Shanghai United Imaging Healthcare Co.,ltd.: FDA-registered device maker in Shanghai, China, 66 510(k) clearances

Shanghai United Imaging Healthcare Co.,ltd. is registered with the FDA (registration 3011015597) in Shanghai, China. It lists 12 device types. The FDA files 66 510(k) clearances under its listings, the newest dated July 28, 2026. 15 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 3, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3011015597
Address
No.2258 Chengbei Rd. Jiading District, Shanghai, China, 201807
Owner or operator
Shanghai United Imaging Healthcare Co.,Ltd. (10057992)
Roles
Manufacturer
First device listed
September 4, 2018
Registered through
2027
Brand names listed
HYPER AiR, HYPER DLR, HYPER Focus, uAngio AVIVA CX, uCT 530, uCT 550, uCT 760, uCT 780 and more

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
July 28, 2026K261427uMI Panvivo (uMI Panvivo M)KPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
November 26, 2025K252000uDR Arria & uDR ArisKPRSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
September 25, 2025K252371uMR 680LNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
September 24, 2025K250045uWS-Angio ProLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
September 19, 2025K251167uDR Aurora CXKPRSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
September 12, 2025K250040uWS-AngioLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
August 5, 2025K250246uMR JupiterLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
July 17, 2025K251839uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI Panvivo S)KPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
July 17, 2025K243547uMR UltraLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
July 16, 2025K243397uMR 680LNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
June 17, 2025K243666uOmniscanLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
May 21, 2025K243122uMR OmegaLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
May 16, 2025K243617uCT ATLAS Astound with uWS-CT-Dual Energy Analysis; uCT ATLAS with uWS-CT-Dual Energy AnalysisJAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
May 14, 2025K242624Medical Image Post-processing Software (uOmnispace.CT)QIHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
May 12, 2025K243632uWS-Angio BasicLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 28, 2025K243376uAngio AVIVA CXOWBSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
January 14, 2025K241166uCT 550JAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
January 7, 2025K241079uCT 780JAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
December 12, 2024K243538uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI Panvivo S)KPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
November 1, 2024K241068uDR 780iKPRSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
October 10, 2024K242515uDR 380i ProIZLSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
August 30, 2024K241585uMI PanoramaKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
August 15, 2024K241596uMI PanvivoKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
May 24, 2024K234154uPMR 790OUOSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
May 17, 2024K233209uOmnispace.CTQIHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 26, 2024K233673uMR JupiterLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 17, 2024K233186uOmnispace.MRQIHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 10, 2024K240744uMR 680LNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
March 22, 2024K240540uMR OmegaLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
January 18, 2024K231762uEXPLORERKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
December 20, 2023K233176uOmnispace.MILLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
November 29, 2023K231482uCT ATLAS Astound with uWS-CT-Dual Energy Analysis, uCT ATLAS with uWS-CT-Dual Energy AnalysisJAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
October 3, 2023K232712uMI PanoramaKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
August 1, 2023K230162uCT 760 with uWS-CT-Dual Energy Analysis, uCT 780 with uWS-CT-Dual Energy AnalysisJAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
July 26, 2023K231572uMI PanoramaKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
July 20, 2023K230039uOmnispaceQIHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
May 23, 2023K230152uMR OmegaLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
March 10, 2023K223325uMI PanoramaKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
February 16, 2023K223028uCT ATLAS Astound with uWS-CT-Dual Energy AnalysisJAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
February 16, 2023K222755uMR 680LNHSubstantially EquivalentShanghai United Imaging Intelligence Co., Ltd.accessdata.fda.gov
November 14, 2022K222540uPMR 790OUOSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
October 27, 2022K220332uMR Omega with uWS-MR-MRSLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
September 30, 2022K222339uDR 380i ProIZLSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
August 11, 2021K203448uCT ATLAS with uWS-CT-Dual Energy AnalysisJAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 30, 2021K210001HYPER AiRKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 9, 2021K210418HYPER FocusKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
August 4, 2020K193210HYPER DLRKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
June 11, 2020K192630uWS-MILLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
June 1, 2020K192601uWS-MRQIHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
March 27, 2020K193200uMR OmegaLNHSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
February 25, 2020K200016uCT 530, uCT 550JAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
January 26, 2020K193241Emission Computed Tomography SystemKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
November 20, 2019K192672uPMR 790OUOSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
September 12, 2019K192293uDR 592h, uDR 596iKPRSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
June 24, 2019K183170uWS-CTLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
March 22, 2019K183164uWS-MRLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
December 18, 2018K182938Emission Computed Tomography SystemKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
November 7, 2018K173001uWS-CTLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
November 7, 2018K172999uWS-MRLLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
October 12, 2018K182237uMI 550 PET/CT SystemKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
August 14, 2018K181414uCT 530, uCT 550JAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
June 27, 2018K181413uDR 592h, uDR 596iKPRSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 13, 2018K172143uMI 780 PET/CT SystemKPSSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
April 5, 2018K172998uWS-MILLZSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
March 2, 2018K172135uCT Computed Tomography X-ray SystemJAKSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov
January 26, 2018K173953uDR 780iKPRSubstantially EquivalentShanghai United Imaging Healthcare Co., Ltd.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
August 11, 202699731Class IIOngoingComputed Tomography X-ray System, Model: uCT 530 with softwarePositron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on the Patient Administration interface, which may result in the need for rescans.accessdata.fda.gov
March 1, 202391870Class IIOngoingShanghai United Imaging Healthcare Co., Ltd. Positron Emission Tomography (PET) and Computed Tomography (CT), Model uMI 550 Part Number: 88000657 88000057Due to a software issue where the process of patient scanning, the scatter correction may occasionally fail with will potentially cause a failure of the PET image reconstruction and generation of PET images.accessdata.fda.gov
May 30, 202290888Class IIOngoingPositron Emission Tomography and Computed Tomography System, Model: uMI 550The wireless VSM module of a mobile PET/CT system, operating in an environment with strong Wi-Fi signals, may experience ECG signal and respiratory signal loss due to Wi-Fi interference. ECG and respiratory signal loss during acquisition can result in the failure of ECG and respiratory-gated reconstruction of the PET scan, which may require rescanning of theaccessdata.fda.gov
August 2, 202188521Class IIOngoinguMI 550 System - Product Usage: intended to be operated by qualified healthcare professionals to assist in the detection, localization, diagnosis, staging, restaging, treatment planning and treatment response evaluation The EXAM acquisition workflow could occasionally freeze after canceling the PET scan.accessdata.fda.gov
January 25, 202187289Class IITerminatedDigitial Medica X-ray Imagining System, Model: uDR 596i, RX, CE0123, UDI:(01) 06971576833023 - Product Usage: intended to used by a qualified/trained doctor or technician on both adult and pediatric subjects for taking dThere is a potential for the X-Ray tube head (Touch screen interface) to perform an uncommanded motion. This could result in a collision with the patient.accessdata.fda.gov
August 5, 202086269Class IIOngoingComputed Tomography X-Ray System, Model uCT 530, Rx, CE, GTIN: 06971576831012 - Product Usage: ntended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at differenA potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.accessdata.fda.gov
July 16, 202085948Class IITerminateduEXPLORER PET/CT Diagnostic Imaging System - Product Usage: This system is intended to be operated by qualified healthcare professionals to assist in the detection, localization, diagnosis, staging, restaging, treatment 1) 1) Potential intermittent issue may cause image data problems, may lead to artifacts; 2) Potential intermittent scout scanning interruption due to angle signal drift caused by external interference; 3) Metal edge overlap of mylar strip in gantry may create sharp edge. May lead to repeat scanning and abrasions.accessdata.fda.gov
June 20, 202085868Class IIOngoingComputed Tomography X-ray System; Model uCT 760; Rx; UDI: (01) GTIN: 06971576831043 - Product Usage: intended to produce cross-sectional images of the body using computer reconstruction of x-ray transmission data taken aThe metal edge overlap of the mylar strip in the gantry was uneven, which may create a sharp edge.accessdata.fda.gov
May 23, 202085771Class IIOngoingComputed Tomography X-ray System, Model: uCT 550, GTIN: 06971576831036 Intended use The uCT Computed Tomography X-ray System uCT 530/uCT 550 is a computed tomography X-ray system intended to produce cross-sectional imageTwo issues were identified with the computed tomography x-ray system including a service function which may cause false marking of a bad channel resulting in ring artifacts, and potential intermittent scout scanning interruption due to occasional angle signal drift.. If these problems occur, it may be necessary to rescan the patient resulting in an additionaaccessdata.fda.gov
May 8, 202085809Class IIOngoinguCT 530 Computed Tomography X-Ray SystemTwo issues were identified with the computed tomography x-ray system including a service function which may cause false marking of a bad channel resulting in ring artifacts, and potential intermittent scout scanning interruption due to occasional angle signal drift.. If these problems occur, it may be necessary to rescan the patient resulting in an additionaaccessdata.fda.gov
May 8, 202085804Class IITerminateduCT 760 System, Computed Tomography X-ray SystemTwo issues were identified with the computed tomography x-ray system including an intermittent issue which may affect image data leading to artifacts; and intermittent scout scanning interruption due to occasional angle signal drift. This may result in the need for rescanning of the patient with the patient receiving an additional dose of radiation and possiaccessdata.fda.gov
March 26, 202085453Class IITerminatedPositron Emission Tomography and Computed Tomography System, Model: uMI 550, Material Number: 88000057 - Product Usage: This system is intended to be operated by qualified healthcare professionals to assist in the detectIn affected software version, of Positron emission tomography and computed tomography system, the CT Hounsfield unit curve may not display in real time when using the bolus tracking protocol with the tracker scan function. If this occurs, the subsequent clinical scanning protocols will need to be started manually, which may effect image enhancement, and may accessdata.fda.gov
February 27, 202085196Class IITerminateduDR 596i Digital Medical X-Ray Imaging System - Product Usage: intended to use by a qualified/ trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic exposures of the skull, Two issues were identified with the stationary x-ray system. 1. Some position illustrations in the patient exam interface show the incorrect anatomical position for the standard of care. When the image is acquired with the wrong reference position, clinical diagnostic requirements cannot be met.T2. Where image stitching is used, the left and right tag informaccessdata.fda.gov
August 26, 201985340Class IITerminatedPositron Emission Tomograpy and Computed Tomography System, Model: uMI 550, with software version R001.3.0.0.750505, Rx Only, CE 0197, UDI: (01)06971576832026 - Product Usage: This system is intended to be operated by quPotential sporadic software bugs in R001.3.0.0.750505 software version may cause an issue with the PET acquisition raw data causing reconstruction problems during PET/CT scanning and could possibly cause rescans of patients with additional dose.accessdata.fda.gov
July 30, 201990104Class IITerminatedDigital Medical X-ray Imaging System, Model: uDR 596i, uDR 592hX-ray imaging system positioning image and protocol label is reversed for Flexion and Extension on C-Spine and L-Spine, this will cause the image to be incorrectly labeled and may cause the patient to have a repeat exposure.accessdata.fda.gov

Compare with other makers

Updated September 25, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.