Data / Medical devices / United States / Spectranetics Corp.
Spectranetics Corp.: FDA-registered device maker in Fremont, CA, United States, 1 510(k) clearance and 1 PMA approval
Spectranetics Corp. is registered with the FDA (registration 3005462046) in Fremont, CA, United States. It lists 2 device types. The FDA files 1 510(k) clearance and 1 PMA approval under its listings, the newest dated April 8, 2015. 4 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3005462046
- Address
- 5055 Brandin Court, Fremont, CA, United States, 94538
- Owner or operator
- Philips Medical Systems International BV (2939520)
- Roles
- Complaint file establishment, Manufacturer
- First device listed
- November 26, 2018
- Registered through
- 2026
- Brand names listed
- Angiosculpt OTW PTA Scoring Balloon Catheter, Angiosculpt PTCA RX Scoring Balloon Catheter
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Catheter, Percutaneous Transluminal Coronary Angioplasty (Ptca), Cutting/Scoring | NWX | 3 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Catheter, Percutaneous, Cutting/Scoring | PNO | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| April 8, 2015 | K150634 | AngioSculpt PTA Scoring Baloon Catheters | PNO | Substantially Equivalent | Spectranetrics | accessdata.fda.gov |
PMA approvals
Premarket approvals this establishment lists, with the supplements the FDA has decided since.
| Approved | PMA number | Device | Product code | Supplements | Latest decision | Source |
|---|---|---|---|---|---|---|
| January 8, 2007 | P050018 | ANGIOSCULPT SCORING BALLOON CATHETER | NWX | 32 | April 4, 2025 | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| December 7, 2018 | 84057 | Class II | Terminated | Spectranetics AngioSculpt PTCA Scoring Balloon Catheter, balloon outer diameter 2.5mm, balloon length 15mm, REF 2027-2515, Sterile, Rx. The firm name on the label is Spectranetics Corporation, Fremont, CA. | The incorrect outer carton box was used for the product. | accessdata.fda.gov |
| November 16, 2010 | 57271 | Not yet classified | Terminated | AngioScore, Inc. AngioSculpt PTA Scoring Balloon Catheter; OTW 0.018" Platform, 137 cm, 4.0 mm x 20 mm balloon size. Part (REF) number: 2076-4020 | Reports of distal bond failure which has resulted in peeling of the bond and/or detachment of the distal end of the scoring element. May result in vessel injury or embolism. | accessdata.fda.gov |
| December 4, 2009 | 54687 | Not yet classified | Terminated | AngioSculpt Percutaneous Transluminal Coronary Angioplasty (PTCA) Catheter, cutting/scoring, Easy Exchange (EX) delivery system, Manufactured by AngioScore, Fremont, CA. Catheter is for use in the treatment of hemodynami | Separations of the PTCA catheter shaft at the guide wire exit port have occurred during treatment of coronary artery stenosis. Fragments of the catheter may become lodged in coronary arteries, which resulting in serious patient outcome and require emergency coronary bypass surgery and medical intervention to remove the retained device fragments. | accessdata.fda.gov |
| November 13, 2007 | 46149 | Not yet classified | Terminated | AngioSculpt PTCA Scoring Balloon Catheter, Catalog (REF) Number: 2027-2510, size 2.5mm x 10 mm, AngioScore, Inc., Fremont, CA. | Mis-labeling: Product labeling on product pouch indicates wrong size, the correct size is on the product carton | accessdata.fda.gov |
Compare with other makers
- All makers of Catheter, Percutaneous Transluminal Coronary Angioplasty (Ptca), Cutting/Scoring
- All makers of Catheter, Percutaneous, Cutting/Scoring
Updated April 4, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.