Skip to the page

Data / Medical devices / United States / Siemens Medical Solutions Usa, Inc.

Siemens Medical Solutions Usa, Inc.: FDA-registered device maker in Ann Arbor, MI, United States, 6 510(k) clearances

Siemens Medical Solutions Usa, Inc. is registered with the FDA (registration 1836549) in Ann Arbor, MI, United States. It lists 2 device types. The FDA files 6 510(k) clearances under its listings, the newest dated April 10, 2026. 7 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1836549
FEI number
3003304172
Address
400 W. Morgan Road, Ann Arbor, MI, United States, 48108
Owner or operator
SIEMENS MEDICAL SOLUTIONS USA, INC. (9002915)
Roles
Manufacturer
First device listed
July 31, 2020
Registered through
2026
Brand names listed
Syngo Dynamics, Syngo Dynamics VA30, syngo Dynamics, syngo Dynamics VA40E, syngo Dynamics VA40F, syngo Dynamics VA41D, syngo Dynamics VA41F

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
April 10, 2026K253689syngo Dynamics (VA41F)QIHSubstantially EquivalentSiemens Healthcare GmbHaccessdata.fda.gov
April 3, 2025K242551syngo Dynamics (Version VA41D)QIHSubstantially EquivalentSiemens Healthcare GmbHaccessdata.fda.gov
November 14, 2022K222428Syngo Dynamics (Version VA40F)QIHSubstantially EquivalentSiemens Medical Solutions USA, Inc.accessdata.fda.gov
May 20, 2022K220832syngo Dynamics (Version VA40E)LLZSubstantially EquivalentSiemens Medical Solutions USA, Inc.accessdata.fda.gov
June 1, 2017K171053syngo Dynamics Version VA30LLZSubstantially EquivalentSiemens Healthcare GmbHaccessdata.fda.gov
January 16, 2013K123922SYNGO DYNAMICSLLZSubstantially EquivalentSiemens Medical Solutions USA, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
July 13, 201262581Class IITerminatedsyngo Dynamics Version 9.5If multiple uncompressed images/clips are sent to the syngo Dynamics server, around the same time, it is possible for an image from a patient to be placed in another patient's study.accessdata.fda.gov
May 10, 201158830Not yet classifiedTerminatedsyngo Dynamics Picture Archiving Communication System The software is a picture archiving and communication system intended for acceptance, transfer, display, storage, archive, and manipulation of digital medical images For systems upgraded to syngo Dynamics version 9.0, if a legacy report generated by version 3.x or earlier is opened in the version 9.0 portal, the legacy report may be deleted and replaced with a new report from the version 9.0 reporting system or a blank report.accessdata.fda.gov
March 24, 201158545Not yet classifiedTerminatedsyngo Dynamics version 9.0, Siemens Medical Solutions, USA, Inc., Ann Arbor, MI. The syngo Dynamics is a picture archiving and communications system intended for acceptance, transfer, display, storage, archiving and maniIf one or more graphs are in a table on the report, and if any of those graphs are deleted, it may lead to reports failing to save and/or marking the study as read might leave the study in an unread state or might mark the study as read but leave the report with a "Preliminary" watermark displayed.accessdata.fda.gov
July 23, 200849457Not yet classifiedTerminatedSiemens KinetDx 4.2 Workplace, Siemens Medical Solutions, Ann Arbor, MI; 10090235. Indicated for use by the physician to aid in diagnosis, and by medical professionals whenever they would require or desire access to mediIf the text is manually modified and additional phrases added as a result of worksheet interactions, some of the phrases may not populate the report.accessdata.fda.gov
February 8, 200846823Not yet classifiedTerminatedSiemens Medical Solutions, syngo Dynamics 6.0 Workplace; Picture archiving and communication systemIncorrect data: A software bug may result in a transfer of patient demographic data to a different patient's file.accessdata.fda.gov
January 31, 200737347Not yet classifiedTerminatedSiemens syngo Dynamics 5.0 Workplace. Medical image report and archive system.The cardiac calculation feature may incorrectly calculate a derived V max value (reported out lower than it should be) and certain values imported into worksheets and reports may be incorrect due to a software defect.accessdata.fda.gov
April 6, 200635043Not yet classifiedTerminatedKinetDx 4.0 Ultrasound Image Management System.The cardiologist's report comments may not be retained by the system due to a software bug.accessdata.fda.gov

Compare with other makers

Updated April 10, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.