Data / Medical devices / United States / Puritan Medical Products Company LLC
Puritan Medical Products Company LLC: FDA-registered device maker in Guilford, ME, United States, 5 510(k) clearances
Puritan Medical Products Company LLC is registered with the FDA (registration 1216735) in Guilford, ME, United States. It lists 14 device types. The FDA files 5 510(k) clearances under its listings, the newest dated May 27, 2025. 2 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1216735
- Address
- 31 School St, Guilford, ME, United States, 04443
- Owner or operator
- HARDWOOD PRODUCTS COMPANY LP (1216735)
- Roles
- Contract manufacturer, Manufacturer, Repackager or relabeler, Specification developer
- First device listed
- March 23, 1978
- Registered through
- 2026
- Brand names listed
- Brightwood, CaligSwab, Hospital, HydraFlock, Opti-Swab, Opti-Tranz, PurFlock Ultra, PurSwab and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 27, 2025 | K242820 | Puritan PurSafe Plus Collection and Transport System | QBD | Substantially Equivalent | Puritan Medical Products, LLC | accessdata.fda.gov |
| November 4, 2016 | K162284 | Puritan Fecal Opti-Swab Collection and Transport System | JSM | Substantially Equivalent | Puritan Medical Products, LLC | accessdata.fda.gov |
| June 8, 2012 | K120846 | TRANSPORT CULTURE MEDIUM DEVICE | LIO | Substantially Equivalent | Puritan Medical Products, LLC | accessdata.fda.gov |
| March 1, 2012 | K113249 | TRANSPORT CULTURE MEDIUM DEVICE | JSM | Substantially Equivalent | Puritan Medical Products, LLC | accessdata.fda.gov |
| January 19, 2012 | K111681 | HISTOBRUSH | HHT | Substantially Equivalent | Puritan Medical Products Company, LLC | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| February 21, 2024 | 94087 | Class II | Ongoing | HydroFlock Sterile Flocked Collection Device, Part Number 25-3317-H. | It was discovered through a customer complaint that mislabeled product was distributed. Puritan distributed product labelled as 25-3317-H lot S1014 which contained product code 25-3317-U in all packages. | accessdata.fda.gov |
| December 22, 2014 | 70270 | Class II | Terminated | Puritan absorbent foam tipped applicator; Catalog Number 25-1406 1 PF BT. Sterile absorbent foam tipped applicator used to apply medication or to obtain specimens from a patient. | Shaft breaks so that adequate patient specimen sample cannot be obtained. | accessdata.fda.gov |
Compare with other makers
- All makers of Tape, Measuring, Rulers And Calipers
- All makers of Device, Specimen Collection
- All makers of Transport Systems, Anaerobic
- All makers of System, Transport, Aerobic
- All makers of Culture Media, Non-Propagating Transport
- All makers of Culture Media, Selective And Non-Differential
Updated May 27, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.