Data / Medical devices / United States / Pivotal Health Solutions
Pivotal Health Solutions: FDA-registered device maker in Watertown, SD, United States, 3 510(k) clearances
Pivotal Health Solutions is registered with the FDA (registration 3007278668) in Watertown, SD, United States. It lists 13 device types. The FDA files 3 510(k) clearances under its listings, the newest dated September 10, 2014. 3 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3007278668
- Address
- 3003 9th Ave. SW, Watertown, SD, United States, 57201
- Owner or operator
- Pivotal Health Solutions, Inc. (10030456)
- Roles
- Complaint file establishment, Manufacturer
- First device listed
- October 6, 2009
- Registered through
- 2026
- Brand names listed
- Electric Parallel Bars, Parallel bars, Portable Parallel Bars
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| September 10, 2014 | K131983 | ITRAC CERVICAL TRACTION SYSTEM | ITH | Substantially Equivalent | Pivotal Health Solutions | accessdata.fda.gov |
| August 27, 2010 | K101889 | DECOMPRESSION OF CHOICE AND NEURO DECOMPRESSION DEVICE | ITH | Substantially Equivalent | Pivotal Health Solutions | accessdata.fda.gov |
| March 21, 2006 | K060134 | APOLLO IR HEAT LAMP SYSTEM | ILY | Substantially Equivalent | Apollo Physical Therapy Products International | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| October 9, 2025 | 97861 | Class II | Ongoing | Quantum Intersegmental Table, Model/Catalog Number: Q400; heated massage table | The heat function may become damaged over time due to patients pressing on the areas with heat function components. Damage to components can lead to overheating which can lead to smoldering and melting of the vinyl cushion. | accessdata.fda.gov |
| April 29, 2024 | 94815 | Class II | Ongoing | Decompression Table Model E9011. This device applies cervical and/or lumbar decompression with practitioner definable target treatment location, treatment pounds, and patterns of treatment. | This product is being recalled due to potentially insufficient rework on a part (E7130-B) on the lumbar section of the frame on 6 distributed tables. There were 4 additional tables with the faulty E7130-B part that were manufactured, but had not been distributed yet. | accessdata.fda.gov |
| December 17, 2014 | 70473 | Class II | Terminated | Apollo (cold) Laser Desktop Control Units, Model AP2-DT. The Apollo IR Heat Lamp System is intended to emit energy in the infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for t | Control units were equipped with an internal mounting kit that does not meet medical safety standards, and are conductive, increasing the risk of electric shock to the user and patient. These units were manufactured prior to Pivotal Health Solutions acquisition of the Apollo product line. | accessdata.fda.gov |
Compare with other makers
- All makers of Table, Mechanical
- All makers of Chair And Table, Medical
- All makers of Massager, Therapeutic, Electric
- All makers of Bars, Parallel, Exercise
- All makers of Table, Powered
- All makers of Lamp, Infrared, Therapeutic Heating
Updated November 24, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.