Data / Medical devices / United States / Siemens Healthcare Diagnostics Inc.

Siemens Healthcare Diagnostics Inc.: FDA-registered device maker in Newark, DE, United States, 303 510(k) clearances and 3 PMA approvals

Siemens Healthcare Diagnostics Inc. is registered with the FDA (registration 2517506) in Newark, DE, United States. It lists 160 device types. The FDA files 303 510(k) clearances and 3 PMA approvals under its listings, the newest dated July 24, 2026. 180 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 3, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2517506
Address
500 GBC DR, PO Box 6101, Newark, DE, United States, 19714
Owner or operator
SIEMENS HEALTHCARE DIAGNOSTICS INC. (9096044)
Roles
Complaint file establishment, Contract manufacturer, Manufacturer, Manufacturer for export, Specification developer
First device listed
April 18, 1995
Registered through
2027
Brand names listed
ADVIA, ADVIA 1650 HDL CHOLESTEROL ASSAY, ADVIA Centaur NT proBNPII (PBNPII), ADVIA Centaur NT-proBNP (PBNP), ADVIA Chemistry, ADVIA Chemistry A1c_E Pretreatment Buffer Kit, ADVIA Chemistry A1c_E Reagent (2x150 Kit), ADVIA Chemistry A1c_E Reagent (4x300 Kit) and more

Devices it lists

DeviceProduct codeClassRoleSource
Acetylcholine Chloride, Specific Reagent For Pseudo CholinesteraseDLI1Manufactureraccessdata.fda.gov
Acid Phosphatase, Thymolphthale InmonophosphateCKE2Specification developeraccessdata.fda.gov
Acid, Folic, RadioimmunoassayCGN2Manufactureraccessdata.fda.gov
Acid, Lactic, Enzymatic MethodKHP1Manufacturer, Specification developeraccessdata.fda.gov
Acid, Uric, Uricase (Colorimetric)KNK1Manufactureraccessdata.fda.gov
Acid, Uric, Uricase (Oxygen Rate)JHC1Specification developeraccessdata.fda.gov
Albumin, Antigen, Antiserum, ControlDCF2Manufacturer, Specification developeraccessdata.fda.gov
Alcohol Dehydrogenase, Specific Reagent For Ethanol Enzyme MethodDIC2Manufactureraccessdata.fda.gov
Alkaline Picrate, Colorimetry, CreatinineCGX2Manufacturer, Specification developeraccessdata.fda.gov
Alpha-1-Antitrypsin, Antigen, Antiserum, ControlDEM2Manufactureraccessdata.fda.gov
Alpha-Naphthyl Phosphate, Alkaline Phosphatase Or IsoenzymesCJO2Manufactureraccessdata.fda.gov
Analyzer, Chemistry (Photometric, Discrete), For Clinical UseJJE1Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Analyzer, Chemistry, Micro, For Clinical UseJJF1Manufactureraccessdata.fda.gov
Antistreptolysin - Titer/Streptolysin O ReagentGTQ1Manufactureraccessdata.fda.gov
Assay, Glycosylated HemoglobinLCP2Manufacturer, Specification developeraccessdata.fda.gov
Assay, Porphyrin, Spectrophotometry, LithiumNDW2Manufactureraccessdata.fda.gov
Azo-Dyes, Colorimetric, Bilirubin & Its Conjugates (Urinary, Non-Quant.)JJB1Manufactureraccessdata.fda.gov
Bilirubin (Total And Unbound) In The Neonate Test SystemMQM1Manufactureraccessdata.fda.gov
Biuret (Colorimetric), Total ProteinCEK2Manufacturer, Specification developeraccessdata.fda.gov
Bromcresol Purple Dye-Binding, AlbuminCJW2Manufacturer, Specification developeraccessdata.fda.gov
Calculator/Data Processing Module, For Clinical UseJQP1Manufactureraccessdata.fda.gov
Calibrator, Multi-Analyte MixtureJIX2Complaint file establishment, Manufacturer, Manufacturer for export, Specification developeraccessdata.fda.gov
Calibrator, PrimaryJIS2Manufacturer, Specification developeraccessdata.fda.gov
Calibrator, SecondaryJIT2Complaint file establishment, Manufacturer, Manufacturer for export, Specification developeraccessdata.fda.gov
Calibrator, SurrogateJIW2Manufactureraccessdata.fda.gov
Calibrators, Drug MixtureDKB2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Calibrators, Drug SpecificDLJ2Contract manufacturer, Manufacturer, Manufacturer for export, Specification developeraccessdata.fda.gov
Cardiac C-Reactive Protein, Antigen, Antiserum, And ControlNQD2Manufactureraccessdata.fda.gov
Catalytic Methods, AmylaseJFJ2Manufacturer, Specification developeraccessdata.fda.gov
Chromatographic Separation, Cpk IsoenzymesJHT2Specification developeraccessdata.fda.gov
Colorimeter, Photometer, Spectrophotometer For Clinical UseJJQ1Manufactureraccessdata.fda.gov
Colorimetric Method, Cpk Or IsoenzymesJHY2Manufacturer, Specification developeraccessdata.fda.gov
Colorimetric Method, LipoproteinsJHM1Manufacturer, Specification developeraccessdata.fda.gov
Colorimetry, AcetaminophenLDP2Manufacturer, Specification developeraccessdata.fda.gov
Colorimetry, CholinesteraseDIH1Manufacturer, Specification developeraccessdata.fda.gov
Colorimetry, SalicylateDKJ2Manufacturer, Specification developeraccessdata.fda.gov
Complement C3, Antigen, Antiserum, ControlCZW2Manufacturer, Specification developeraccessdata.fda.gov
Complement C4, Antigen, Antiserum, ControlDBI2Manufacturer, Specification developeraccessdata.fda.gov
Cresolphthalein Complexone, CalciumCIC2Manufacturer, Specification developeraccessdata.fda.gov
CyclosporineMKW2Manufacturer, Specification developeraccessdata.fda.gov
Diazo Colorimetry, BilirubinCIG2Manufacturer, Specification developeraccessdata.fda.gov
Differential Rate Kinetic Method, Cpk Or IsoenzymesJHS2Manufacturer, Specification developeraccessdata.fda.gov
Drug Mixture Control MaterialsDIF1Complaint file establishment, Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Drug Specific Control MaterialsLAS1Manufacturer, Manufacturer for exportaccessdata.fda.gov
Electrode, Ion Specific, PotassiumCEM2Manufacturer, Specification developeraccessdata.fda.gov
Electrode, Ion Specific, SodiumJGS2Manufacturer, Specification developeraccessdata.fda.gov
Electrode, Ion-Specific, ChlorideCGZ2Manufacturer, Specification developeraccessdata.fda.gov
Enzymatic Esterase--Oxidase, CholesterolCHH1Manufacturer, Specification developeraccessdata.fda.gov
Enzymatic Method, AmmoniaJIF1Manufacturer, Specification developeraccessdata.fda.gov
Enzymatic Method, BilirubinJFM2Manufactureraccessdata.fda.gov
Enzymatic Method, CreatinineJFY2Manufacturer, Manufacturer for export, Specification developeraccessdata.fda.gov
Enzymatic Radiochemical Assay, TobramycinLDO2Contract manufacturer, Manufactureraccessdata.fda.gov
Enzymatic, Carbon-DioxideKHS2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, AmphetamineDKZ2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, BarbiturateDIS2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, BenzodiazepineJXM2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, CannabinoidsLDJ2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, CarbamazepineKLT2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, Cocaine And Cocaine MetabolitesDIO2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, DigitoxinLFM2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, DigoxinKXT2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, DiphenylhydantoinDIP2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, EthosuximideDLF2Manufactureraccessdata.fda.gov
Enzyme Immunoassay, GentamicinLCD2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, Inhibin-ANDR1Manufactureraccessdata.fda.gov
Enzyme Immunoassay, LidocaineKLR2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, MethadoneDJR2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, MethotrexateLAOUManufactureraccessdata.fda.gov
Enzyme Immunoassay, N-AcetylprocainamideLAN2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, Non-Radiolabeled, Total ThyroxineKLI2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, OpiatesDJG2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, PhencyclidineLCMUManufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, PhenobarbitalDLZ2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, PrimidoneDJD2Manufactureraccessdata.fda.gov
Enzyme Immunoassay, ProcainamideLAR2Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, PropoxypheneJXN2Manufactureraccessdata.fda.gov
Enzyme Immunoassay, QuinidineLBZ2Manufactureraccessdata.fda.gov
Enzyme Immunoassay, TheophyllineKLS2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Enzyme Immunoassay, TracrolimusMLM2Manufactureraccessdata.fda.gov
Enzyme Immunoassay, Valproic AcidLEG2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Equipment, Laboratory, General Purpose, Labeled Or Promoted For A Specific Medical UseLXG1Complaint file establishment, Specification developeraccessdata.fda.gov
Everolimus ImmunoassayOUF2Manufacturer for exportaccessdata.fda.gov
Ferritin, Antigen, Antiserum, ControlDBF2Manufactureraccessdata.fda.gov
Ferrozine (Colorimetric) Iron Binding CapacityJMO1Manufacturer, Specification developeraccessdata.fda.gov
Fibrin Split ProductsGHH2Manufactureraccessdata.fda.gov
Fibrinogen And Fibrin Split Products, Antigen, Antiserum, ControlDAP2Manufactureraccessdata.fda.gov
Flame Photometry, LithiumJIH2Manufacturer, Specification developeraccessdata.fda.gov
Fluorescent Immunoassay, TobramycinLCR2Manufactureraccessdata.fda.gov
Fluorometer, For Clinical UseKHO1Manufactureraccessdata.fda.gov
Fluorometric Method, Cpk Or IsoenzymesJHX2Manufacturer, Specification developeraccessdata.fda.gov
Gas Chromatography, MethamphetamineLAF2Manufactureraccessdata.fda.gov
Haptoglobin, Antigen, Antiserum, ControlDAD2Manufactureraccessdata.fda.gov
Hemoglobin A1c Test SystemPDJ2Manufactureraccessdata.fda.gov
Hexokinase, GlucoseCFR2Manufacturer, Specification developeraccessdata.fda.gov
High Pressure Liquid Chromatography, MethamphetamineLAG2Manufactureraccessdata.fda.gov
High Pressure Liquid Chromatography, Tricyclic Antidepressant DrugsLFI2Manufactureraccessdata.fda.gov
Immunoassay Method, Troponin SubunitMMI2Manufacturer, Specification developeraccessdata.fda.gov
Kinetic Method, Gamma-Glutamyl TranspeptidaseJQB1Manufacturer, Specification developeraccessdata.fda.gov
Kit, Test,Alpha-Fetoprotein For Testicular CancerLOJ2Manufactureraccessdata.fda.gov
Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, HdlLBS1Manufacturer, Specification developeraccessdata.fda.gov
Lipase Hydrolysis/Glycerol Kinase Enzyme, TriglyceridesCDT1Manufacturer, Specification developeraccessdata.fda.gov
Lipase-Esterase, Enzymatic, Photometric, LipaseCHI1Manufacturer, Specification developeraccessdata.fda.gov
Liquid Chromatography, AmphetamineDNI2Manufactureraccessdata.fda.gov
Multi-Analyte Controls, All Kinds (Assayed)JJY1Manufacturer, Specification developeraccessdata.fda.gov
Mycophenolic Acid Test SystemOAV2Manufacturer, Manufacturer for exportaccessdata.fda.gov
Myoglobin, Antigen, Antiserum, ControlDDR2Manufacturer, Specification developeraccessdata.fda.gov
Nad Reduction/Nadh Oxidation, Cpk Or IsoenzymesCGS2Manufacturer, Specification developeraccessdata.fda.gov
Nad Reduction/Nadh Oxidation, Lactate DehydrogenaseCFJ2Manufacturer, Specification developeraccessdata.fda.gov
Nad-Nadh, Specific Reagent For Alcohol Enzyme MethodDML2Manufactureraccessdata.fda.gov
Nadh Oxidation/Nad Reduction, Alt/SgptCKA1Manufacturer, Specification developeraccessdata.fda.gov
Nadh Oxidation/Nad Reduction, Ast/SgotCIT2Manufacturer, Specification developeraccessdata.fda.gov
Nitrophenylphosphate, Alkaline Phosphatase Or IsoenzymesCJE2Manufacturer, Specification developeraccessdata.fda.gov
Ph Rate Measurement, Carbon-DioxideJFL2Manufacturer, Specification developeraccessdata.fda.gov
Phosphomolybdate (Colorimetric), Inorganic PhosphorusCEO1Manufacturer, Specification developeraccessdata.fda.gov
Photometric Method, Iron (Non-Heme)JIY1Manufacturer, Specification developeraccessdata.fda.gov
Photometric Method, MagnesiumJGJ1Manufacturer, Specification developeraccessdata.fda.gov
Prealbumin, Antigen, Antiserum, ControlJZJ1Manufactureraccessdata.fda.gov
Prealbumin, Fitc, Antigen, Antiserum, ControlDDS1Manufactureraccessdata.fda.gov
Procalcitonin AssayPRI2Manufactureraccessdata.fda.gov
Prostate-Specific Antigen (Psa) For Management Of Prostate CancersLTJ2Manufactureraccessdata.fda.gov
Radioassay, Triiodothyronine UptakeKHQ2Manufacturer, Specification developeraccessdata.fda.gov
Radioassay, Vitamin B12CDD2Manufactureraccessdata.fda.gov
Radioimmunoassay (Two-Site Solid Phase), FerritinJMG2Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, AmikacinKLQ2Manufactureraccessdata.fda.gov
Radioimmunoassay, BarbiturateDKN2Manufactureraccessdata.fda.gov
Radioimmunoassay, Follicle-Stimulating HormoneCGJ1Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, Free ThyroxineCEC2Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, Immunoglobulins (D, E)JHR2Manufactureraccessdata.fda.gov
Radioimmunoassay, Immunoglobulins (G, A, M)CFQ2Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, Lsd (125-I)DLB2Manufactureraccessdata.fda.gov
Radioimmunoassay, Luteinizing HormoneCEP1Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, MethaqualoneKXS2Manufactureraccessdata.fda.gov
Radioimmunoassay, Parathyroid HormoneCEW2Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, ProgesteroneJLS1Manufactureraccessdata.fda.gov
Radioimmunoassay, Prolactin (Lactogen)CFT1Complaint file establishment, Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, Testosterones And DihydrotestosteroneCDZ1Manufactureraccessdata.fda.gov
Radioimmunoassay, Thyroid-Stimulating HormoneJLW2Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, TobramycinKLB2Manufacturer, Specification developeraccessdata.fda.gov
Radioimmunoassay, Total TriiodothyronineCDP2Manufactureraccessdata.fda.gov
Radioimmunoassay, Tricyclic Antidepressant DrugsLFG2Manufactureraccessdata.fda.gov
Radioimmunoassay, VancomycinLEH2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Reagents, Test, TetrahydrocannabinolDKE2Manufactureraccessdata.fda.gov
Sirolimus Test SystemNRP2Manufactureraccessdata.fda.gov
System, Test, C-Reactive ProteinDCN2Manufacturer, Specification developeraccessdata.fda.gov
System, Test, Carbohydrate Antigen (Ca19-9), For Monitoring And Management Of Pancreatic CancerNIG2Manufactureraccessdata.fda.gov
System, Test, Carcinoembryonic AntigenDHX2Manufactureraccessdata.fda.gov
System, Test, Human Chorionic GonadotropinDHA2Manufacturer, Specification developeraccessdata.fda.gov
System, Test, Immunological, Antigen, TumorMOI2Manufactureraccessdata.fda.gov
System, Test, Low Density, LipoproteinMRR1Manufacturer, Specification developeraccessdata.fda.gov
System, Test, Radioallergosorbent (Rast) ImmunologicalDHB2Manufactureraccessdata.fda.gov
System, Test, Vitamin DMRG2Manufactureraccessdata.fda.gov
Test Reagents For Ethyl AlcoholDMJ2Specification developeraccessdata.fda.gov
Test, Epithelial Ovarian Tumor-Associated Antigen (Ca125)LTK2Manufactureraccessdata.fda.gov
Test, Follicle Stimulating Hormone (Fsh), Over The CounterNGA1Manufactureraccessdata.fda.gov
Test, Natriuretic PeptideNBC2Manufacturer, Manufacturer for export, Specification developeraccessdata.fda.gov
Test, Prostate Specific Antigen, Free, (Noncomplexed) To Distinguish Prostate Cancer From Benign ConditionsMTG3Manufactureraccessdata.fda.gov
Total, Prostate Specific Antigen (Noncomplexed & Complexed) For Detection Of Prostate CancerMTF3Manufactureraccessdata.fda.gov
Transferrin, Antigen, Antiserum, ControlDDG2Manufacturer, Specification developeraccessdata.fda.gov
U.V. Spectrometry, Tricyclic Antidepressant DrugsLFH2Manufactureraccessdata.fda.gov
Urease And Glutamic Dehydrogenase, Urea NitrogenCDQ2Manufacturer, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance. Newest 100 of 303.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
July 24, 2026K261364Atellica CH Acetaminophen 2 (ACTM)LDPSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
February 27, 2026K251998Atellica CH Diazo Total Bilirubin (D_TBil)CIGSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
April 25, 2025K243570Dimension LOCI Thyroid Stimulating Hormone Flex reagent cartridge (TSHL); Dimension LOCI Free Thyroxine Flex reagent cartridge (FT4L)JLWSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
December 4, 2024K242685Atellica® CH Creatinine_3 (Crea3)CGXSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
July 26, 2024K241800Atellica® CH HDL Cholesterol (HDLC)& Atellica® CH LDL Cholesterol (LDLC)MRRSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
January 18, 2024K233242Atellica® CH High Sensitivity C-Reactive Protein 2 (hCRP2)NQDSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
September 24, 2023K220265ADVIA Centaur® NT-proBNPII (PBNPII)NBCSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
August 8, 2023K222439Atellica® CH Phencyclidine (Pcp), Atellica® CH Vancomycin (Vanc)LEHSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
July 25, 2023K222438A-LYTE® Integrated Multisensor (IMT Na K Cl)JGSSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
July 25, 2023K221605Emit® II Plus Buprenorphine AssayDJGSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
July 13, 2023K222116Atellica® CI Analyzer, Atellica® IMThyroid Stimulating Hormone 3-Ultra (TSH3-UL), Atellica® CH Albumin BCP (AlbP)JLWSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
June 12, 2023K223078Atellica® CH Diazo Direct Bilirubin (D_DBil)CIGSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
March 17, 2023K221119RCRP Flex reagent cartridgeDCNSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
August 26, 2022K220262Dimension EXL LOCI BRAHMS Procalcitonin (PCT)PRISubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
November 24, 2021K212223Atellica CH Enzymatic Creatinine_3 (ECre3)JFYSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
July 2, 2021K200256ADVIA Chemistry Enzymatic Hemoglobin Ale (Alc_E) AssayPDJSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
May 17, 2019K190675Dimension EXL High-Sensitivity Troponin I (TNIH) AssayMMISubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
March 4, 2019K182225Dimension Vista High-Sensitivity Troponin I (TNIH) AssayMMISubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
July 13, 2018K173909Dimension Hemoglobin A1c AssayPDJSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
October 25, 2017K170293Emit II Plus Cocaine Metabolite AssayDIOSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
October 18, 2017K172910Emit II Plus Oxycodone AssayDJGSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
March 16, 2017K162298LOCI Total Vitamin D Total Assay, LOCI VITD CALMRGSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
March 9, 2017K170065ADVIA® Chemistry Total Bilirubin_2 (TBIL_2)JFMSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
February 11, 2016K151529Dimension Vista LOCI Total Testosterone Flex reagent cartridge, Dimension Vista Testosterone CalibratorCDZSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
December 18, 2015K153365ADVIA Chemistry Enzyme 1 Calibrator, ADVIA Chemistry Enzyme 2 CalibratorJIXSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
December 11, 2015K151767Trinidad CH system, TD-LYTE Integrated Multisensor (Na, K, CI), TD-LYTE IMT Standard A, TD-LYTE IMT Standard B + Salt Bridge, Trinidad CH Albumin BCP reagent (Alb_P), Trinidad CH Albumin BCP CalibratorJGSSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
November 20, 2015K151792Trinidad IM Thyroid Stimulating Hormone (TSH) Assay, Trinidad IM TSH Calibrators, Trinidad Immunoassay (IM) SystemJLWSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
November 4, 2015K150168Dimension Tacrolimus Flex® Reagent Cartridge (TAC), Dimension Tacrolimus Calibrator (TAC CAL)MLMSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
October 23, 2015K150606Emit II Plus Buprenorphine Assay, Emit II Plus Specialty Drug Calibrator/Control Level 1, Level 2 Level 3, Level 4, Emit II Plus Specialty Drug Control Negative, Emit II Plus Specialty Drug Control PositiveDJGSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
September 18, 2015K143720Dimension Vista MMB AssayJHYSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
June 15, 2015K140790Dimension Vista Chemistry 1 Calibrator (CHEM 1 CAL), Dimension Vista Magnesium Flex reagent cartridge (MG)JIXSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
November 26, 2014K140859DIMENSION VISTA FREE THYROXINE FLEX REAGENT CARTRIDGE, FT4, DIMENSION VISTA THYROID STIMULATING HORMONE FLEX REAGENTCECSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
January 27, 2014K132638DIMENSION CREATININE (CRE2) FLEX REAGENT CARTRIDGECGXSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
January 24, 2014K133728DIMENSION VISTA CREATININE (CRE2) FLEX REAGENT CARTRIDGECGXSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
January 2, 2014K133512LOCI VITAMIN B12 (VB12) FLEX REAGENT CARTRIDGE, LOCI ANEMIA CALIBRATOR (ANEM CAL)CDDSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
October 16, 2013K132664ADVIA CHEMISTRY ALBUMIN BCP REAGENT (ALBP), ADVIA CHEMISTRY ALBUMIN BCP CALIBRATORCJWSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
April 5, 2013K130698DIMENSION VISTA PROGESTERONE CALIBRATOR (PROG CAL)JITSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
March 22, 2013K130276DIMENSION EXL WITH LM SYSTEMJJESubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
March 7, 2013K123677DIMENSION VISTA; AMMONIA FLEX REAGENT CARTRIDGE (AMM), CHEMISTRY 3 CALIBRATOR (CHEM 3 CAL)JIFSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
February 15, 2013K123321DIMENSION CHEMISTRY III CALIBRATORYJIXSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
February 15, 2013K123320DIMENSION AMMONIA FLEX REAGENT CARTRIDGEJIFSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
November 30, 2012K121994DIMENSION VISTA VITAMIN B12 (VB12) FLEX REAGENT CARTRIDGE, DIMENSION VISTA LOCI 4 CALIBRATORCDDSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
August 28, 2012K122323DIMENSION VISTA ALKALINE PHOSPHATASE (ALPI) FLEX REAGENT CARTRIDGE DIMENSION VISTA ALKALINE PHOSPHATASE CALIBRATOR (ALPICJOSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
July 23, 2012K121907DIMENSION ALKALINE PHOSPHATASE FLEX REAGENT CARTRIDGE, DIMENSION ALKALINE PHOSPHATASE CALIBRATORCJOSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
November 22, 2011K112999DIMENSION CLINICAL CHEMISTRY SYSTEMJJESubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
November 4, 2011K112142DIMENSION VISTA LITHIUM FLEX REAGENT CARTRIDGENDWSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
October 7, 2011K102772DIMENSION MYCOPHENOLIC ACID (MPAT) FLEX REAGENT CARTRIDGE, DIMENSION MYCOPHENOLIC ACID CALIBRATOR (MPAT CAL)OAVSubstantially EquivalentSiemens Heatlhcare Diagnostics, Inc.accessdata.fda.gov
May 16, 2011K110303STRATUS CS ACUTE CARE D-DIMERDAPSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
April 18, 2011K100344DIMENSION VISTA LOCI CA 15-3 FLEX REAGENT CARTRIDGE, DIMENSION VISTA LOCI 7 CALIBRATOR, MODELS: K6456 AND KC605MOISubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
April 12, 2011K100321DIMENSION VISTA LOCI CA 125 FLEX REAGENT CARTRIDGE,AND DIMENSIONS VISTA LOCI 6 CAL, MODEL#'S K6455, AND KC604LTKSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
April 6, 2011K100375DIMENSION VISTA LOCI CA 19-9 FLEX REAGENT CARTRIDGE, AND DIMENSION LOCI7 CALIBRATOR WITH MODEL(S) K6457, AND KC604NIGSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
March 18, 2011K102779EMIT II PLUS6-ACETYLMORPHINE ASSAY; EMIT II PLUS 6-AM/ ECSTASY CALIBRATOR/ CONTROL LEVEL 1; EMIT II PLUS 6-AM / ECTASY CDJGSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
February 16, 2011K103836ENZYME II CALIBRATORJITSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
January 25, 2011K103612DIMENSION VISA ENZ 2 CALJIXSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
December 17, 2010K103360DIMENSION VISTA DIGITOXIN CALIBRATOR - DGTX CALJITSubstantially EquivalentSiemens Corp.accessdata.fda.gov
August 2, 2010K100200ADVIA CHEMISTRY ACETAMINOPHEN REAGENT, MODEL REF 07989138LDPSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
July 9, 2010K101460LOCI 8 CALIBRATOR, MODEL KC 646JIXSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
May 19, 2010K093939ADVIA CHEMISTRY SALICYLATE REAGENTDKJSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
May 10, 2010K100289ADVIA CHEMISTRY SYSTEMS CARBON DIOXIDE LIQUID (C02_L) ASSAY, MODEL REF 07987100, 07506781KHSSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
May 5, 2010K100778DIMENSION EXL LOCI THYROID CALIBRATOR, MODEL RC 610AJIXSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
April 7, 2010K093441DIMENSION VISTA LOCI DIGOXIN FLEX REAGENT CARTRIDGE (DIGXN), MODEL K6435KXTSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
February 12, 2010K093631B12 REAGENT CARTRIDGE AND FOL FLEX REAGENT CARTRIDGE, MODEL RF642 AND RF644CDDSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
May 22, 2009K090330DIMENSION VISTA ENZYMATIC CREATININE FLEX REAGENT CARTRIDGE, AND ENZYMATIC CREATININE CALIBRATOR, MODELS K1270, KC270JFYSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
April 27, 2009K090236DIMENSION VISTA AFP FLEX REAGENT CARTRIDGE, MODEL 6454LOJSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
March 30, 2009K083487EMIT 2000 SIROLIMUS ASSAY, EMIT 2000 SIRO/TACRO SAMPLE PRETREATMENT REAGENT, AND EMIT 200 SIROLIMUS CALIBRATORNRPSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
February 27, 2009K083465DIMENSION VISTA CREATINE KINASE FLEX REAGENT CARTRIDGE AND DIMENSION VISTA CREATINE KINASE MB FLEX REAGENT CARTRIDGECGSSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
February 27, 2009K083462DIMENSION VISTA SYSTEM ENZYME 5 CALIBRATOR, MODEL KC350JITSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
February 26, 2009K082638ADVIA CENTAUR SYSTEM WITH STREAMLAB ANALYTICAL WORKCELLKLISubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
February 20, 2009K083579DIMENSION VISTA SYSTEM ENZYME 6 CALIBRATOR, MODEL KC360JIXSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
January 8, 2009K081895ADVIA CHEMISTRY HEMOGLOBIN A1C, ADVIA CHEMISTRY A1C CALIBRATORSLCPSubstantially EquivalentSiemens Medical Solutions Diagnosticsaccessdata.fda.gov
October 30, 2008K081857DIMENSION SIRO FLEX REAGENT CARTRIDGE AND DIMENSION SIROLIMUS CALBIRATOR, MODELS DR 306, DC 306NRPSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
October 10, 2008K082680LOCI N-TERMINAL PRO-BRAIN NATRIURETIC PEPTIDE CALIBRATOR, MODEL RC623JITSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
September 22, 2008K082645DIMENSION EXL N-TERNMIAL PRO-BRAIN NATRIURETIC PEPTIDE (NTP) FLEX REAGENT CARTRIDGE, MODEL RF623NBCSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
September 10, 2008K081789DIMENSION CLINICAL CHEMISTRY SYSTEM ENZYME I CALIBRATORJITSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
August 29, 2008K081731DIMENSION CKI FLEX REAGENT CARTRIDGE, DIMENSION MBI FLEX REAGENT CARTRIDGE, AND CKI/MBI CALIBRATOR, MODELS DF38, DF32CGSSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
August 4, 2008K081319DIMENSION CLINICAL CHEMISTRY SYSTEM LIPASE CALIBRATOR, MODEL DC56JITSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
July 7, 2008K081683LOCI CARDIAC TROPONIN I CALIBRATOR, MODEL RC621JITSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
July 3, 2008K081643DIMENSION TNI FLEX REAGENT CARTRIDGE, AND CTNI SAMPLE DILUENT WITH MODELS, RF621, KD692MMISubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
July 2, 2008K081300DIMENSION VISTA HDLC FLEX REAGENT CARTRIDGEJHMSubstantially EquivalentSiemens Healthcare Diagnosticsaccessdata.fda.gov
June 25, 2008K071603DIMENSION VISTA CARCINOEMBRYONIC ANTIGEN FLEX REAGENT CARTRIDGE (CEA)DHXSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
May 16, 2008K080578DIMENSION VISTA N-TERMINAL PRO-BRAIN NATRIURETIC PEPTIDE (PBNP) FLEX REAGENT CARTRIDGE (K6423A), DIMENSION VISTANBCSubstantially EquivalentSiemens Healthcare Diagnostics, Inc.accessdata.fda.gov
February 21, 2008K073072DIMENSION AHDL FLEX REAGENT CARTRIDGE, MODEL: DF48BJHMSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
January 3, 2008K073055DIMENSION ENZYMATIC CREATININE FLEX REAGENT CARTRIDGE WITH MODEL DF270JFYSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
December 12, 2007K072717DIMENSION VISTA SYSTEM BILIRUBIN CALIBRATOR, MODEL KC210JITSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
December 7, 2007K063845ADVIA CHEMISTRY TOTAL BILIRUBIN_2JFMSubstantially EquivalentBayer Healthcare, LLCaccessdata.fda.gov
November 13, 2007K071224DIMENSION VISTA VITAMIN B12 AND FOLATE FLEX REAGENT CARTRIDGES AND LOCI 4 CALIBRATORCDDSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
August 24, 2007K071811ETOH FLEX REAGENT CARTRIDGE (DF22)DICSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
August 17, 2007K071834STRATUS CS ACUTE CARE NT-PROBNP TESTPAK, MODEL CPBNPMNBCSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
August 4, 2007K071767DIMENSIONS PBNP FLEX REAGENT CARTRIDGE, MODEL RF423ANBCSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
August 3, 2007K070727ADVIA CHEMISTRY ENZYMATIC CREATININE_2JFYSubstantially EquivalentSiemens Medical Solutions Diagnosticsaccessdata.fda.gov
June 13, 2007K070853DIMENSION VISTA ETOH FLEX REAGENT CARTRIDGE, MODEL K5022DICSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
April 30, 2007K070552DIMENSION VISTA FERRITIN FLEX REAGENT CARTRIDGE (FERR)JITSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
March 23, 2007K063356STRATUS CS ACUTE CARE D-DIMER TESTPAK, DILPAK, CALPAKDAPSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
February 23, 2007K063754DIMENSION VISTA (TM) BHCG FLEX(R) REAGENT CARTRIDGE, AND BHCG CALIBRATOR, MODEL# K6430,KC632DHASubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
January 11, 2007K063610DIMENSION VISTA A1AT FLEX REAGENT CARTRIDGE AND PROTEIN 1 CALIBRATOR AND CONTROL MEDIUM AND HIGHDEMSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
December 26, 2006K062924STRATUS CS ACUTE CARE CARDIOPHASE HSCRP TESTPAKNQDSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
September 14, 2006K062182DIMENSION VISTA SYSTEM ECSTASY CALIBRATOR, MODEL KC520DLJSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
September 14, 2006K062162DIMENSION VISTA SYSTEM DRUGS OF ABUSE CALIBRATOR (UDAT CAL - KC510)DKBSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
September 6, 2006K062034DIMENSION VISTA SYSTEM DRUG 1 CALIBRATOR (DRUG 1 CAL - KC410)JIXSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov
August 29, 2006K061839DIMENSION VISTA DBIL FLEX REAGENT CARTRIDGE, MODEL K2125CIGSubstantially EquivalentDade Behring, Inc.accessdata.fda.gov

PMA approvals

Premarket approvals this establishment lists, with the supplements the FDA has decided since.

ApprovedPMA numberDeviceProduct codeSupplementsLatest decisionSource
January 24, 2003P020027DIMENSION FPSA FLEX REAGENT CARTRIDGE AND DIMENSION T/F PSA CALIBRATOR FOR DIMENSION RXL AND XPAND SYSTEMSMTG41May 22, 2025accessdata.fda.gov
July 5, 2001P000021DIMENSION(R) RXL PSA FLEX(R) REAGENT CARTRIDGELTJ45May 22, 2025accessdata.fda.gov
October 2, 1996P920031EMIT 2000 CYCLOSPORINE SPECIFIC ASSAYMKW3July 24, 2002accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI. Newest 100 of 180.

InitiatedEventClassStatusProductReasonSource
June 26, 202699379Class IIIOngoingSyva Emit Disopyramide Assay Enzyme Immunoassay, Lidocaine SMN 10445370 Catalog No 6N319ULOut-of-specification sodium azide concentration in Syva Emit Disopyramide Enzyme Immunoassay Calibrator Lot U1. While the assay results were not impacted, the overall health risk to lab technicians due to this issue is low, as exposure is limited by small volumes and a 0.2% post-reconstitution sodium azide concentration, with the worst outcome being mild skiaccessdata.fda.gov
May 7, 202698985Class IIOngoingSiemens Dimension Tacrolimus Flex Reagent Cartridge (TAC), REF DF207, SMN 10700795; enzyme immunoassayA potential positive bias in quality control (QC) and patient sample results in three lots of the Dimension Tacrolimus (TAC) Flex reagent cartridge.accessdata.fda.gov
March 18, 202698666Class IIOngoingDimension Creatinine Flex reagent cartridge. Material Number: 10872079.Siemens Healthcare Diagnostics is recalling certain lots of Dimension Creatinine Flex reagent cartridge (Dimension CRE2) because a potential imprecision in the Dimension CRE2 quality control (QC) and patient sample results using lot numbers GA6307 and BA7005 on the Dimension System. This imprecision may lead to erroneously decreased or increased creatinine paccessdata.fda.gov
November 12, 202495751Class IIOngoingMagnesium Flex reagent cartridge, 360 tests, Catalog Number: K3057; Siemens Material Number (SMN): 10445158Siemens Healthcare Diagnostics is recalling two lots of their Dimension Vista Total Magnesium (MG) Flex Reagent Cartridges (lots 24057BB and 24064BC) due to the potential for falsely low measurements of magnesium in plasma. Because the error is intermittent, existing quality control procedures may not recognize that a patients results are incorrect, and the accessdata.fda.gov
July 30, 202495116Class IIOngoingDimension Vista Total Bilirubin (TBIL) Flex Reagent Cartridge; Siemens Material Number (SMN): 10445146During manufacturing, the last three tests from the 160 test flex of lot 23206BA (wells 8 or 10) were processed on the Dimension Vista platform. There was an issue with the filling line which led to some wells to underfill in lot 23206BA. Calibrator, quality control (QC) and patient results could have been impacted.accessdata.fda.gov
May 16, 202392461Class IIOngoingAptio Automation Storage and Retrieval Module (SRM)A firmware error may lead to an incorrect association of test result(s) to a sample ID and therefore to an incorrect patient result. The mis-association of test results, or a delay in testing, may occur when all the conditions listed below occur within a few milliseconds timeframe of each other: - The SRM module is releasing a sample tube (Tube A) just placeaccessdata.fda.gov
August 24, 202290872Class IIOngoingDimension Vista High Density Lipoprotein Cholesterol (HDLC) Flex reagent cartridge, IVD Siemens Material Number (SMN): 10464340 Catalog Number: K3048ADimension Vista High Density Lipoprotein Cholesterol (HDLC) Potential for Erroneous Result. If an HDLC QC or patient result is obtained without an Abnormal Reaction [E145]: flag, a falsely depressed or elevated result ranging from -90% to 133% may be observed.accessdata.fda.gov
August 17, 202290825Class IIOngoingDimension Magnesium (MG) Flex reagent cartridge Siemens Material Number (SMN)/REF (Catalog Number):10444963/DF57Dimension Magnesium (MG) Flex reagent cartridge lots may exhibit imprecision for Quality Control (QC) and produce Abnormal Reaction flags. The issue is not always detected by QC and erroneous results may be produced in the absence of an Abnormal Reaction flag. Based on customer data, imprecision leading to erroneous, unflagged patient results with a bias of accessdata.fda.gov
July 18, 202290669Class IIOngoingDimension Vista LOCI CA 15-3 Flex reagent cartridge. In Vitro Diagnostic for the quantitative measurement of CA 15-3. Siemens Material Number (SMN)/Ref Catalog Number : 10464344/K6456Negative bias with patient samples. The mean patient sample bias range from -26% to -33%,potential risk of delay in appropriate treatment and management decisions.accessdata.fda.gov
May 18, 202290387Class IITerminatedDimension LTNI -In vitro diagnostic test intended to quantitively measure cardiac troponin-I levels in human serum and heparinized plasma to aid in the diagnosis of myocardial infarction. Siemens Material Number (SMN)/REPositive bias with Lithium Heparin plasma samples from individuals that are expected to be below the 99th percentile of 0.07 ng/mL [0.07 g/L], may lead to inappropriate intervention for myocardial infarctionaccessdata.fda.gov
January 28, 202289697Class IIOngoingSiemens Dimension Vista Magnesium Flex reagent cartridge (MG) Material # 10445158, Catalog # K3057 used in the Dimension Vista System. The Dimension Vista Magnesium Flex Reagent (MG) method is an In vitro diagnostic testDimension Vista Magnesium Flex reagent cartridge lots exhibiting imprecision and intermittent Abnormal Assay flags. When this issue occurs, there is a potential for QC failures or erroneous patient results which may lead to repeat and follow-up testing.accessdata.fda.gov
October 15, 202189008Class IITerminatedDimension Vista 1500 In-vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measuring spectral intensities to determine a variety of analytes in human body fIncorrect Default Hemolysis, Icterus or Lipemia (HIL) Index for Five Dimension Vista Assaysaccessdata.fda.gov
October 6, 202188865Class IIOngoingAptio Automation Interface Module to ADVIA Centaur XP/XPT. Aptio by Siemens Centaur Interface Firmware (FW) CENa_3-1-0-1 and lower. SMN 10703038The Aptio Automation Firmware for the ADVIA Centaur XP/XPT Interface Module may lead, in some cases, to an incorrect association of test results to sample ID. Incorrect association of test results could impact clinical interpretations and clinical decisions.accessdata.fda.gov
February 3, 202187319Class IIOngoingDimension Vista HDLC - colorimetric method, lipoproteins - Product Usage: used as an aid in the diagnosis of lipid disorders (such as diabetes mellitus), various liver and renal diseases, and in the assessment of risk foSiemens Healthcare Diagnostics Inc. has confirmed the potential for erroneous results due to discolored reagent observed in some wells 5 and 6 of Dimension Vista High Density Lipoprotein Cholesterol (HDLC) Flex reagent cartridges lot 20062BA.accessdata.fda.gov
August 25, 202086430Class IITerminatedSiemens Dimension Vista Akaline Phosphatase (ALPI) Flex reagent cartridge - In vitro diagnostic test for the quantitative measurement of alkaline phosphatase in human serum and plasma Catalog Number: K2115, SMN# 10642444Low outlier resultsgenerated with Alkaline Phosphatase (ALPI) Flex reagent cartridge.The maximum difference observed with a patient sample was approximately -27% at a concentration of 129 U/L (2.15 ukat/L). The low outlier results are generated from the last five (5) tests of the wellaccessdata.fda.gov
August 19, 202086374Class IITerminatedDimension LOCI High Sensitivity Troponin I (TNIH) Flex reagent cartridge-IVD-In vitro diagnostic use in the quantitative measurement of cardiac troponin I in human plasma Catalog Number: RF627, SMN# 10471068Positive bias across the Analytical Measurement Range of the TNIH assay compared to an unaffected control lot. The average bias observed for patient samples using lots EB0255 and EA0178 of the Dimension EXL Troponin compared with a control lot was +25%. A maximum bias of +34% in patient samples around the 99th percentile observedaccessdata.fda.gov
July 24, 202086151Class IITerminatedDimension Vista High Sensitivity Troponin I (TNIH) Flex reagent cartridge-IVD-In vitro diagnostic use in the quantitative measurement of cardiac troponin I in human plasma Catalog Number K6427, SMN# 104471067Dimension Vista High Sensitivity Troponin I (TNIH) may exhibit a negative bias with patient samplesaccessdata.fda.gov
June 30, 202085980Class IITerminatedDCA Vantage Handheld Barcode Scanner - Zebra Model - Model # DS4308 - HC0015BZZWW external accessory to DCA Vantage Analyzer USIf DCA Vantage Analyzer is configured to run Code 39 with check digit, the scanner is not confirming the integrity of read barcode data using the check digit. Also, if DCA Vantage Analyzer is configured to run Code 39 with check digit and an operator erroneously scans a Code 39 barcode without a check digit, the scanner incorrectly sends the code and the lasaccessdata.fda.gov
May 4, 202085602Class IITerminatedADVIA Chemistry Fructosamine Reagent (FRUC), Siemens Material Number 10361941, UDI Number 00630414558073 - Product Usage: use in the quantitative measurement of glycated protein (fructosamine) in human serum and plasma fThe presence of N-acetyl-p-benzoquinone imine (NAPQI), a metabolite of acetaminophen, may cause interference in certain chemistry assays when testing patient samples.accessdata.fda.gov
February 13, 202085037Class IITerminatedAtellica CH Direct Bilirubin_2 assay In vitro Diagnostic for the determination of direct bilirubin SMN: 11097532 - Product Usage: ADVIA DBIL_ 2 is for in vitro diagnostic use in the quantitative determination of direct bBilirubin assays may exhibit a positive bias with patients on eltrombopag therapyaccessdata.fda.gov
July 15, 201983384Class IITerminatedDimension Ferritin (FERR) Flex reagent cartridge DM FERR Product Usage: The FERR Flex reagent cartridge is intended to be used on the Dimension RxL clinical chemistry system to quantitatively measure ferritin in human seNegative Bias with Lot EA9227.accessdata.fda.gov
May 3, 201982980Class IITerminatedADVIA Chemistry Creatine Kinase (CK_L) reagent, Product Code 10729780, UDI Number: 00630414008943 - Product Usage: The ADVIA Chemistry Creatine Kinase (CK_L) assay is for in vitro diagnostic use in the quantitative deterA steady upward trend in blank (u) absorbance was observedaccessdata.fda.gov
December 12, 201881955Class IITerminatedDimension Vista 500, Analyzer, chemistry Model no. 10284473When the Millipore Water Purification Module Progard Pretreatment Packs are used with Dimension Vista Triglyceride assay, patient and QC triglyceride results may be erroneously elevated as a result of contamination.accessdata.fda.gov
October 16, 201881478Class IITerminatedDimension Vista 500, model no. 10284473 an in vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measuring spectral intensities to determine a variety of anSiemens Healthcare Diagnostics has identified an issue with Dimension Vista software v.3.7 and v.3.8.1 that may result in aliquot well contamination. If a test is cancelled by the operator while the instrument is aliquotting the sample, the Dimension Vista instrument may continue to deliver the cancelled sample or vial contents to the aliquot well(s). Futureaccessdata.fda.gov
October 11, 201881433Class IITerminatedDimension Vista Lactate Dehydrogenase (LDI) Flex reagent cartridge, an in vitro diagnostic test for the quantitative measurement of lactate dehydrogenase in human serum and plasma on the Dimension Vista System.Cat. No. KSiemens Healthcare Diagnostics has confirmed that Dimension Vista Lactate Dehydrogenase (LDI) may exhibit an erroneously elevated result when the preceding assay in the reaction cuvette is Lactic Acid (LA). The magnitude of the elevation may be variable. Both quality control and patient samples may be impacted. Incomplete removal of residual lactate dehydrogaccessdata.fda.gov
September 28, 201881278Class IITerminatedDimension Thermal Chamber Motor Cable located in the following models: Model/UDI Number: Dimension EXL 200 00630414593579; Dimension EXL with LM 00630414593500; Dimension EXL with LM with STM 00630414593593; Dimension RxThermal chamber motors have electrical cables with single insulation rather than the required double insulation. There is no exposed current due to the single insulation that could result in a potential electrical shockaccessdata.fda.gov
September 7, 201881237Class IITerminatedDimension Lipase Flex Reagent Cartridge, Model Number 10460277 Product Usage: Dimension - The LIPL method is an in vitro diagnostic test for the quantitative measurement of lipase in human serum and plasma on the DimensiThere is lot to lot variability for QC and patient results when using the identified reagent cartridge lots.accessdata.fda.gov
July 16, 201880516Class IITerminatedRAPIDPoint 405 Blood Gas Analyzer; 10282093, 10310464, 10314817, 10317193, 10318999, 10320055, 10321238, 10322347, 10328278, 10328302, 10336784 Device is point-of-care system for comprehensive lab-quality testing to patiTherapeutic levels (1mg/mL and 2mg/mL) of Hydroxocobalamin may interfere with tHb and some of the CO-Ox fractions that are reported on the RAPIDPoint and RAPIDLab Blood Gas systems indicated. This may cause lower than expected values for carboxyhemoglobin (fCOHb) and methemoglobin (fMetHb). A negative interference with fCOHb has the potential to alter the meaccessdata.fda.gov
April 19, 201880009Class IITerminatedDimension Gentamicin Flex reagent cartridge, DM GENT, gentamicin enzyme immunoassay, Lot numbers affected are EB8115, BB8159, and FB8275.The affected lots may exhibit inaccuracy for Quality Control and patient samples at the low end of the Analytical Measurement Range. The bias is due to the calibration curve not showing separation between the Level 1 and Level 2 calibrators.accessdata.fda.gov
March 21, 201879784Class IITerminatedDimension Vista CTNI Sample Diluent, KD692, SMN# 10445205The diluent may have an incomplete slit on the septum in the cap of the vial. A diluent cap with a defective septum has the potential to cause erroneously elevated results if a sample is autodiluted onboard the system, due to a reduced volume of diluent being pipetted from the vial.accessdata.fda.gov
January 30, 201879593Class IITerminatedDimension Vista Calcium Flex reagent cartridge, Dimension Vista CA, K1023, SMN # 10445160 The CA method is an in vitro diagnostic test for the quantitative measurement of calcium in human serum, plasma, and urine on the May produce erroneously low results from specific well sets.accessdata.fda.gov
December 14, 201779468Class IITerminatedDimension Lipase Flex Reagent Cartridge - ( Lipase-esterase, enzymatic, photometric, lipase)Calibration failure - confirmed a positive bias with LIPL lot FB8109 when compared to other Dimension LIPL lots. Lot FB8109 is not meeting Siemens internal specifications for lot-to-lot limits.accessdata.fda.gov
November 27, 201779413Class IITerminatedSyva EMIT 2000 Theophylline Product Usage: The Syva Emit 2000 Theophylline Assay is a homogeneous enzyme immunoassay intended for use in the quantitative analysis of theophylline in human serum or plasma.Lot J1 of the Syva EMIT 2000 Theophylline Assay, when run on a Beckman AU Clinical Chemistry System, may exhibit increased imprecision for commercially available controls and for patient samples.accessdata.fda.gov
November 9, 201779412Class IITerminatedDimension Vista System LOCI 8 CALIBRATOR The LOCI 8 Calibrator is an in vitro diagnostic product for the calibration of follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin (PRL), and estradiol (E2) meAn increase in the number of failed calibration events or negative bias with Quality Control (QC) and patient samples when using Dimension Vista LOCI 8 Calibrator lot 7CD076 to calibrate Estradiol (E2) Assay.accessdata.fda.gov
May 23, 201777381Class IITerminatedDimension Vista Protein 1 Calibrator, PROT 1 CAL, Siemens Material Number (SMN) 10465664 (US) and 10469516 (OUS), Product Code KC710U (US) and KC710 (OUS); IVDComplaint of high amount of ceruloplasmin patient results below the reference range (< 20 mg/dL [0.2 g/L]. PROT1 CAL and corresponding PROT1 CON L, M, and H are inaccurately assigned for ceruloplasmin (CER).accessdata.fda.gov
March 21, 201776915Class IITerminatedDimension Troponin 1 (TNI) Flex reagent cartridgeThe concentrations for Biotin listed in the Non-Interfering Substances section of the current Dimension and Dimension Vistat Instructions for Use (IFU) for Dimension TNI, Dimension Vista DIGXN, E2, FERR, PRL, and TSH have incorrect units, and incorrectly state the level at which biotin does not interfere.accessdata.fda.gov
March 3, 201776690Class IITerminatedDimension Vista 500 Intelligent Lab System and Dimension Vista 1500 Intelligent Lab System, analyzer, chemistry (photometric, discrete), for clinical use Product Usage: The Siemens Healthcare Diagnostics Dimension Vista Siemens Healthcare Diagnostics has confirmed that in isolated cases when ECREA is processed immediately after the weekly automated Acid Clean routine during Probe Test, there is the remote potential for an elevation of greater than 15 percent in the ECREA result.accessdata.fda.gov
February 23, 201776695Class IIITerminatedADVIA Chemistry Enzyme 2 Calibrator, multi-analyte mixture Product Usage: Assays included in Enzyme 2 Calibrator: AST, AST_c ALT, ALT_c, ALTP5P, ALTP_c, ASTP5P and ASTP_cSiemens Healthcare Diagnostics has confirmed a positive bias of up to 41% in quality control and patient results for Aspartate Aminotransferase (AST) and Aspartate Aminotransferase concentrated (AST_c) assays following calibration with Advia Chemistry Enzyme 2 Calibrator lots 6JD079 and 6MD042.accessdata.fda.gov
December 16, 201676152Class IITerminatedDimension Ammonia Flex reagent cartridge / AMM Dimension: The AMM method is an in vitro diagnostic test for the quantitative measurement of ammonia in human plasma on the Dimension clinical chemistry system. Ammonia measSiemens Healthcare Diagnostics has determined that Dimension AMM (DF119) flex reagent cartridge lots EB7180, FB7152, BA7194, EA7223, BA7250 do not meet the 60-day calibration interval claim due to reagent instability and results may show an Abnormal Assay.accessdata.fda.gov
September 29, 201675417Class IITerminatedAptio Automation ModulesPossible overheating of power cord plugs used to connect to FlexLab and Aptio Automation systems.accessdata.fda.gov
September 15, 201675484Class IITerminatedDimension Vista Chemistry 1 Calibrator The Chemistry 1 Calibrator (KC110B) is an in vitro diagnostic product for the calibration of Calcium (CA), Cholesterol (CHOL), Creatinine (CREA/CRE2), Glucose (GLU), Lactic Acid (LASiemens determined that discrepant low calcium recovery of QC and patient samples can occur with Dimension Vista CHEM 1 CAL lots 5GM081 and 5GM082.accessdata.fda.gov
August 25, 201675256Class IIITerminatedDimension Vista IRON Flex reagent cartridgesSiemens Healthcare Diagnostics has become aware of deferoxamine interference with Dimension and Dimension Vista IRON assays at a different concentration than listed in the Instructions for Use (IFU).accessdata.fda.gov
August 3, 201674987Class IITerminatedDimension Vista Calcium (CA) Flex reagent cartridge Device Listing No.: D011443 Batch Number: 16060BBSiemens Healthcare Diagnostics determined that the Dimension Vista Calcium (CA) Flex reagent cartridge lot # 16060BB may produce erroneously low or high results from specific well sets.accessdata.fda.gov
June 17, 201674524Class IITerminatedSyva EMIT 2000 Theophylline - Catalog # 4P019UL /SMN#10445324 is a homogeneous enzyme immunoassay intended for use in the quantitative analysis of theophylline in human serum or plasma.Siemens Healthcare Diagnostics has confirmed the Syva EMIT 2000 Theophylline reagent lot G3, when run on a Beckman AU Clinical Chemistry System, and the ADVIA Chemistry Theophylline_2 (THEO_2) reagent lot 334018, may exhibit increased imprecision for commercially available Bio-Rad Liquichek TDM Quality Control Levels and patient samples.accessdata.fda.gov
May 5, 201676293Class IIITerminatedThe Enzyme 2 Calibrator is an in vitro diagnostic product for the calibration of Alanine Aminotransferase (ALTI and ALTI) and Aspartate Aminotransferase (AST) methods on the Dimension Vista System. For prescription use oComplaints of positive shift of patient and QC results when the ALTI assay is calibrated with the Dimension Vista Enzyme 2 calibrator. Internal investigation has confirmed that patient samples and QC material demonstrate a shift of up to 10% in comparison to results obtained using earlier calibrator lots.accessdata.fda.gov
March 17, 201673667Class IITerminatedAdvia Chemistry Assays - Cholesterol_2 concentrated and Cholesterol, LDL CholesterolSiemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn from patients receiving N-Acetylcysteine (NAC) or Metamizole. NAC is the accepted antidote for acetaminophen toxicity anaccessdata.fda.gov
March 8, 201673594Class IITerminatedSyva Emit Methotrexate Assay, is a homogeneous enzyme immunoassay intended for use in the quantitative analysis of methotrexate in human serum or plasma.Siemens Healthcare Diagnostics confirmed that Syva Emit Methotrexate Application (DVMTX.1) for Dimension Vista System does not meet On-Board Stability claim of 20 hours. Testing using reagent at the end of the 20 hours On-Board Stability has shown that values of methotrexate for patient and quality control samples increased.accessdata.fda.gov
February 16, 201673592Class IITerminatedDimension Vista Blood Urea Nitrogen (BUN) Flex reagent cartridge The BUN method is an in vitro diagnostic test for the quantitative measurement of urea nitrogen (an end product of nitrogen metabolism) in human serum, plaSiemens Healthcare Diagnostics has determined that Dimension Vista Blood Urea Nitrogen (BUN) lots 15215AE, 15243BB, 15264BA, 15299BB, 15300BA and 15341AC may exhibit inaccurate patient and/or Quality Control results. The issue has been isolated to Flex reagen cartridges manufactured from specific mold cavities.accessdata.fda.gov
February 9, 201673442Class IITerminatedDimension clinical chemistry system, Sirolimus (SIRO) Flex reagent cartridge (DF306 SMN 10464331) Lot EB6064, Open Well Instability The SIRO method is an in vitro diagnostic test for the quantitative measurement of sirolSiemens Healthcare Diagnostics has received customer complaints regarding QC shifts and imprecision after one day when using Dimension SIRO lot EB6064. They have confirmed SIRO lot # EB6064 does not meet the open well stability claim of 2 days.accessdata.fda.gov
November 3, 201573080Class IITerminatedDimension Vista System B2 Microglobulin Flex reagent cartridge and urine stabilizer Catalog #K7024 SMN: 10445889 Lot #15246MA Product Usage: The B2MIC method is an in vitro diagnostic test for the quantitative measuremenSiemens Healthcare Diagnostics has confirmed an increase in the rate of Abnormal Assay errors and calibration failures with the Dimension Vista B2MIC Flex reagent cartridge: Dimension Vista System Flex reagent cartridge and urine stabilizer B2MIC. In the unlikely event that a patient result is generated, a suppressed result would be in conflict with the patiaccessdata.fda.gov
September 30, 201572399Class IITerminatedDimension Vista System (MG); Flex reagent cartridge Catalog number K3057, SMN 10445158. For the quantitative measurement of magnesium in human serum, plasma and urine on the Dimension Vista System.Erroneous low results on a small number of reagent wells. There is the potential for under-recovery on certain wells for quality control (QC) and patient sample results. The under-recovery ranged from -0.3 mg/dL [0.12 mmol/L] to -1.6 mg/dL [0.66 mmol/L]; equivalent to a maximum negative bias of -88%.accessdata.fda.gov
September 24, 201572392Class IITerminatedADVIA Chemistry Hemoglobin A1c_3, A1c_3M Reagent kits. Used on the ADVIA 1200, 1650, 1800, 2400, and XPT Chemistry Systems. For in vitro diagnostic use in the quantitative determination of Hemoglobin A1c, a diabetes markReagent in these lots may demonstrate an increased occurrence of high %HbA1c bias, a positive bias averaging 0.6% HbA1c units, ranging from -0.1% to 1.1% HbA1c units. The maximum bias was observed at higher %HbA1c concentrations. QC samples may exhibit a similar bias.accessdata.fda.gov
August 26, 201582345Class IITerminatedsyngo Lab Data Manager System - Product Usage: syngo Lab Data Manager is a clinical system that assists medical laboratory professions with pre-analytic and post-analytic functions. It works in conjunction with multiple Software Issues.accessdata.fda.gov
July 23, 201571831Class IITerminatedDimension Vista B2-Microglobulin Flex Reagent Cartridge (B2MIC); Product Usage: The B2MIC method is an in vitro diagnostic test for the quantitative measurement of B2-Microglobulin in human serum, heparinized plasma, EDTcustomers are receiving a high number of Abnormal Assay Errors or are not able to calibrate B2MIC when using Flex reagent cartridge B2MIC various lots. In failure mode, there is the potential for falsely depressed beta2-Microglobulin results on the Dimension Vista system due to assay reagent contamination.accessdata.fda.gov
July 15, 201571725Class IITerminatedDimension CREA (Creatinine) and Dimension Vista CREA (Creatinine); The CREA method used on the Dimension clinical chemistry system is an in vitro diagnostic test intended for the quantitative determination of creatinine Siemens has confirmed that the Dimension CREA and Dimension Vista CREA may produce falsely depressed results up to - 12.7% and -22% respectively, for a creatinine concentration of 1.5 mg/dL when hemolysis exceeds 200 mg/dL and 300 mg/dL respectively.accessdata.fda.gov
June 30, 201571710Class IITerminatedADVIA Chemistry Acetaminophen reagents; for in vitro diagnostic use in the quantitative determination of acetaminophen in human serum and plasma (lithium heparin) on ADVIA Chemistry systems.A change in the concentration of N-acetylcysteine (NAC) that may cause interference for the ADVIA Chemistry Systems Acetaminophen assay for certain lots.accessdata.fda.gov
May 21, 201571315Class IITerminatedSiemens Healthcare Diagnostics Dimension Vista Systems, used with the Dimension Vista Intelligent Lab System software version 3.6.1. In vitro diagnostic analyzer.Two software issues may occur in Vista software version 3.6.1. Issue #1: Samples may stop processing without notification. Issue #2: Timing issue in Vista 1500 may cause wrong reagent or no reagent delivery. This may lead to unflagged, unexpected low results and results flagged with assay errors.accessdata.fda.gov
May 19, 201571362Class IITerminatedCentraLink" Data Management System; software is a network solution provider and multi-system data manager for the instruments and lab automation systems (LAS) within the lab. The CentraLink software consolidates data froSiemens Healthcare Diagnostics has determined that the sample query function that includes Instrument or Instrument Group as search criteria may not return all samples from the Dimension Vista systems if onboard aliquot support rules are configured in the CentraLink system.accessdata.fda.gov
May 11, 201571267Class IITerminatedFactor deficient plasma for the Siemens BCS / BCS XP System. In vitro diagnostic reagent for the determination of the activity of coagulation factor IX in human plasma by coagulometric methods.Discrepancies for Siemens BCS / BCS XP with dilution studies; erroneously high Factor IX results at the lower end of the measuring range.accessdata.fda.gov
April 29, 201571204Class IITerminatedEasyLink Data Management System; a clinical data management system that assists medical laboratory professionals with preanalytic and post-analytic functions in conjunction with multiple instruments, the laboratory inforSystem Limitations and Software Issues related to the following features: Custom reference ranges, User-initiated sample and result actions, Auto-verification and quality control rules, and Sample reports.accessdata.fda.gov
April 20, 201571096Class IITerminatedDimension Vista Systems LOCI Thyroid Stimulating Hormone; the TSH method is an in vitro diagnostic test for the quantitative measurement of Thyroid Stimulating Hormone in human serum and plasma on the Dimension Vista SysDimension Vista LOCI Thyroid Stimulating Hormone (TSH) Lot 14237AA may produce falsely depressed results ranging from -23% to -96% near the end of the well set due to inadequate reagent volume in a Flex well.accessdata.fda.gov
April 2, 201570913Class IITerminatedDimension EXL with LM, Dimension EXL 200, Dimension RxL, Dimension RxL HM, Dimension RxL Max, Dimension RxL Max HM, Dimension Xpand, Dimension Xpand HM, Dimension Xpand Plus, Dimension Xpand Plus HM. The Dimension EXL clCertain Dimension Integrated Chemistry Systems Instrument Power Configurations may have been installed with a non-standard instrument power plug.The use of a non-standard plug configuration as described may lead to a potential electrical hazard. The likelihood of potential clinical impact or injury due to this issue is extremely low.accessdata.fda.gov
March 25, 201571273Class IITerminatedDade Actin Activated Cephaloplastin Reagent; Liquid rabbit brain cephalin with plasma activator for use in the determination of the activated partial thromboplastin time (APTT) and other coagulation procedures requiring Recovery for assayed controls are out of assigned ranges. A drift >3 seconds in the normal APTT range and/or >15% in the pathological range has been observed. Patient samples with recoveries close to the medical decision points could exhibit a deviation up to 4 seconds for the normal range and up to 33% for the pathological range.accessdata.fda.gov
February 24, 201570627Class IITerminatedQuikLYTE Dilution Check: used to monitor and adjust for the dilution ratio on Dimension clinical chemistry systems with the QuikLYTE module. Intended Use of the QuikLYTE module : The Na+, K+, Cl and TCO2 methods on the DA positive bias beyond 5% resulting in a dilution check failure or an unnecessary dilution check correction if the positive bias is greater than 1% and less than 5%. The dilution check correction would be detected by QC; however, if not detected by QC, the calibration curve would be decreased and cause elevated sodium, potassium and chloride patient results.accessdata.fda.gov
January 15, 201570385Class IIITerminatedN Latex IgM; In-vitro diagnostic reagent for the quantitative determination of IgM in human cerebrospinal fluid (CSF) and in paired CSF/serum samples by means of particle-enhanced immunonephelometry using the BN II and BComplaints have been confirmed on failed proficiency testing due to serum samples recovering too low when using some N Latex IgM reagent kit lots 44018, 44019 and 44042.accessdata.fda.gov
December 16, 201470078Class IITerminatedADVIA Chemistry XPT interfaced to the CentraLink Data Management System V14x in specific configurations: The CentraLink system software is a network solution provider and multi-system data manager for the instruments andEnabling sending of preliminary/initial results on the ADVIA Chemistry XPT creates a risk that a critical result could be overwritten by the same result rather than showing the repeated result on CentraLink. A result could be erroneous and critical and appear to be verified upon repeat.accessdata.fda.gov
November 24, 201469937Class IITerminatedDimension Vista Myoglobin Calibrator (MYO CAL), Lot 4FD085 Product usage: in vitro diagnostic product for the calibration of Myoglobin (MYO) method on the Dimension Vista System.Dimension Vista Myoglobin Calibrator (MYO CAL) may produce a positive shift in MYO QC and Patient test results that exceeds acceptance criteria for this product. A positive shift observed up to 12% at MYO concentrations within and above the reference range of the assay. Depending on quality control limits, this drift may not be detected.accessdata.fda.gov
November 5, 201469687Class IITerminatedDimension Vista 500 Intelligent Lab System or Dimension Vista 1500 Intelligent Lab System: An in vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measurinCustomer complaints of discrepant flagged and/or un-flagged patient and QC results. Reagent probe performance may decline more quickly than anticipated and have an effect on assays with similar formulations when processed sequentially on the same reagent server.accessdata.fda.gov
September 30, 201469434Class IITerminatedSiemens Dimension HB1C Flex reagent cartridge; Dimension Hemoglobin A1c (HB1C) Flex reagent cartridge on the Dimension clinical chemistry system is an in vitro diagnostic assay for the quantitative determination of hemogCertain lots of the reagent cartridges show confirmed positive bias averaging 0.4% Hemoglobin A1c units and occasionally up to 1.0% HbA1c units for patient samples when compared to the National Glycohemoglobin Standardization Program (NGSP). QC samples may exhibit a similar bias.accessdata.fda.gov
September 24, 201469372Class IITerminatedsiemens Dimension Phenytoin Flex Reagent Cartridge The PTN method used on the Dimension clinical chemistry system is an in vitro diagnostic test intended to measure phenytoin (dilantin, diphenylhydantoin), an anti-epilepInternal testing has confirmed a low absorbance range between the levels 1 and 5 calibrators with this lot resulting in the potential for a positive or negative bias and imprecision across the PTN assay range.accessdata.fda.gov
August 28, 201469149Class IITerminatedDimension Vista Mass CKMB Isoenzyme Calibrator (MMB CAL) an in vitro diagnostic product for the calibration of Creatine Kinase MB Isoenzyme (MMB) method on the Dimension Vista System.Siemens Healthcare Diagnostics has determined that Dimension Vista® Mass CKMB Isoenzyme Calibrator (MMB CAL) shows drift during routine stability monitoring that exceeds our acceptance criteria for drift over the shelf life of this product. Siemens has observed drift from 3% to 12% at MMB concentrations across the assay range. Depending on quality control liaccessdata.fda.gov
August 19, 201469129Class IITerminatedSiemens CentraLink Data Management System, software version 14. The CentraLink system software is a network solution provider and multi-system data manager for the instruments and lab automation systems (LAS) within the Siemens Healthcare Diagnostics has identified a task scheduler issue with the CentraLink" Data Management System, software version 14. The issue may cause the software to stop executing commands, including uploading validated results to the LIS. The issue is related to an internal software timer that overflows after 24 days. Automated rules triggered by taskaccessdata.fda.gov
August 18, 201469063Class IITerminatedSiemens Dimension Vista CHEM 1 CAL, lot 3GM081. The CHEM 1 CAL is an in vitro diagnostic product for the calibration of Calcium (CA), Cholesterol (CHOL), Creatinine (CREA), Glucose (GLU), Lactic Acid (LA), Magnesium (MG)Siemens Healthcare Diagnostics has received complaints for low recovery of Magnesium (MG) Quality Control (QC) and patient samples following calibration of MG with the Dimension Vista® CHEM 1 CAL, lot 3GM081. Investigation by Siemens confirms that QC and patient samples under-recovers MG by 0.25 mg/dL [0.10 mmol/L] across the assay range following calibratioaccessdata.fda.gov
August 14, 201469334Class IITerminatedDimension Vista HbA1cIn March, Siemens Healthcare Diagnostics issued an Urgent Medical Device Correction for decreased recovery of patient samples with the Dimension Vista® CSA & CSAE Flex® reagent cartridges when whole blood samples are run from Small Sample Containers (SSC). Siemens has confirmed that when whole blood samples are run from SSC, HbA1c values may exhibit a percenaccessdata.fda.gov
July 16, 201468854Class IITerminatedSiemens Dimension EXL Integrated Chemistry System in vitro diagnostic devices intended to measure a variety of analytes in human body fluids. All Serial #s of material #s: 10636929, 10636928, 10486890, 10472176, 10639337The Reagent Lid hinge may lose its effectiveness and slowly shift downward during maintenance procedures, potentially resulting in physical contact and injury to the operator.accessdata.fda.gov
July 15, 201468848Class IITerminatedSiemens Dimension Chemistry Wash (RD701) is an accessory of the flex cartridge system used on the Siemens Dimension RxL and Xpand assays. The wash buffer is used to clean the probe sensor between uses and prepares it forSiemens Healthcare Diagnostics has received complaints for the Dimension Chemistry Wash (RD701) of QC and patient sample result accuracy shifts on Troponin I, CTNI (RF421C), LTNI (RF521C); Free T4, FT4 (RF410); Thyroid Stimulating Hormone, TSH (RF412); and N-terminal pro-brain natriuretic peptide, PBNP (RF423A) and LPBN (RF523A) when using Dimension® Chemistaccessdata.fda.gov
May 27, 201468400Class IIITerminatedDimension Integrated Chemistry Systems intended to measure a variety of analytes in human body fluids.There is a misassembly issue with the photometer installed on Dimension Integrated Chemistry Systems instruments. Through internal investigation by Siemens Healthcare Diagnostics has confirmed that a limited number of Dimension photometers were misassembled. These photometers are performing within specifications, but may lead to a shortened life of the sourcaccessdata.fda.gov
May 20, 201468394Class IITerminatedsyngo Lab Data Manager, SMN 10800057, 10803189, and 10804573.Certain configuration parameters may cause the reference ranges to not hold results as expected and release them to the Laboratory Information System (LIS) that should have been held for manual review.accessdata.fda.gov
April 14, 201468076Class IITerminatedSiemens Healthcare Diagnostics Vista Air Compressor. Vista AirCompressor replacement part: SMN 10706557 SKIT Air Compressor Assy, used on the Dimension Vista 500 and Dimension Vista 1500 systems. Siemens Healthcare DiagnA small number of Vista Air Compressors were miswired, which if installed and powered up, could cause a fire, or become an electrical shock hazard.accessdata.fda.gov
March 19, 201467787Class IITerminatedDimension Vista CSA and CSAE The Cyclosporine method is an in vitro diagnostic test for the quantitative measurement of cyclosporine A (CSA) in human whole blood on the Dimension Vista System. Measurements of CSA are useA complaint was received of Dimension Vista CSA and CSAE under-recovery of cyclosporine when patient samples are run from the Small Sample Container. The under-recovery that has been observed is 18 to 44%. In March 2014, Siemens recalled due to the complaint received of Dimension Vista CSA and CSAE reporting under-recovery of cyclosporine when patient sampleaccessdata.fda.gov
January 6, 201467235Class IITerminatedDimension Vista Enzyme 1 Calibrator (ENZ 1 CAL) lots 3FD034 and 3HD012. An in vitro diagnostic multi-analyte calibrator for the calibration of Amylase (AMY), Gamma-Glutamyl Transferase (GGT), Lactate Dehydrogenase (LDH),Complaints were received regarding Quality Control (QC) shifts with Pseudocholinesterase (PCHE) and imprecision during PCHE calibration with the Dimension Vista Enzyme 1 Calibrator (ENZ 1 CAL).accessdata.fda.gov
December 17, 201367030Class IITerminatedSiemens ADVIA 1200 and ADVIA 1650 Chemistry Systems. Automated, clinical chemistry analyzers that can run tests on human serum, plasma, or urine.An overflow flag //// is displayed in the result column for a test when the algorithm for the test cannot calculate a result or when the concentration cannot be determined because it is outside the absorbance limits, and it is possible for the user to misinterpret or edit the result.accessdata.fda.gov
December 5, 201367057Class IITerminatedDimension Vista Cyclosporine Flex reagent cartridge an in vitro diagnostic test for the quantitative measurement of cyclosporine A (CSA) in human whole blood on the Dimension Vista System. Measurements are used as an aidComplaints were received regarding variability in recovery of QC and patient results with certain lots of the Dimension Vista CSA Flex reagent cartridges.accessdata.fda.gov
November 6, 201367027Class IITerminatedSiemens ADVIA Chemistry Systems models 1200, 1650, 1800 and 2400 Product Usage: The ADVIA Chemistry Systems models 1200, 1650, 1800 and 2400 (also known as Clinical Chemistry Systems) are high throughput instruments whicThe ADVIA Chemistry software systems using certain software versions allows the system to automatically run assay calibrations and quality control (QC).accessdata.fda.gov
October 30, 201366694Class IITerminatedSiemens CentraLink" Data Management System V14.0.4, V14.0.5 or V14.0.8 The CentraLink system software is a network solution provider and multi-system data manager for the instruments and lab automation systems (LAS) withUnder extremely rare circumstances, a patient result that had been previously disabled may be released without proper review. (Disabled Test in CentraLink System or Aptio System May Become Enabled in CentraLink System.)accessdata.fda.gov
October 7, 201366585Class IITerminatedUser Defined Method Flex Assignment/Siemens Dimension Vista 500 or Dimension Vista 1500 System with software version 3.5.1 or lower User Defined Method Flex Assignment/Siemens Dimension Vista 500 or Dimension Vista 1500 When utilizing the Routine Inventory screen to enter a User Defined Method (EMPTY) Flex the system may assign the User Defined Method Flex to a different Flex that is currently in inventory on the system, and then use the incorrect Flex Cartridge to process the user defined method.accessdata.fda.gov
September 18, 201366363Class IITerminatedSiemens Dimension Vista Homocysteine Flex Reagent Cartridge The HCYS method is an in vitro diagnostic test for the quantitative measurement of total homocysteine in human serum, heparinized plasma and ETDA plasma on the Dimension Vista HCYS lot 13064MA shows erratic recovery of QC and patient samples.accessdata.fda.gov
September 17, 201366364Class IITerminatedSiemens Dimension LOCI TNI Troponin I Calibrator RC 621. The LOCI TNI Troponin I Calibrator is an in vitro diagnostic product for the calibration of the cardiac troponin I (TNI) method for the Dimension clinical EXL inteSiemens Dimension LOCI TNI Troponin I calibrator lot 3DD007 may demonstrate an average upward shift of 24% in QC and patient results following calibration.accessdata.fda.gov
August 30, 201366267Class IITerminatedEmit 2000 Phenobarbital Assay and Syva Emit 2000 Phenobarbital AssayImprecision with certain lotsaccessdata.fda.gov
August 13, 201368965Class IITerminatedSiemens EasyLink Informatics System V4.0/V5 Siemens, Material Number (SMN) 10444799, 10444800, 10487219 A clinical data management system that assists medical laboratory professionals with preanalytic and post-analytic fMay not perform as intended under certain conditions, causing the release of results to the Laboratory Information System (LIS) that should have been held for manual review due to auto-verification rules or the delay/omission of result transmission to the LIS.accessdata.fda.gov
July 1, 201365706Class IITerminatedDimension Tacrolimus Flex reagent cartridge (DF107) and Dimension TACR CAL (DC107) Product Usage: The TACR method is an in vitro diagnostic test intended to quantitatively measure Tacrolimus in human whole blood on the DSiemens initiated a recall due to confirmed complaints of low patient sample recovery with Dimension TACR Flex Reagent cartridge (DF107) lot BB4087 and its linked calibrator (DC 107) lot 3BD029. Falsely low Tacrolimus results across the assay range may lead to alterations in dosing.accessdata.fda.gov
June 19, 201365607Class IITerminatedDimension Vista 500 and Dimension Vista 1500 System Aliquot Well Double Dispense with software versions 3.5.1 and 3.6. In vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixiSiemens is conducting a field correction for Dimension Vista 500 and Dimension Vista 1500 systems using software versions 3.5.1 and 3.6. Under specific rare conditions which require a system reset, there is a potential for a sample to be dispensed into an aliquot well that has previously been used for a QC or calibrator product from a Vista vial. If two sampaccessdata.fda.gov
June 5, 201365152Class IITerminatedDimension(R) Mass Creatine Kinase MB Isozyme Calibrator (RC420) The Mass Creatine Kinase MB isozyme Calibrator is an in vitro diagnostic product intended to be used to calibrate the Creatine Kinase MB Isozyme method for Siemens Healthcare Diagnostics has received complaints that the lyophilized cake is not fully dissolved after the stated time in the MMB calibrator Instructions For Use (IFU). The frequency of this occurrence is low but if it occurs, gel-like clumps may be observed.accessdata.fda.gov
May 20, 201365408Class IITerminatedDimension Vista(R) 500 and Dimension Vista(R) 1500 - Reloaded Vista Vials - limited to systems using software versions 3.4 and 3.5.1. Diagnostic device intended to determine a variety of analytes in human body fluids.There is the potential for the vial volume of "in use" Vista calibrators, controls, or sample diluent to incorrectly revert to full volume when removed and reloaded. Dimension Vista(R) 500 and Dimension Vista(R) 1500 - Reloaded Vista Vials - limited to systems using software versions 3.4 and 3.5.1accessdata.fda.gov
May 10, 201365147Class IITerminatedsyngo(R) Lab Data Manager - Version VA11B and VA12A Systems Securely consolidates data from multiple lab instruments, the LIS and Siemens StreamLAB(R) Automation Solutions. It provides autoverification, integrated QC capUnder certain conditions the system may not perform as intended, causing the release of results to the Laboratory Information System that should have been held for manual review due to auto-verification rules or the delay/omission of result transmission to the LIS.accessdata.fda.gov
May 6, 201365131Class IITerminatedDimension(R) Chemistry Wash (RD701), Siemens Material Number (SMN) 10445052 Product Usage: Used in the Dimension(R) system with the heterogeneous moduleSiemens Healthcare Diagnostics received complaints of Chemistry Wash causing QC and patient sample result shifts on CTN1, LTN1, FT4, TSH, PBNP and LPBN when using Chemistry Wash lots RD23031, RD23111, RD23241, RD23311, RD23391, and RD23461. These lots shipped between 12/12/2012 and 3/22/2013. Internal investigation has confirmed shifts can be encountered in accessdata.fda.gov
April 25, 201365051Class IITerminatedDimension(R) TACR Flex(R) reagent cartridge (DF107) The TACR method is an in vitro diagnostic test intended to quantitatively measure Tacrolimus in human whole blood on the Dimension(R) clinical chemistry system. MeasureSiemens has confirmed that the TACR method may demonstrate reduced on-board stability which may result in imprecise and inaccurate QC and patient results.accessdata.fda.gov
April 22, 201365409Class IITerminatedHB1C Flex(R) Reagent Cartridge (DF105A, Siemens Material Number 10483822) for the Dimension(R) Clinical Systems. Dimension(R) Hemoglobin A1c (HB1C) Flex(R) reagent Cartridge on the Dimension(R) clinical chemistry system Positive bias on the lots listed compared to alternate methods and a higher frequency of "Above Assay Range" flags with the lots listed.accessdata.fda.gov
March 11, 201363804Class IITerminatedDade(R) Actin(R) FSL Activated PTT Reagent. For use in the determination of the activated partial thromboplastin time (APTT).Siemens has observed that the listed lot numbers show an increase in Heparin sensitivity over the shelf life which is demonstrated by testing with Dade(R) Citrol(R) Heparin Control, low and high.accessdata.fda.gov
February 27, 201364570Class IIITerminatedSiemens Dimension(R) EXL(TM) LM (Siemens Material Number 10486890). Intended to measure a variety of analytes in human body fluids.Through investigation of customer complaints, Siemens Healthcare Diagnostics has confirmed an increase in System Check failures due to high System Check LOCI results. Upon further investigation, Siemens has determined that many of these errors are due to the current limit set for System Check LOCI results. The errors have no impact on results, but they may caccessdata.fda.gov

Compare with other makers

Updated August 4, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.