Data / Medical devices / Germany / PTW Freiburg

PTW Freiburg: FDA-registered device maker in FREIBURG Baden-Wurttemberg, Germany, 11 510(k) clearances

PTW Freiburg is registered with the FDA (registration 9681124) in FREIBURG Baden-Wurttemberg, Germany. It lists 5 device types. The FDA files 11 510(k) clearances under its listings, the newest dated April 15, 2026. 4 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
9681124
FEI number
3007360740
Address
Loerracher Strasse 7, FREIBURG Baden-Wurttemberg, Germany, D-79115
Owner or operator
PTW Freiburg (9010117)
Roles
Manufacturer
First device listed
April 5, 1994
Registered through
2026
Brand names listed
Absorber (multiple), Acrylic/RW3 slab phantoms and plates, multiple, Advanced Markus chamber, BEAMSCAN, BEAMSCAN MR, BQ-CHECK, BeamAdjust, Bragg peak chamber and more

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
April 15, 2026K252258VERIQA RT EPID 3DIYESubstantially EquivalentPtw-Freiburg Physikalisch-Technische-Werkstaetten Dr. Pychlaaccessdata.fda.gov
March 30, 2022K213370VERIQAIYESubstantially EquivalentPtw-Freiburg Physikalisch-Technische-Werkstaettenaccessdata.fda.gov
February 21, 2020K191646Beamscan MRIYESubstantially EquivalentPtw-Freiburg Physikalisch-Technische-Werkstaettenaccessdata.fda.gov
October 20, 2017K160405OCTAVIUS I, OCTAVIUS II, OCTAVIUS III, OCTAVIUS 4DIYESubstantially EquivalentPtw-Freiburg Physikalisch-Technische-Werkstaettenaccessdata.fda.gov
May 19, 2017K161807BEAMSCANIYESubstantially EquivalentPtw-Freiburg Physikalisch Technische-Werksraettenaccessdata.fda.gov
June 20, 2001K010916PTW DOSIMETRY DIODE, T60008IYESubstantially EquivalentPtw-New York Corp.accessdata.fda.gov
September 10, 1997K9722120.015CC PINPOINT IONIZATION CHAMBER, 0.005 CC PINPOINT IONIZATION CHAMBERLHNSubstantially EquivalentPtw-New York Corp.accessdata.fda.gov
September 10, 1997K972211MULTIDOS, QC6PLUSLHNSubstantially EquivalentPtw-New York Corp.accessdata.fda.gov
June 17, 1996K9612080.6CC IONIZATION CHAMBER - WATERPROOF 0.6CC IONIZATION CHAMBERIYESubstantially EquivalentPtw-New York Corp.accessdata.fda.gov
December 5, 1995K954165PTW-MP3 & PTW-MP3S AUTOMATIC WATER PHANTOMIYESubstantially EquivalentPtw-New York Corp.accessdata.fda.gov
October 7, 1995K951764UNIDOS UNIVERSAL DOSIMETER MODEL 10002-WITH TNC CONNECTOR, 10005-WITH BNT CONNECTORIYESubstantially EquivalentPtw-New York Corp.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
August 4, 202699720Class IIOngoingBrand Name: VERIQA; Product Name: RT MonteCarlo 3D v3; Model/Catalog Number: S070031.520; Software Version: 3.1.18When a bolus is included in a treatment plan and sent for secondary dose calculation, the software accounts for it but does not display this clearly, which may lead users to incorrectly omit the bolus during treatment and deliver the prescribed dose to the wrong tissue depth.accessdata.fda.gov
February 8, 202493988Class IIOngoingSoftware VERIQA (S070031), version 2.0 and 2.1- Software package for display, evaluation and digital processing of medical image data sets and treatment plans in radiation oncology.Software: If the user excludes voxels from the Gamma calculation that are below a dose threshold (Suppress gamma calculation), the Gamma Passing Rate (GPR) calculated for individual ROIs is not correct. The GPR calculated by VERIQA overestimates the correct GPR. The evaluation can therefore show false positive results.accessdata.fda.gov
June 7, 202392879Class IIOngoingBeamAdjust software Version 2.3.3 Ref: S080032 The following devices are affected when a relative calibration is performed using ArrayCal (module from BeamAdjust S080032, UDI-DI: EPTWS0800320 ): " OCTAVIUS Detector 1600 Generated calibration file will not be correct in case of a relative calibration of an OCTAVIUS Detector 1000 or OCTAVIUS Detector 1600, if a Tiff file or a DICOM data set is used as reference matrix. Therefore, the measurement result will be incorrect by using such a calibration file.accessdata.fda.gov
May 27, 201571395Class IITerminatedPTW UNIDOS webline: 1) REF T10023, 2) REF T10022 and 3) REF T10023 Firmware version 2.05. Dosimeter for radiation therapy, diagnostic radiology and health physics.In some cases, especially with high dose-per-pulse-rates typical for particle (specifically proton) therapy, measuring errors can result. Individual measurement intervals can be lost that are not visible to the user when there is a high dose-per-pulse rate resulting in a too-low dose being displayed on the monitor. This could result in a radiation over-exposaccessdata.fda.gov

Compare with other makers

Updated September 15, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.