Data / Medical devices / Germany / SPIEGELBERG GmbH & Co. KG

SPIEGELBERG GmbH & Co. KG: FDA-registered device maker in Hamburg, Germany, 1 510(k) clearance

SPIEGELBERG GmbH & Co. KG is registered with the FDA (registration 3002108226) in Hamburg, Germany. It lists 2 device types. The FDA files 1 510(k) clearance under its listings, the newest dated June 28, 2001. 1 recall event names it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3002108226
Address
Tempowerkring 4, Hamburg, Germany, 21079
Owner or operator
Spiegelberg GmbH & Co. KG (10037562)
Roles
Exporter to the US, Manufacturer
First device listed
July 26, 2011
Registered through
2026

Devices it lists

DeviceProduct codeClassRoleSource
Device, Monitoring, Intracranial PressureGWM2Manufactureraccessdata.fda.gov
Instrument, MicrosurgicalGZX1Exporter to the US, Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
June 28, 2001K003759AESCULAP SPIEGELBERG BRAIN PRESSURE MONITORGWMSubstantially EquivalentAesculap, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
December 29, 200975160Class IITerminatedSpiegelberg Brain Pressure Monitoring System Probe 3PN, REF: SNDI3.1.531FV534P and Probe 3PS, REF: SNDI3.1.63/FV535P Product Usage: lntracranial pressure measuring probes are used to measure intracranial pressure (intracIn the vast majority of products specified, a shrinkage of the air chamber during sterilization has occurred. Because of these false high readings were displayed in the lower measuring range from 0 to 20 mmHg. The observed measurement error was particularly at the lowest end of the range (to 0 mmHg) up to 8 mmHg.accessdata.fda.gov

Compare with other makers

Updated June 28, 2001. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.