Skip to the page

Data / Medical devices / United States / Spectranetics Corp.

Spectranetics Corp.: FDA-registered device maker in Colorado Springs, CO, United States, 28 510(k) clearances and 2 PMA approvals

Spectranetics Corp. is registered with the FDA (registration 3007284006) in Colorado Springs, CO, United States. It lists 12 device types. The FDA files 28 510(k) clearances and 2 PMA approvals under its listings, the newest dated June 24, 2025. 17 recall events name it as the recalling firm (2 Class I). Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3007284006
Address
9965 Federal Drive, Colorado Springs, CO, United States, 80921
Owner or operator
Philips Medical Systems International BV (2939520)
Roles
Complaint file establishment, Manufacturer, Specification developer
First device listed
May 21, 2015
Registered through
2026
Brand names listed
Bridge Occlusion Balloon, Bridge Plus Occlusion Balloon Catheter, Bridge Prep Kit, CVX-300 Excimer Laser System, CavaClear Laser Sheath, ELCA Coronary Laser Atherectomy Catheter, GlideLight Laser Sheath, LLD E Lead Locking Device and more

Devices it lists

DeviceProduct codeClassRoleSource
Aspiration Thrombectomy CatheterQEZ2Complaint file establishment, Manufactureraccessdata.fda.gov
Catheter For Crossing Total OcclusionsPDU2Complaint file establishment, Manufactureraccessdata.fda.gov
Catheter Introducer KitOFC2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Catheter, Intravascular Occluding, TemporaryMJN2Complaint file establishment, Manufactureraccessdata.fda.gov
Catheter, PercutaneousDQY2Complaint file establishment, Manufactureraccessdata.fda.gov
Catheter, Peripheral, AtherectomyMCW2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Device, Angioplasty, Laser, CoronaryLPC3Complaint file establishment, Manufactureraccessdata.fda.gov
Device, Removal, Pacemaker Electrode, PercutaneousMFA3Complaint file establishment, Manufactureraccessdata.fda.gov
Dilator, Vessel, For Percutaneous CatheterizationDRE2Complaint file establishment, Manufactureraccessdata.fda.gov
Laser-Powered Inferior Vena Cava Filter Retrieval CatheterQRJ2Complaint file establishment, Manufactureraccessdata.fda.gov
Stylet, CatheterDRB2Complaint file establishment, Manufactureraccessdata.fda.gov
Wire, Guide, CatheterDQX2Complaint file establishment, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
June 24, 2025K251358Bridge Plus Occlusion Balloon (590-002)MJNSubstantially EquivalentPhilips Image Guided Therapy Devicesaccessdata.fda.gov
March 13, 2025K250385Turbo-Elite Laser Atherectomy CatheterMCWSubstantially EquivalentSpectraneticsaccessdata.fda.gov
December 8, 2022K222837Turbo-Power (2.0mm) Laser Atherectomy Catheters, Turbo-Power (2.3mm) Laser Atherectomy CathetersMCWSubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
December 21, 2021DEN210024CavaClear Laser SheathQRJUnknownSpectranetics, Inc.accessdata.fda.gov
June 14, 2021K2115182.4mm X 130cm Phoenix Deflecting Atherectomy System, 1.5mm X 149cm Phoenix Atherectomy SystemMCWSubstantially EquivalentVolcano Atheromed, Inc.accessdata.fda.gov
December 23, 2020K203540Bridge Occlusion BalloonMJNSubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
December 20, 2018K182972Phoenix Atherectomy SystemMCWSubstantially EquivalentVolcano Atheromed, Inc.accessdata.fda.gov
April 5, 2018K180694Turbo-Power (2.0mm) Laser Atherectomy Catheters, Turbo-Power (2.3mm) Laser Atherectomy CathetersMCWSubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
August 24, 2017K1723861.8mm X 149cm Phoenix Atherectomy System, 2.2mm X 149cm Phoenix Atherectomy System, 2.4mm X 130cm Phoenix Atherectomy SystemMCWSubstantially EquivalentVolcano Atheromed, Inc.accessdata.fda.gov
April 7, 2017K170059Spectranetics Turbo-Elite Laser Atherectomy CathetersMCWSubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
July 8, 2016K161333TightRail Sub-C Rotating Dilator SheathDRESubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
February 5, 2016K153530Bridge Occlusion BalloonMJNSubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
May 26, 2015K1511452.4mm X 127 cm Phoenix Atherectomy Deflecting SystemMCWSubstantially EquivalentVolcano Atheromed, Inc.accessdata.fda.gov
March 4, 2015K150360TightRail Rotating Dilator Sheath, TightRail Mini Rotating Dilator SheathDRESubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
February 27, 2015K150201Quick-Cross Extreme Support Catheter, Quick-Cross Select Support CatheterDQYSubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
December 19, 2014K1433281.8mm X 149 cm Phoenix Atherectomy Catheter, 2.2mm X 149 cm Phoenix Atherectomy Catheter, Phoenix Handle, Phoenix Wire Support ClipMCWSubstantially EquivalentVolcano Atheromed, Inc.accessdata.fda.gov
August 22, 2014K1409441.8 MM PHOENIX ATHERECTOMY CATHETER, 2.2 MM PHOENIX ATHERECTOMY CATHETER, PHOENIX HANDLE, PHOENIX WIRE SUPPORT CLIPMCWSubstantially EquivalentAtheromed, Inc.accessdata.fda.gov
August 12, 2014K142116LLD EZDRBSubstantially EquivalentSpectranetics, Inc.accessdata.fda.gov
January 25, 2013K1236322.5MM TURBO ELITE 035, 2.3MM TURBO ELITE 035MCWSubstantially EquivalentSpectranetics Corp.accessdata.fda.gov
March 26, 2010K093257TORQMAX SHEATH GRIP ACCESSORYOFCSubstantially EquivalentSpectranetics Corp.accessdata.fda.gov
November 2, 2009K092378SPECTRANETICS VISISHEATH DILATOR SHEATHDRESubstantially EquivalentSpectranetics Corp.accessdata.fda.gov
March 28, 2008K073519QUICKCAT EXTRACTION CATHETER, MODEL 60090-01QEZSubstantially EquivalentKensey Nash Corp.accessdata.fda.gov
February 26, 2008K080144MANDREL GUIDEWIRES OR M-WIRESDQXSubstantially EquivalentLake Region Mfg., Inc.accessdata.fda.gov
December 4, 2007K072750SPECTRANETICS QUICK-CROSS SUPPORT2 CATHETERS, MODELS 518-065 AND 518-066DQYSubstantially EquivalentSpectranetics Corp.accessdata.fda.gov
July 11, 2007K071227CLIRPATH TURBO EXCIMER LASER CATHETER (RX) -0.9MM, (RX) -1.4MM, (RX) -1.7MM, (RX) -2.0MM, MODEL 310-154, 314-159, 317-15PDUSubstantially EquivalentSpectranetics Corp.accessdata.fda.gov
March 16, 2005K043401SPECTRANETICS LLD CS, MODEL 518-039DRBSubstantially EquivalentSpectranetics Corp.accessdata.fda.gov
February 23, 2004K033678SPECTRANETICS QUICK CROSS CATHETERS, MODELS 518-032, 518-033, 518034, 518-035, 518-036, 518-037 AND 518-038DQYSubstantially EquivalentSpectranetics Corp.accessdata.fda.gov
October 22, 1999K990713SPECTRANETICS LEAD LOCKING DEVICE (LLD) #1, #2, #3 LISTERDRBSubstantially EquivalentSpectranetics Corp.accessdata.fda.gov

PMA approvals

Premarket approvals this establishment lists, with the supplements the FDA has decided since.

ApprovedPMA numberDeviceProduct codeSupplementsLatest decisionSource
December 9, 1997P960042SPECTRANETICS CVX-300 EXCIMER LASER SYSTEM & LASER SHEATHMFA67December 18, 2025accessdata.fda.gov
February 19, 1993P910001SPECTRANECTICS CVX-300 EXCIMER LASER SYSTEMLPC114August 21, 2026accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
January 10, 202596097Class IOngoingIntact Vascular Tack Endovascular System, to treat vascular dissections with Tack implant(s) following angioplasty: (4F,1.5-4.5mm), 150cm, REF: 154150041; Tack, 4F Gen 1.5, 150cm CE, REF: 154150042; Tack, 4F Gen 1.5, 90cUse of Tack Endovascular system, designed to treat acute dissections of inner wall or lining of an artery by tacking damaged tissue to inner luminal surface, could result in problems with deployment and stability of device in vessel after deployment, which may cause failure to resolve dissection, migration of implant, bailout stenting, reintervention, uninteaccessdata.fda.gov
November 25, 202495815Class IIOngoingTurbo Elite Laser Atherectomy Catheter Model Number / UDI-DI code / Product Description / 989930000531 / 1.4 mm OTW / 989930000551 / 1.7 mm OTW / 989930000571 / 2.0 mm OTW / 989930000591 / 2.3 mm OTW / 989930000601 / 2.5Due to complaints received for the marker band detaching from the distal tip of the catheter and remaining in the patient as laser catheter was retracted.accessdata.fda.gov
November 15, 202393373Class IIOngoingSpectranetics Turbo-Elite Laser Atherectomy Catheter 2.0 RX REF Spectranetics Turbo-Elite Laser Atherectomy Catheter 2.0 OTW REF Spectranetics Turbo-Elite Laser Atherectomy Catheter 1.4 RX REF Spectranetics Turbo-Elite LIncorrect product labeling. Exterior product box label does not match internal pouch label.accessdata.fda.gov
October 14, 202290971Class IIOngoingPhilips Laser System, REF: LAS-100. Used in minimally invasive interventional procedures within the cardiovascular system, and for the removal of problematic pacemaker and defibrillator cardiac leads.Laser System may detect Error 106 or Error 108 System Failures that will cause the system to enter non-recoverable safe state. The user will not be able to proceed until the error is cleared. May result in initiation of treatment delay and/or treatment beyond initial scope and/or unable to treat patient.accessdata.fda.gov
June 1, 202290364Class IIOngoingPhilips Laser System, REF LAS-100, Intermittent Operation, Duty cycle dependent upon device in use 100 - 240 VAC, 50/60HZ, 16 AMThe LAS-100 Laser system may detect an inoperable hardware component during power up, which results in an error code and the system not being operable until code is cleared.accessdata.fda.gov
March 31, 202085477Class IITerminatedBridge Occlusion Balloon, REF, QTY 1, Sheath Compatibility 12F, Guidewire Compatibility 0.035 in, Working Length 90 cm, Balloon Outer Diameter 31 mm, Balloon Length 80 mmm, Rx ONLY, CE Marking, Sterile EO, UDI: 008131320There is a potential for thrombus formation on balloons prepped and staged in the vasculature for long durations. All users, such as those performing lead extraction cases may not be aware of this risk. It was determined that current labeling is insufficient to ensure all potential users minimize the time the balloon remains in vasculature. If left in too loaccessdata.fda.gov
August 7, 201777934Class ITerminatedSpectranetics Bridge Occlusion Balloon catheter, Sheath Compatibility 12F, Guidewire Compatibility 0.035in, Working Length 90cm, Balloon Outer Diameter 31mm, Balloon Length 80mm, Rx Only. Product Usage: It is a device usPossible inability to pass the guidewire through the Bridge device, therefore, resulting in a potential delay of treatment.accessdata.fda.gov
June 6, 201777474Class IITerminatedSpectranetics Turbo-Elite Laser Atherectomy Catheter Peripheral Rapid Exchange Catheters Device is indicated for use in the treatment, including atherectomy, of infrainguinal stenosis and occlusionsPotential for flouroscopially visible marker band at the tip of the Rapid Exchange Turbo Elite Atherectomy Catheters to become loose or disengaged rom the catheter when the device is in use in an off-label manner.accessdata.fda.gov
October 31, 201675617Class IITerminatedTurbo Elite Atherectomy Catheter. Models:,,,,,,,,, 423-135-01 The Laser Catheters are used in conjunction with the Spectranetics CVX-300 Excimer Laser System and are intended for use in patients with single or multivesseSpectranetics Corporation announces a voluntary field action for the Turbo Elite Atherectomy Catheter, ELCA Coronary Atherectomy Catheter, and Bridge Occlusion Balloon due to potentially compromised integrity of the outer sterile packaging.accessdata.fda.gov
January 15, 201673098Class IITerminated2.3mm Turbo-Power OTW, Manual, Model No Product Usage The Turbo-Power System (Laser Atherectomy Catheter) is a laser atherectomy device designed for use with the CVX-300" Excimer Laser System. The Turbo-Power Laser AtherThe product is labeled with an expiration date that is past its shelf life.accessdata.fda.gov
March 13, 201261408Not yet classifiedTerminated12Fr SLS II Laser Sheath. The laser sheath is intended for use as an adjunct to conventional lead extraction tools in patients suitable for transvenous removal of chronically implanted pacing or defibrillator leads constIsolated lots of the 12Fr SLS II Laser Sheath can have a split in the outer jacket.accessdata.fda.gov
July 18, 201159382Not yet classifiedTerminatedSpectranetics Turbo-Booster Laser Guide Catheter, 7 Fr, REF, Sterile EO, Spectranetics Corporation, 96 Talamine Court, Colorado Springs, CO 80907. Designed for directing and supporting Spectranetics laser catheters for uPackaging integrity may be compromised, thus sterility can not be assured.accessdata.fda.gov
July 1, 201056115Not yet classifiedTerminatedSpectranetics Corporation, QuickCat Extraction Catheter, REF 60090-01, Sterile R, Working Length 145cm, for embolus and thrombus removal from arterial vessels.Guidewire lumen may be occluded, preventing guidewire insertion into the catheter.accessdata.fda.gov
March 16, 200951438Not yet classifiedTerminatedSpectranetics SLS II Laser Sheath Kit, 14F, REF, Individually packaged catheter introducer.Catheter outer jacket may split during use.accessdata.fda.gov
October 15, 200850512Not yet classifiedTerminatedSpectranetics SLS II 14Fr. Laser Sheath Kit, REF, Sterile EO, individually packaged, Lot number 080314B, Spectranetics, 96 Talamine Court, Colorado Springs, Colorado 80907. A catheter introducer is a sheath used to facilCatheter pouch was mislabeled with the wrong size.accessdata.fda.gov
July 4, 200850548Not yet classifiedTerminatedTurbo Elite 0.9mm Turbo Elite (TE) RX, Model #, tip diameter 0.9mm/.038 in, 4 Fr, sterile EO. Manufactured by Spectranetics, 96 Talamine Court, Colorado Springs, CO 80907. The pouch label of the 1.4mm TE Over the Wire (OThe catheter pouch label was incorrectly labeled with the wrong size.accessdata.fda.gov
December 10, 200745949Not yet classifiedTerminatedSpectranetics Quick-Cross Support Catheters,.035in x 90cm, REF#:, Sterile, Manufactured by: Spectranetics, Colorado Springs, Colorado 80907.Mislabeling: Catheters were placed into mis-labeled inner pouches as REF Number, 135 cm--the exterior box labeling is correct as 90 cm.accessdata.fda.gov

Compare with other makers

Updated December 18, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.