Data / Medical devices / United States / Q'apel Medical, Inc.
Q'apel Medical, Inc.: FDA-registered device maker in Fremont, CA, United States, 5 510(k) clearances
Q'apel Medical, Inc. is registered with the FDA (registration 3020954126) in Fremont, CA, United States. It lists 3 device types. The FDA files 5 510(k) clearances under its listings, the newest dated May 7, 2026. 1 recall event names it as the recalling firm (1 Class I). Registered through 2026. FDA data exported November 3, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3020954126
- Address
- 4245 Technology Drive, Fremont, CA, United States, 94538
- Owner or operator
- Q'Apel Medical Inc. (10058467)
- Roles
- Manufacturer
- First device listed
- August 9, 2019
- Registered through
- 2026
- Brand names listed
- 087 Balloon Guide Catheter System, Armadillo, Lynx Aspiration Catheter System, Neurovascular Access System Family, SelectFlex Neurovascular Access System Family, Walrus, Zebra
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Catheter, Percutaneous | DQY | 2 | Manufacturer | accessdata.fda.gov |
| Catheter, Percutaneous, Neurovasculature | QJP | 2 | Manufacturer | accessdata.fda.gov |
| Catheter, Thrombus Retriever | NRY | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 7, 2026 | K254276 | Lynx Aspiration Catheter System | NRY | Substantially Equivalent | QApel Medical, Inc. | accessdata.fda.gov |
| November 20, 2024 | K240746 | Neurovascular Access System Family | QJP | Substantially Equivalent | Q'Apel Medical, Inc. | accessdata.fda.gov |
| August 5, 2021 | K211893 | SelectFlex Neurovascular Access System Family | QJP | Substantially Equivalent | Q'Apel Medical, Inc. | accessdata.fda.gov |
| October 31, 2019 | K192525 | 087 Balloon Guide Catheter System | DQY | Substantially Equivalent | Q'Apel Medical, LLC | accessdata.fda.gov |
| July 15, 2019 | K190749 | 087 Balloon Guide Catheter System | DQY | Substantially Equivalent | Q'Apel | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| February 26, 2025 | 96492 | Class I | Ongoing | Hippo 072 Aspiration System including Cheetah Delivery Tool and Aspiration Tubing, REF: APT6072-132. Hippo 072 Aspiration System including Cheetah Delivery Tool, REF: AP6072-132. 072 Aspiration Tubing, REF: APT-95 | Aspiration catheter distal tip features and characteristics may not be in the scope of FDA clearance; tip detachment, vessel rupture, and vasospasm could occur. | accessdata.fda.gov |
Compare with other makers
- All makers of Catheter, Percutaneous
- All makers of Catheter, Percutaneous, Neurovasculature
- All makers of Catheter, Thrombus Retriever
Updated May 7, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.