while being struck by a mallet.accessdata.fda.gov

Compare with other makers

Updated August 27, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.