Skip to the page

Data / Medical devices / United States / Polymer Technology Systems

Polymer Technology Systems: FDA-registered device maker in Whitestown, IN, United States, 20 510(k) clearances

Polymer Technology Systems is registered with the FDA (registration 3015525148) in Whitestown, IN, United States. It lists 11 device types. The FDA files 20 510(k) clearances under its listings, the newest dated February 26, 2022. 17 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3015525148
FEI number
3002698769
Address
4600 Anson Boulevard, Whitestown, IN, United States, 46075
Owner or operator
POLYMER TECHNOLOGY SYSTEMS, INC. (9031081)
Roles
Complaint file establishment, Manufacturer
First device listed
December 12, 2005
Registered through
2026
Brand names listed
A1CNow Self Check, A1CNow+ Professional Use, A1CNow+ Professional Use (A1CNow+ Monitor; A1CNow+ Test Cartridge; A1CNow+ Dilution Kit), CVS Health At Home A1C Test Kit, CardioChek +, CardioChek Analyzer, CardioChek ChekMate, CardioChek ChekMate Strips and more

Devices it lists

DeviceProduct codeClassRoleSource
Assay, Glycosylated HemoglobinLCP2Manufactureraccessdata.fda.gov
Colorimetric Method, TriglyceridesJGY1Complaint file establishment, Manufactureraccessdata.fda.gov
Enzymatic Esterase--Oxidase, CholesterolCHH1Complaint file establishment, Manufactureraccessdata.fda.gov
Glucose Oxidase, GlucoseCGA2Manufactureraccessdata.fda.gov
Ldl & Vldl Precipitation, HdlLBR1Complaint file establishment, Manufactureraccessdata.fda.gov
Lipoprotein, High Density, Hdl, Over The CounterNAQ1Manufactureraccessdata.fda.gov
Medical Device Data SystemOUG1Manufactureraccessdata.fda.gov
Multi-Analyte Controls, All Kinds (Assayed)JJY1Manufactureraccessdata.fda.gov
System, Test, Blood Glucose, Over The CounterNBW2Manufactureraccessdata.fda.gov
Test, Triglycerides, Over The CounterNGO1Manufactureraccessdata.fda.gov
Tube, Collection, Capillary BloodGIO1Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
February 26, 2022K193406CardioChek Plus Test System; CardioChek Plus Home Test SystemNBWSubstantially EquivalentPolymer Technology Systems, Inc. D/B/A Pts Diagnosticsaccessdata.fda.gov
December 22, 2016K162282CardioChek Plus Test System, CardioChek Home Test SystemCGASubstantially EquivalentPolymer Technology Systems, Inc. D/B/A Pts Diagnosticsaccessdata.fda.gov
December 22, 2016K151545CardioChek Plus Test System, CardioChek Home Test System, CardioChek PA Test System, CardioChek PA Home Test SystemCHHSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
July 7, 2015K151530CardioChek Plus Test SystemCGASubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
May 22, 2015K140068CARDIOCHEK PLUS TEST SYSTEM, CARDIOCHEK HOME TEST SYSTEMNBWSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
May 14, 2009K090413A1CNOW+ (10 TEST KIT, PROFESSIONAL USE) MODEL 3024, A1CNOW+(20 TEST KIT, PROFESSIONAL USE) MODEL 3021, A1CNOW SELF CHECLCPSubstantially EquivalentBayer Healthcare, LLCaccessdata.fda.gov
October 15, 2007K071593PTS PANELS CHOL+HDL PANEL TEST STRIPSCHHSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
September 10, 2007K071507PTS PANELS CHOL+HDL+GLU PANEL TEST STRIPSNBWSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
January 31, 2007K070017PTS PANELS METABOLIC CHEMISTRY PANEL TEST STRIPSNBWSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
April 5, 2006K060617PTS PANELS HDL CHOLESTEROL TEST STRIPSNAQSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
July 23, 2004K041750PTS PANELS CHOL+GLU TEST PANELNBWSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
November 15, 2002K023558PTS PANELS LIPID PANEL TEST STRIPSCHHSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
September 24, 2002K022898PTS PANELS LIPID PANEL TEST STRIPSCHHSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
August 21, 2002K022401PTS PANELS MULTI-CHEMISTRY CONTROLSJJYSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
December 21, 2001K014099BIOSCANNER PLUSNBWSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
November 20, 2001K013068BIOSCANNER 2000CGASubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
July 3, 2000K000586BIOSCANNER TRIGLYCERIDES TEST STRIPSJGYSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
May 24, 2000K991894BIOSCANNER TRIGLYCERIDES TEST STRIPSJGYSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
June 24, 1999K990688MTM BIOSCANNER C TEST STRIPSCHHSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov
July 22, 1998K981493MTM BIOSCANNER C TEST STRIPS MODEL NUMBER BSA 200, BSA 210, BSA 220CHHSubstantially EquivalentPolymer Technology Systems, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
September 18, 202495416Class IICompletedA1CNow+ Multi-Test HbA1c System consists of (1) a semi-disposable plastic-encased device (the monitor), (2) a plastic cartridge enclosing dry reagent strips, and (3) a sample dilution kit for: collecting the blood sampleThe reason for this recall is PTS Diagnostics, Inc. received complaints of non-matching cartridge and analyzer codes within the product test system box. Use of cartridges and analyzers with non-matching codes may result in inaccurate test results as components within each lot number are meant to be used together, and not mixed between lots. Therefore, the teaccessdata.fda.gov
August 16, 202290791Class IIICompletedPTS Panels CHOL+GLU Test Strips (REF 1765)Incorrect instructions for use were packaged into the final product.accessdata.fda.gov
January 21, 202084840Class IITerminatedPTS Detect Cotinine, Ref. No. 3061, UPC 381933061017 in vitro diagnostic - Product Usage: The PTS Detect cotinine system provides quantitative measurement of the nicotine metabolite cotinine (25 200 ng/mL) in capillary (The firm is removing the product from the market after discussions with the FDA due to lack of 510(k) clearance.accessdata.fda.gov
December 2, 201984274Class IITerminatedPTS Diagnostics CardioChek Plus Professional Analyzer, New analyzer, boxed, with carrying case, Reference Numbers 2700One brand of batteries have a small dimensional difference in the negative button terminal, which, when the batteries are inserted incorrectly, can create the possibility for the battery terminals to make reverse contact. This reverse contact can cause a potential for overheating.accessdata.fda.gov
June 7, 201983097Class IIITerminatedPTS Panels Lipid Panel test strip: IVD Lipid Panel Test Strips Ref Number: 1710 Product Usage: PTS Panels Lipid Panel test strips measure total cholesterol, HDL (high density lipoprotein) cholesterol, and triglycerides iThe MEMo chips provided with lot P901 may be mislabeled, the MEMo Chip may display Q901 on the analyzer LCD screen, instead of P901accessdata.fda.gov
January 16, 201982331Class IITerminatedLipid Panel test strips, REF 1710, also private labeled under Henry Schein as REFSome lots of test strips do not fit tightly into the optical block, and may fall out during analysis, which could lead to an incorrect result being displayed.accessdata.fda.gov
March 14, 201879778Class IITerminatedPTS Panels CHOL+GLU Test Strips (REF 1765)Potential for loss of activity of the glucose analyte (under-recovery) prior to the full stated shelf life (August 2018)accessdata.fda.gov
December 2, 201684231Class IITerminatedA1CNow+ Systems (professional use product), Software Version Revision D, REF Numbers US: 3021, 3024; EU: 3037, 3038, 3057, 3058A numerical value less than 4% or greater than 13% may be displayed instead of the expected <4% or >13% result, due to a software bug.accessdata.fda.gov
March 15, 201684264Class IITerminatedPTS Panels CHOL+HDL+GLU Test Strips, Reference Number 5412, for use on CardioChek PA or CardioChek Plus analyzersThis lot of test strips is showing an under-recovery when tested against a reference method.accessdata.fda.gov
April 4, 201365067Class IITerminatedPTS PANELS, Glucose Test Strips for use with CardioChek Brand Analyzers Product Usage: used by healthcare professionals and individuals with diabetes to measure glucose in whole bloodInternal investigation demonstrated under-recovery for glucose when tested against a reference method. This could result in a low to moderate health risk.accessdata.fda.gov
May 15, 201261966Class IITerminatedPTS Panels Creatinine test strips. PTS Panels Creatinine Test Strips are intended to measure creatinine in whole blood. Creatinine measurements are used in the diagnosis and treatment of renal (kidney) diseases and in thDuring a routine product investigation, a creatinine sample with a value less than 1.0 mg/dl was tested on a version 2.60 CardioCek PA meter and the meter provided a result of 0.08mg/dl, which is not the reportable measuring range for the CardioChek PA meter for the creatinine assay.accessdata.fda.gov
July 6, 201056188Not yet classifiedTerminatedPTS Panels Test Strips, CHOL +HDL+GLU Panel for CardioChek PA brand analyzers, 15 tests 1 MEMo Chip, manufacturer Polymer Technology Systems, Inc., 7736 Zionsville Rd., Indianapolis, IN 46268.The test strips appear to under-recover Cholesterol, HDL and glucose.accessdata.fda.gov
August 4, 200953246Not yet classifiedTerminatedPTS Panels CHOL+HDL+GLU Panel test strips for professional use with CardioChek P-A analyzers, Manufactured by Polymer Technology Systems, Inc., Indianapolis, IN.Possible under recovery of cholesterol, HDL and glucose. A loss of recoverable cholesterol and HDL cholesterol is a manageable to moderate health risk. The clinical applications analysis shows that lot 1891 shows such a loss of activity. A loss of recoverable Glucose measurement is a moderate to high risk, based upon the degree of under-recovery, and the freaccessdata.fda.gov
June 5, 200953773Not yet classifiedTerminatedPTS Panels Lipids Panel test strips for self-testing or professional use with CardioChek P-A analyzers, Manufactured by Polymer Technology Systems, Inc. Catalog # 1710.Exhibits under-recovery of all analytes.accessdata.fda.gov
April 2, 200953768Not yet classifiedTerminatedPTS Panels Cholesterol test strips for self-testing or professional use with CardioChek analyzers, Manufactured by Polymer Technology Systems, Inc., Indianapolis, IN.Catalog # 1711. Intended to provide a quantitative meaThe memory chip was coded with incorrect product information.accessdata.fda.gov
February 20, 200953761Not yet classifiedTerminatedPTS Panels CHOL+HDL Panel test strips for professional use with CardioChek P-A analyzer, Manufactured by Polymer Technology Systems, Inc., Indianapolis, IN.Catalog # 1795. The product is used to measure total cholesterolExtended expiration date; the product expired on February 12, 2009 but was labeled with a April 4, 2009 expiration date.accessdata.fda.gov
May 29, 200853759Not yet classifiedTerminatedPTS Panels LDL Cholesterol test strips for professional use with CardioChek P-A test systems, Manufactured by Polymer Technology Systems, Inc., Indianapolis, IN; Catalog No. 1753. For the quantitative measurement of LDL The expiration date was extended by 20 weeks without justification.accessdata.fda.gov

Compare with other makers

Updated October 24, 2024. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.