Data / Medical devices / Netherlands / Pie Medical Imaging B.V.
Pie Medical Imaging B.V.: FDA-registered device maker in MAASTRICHT Limburg, Netherlands, 10 510(k) clearances
Pie Medical Imaging B.V. is registered with the FDA (registration 9710122) in MAASTRICHT Limburg, Netherlands. It lists 4 device types. The FDA files 10 510(k) clearances under its listings, the newest dated November 3, 2025. 2 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 9710122
- FEI number
- 3003595527
- Address
- Demertdwarsstraat 8A01, MAASTRICHT Limburg, Netherlands, 6227 AK
- Owner or operator
- Pie Medical Imaging B.V. (9045579)
- Roles
- Manufacturer
- First device listed
- November 19, 2007
- Registered through
- 2026
- Brand names listed
- 3mensio Structural Heart, 3mensio Vascular, 3mensio Workstation, CAAS MR Solutions, CAAS QCA 3D, CAAS QVA 3D, CAAS Workstation, CAAS, CAASII, CAAS2000 and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Automated Radiological Image Processing Software | QIH | 2 | Manufacturer | accessdata.fda.gov |
| System, Image Processing, Radiological | LLZ | 2 | Manufacturer | accessdata.fda.gov |
| System, X-Ray, Angiographic | IZI | 2 | Manufacturer | accessdata.fda.gov |
| X-Ray Angiographic Imaging Based Coronary Vascular Simulation Software Device | QHA | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| November 3, 2025 | K250330 | 3mensio Workstation | QIH | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| April 9, 2024 | K232147 | CAAS Workstation | QHA | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| February 1, 2024 | K232007 | CAAS MR Solutions | LLZ | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| May 16, 2022 | K212376 | Caas Qardia | LLZ | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| December 4, 2018 | K181825 | CAAS MR Solutions | LLZ | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| May 3, 2018 | K180019 | CAAS Workstation | IZI | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| May 27, 2016 | K153736 | 3mensio Workstation | LLZ | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| March 11, 2016 | K151780 | CAAS Workstation | IZI | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| April 30, 2010 | K100292 | CAAS QVA 3D, CAAS QCA 3D | LLZ | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
| December 30, 2005 | K052988 | CAAS | LLZ | Substantially Equivalent | Pie Medical Imaging BV | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| May 7, 2026 | 98930 | Class II | Ongoing | 3mensio Workstation (Vascular Fenestrated) software | User measurement value reported by diagnostic bioimaging software intended to measure/visualize cardiovascular structures may be larger (0.8% to 34.4%) than the actual anatomical dimension, if all the following occur: affected software is used, and the user has access only to 3D Echo OR Mitral 3D Echo, and the dataset being analyzed is a Philips 3D echo data | accessdata.fda.gov |
| July 14, 2025 | 97307 | Class II | Ongoing | 3mensio Workstation (Vascular Fenestrated) software | When fenestrated analysis with clock measurements is started in diagnostic bioimaging software (intended to measure/visualize cardiovascular structures) and the 12h position of a single clock is changed, other clock measurements are not updated relative to the new 12h position which may cause stent graft fenestrations at incorrect position, which may lead to | accessdata.fda.gov |
Compare with other makers
- All makers of System, Image Processing, Radiological
- All makers of Automated Radiological Image Processing Software
- All makers of System, X-Ray, Angiographic
- All makers of X-Ray Angiographic Imaging Based Coronary Vascular Simulation Software Device
Updated July 21, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.