Data / Medical devices / Switzerland / Sentec AG
Sentec AG: FDA-registered device maker in THERWIL Basel-Landschaft, Switzerland, 6 510(k) clearances
Sentec AG is registered with the FDA (registration 3004149774) in THERWIL Basel-Landschaft, Switzerland. It lists 6 device types. The FDA files 6 510(k) clearances under its listings, the newest dated August 7, 2025. 9 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3004149774
- Address
- Ringstrasse 39, THERWIL Basel-Landschaft, Switzerland, CH-4106
- Owner or operator
- SENTEC AG (9064082)
- Roles
- Contract manufacturer, Manufacturer, Specification developer
- First device listed
- December 16, 2008
- Registered through
- 2026
- Brand names listed
- 103149 Calibration Gas tCOM+, 103164 tCOM+ Patient Monitor, 103420 Sensor Adapter Cable (Regular) tCOM+, 103421 Sensor Adapter Cable (Long) tCOM+, 103422 Sensor Adapter Cable (Extra Long) tCOM+, 103520 Non-Adhesive Wrap, 103583 LuMon Contact Gel, 1ST120-100 LuMon Connector 2 and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Monitor, Carbon-Dioxide, Cutaneous | LKD | 2 | Contract manufacturer, Manufacturer, Specification developer | accessdata.fda.gov |
| Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia | KLK | 2 | Contract manufacturer, Manufacturer, Specification developer | accessdata.fda.gov |
| Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia | LPP | 2 | Contract manufacturer, Manufacturer, Specification developer | accessdata.fda.gov |
| Oximeter | DQA | 2 | Contract manufacturer, Manufacturer, Specification developer | accessdata.fda.gov |
| Oximeter, Ear | DPZ | 2 | Contract manufacturer, Manufacturer, Specification developer | accessdata.fda.gov |
| Ventilatory Electrical Impedance Tomograph | QEB | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| August 7, 2025 | K243765 | LuMon(TM) System | QEB | Substantially Equivalent | Sentec AG | accessdata.fda.gov |
| May 17, 2024 | K232516 | Sentec Digital Monitoring System (SDMS) tCOM+ | LKD | Substantially Equivalent | Sentec AG | accessdata.fda.gov |
| December 17, 2015 | K151329 | SenTec Digital Monitor, OxiVenT Sensor, V-Sign Sensor, Staysite Adhesive Pad, V-STATS PC Software including V-CareNet | LKD | Substantially Equivalent | Sentec AG | accessdata.fda.gov |
| December 3, 2010 | K101690 | SENTEC DIGITAL MONITOR, V-SIGN SENSOR AND V-SIGN SENSOR 2 WITH DIGITAL SENSOR ADAPER CABLE | LKD | Substantially Equivalent | Sentec AG | accessdata.fda.gov |
| September 12, 2007 | K071672 | SENTEC DIGITAL MONITORING SYSTEM | DQA | Substantially Equivalent | Sentec AG | accessdata.fda.gov |
| August 9, 2004 | K041548 | SENTEC DIGITAL MONITOR MODEL #SDM | LKD | Substantially Equivalent | Sentec, Inc. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| July 25, 2023 | 92833 | Class II | Ongoing | Membrane Changer Single-Use, REF MC, each package contains 3 changers; Membrane Changer Reloadable, REF MC-R, each package contains 3 changers; and Membrane Changer Insert, REF MC-I, each package contains 5 inserts. All | During rework of components during the manufacturing process, an additional piece of material may have been left in the device, which may result in an impact on measurement performance. | accessdata.fda.gov |
| May 2, 2023 | 92355 | Class II | Ongoing | V-Sign Sensor 2, REF VS-A/P/N, a component of Sentec Digital Monitoring System (model SDMS). | The sensors may experience an out-of-box failure because after recalibration, the sensors stayed in the software mode "production" and were not reset to "released" mode. | accessdata.fda.gov |
| August 22, 2022 | 90938 | Class II | Terminated | sentec 24 / MARe-SF Multi-Site Attachment Ring Easy, For sensitive / fragile skin. Used in continuous, noninvasive carbon dioxide and/or oxygen tension monitoring. | Weak skin adhesion. | accessdata.fda.gov |
| December 10, 2020 | 87054 | Class II | Terminated | SenTec Digital Monitor, Model SDM, is a portable stand-alone patient monitor indicated for continuous, noninvasive patient monitoring of carbon dioxide partial pressure (PCo2), oxygen partial pressure (POs), functional o | Device requires the use of an Isolation Transformer in combination with the SDM in home care settings to comply with applicable safety standards. | accessdata.fda.gov |
| May 2, 2019 | 83115 | Class II | Terminated | SenTec Membrane Changer (reloadable) [9 pcs] - Product Usage: Is indicated for continuous, non-invasive monitoring of carbon dioxide tension and oxygen tension as well as oxygen saturation and pulse rate in adult and ped | There is an increased chance (approx. 5%) of no electrolyte or a reduced amount of electrolyte being applied to the sensor during the membrane change procedure. | accessdata.fda.gov |
| September 15, 2016 | 75257 | Class II | Terminated | SDMS (SenTec Digital Monitoring System) | Sentec AG found that with one batch of an internal SenTec Monitor component (Docking Station Module) there is a risk that a fastening screw could become loose under certain circumstances. A loose screw within the monitor can create uncontrolled electrical connections, including short circuits, with the risk of smolder or fire and electrical shock (patient an | accessdata.fda.gov |
| March 25, 2015 | 70878 | Class II | Terminated | Sentec, V-Sign Sensor 2 (REF VS-A/P/N), Reusable / Nonsterile / Waterproof, SenTec AG, CH-4106, Therwil, Switzerland. The SenTec Digital Monitoring System (SDMS) is used for continuous and non-invasive monitoring of tran | SenTec is voluntarily replacing V-Sign Sensors 2 due to pre-mature deterioration of a part of the PCO2 measuring unit and thus disabling PCO2-monitoring. This means that the affected sensors reach their end-of-life earlier than normally expected requiring the sensor`s replacement. There is no increased risk for the patient or operator, because the aforementi | accessdata.fda.gov |
| November 5, 2012 | 63631 | Class II | Terminated | SenTec V-Sign Membrane Changer (VS-MC), 9 pieces. The SenTec V-Sign Membrane Changer is indicated for use with the V-Sign Sensor only. The V-sign Sensor is indicated for use with the SenTec Digital Monitor when continuou | A manufacturing defect was observed for the membrane changer insert that does not allow electrolyte to be present under the new membrane. The PCO2 performance of a sensor without electrolyte will be deteriorated. | accessdata.fda.gov |
| July 9, 2012 | 62589 | Class II | Terminated | SenTec, V-Sign"2 Sensors The SenTec Digital Monitoring System (SMDS) is used for continuous and noninvasive real-time monitoring of ventilation (tcPCO2) and oxygenation (SpO2). | SenTec is recalling a number of V-Sign"2 Sensors due to a problem regarding configuration parameter writing during manufacturing. | accessdata.fda.gov |
Compare with other makers
- All makers of Monitor, Carbon-Dioxide, Cutaneous
- All makers of Oximeter, Ear
- All makers of Oximeter
- All makers of Ventilatory Electrical Impedance Tomograph
- All makers of Monitor, Oxygen, Cutaneous, For Uses Other Than For Infant Not Under Gas Anesthesia
- All makers of Monitor, Oxygen, Cutaneous, For Infant Not Under Gas Anesthesia
Updated August 7, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.