Data / Medical devices / South Korea / Rayence Co., Ltd.
Rayence Co., Ltd.: FDA-registered device maker in Hwaseong-si Gyeonggi, South Korea, 38 510(k) clearances
Rayence Co., Ltd. is registered with the FDA (registration 3009048384) in Hwaseong-si Gyeonggi, South Korea. It lists 5 device types. The FDA files 38 510(k) clearances under its listings, the newest dated July 31, 2026. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3009048384
- Address
- 14,Samsung 1-ro 1-gil & #201, 13, Samsung 1-ro 2-gil, Hwaseong-si Gyeonggi, South Korea, 18449
- Owner or operator
- Rayence Co., Ltd. (10036755)
- Roles
- Manufacturer
- First device listed
- March 14, 2012
- Registered through
- 2026
- Brand names listed
- 0909FCB, 1212FCA, 0909FCC, 0909FCC-HS, 0909FCE, 0909FCE-HS, 1212FCA, 1417WCC_127um, 1417WCC_140um and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Full Field Digital, System, X-Ray, Mammographic | MUE | 2 | Manufacturer | accessdata.fda.gov |
| Solid State X-Ray Imager (Flat Panel/Digital Imager) | MQB | 2 | Manufacturer | accessdata.fda.gov |
| System, Image Processing, Radiological | LLZ | 2 | Manufacturer | accessdata.fda.gov |
| System, X-Ray, Extraoral Source, Digital | MUH | 2 | Manufacturer | accessdata.fda.gov |
| System, X-Ray, Fluoroscopic, Image-Intensified | JAA | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| July 31, 2026 | K253800 | 0909FCE, 0909FCE-HS | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| March 12, 2025 | K243849 | 2430TCA with Xmaru W | MUE | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| September 9, 2024 | K242394 | Digital Flat Panel X-ray Detector (1717WCE, 1717WCE-HR, 1717WCE-HS, 1717WCE-GF) | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| March 7, 2024 | K240371 | 0909FCC, 0909FCC-HS | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| June 21, 2023 | K231467 | 1417WCE, 1417WCE-HR, 1417WCE-HS, 1417WCE-GF | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| October 18, 2021 | K212753 | 0909FCB, 1212FCA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| June 21, 2021 | K202902 | 2430MCA with Xmaru W | MUE | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| April 28, 2021 | K210985 | 1717FCC | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| October 26, 2020 | K202722 | 1212FCA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| July 23, 2020 | K201796 | 1717SCV, 1717SGV | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| April 30, 2019 | K190866 | XmaruView V1 (Xmaru Chiroview, Xmaru Podview) | LLZ | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| March 1, 2019 | K183478 | ClearON Mobile | LLZ | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| June 12, 2017 | K171418 | 1417WCC_127um and1417WCC_140um | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| June 12, 2017 | K171417 | 1417WGC_127um and 1417WGC_140um | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| June 9, 2017 | K171420 | 1717SCC_127um and 1717SCC_140um | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| June 9, 2017 | K171419 | 1717SGC_127um and 1717SGC_140um | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| October 6, 2016 | K162519 | 1717WCC / 1717WGC | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| October 6, 2016 | K162518 | 1012WCC, 1012WGC | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| April 8, 2016 | K160579 | Xmaru View V1 and Xmaru PACS, Medical Image Processing Software | LLZ | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| November 10, 2015 | K153060 | Digital Dental Intra Oral Sensor, EzSensor Classic, EzSensor HD, HDI-P, HDI-S | MUH | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| July 19, 2015 | K151707 | EzSensor Soft, EzSensor Soft i, EzSensor Bio, and EzSensor Bio i | MUH | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| March 27, 2015 | K150150 | 1717SGN / 1717SCN Digital Flat Panel X-ray Detector | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| July 16, 2014 | K141566 | SOLID STATE X-RAY IMAGING DEVICE, DIGIITAL FLAT PANEL X-RAY DETECTOR, 1417WCC | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| July 16, 2014 | K141563 | SOLID STATE X-RAY IMAGING DEVICE, DIGITAL FLAT PANEL X-RAY DETECTOR, 1417WGC | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| May 13, 2014 | K140060 | DIGITAL DENTAL INTRA ORAL SENSOR, HDI 2000, HDI 2000A | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| May 13, 2014 | K140056 | DIGITAL DENTAL INTRA ORAL SENSOR; HDI 1000, HDI 1000A | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| April 11, 2014 | K140646 | DIGITAL FLAT PANEL X-RAY DETECTOR / 1717G, XMARU1717G | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| February 21, 2014 | K133409 | DIGITAL FLAT PANEL X-RAY DETECTOR/ 910SGA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| September 17, 2013 | K131114 | DIGITAL FLAT PANEL X-RAY DETECTOR | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| July 2, 2013 | K130935 | DIGITAL FLAT PANEL X-RAY DETECTOR/1417WCA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| March 12, 2013 | K123345 | DIGITAL FLAT PANEL X-RAY DETECTOR / 1012WCA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| January 30, 2013 | K122928 | DIGITAL FLAT PANEL X-RAY DETECTOR/1417PGA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| January 1, 2013 | K122919 | DIGITAL FLAT PANEL X-RAY DETECTOR11417PCA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| October 19, 2012 | K122173 | DIGITAL FLAT PLANEL X-RAY DETECTOR / 1717SCC | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| August 16, 2012 | K122182 | DIGITAL FLAT PANEL X-RAY DETECTOR/1717SGC | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| May 10, 2012 | K121132 | EZSENSOR P DIGITAL INTRAORAL SENSOR | MQB | Substantially Equivalent | Humanray Co,Ltd | accessdata.fda.gov |
| December 29, 2011 | K113630 | DIGITAL FLAT PANEL X-RAY DETECTOR/1210SGA | MQB | Substantially Equivalent | Rayence Co., Ltd. | accessdata.fda.gov |
| December 2, 2009 | K090526 | MEDICAL IMAGE PROCESSING UNIT, MODEL EZSENSOR | MUH | Substantially Equivalent | E-Woo Technology | accessdata.fda.gov |
Compare with other makers
- All makers of Solid State X-Ray Imager (Flat Panel/Digital Imager)
- All makers of System, X-Ray, Fluoroscopic, Image-Intensified
- All makers of System, X-Ray, Extraoral Source, Digital
- All makers of Full Field Digital, System, X-Ray, Mammographic
- All makers of System, Image Processing, Radiological
Updated July 31, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.