Skip to the page

Data / Medical devices / Netherlands / Philips Medical Systems Nederland B.V.

Philips Medical Systems Nederland B.V.: FDA-registered device maker in BEST Noord-Brabant, Netherlands, 17 510(k) clearances

Philips Medical Systems Nederland B.V. is registered with the FDA (registration 3003768277) in BEST Noord-Brabant, Netherlands. It lists 36 device types. The FDA files 17 510(k) clearances under its listings, the newest dated March 3, 2022. 54 recall events name it as the recalling firm (1 Class I). Registered through 2026. FDA data exported November 3, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3003768277
FEI number
3002807880
Address
Veenpluis 6, BEST Noord-Brabant, Netherlands, 5684 PC
Owner or operator
Philips Medical Systems International BV (1217116)
Roles
Contract manufacturer, Exporter to the US, Remanufacturer
First device listed
March 30, 1978
Registered through
2026
Brand names listed
001014 - 2D Quantitative Analysis, 1.5 T eCoil Imaging System for Philips, 3D Roadmap Rel. 1, 3D-CA, 3D-RA, ADVANCED FILTER ECG CABLE - 989803170121, ALLURACLARITY XPER FD SERIES X-RAY SYSTEM, ANTERIOR - SYN HEAD/NECK COIL 4598-000-5192x and more

Devices it lists

DeviceProduct codeClassRoleSource
Accelerator, Linear, MedicalIYE2Exporter to the USaccessdata.fda.gov
Assembly, Tube Housing, X-Ray, DiagnosticITY1Exporter to the USaccessdata.fda.gov
Automated Radiological Image Processing SoftwareQIH2Contract manufactureraccessdata.fda.gov
Coil, Magnetic Resonance, SpecialtyMOS2Exporter to the USaccessdata.fda.gov
Collimator, Automatic, RadiographicIZW2Contract manufactureraccessdata.fda.gov
Collimator, Manual, RadiographicIZX2Contract manufactureraccessdata.fda.gov
Computer, Diagnostic, ProgrammableDQK2Contract manufacturer, Exporter to the USaccessdata.fda.gov
Device, Medical Examination, Ac PoweredKZF1Exporter to the USaccessdata.fda.gov
Generator, High-Voltage, X-Ray, DiagnosticIZO1Exporter to the USaccessdata.fda.gov
Grid, RadiographicIXJ1Contract manufactureraccessdata.fda.gov
Holder, Head, Neurosurgical (Skull Clamp)HBL2Exporter to the USaccessdata.fda.gov
Holder, Head, RadiographicIWY1Exporter to the USaccessdata.fda.gov
Image-Intensified Fluoroscopic X-Ray System, MobileOXO2Contract manufactureraccessdata.fda.gov
Injector And Syringe, AngiographicDXT2Exporter to the USaccessdata.fda.gov
Instrument, Quality-Assurance, RadiologicLHO1Contract manufacturer, Exporter to the USaccessdata.fda.gov
Interventional Fluoroscopic X-Ray SystemOWB2Contract manufacturer, Remanufactureraccessdata.fda.gov
Monitor, Patient Position, Light-BeamIWE1Exporter to the USaccessdata.fda.gov
Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)MWI2Contract manufacturer, Exporter to the USaccessdata.fda.gov
Set, I.V. Fluid TransferLHI2Contract manufactureraccessdata.fda.gov
Shield, Protective, PersonnelKPY1Exporter to the USaccessdata.fda.gov
Solid State X-Ray Imager (Flat Panel/Digital Imager)MQB2Contract manufactureraccessdata.fda.gov
System, Image Processing, RadiologicalLLZ2Contract manufactureraccessdata.fda.gov
System, Nuclear Magnetic Resonance ImagingLNH2Contract manufacturer, Exporter to the USaccessdata.fda.gov
System, Nuclear Magnetic Resonance SpectroscopicLNI2Contract manufactureraccessdata.fda.gov
System, Planning, Radiation Therapy TreatmentMUJ2Contract manufactureraccessdata.fda.gov
System, X-Ray, AngiographicIZI2Contract manufactureraccessdata.fda.gov
System, X-Ray, Fluoroscopic, Image-IntensifiedJAA2Contract manufactureraccessdata.fda.gov
System, X-Ray, StationaryKPR2Contract manufactureraccessdata.fda.gov
System, X-Ray, Tomography, ComputedJAK2Contract manufactureraccessdata.fda.gov
Table, Operating-Room, Ac-PoweredFQO1Exporter to the USaccessdata.fda.gov
Table, Radiographic, Non-Tilting, PoweredIZZ2Contract manufactureraccessdata.fda.gov
Table, Radiographic, Stationary TopIXQ2Contract manufactureraccessdata.fda.gov
Table, RadiologicKXJ2Contract manufactureraccessdata.fda.gov
Test-Pattern, RadiographicIXF1Exporter to the USaccessdata.fda.gov
Tube Mount, X-Ray, DiagnosticIYB1Contract manufactureraccessdata.fda.gov
Wire, Guide, CatheterDQX2Contract manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
March 3, 2022K211658OR Head Holder LUCY with HeadCoilSet Siemens 1.5T, OR Head Holder LUCY with HeadCoilSet Siemens 3T, OR Head Holder LUCY with HeadCoilSet Philips 1.5T, OR Head Holder LUCY with HeadCoilSet Philips 3TMOSSubstantially EquivalentNoras Mri Products GmbHaccessdata.fda.gov
July 10, 2020K201389Resoundant Acoustic Driver SystemLNHSubstantially EquivalentResoundant, Inc.accessdata.fda.gov
September 14, 2018K173926DORADOnova MR3TIYESubstantially EquivalentLap GmbH Laser Applikationenaccessdata.fda.gov
March 21, 2018K163661P-140-Flex Coil, Na-140-Flex Coil, C-140-Flex CoilMOSSubstantially EquivalentRapid Biomedical GmbHaccessdata.fda.gov
August 6, 2014K133506NORAS OR HEAD HOLDER FLEXIBILITYMOSSubstantially EquivalentNoras Mri Products GmbHaccessdata.fda.gov
July 15, 2013K131382EXPRESSION MR200 MRI PATIENT MONITORING SYSTEM, EXPRESSION IP5 INFORMATION PORTALMWISubstantially EquivalentInvivo Corporationaccessdata.fda.gov
June 28, 2013K130638ALLURACLARITY XPER FD SERIES X-RAY SYSTEMOWBSubstantially EquivalentPhilips Medical Systems Nederland B.V.accessdata.fda.gov
October 26, 2010K101571XPER INFORMATION MANAGEMENT AND FLEX CARDIO PHYSIOMONITORING SYSTEMSMWISubstantially EquivalentWitt Biomedical Corpaccessdata.fda.gov
July 28, 2010K101949PEDIATRIC BODY-CARDIAC COIL, MODEL: 5000012601MOSSubstantially EquivalentShanghai Chenguang Medical Technologies Co, Ltd.accessdata.fda.gov
July 14, 2010K101858PEDIATRIC HEAD-SPINE COIL (MODEL:5000012701MOSSubstantially EquivalentShanghai Chenguang Medical Technologies Co, Ltd.accessdata.fda.gov
December 15, 2009K090785MRI COMPATIBLE PATIENT MONITORING SYSTEM, MODEL 865214MWISubstantially EquivalentInvivo Corp.accessdata.fda.gov
July 21, 2008K081218BELLYSTEP, HEADSTEP, BREASTSTEP, PROSTEP, WINGSTEP AND ICASTIYESubstantially EquivalentIt-V Medizintechnik, GmbHaccessdata.fda.gov
June 18, 2008K081340PEDIATRIC BODY AND CARDIAC COIL, MODEL 01000140201MOSSubstantially EquivalentShanghai Chenguang Medical Technologies Co, Ltd.accessdata.fda.gov
June 18, 2008K081322MAGNETIC RESONANCE DIAGNOSTIC DEVICE, MODEL 0100140201, PEDIATRIC HEAD-SPINE COILMOSSubstantially EquivalentShanghai Chenguang Medical Technologies Co, Ltd.accessdata.fda.gov
July 23, 2007K071847MAGNETIC RESONANCE DIAGNOSTIC DEVICE, MODEL CG-KFC18-H150-AP - KNEE/FOOT/ANKLE COILMOSSubstantially EquivalentShanghai Chenguang Medical Technologies Co, Ltd.accessdata.fda.gov
November 30, 2006K063342MEDRAD ECOIL IMAGING SYSTEM FOR PHILIPSMOSSubstantially EquivalentMedrad, Inc.accessdata.fda.gov
September 26, 1990K903390MEDRAD MARK V-PLUS INJECTORDXTSubstantially EquivalentMedrad, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
May 18, 202699223Class IIOngoingPhilips MultiDiagnost Eleva with the following Model Numbers: Model # 708032 for MultiDiagnost Eleva; Model # 708034 for MultiDiagnost Eleva with Flat Detector; Model # 708036 for MultiDiagnost Eleva; Model # 708037 for Philips Allura Xper and MultiDiagnost-Eleva systems Hand switch button not fully releasing potentially leading to loss of imaging functionality or unintended radiation exposure and additional contrast injectionaccessdata.fda.gov
March 19, 202698576Class IIOngoingPhilips AneurysmFlow. Model Number: 001015. AneurysmFlow is a software medical device (Interventional Tool) intended to be used in combination with a Philips interventional X-ray system and 3DRA data.Potential safety issue involving the Mean Aneurysm Flow Amplitude (MAFA) ratio of AneurysmFlow (Interventional Tool). Philips has determined that the MAFA ratio does not provide reliable prognostic information regarding aneurysm occlusion following Flow Diverter Stent treatment, however despite being stated in the IUF, it is being relied on for making clinicaccessdata.fda.gov
March 5, 202698520Class IIOngoingVue Motion V12. Product Number: 1017979.Potential that mis-ordered frames in Vue Motion during dynamic cine runs may cause images frames to display out of sequence.accessdata.fda.gov
January 26, 202698326Class IIOngoingAzurion 3 M12 System Model Numbers: (1) 722063, (2) 722221, (3) 722229; Software Version Number - All versions: R1.X, R2.X, R3.XUnder certain conditions, the table may move unexpectedly when the Reset Geometry button is pressed - even when a table lock is active.accessdata.fda.gov
December 15, 202598109Class IIOngoingProduct Name: Allura Xper FD10C; Model number: 722001Philips has identified that in a limited number of impacted systems the drip tray beneath the cooling unit was not installed under previous field corrections, or evidence of the implementation was not adequately documented. If it is not installed, there is a potential for coolant liquid to contact electrical components. This could lead to electrical short-ciaccessdata.fda.gov
December 12, 202598108Class IIOngoingPhilips Azurion system; Software Version Number: R3.1Philips has identified two (2) software issues affecting device systems that may result in loss of imaging (X-ray) functionality and/or loss of motorized movement, and/or incorrect image content and/or loss of data. Issue 1 - System remains in continuous restart mode after the start-up. Issue 2 - Longitudinal Position Error Applicable only to systems with Poaccessdata.fda.gov
December 12, 202598096Class IIOngoingPhilips Azurion Systems with software versions R2.1.10 and R2.2.10. Includes the following label descriptions and corresponding models: 1. Azurion 3 M12. Model Numbers: 722063, 722221. 2. Azurion 3 M15. Model Numbers: 72Six (6) identified software issues which may result in the following: system keeps restarting, AMC triple drive, C-Partition of Suite PC running out of free space, system remains in continuous restart mode after the start-up, misalignment of Market Tool Overlay, and longitudinal positional error.accessdata.fda.gov
December 8, 202598071Class IIOngoingPhilips Azurion Systems R3.0. Includes the following label descriptions and corresponding models: 1. Azurion 3 M12. Model Number: 722229. 2. Azurion 3 M15. Model Number: 722230. 3. Azurion 5 M12. Model Number: 722231. 4.Nine (9) identified software issues which may result in the following: loss of X-ray after Pedal Tap, loss of X-ray after Phase Fault, missing live X-ray on the FlexVision monitor, system continues to restart, AMD triple drive, C-Partition of Suite PC running out of free space, system remains in continuous restart mode after start-up, misalignment of Marker accessdata.fda.gov
October 2, 202597719Class IIOngoingPhilips Azurion 7M20 systems with FlexArm ceiling-mounted system. Model Number: 722234The motorized longitudinal movement of the FlexArm stand may be inconsistent (not smooth) and eventually may become unavailable. This issue is due to grease leakage from the bearings and/or anti-corrosion oil applied on the bearings, because of which the lubrication on the ceiling rail may be excessive, reducing the friction between the rails and the frictioaccessdata.fda.gov
September 29, 202597682Class IIOngoingZenition 50; Product Number (REF): 718096; Interventional fluoroscopic x-ray systemOver time some systems may experience loss of imaging functionality and/or poor image quality due to potential corrosion of the Image Intensifier Television (IITV) control board.accessdata.fda.gov
September 3, 202597502Class IIOngoingAllura Xper FD10C; Model Number: 722001; Associated 510(k)s: K102005, K130638, K130842, K133292, K141979, K162859, K161563The BIOS battery may deplete faster than initially anticipated during the design phase. When the battery is depleted, the start-up process of the system will be halted, and the system will not start. No user messages are shown before the battery is low on power or depleted.accessdata.fda.gov
September 3, 202597501Class IIOngoingAllura Xper FD10 Product Codes: (1)722010, (2) 722026, (3) 722003; Associated 510(k) numbers: K102005, K130842, K130638, K133292, K141979, K161563, K162859, K033737, K041949Systems may not perform as intended due to the deterioration of certain internal components (the CMOS battery, hard disk drive, and/or power supply unit). If this deterioration occurs, motorized movements of the system will become unavailable. Manual movements of the stand (longitudinal, transversal and rotational for ceiling mounted systems and rotational faccessdata.fda.gov
August 1, 202597359Class IIOngoingInterventional Fluoroscopic X-Ray System - Philips Allura Xper Series. Labeled as the following with corresponding model numbers: 1. Allura Xper FD10, Model Number 722003. 2. Allura Xper FD10/10, Model Number 722005. 3. Potential that a component (air baffle) may be missing in some Nehalem FlexVision-2 PCs that are part of the Allura Xper series.accessdata.fda.gov
August 1, 202597249Class IIOngoingPhilips Azurion System configured with a 1 Phase UPS. Azurion family (R1.x, R2.x). Labeled as the following with corresponding model numbers: 1. Azurion 3 M12, Model Number 722063. 2. Azurion 3 M15, Model Number 722064. Philips Azurion and Allura systems configured with a 1 Phase Uninterruptible Power Supply (UPS) have the potential of shutting down and/or not starting up, if power to the system is lost.accessdata.fda.gov
June 30, 202597155Class IIOngoingPhilips Allura R8.2.x Systems. Software Verion: R8.2.x. 1. Allura Xper FD10, Model Number: 722026. 2. Allura Xper FD10/10, Model Number: 722027. 3. Allura Xper FD20, Model Number: 722028. 4. Allura Xper FD20/10, Model NuPotential for temporary loss of imaging (X-ray) functionality due to software issue.accessdata.fda.gov
June 4, 202597055Class IIOngoingAzurion 7 M20. Fluoroscopic X-Ray System.Potential for bolts connecting the gearbox to the mounting flange of the C-arm to become loose.accessdata.fda.gov
May 28, 202596962Class IIOngoingAzurion R1.x and R2.x systems; Model Numbers: (1) 722063, (2) 722064, (3) 722067, (4) 722068, (5) 722078, (6) 722079, (7) 722221, (8) 722222, (9) 722223, (10) 722224, (11) 722225, (12) 722226, (13) 722227, (14) 722228, (A software issue was identified in the internal communication process between the system software and the X-ray generator firmware. Loss of imaging (X-ray) functionality caused by the software issue in either of the two situations identified could result in a delay of therapy. The potential delay may result in serious adverse health outcomes, including the paccessdata.fda.gov
March 24, 202596728Class IIOngoingEnterprise 1.5T, Model Number: 781145The Quadrature Body Coil (QBC) seal adhesive may fail, creating sharp edges that may come in contact with patients. If the QBC seal becomes loose during the scanning process, the risk to the patient may include skin abrasions, bruises, lacerations, hair loss/entanglement, and tissue injury.accessdata.fda.gov
January 13, 202596132Class IOngoingAllura Xper FD10 - Catalog numbers: (1) 722003, (2) 722010, (3) 722026Possibility of the patient falling from the table related to the mattress used on the patient table.accessdata.fda.gov
January 13, 202596120Class IIOngoingAllura CV20 System Code: 722031Potential safety issue with the AD7 and AD7X patient tables (both tilt and non-tilt versions) part of the Philips Allura and Azurion systems. During manual repositioning of the patient tabletop, a finger can get entrapped between the longitudinal guiding rails and the tabletop. This may result in an injury of the finger, applicable for operators and service accessdata.fda.gov
November 11, 202495713Class IIOngoingPhilips Allura Xper Systems (R7.6-R8.1). Labeled as the following: 1. Allura Xper FD10, Model Number: 722010. 2. Allura Xper FD10/10, Model Number: 722011. 3. Allura Xper FD20, Model Number: 722012. 4. Allura Xper FD20 BPotential safety issues in Allura Xper R7.6- R8.1 systems where the Lifetime Extension (LTE) kit is not installed in a timely manner. Root cause is under investigation, but the recall reason is listed as for systems over 10 years of life with LTE kits are experiencing propeller motor clamping bolt and x-ray tube locking bolt breaks. If this happens, it may caccessdata.fda.gov
October 7, 202495579Class IIOngoingPhilips Zenition 50, Model Number: 718096Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure.accessdata.fda.gov
August 22, 202495256Class IIOngoingSystem Code Name: 722282 Azurion 7 M20 722281 Azurion 5 M20 722236 Azurion 7 B20 722235 Azurion 7 B12 722234 Azurion 7 M20 722233 Azurion 7 M12 722228 Azurion 5 M20 722227 Azurion 5 M12 722226 Azurion 7 B20 722225 AzurioPotential Detachment of the Cable Hose Carrier (due to broken plastic and/or bolts) which May Result in Parts Falling and/or Part of the Cable Hose Dropping, and result in injury.accessdata.fda.gov
August 8, 202495144Class IIOngoingPhilips Allura Xper systems (R8.1 with Poly-G Stand) Interventional Fluoroscopic X-Ray System, Model Numbers 722010, 722012, 722013A half-threaded bolt was included in the LTE kits instead of the correct full-threaded bolt.accessdata.fda.gov
August 6, 202495148Class IIOngoingPhilips Azurion 7M20 systems with FlexArm ceiling-mounted system, Interventional Fluoroscopic X-Ray System, Model Numbers 722079 and 722224The motorized longitudinal movement of the FlexArm stand may be inconsistent (not smooth) and eventually may become unavailable. This issue is due to grease leakage from the bearings and/or anti-corrosion oil applied on the bearings, because of which the lubrication on the ceiling rail may be excessive, reducing the friction between the rails and the frictioaccessdata.fda.gov
July 15, 202494994Class IIOngoingPhilips Azurion Interventional Fluoroscopic X-ray System with Software Version Number: R1.0, R1.1, R1.2- Intended for Image guidance in diagnostic, interventional, and minimally invasive surgery procedures for the followPotential Loss of Imaging (X-ray) Functionality and/or Longer Time to Perform Cold Restartaccessdata.fda.gov
May 16, 202494647Class IIOngoingPhilips Allura Xper FD20 system with an ADN7NT patient table. Model Number: 722012, Software Version Number 8.1.100.When Software upgrade 8.1.100 is installed on an Allura Xper with an AD7NT (non tilt) table, the pivot brake does not engage. This issue may cause unexpected movements of the table.accessdata.fda.gov
May 2, 202494593Class IIOngoingPhilips Interventional Hemodynamic Application R.1.2X, R.1.3.0, R1.2.1. Software that enables invasive investigation of cardiac and vascular diseases.Potential for pressure wave data synchronization from two devices may not be correct.accessdata.fda.gov
February 6, 202493966Class IIOngoingAzurion 3 with a Certeray generator -To perform image guidance in diagnostic, interventional, and minimally invasive surgery procedures Models: (1) 722221 (2) 722222 (3) 722280Generator may fail due to a potential short circuit in the Printed Circuit Board Assembly (PCBA) in PoInt EVR (Power Invertor). If a short circuit occurs, it will cause the fuses to trip and the system will become non-functional due to power loss, resulting in a potential delay of procedure or termination of procedure.accessdata.fda.gov
January 2, 202493783Class IIOngoingPhilips Allura Xper Interventional Fluoroscopic X-ray Systems, specifically the Disk Bay of the PC component of affected systems. Affected PCs: FlexVision PC Allura Xper Model Name - Model Number: Allura Xper FD10 722003Framegrabber card may not perform as intended. Monitor may show no viewports, or show one or more viewports may show no image, a distorted image, or a frozen image. Switching between viewports on the monitor may not be possible. Issue may result in delay of procedure.accessdata.fda.gov
January 2, 202493781Class IIOngoingPhilips Allura Xper Interventional Fluoroscopic X-ray Systems, specifically the Disk Bay of the PC component of affected systems. Affected PCs: Imaging Processing PC, Host PC, FlexVision PC Allura Xper Model Name - ModelDisk Bay may not perform as intended. System may stop functioning and imaging may not be possible, resulting in delay of procedure.accessdata.fda.gov
January 2, 202493777Class IIOngoingPhilips Allura Xper Interventional Fluoroscopic X-ray Systems, specifically the DIMMs (Dual In-line Memory Modules) used with affected systems. Allura Xper Model Name - Model Number: Allura Xper FD10 722003 722010 722026Dual In-Line Memory Modules (DIMMs) may not perform as intended. System may stop functioning and imaging may not be possible, resulting in delay of procedure.accessdata.fda.gov
December 12, 202393755Class IIOngoingPhilips Azurion system, Interventional fluoroscopic x-ray system. System Product Name - Model Numbers Azurion 3M12 -722063, 722221; Azurion 3M15 - 722064, 722222; Azurion 5M12 - 722227; Azurion 5M20 - 722228; Azurion 7B1System may exhibit a loss of imaging functionality and data due to an issue which can cause the system to continuously restart. If the issue occurs during a procedure, there may be a delay and/or abortion of the procedure.accessdata.fda.gov
December 8, 202393734Class IIOngoingAzurion 7 M20 FlexArm system (Software version R2.x) with Maquet Magnus Table (Software version 05.02.12)Loss of connectivity between the FlexArm and the Table due to a software issue related to the date/time format. This connection issue leads to a loss of movement of the arm or table.accessdata.fda.gov
December 8, 202393721Class IIOngoingAzurion 7 M20 FlexArm system (Software version R2.x) with Maquet Magnus Table (Software version 05.02.12)Loss of connectivity between the FlexArm and the Table due to a software issue.accessdata.fda.gov
November 3, 202393416Class IIOngoingPhilips Allura systems with monoplane fixed ceiling mounts: 722001 Allura Xper FD10C 722003 Allura Xper FD10 722006 Allura Xper FD20 722010 Allura Xper FD10 722012 Allura Xper FD20 722015 Allura Xper FD20 OR Table 722016Ceiling mounted L-arm contains a rotation cover that may potentially be susceptible to falling if a collision between the L-arm and other hospital equipment (i.e., an operating light) were to occur result in injury or potential sterility issues due to the cover becoming looseaccessdata.fda.gov
August 15, 202392901Class IIOngoingPhilips Allura Xper, Allura Centron, Allura CV, Azurion, UNIQ Clarity, and MultiDiagnost-Eleva systemsA damaged foot switch may cause instances where no or only intermittent x-ray radiation initiation is possible.accessdata.fda.gov
June 30, 202392782Class IIOngoingWireless Foot Switch distributed with Philips Allura Xper and Azurion Interventional Fluoroscopic X-Ray SystemsLoss of availability of the wireless foot switch during procedures.accessdata.fda.gov
June 12, 202392635Class IIOngoingAllura Xper FD10 and FD20. X-ray Imaging System.The bolts supporting the FlexMove Carriage may become loose and/or break, and cracks may appear in the suspension rail of the FlexMove Carriage.accessdata.fda.gov
March 21, 202392165Class IIOngoingPhilips Azurion System with software versions: R2.2.O, R2.2.1, R2.2.3, R2.2.5 and R2.2.6. Models/Model Number: (1) Azurion 3M12: 722063, 722221; (2) Azurion 3M15: 722064, 722222; (3) Azurion SM12: 722227; (4) Azurion SM2Potential Loss of X-ray-When the full disk capacity is reached, X-Ray functionality will cease to be available there will be a sudden interruption of the procedureaccessdata.fda.gov
February 20, 202391806Class IIOngoingSmartPerfusion, release R1.0, R1.1, R1.1.1, R1.1.5, R1.1.5.1 and R1.1.6There are technical issues related to signal generation and processing, which can lead to inaccurate presentations.accessdata.fda.gov
December 2, 202189437Class IIOngoingZenition 50, Model #718096Firm discovered that the wireless foot switch can suddenly stop responding due to a firmware issue. If the wireless foot switch fails, there could be a delay or interruption of procedure if the hand switch is not used or if the wired foot switch is not connected to the system.accessdata.fda.gov
May 26, 202189964Class IIOngoingAzurion systems with software release R1.xIn the Azurion system, the user can add a new study to a patient by selecting the option Add Study. The Add Study dialogue box is then displayed where the Patient Type is selected to perform the study. Due to a software defect, when the study is initiated by pressing Start Procedure, the Patient Type changes inadvertently to a Patient Type different than theaccessdata.fda.gov
March 25, 201982610Class IITerminatedIngenia Ambition S (781359), Ingenia Ambition X (781356) with Magnet Energization Device (MED), Philips MR systems are indicated for use as a diagnostic device. The purpose of the MED is to supply power to charge the magMagnet Energization Device (MED) can have a residual voltage on output terminal, may cause electrical shocks to personnel servicing the MED, MDD or connected cabling.accessdata.fda.gov
February 19, 201982459Class IITerminatedFoot Switches used with Philips MultiDiagnost Eleva with Flat Detector; Product Codes: 708037, 708038 Product The Allura Xper FD Series are intended for use on human patients to perform: Vascular, cardiovascular and neurAdditional units have been identified for previous recall Z-1280-2016 (RES 69339): If a Footswitch is frequently used on a non-flat surface or in the pedestal, the footswitch pedals may get bent. This might cause an intermittent or continuous inability of making live fluoroscopy images or exposures.accessdata.fda.gov
December 21, 201882038Class IITerminatedProdiva CS, Model Number 781069. Nuclear Magnetic Resonance Imaging SystemThere is a potential for the ceiling speaker(s) to fall from their position and be pulled to the MR system by the magnetic field.accessdata.fda.gov
December 3, 201881797Class IITerminatedIngenia Elition S, Ingenia Elition XDuring automatic tabletop movement, pressing and holding the Stop Table button may lead to an unexpected restart of the table movement.accessdata.fda.gov
November 30, 201883366Class IITerminatedAzurion lnterventional Fluoroscopic X-ray System, with software version 1.2Philips has discovered through customer complaints and internal testing an intermittent electronic product defect in accordance with 21 CFR 1003.2(b)(1). When performing Cine runs, the Azurion's automatic exposure control software may set technique factors that result in radiation emissions too low to obtain useful diagnostic images.accessdata.fda.gov
May 1, 201880271Class IITerminatedOmniDiagnost-Eleva X-ray system Angiographic and Diagnostic, Product Nos. 708026, 708027, 708028The fixation of the upper and lower tilt actuator, of the Omnidiagnost system might break off and the table will start to rotate from 0 to + 90 /- 90 degree with high speed. This rotating movement can not be stopped by the user. This could potentially lead to the patient falling off the table. There is a risk of injury for the patient, user, or bystander.accessdata.fda.gov
March 26, 201879783Class IITerminatedMultiDim Eleva 708032 As a multifunctional universal imaging application system, General RJF, Fluoroscopy, Radiography and Angiography can be Performed along with more specialized interventional applications on human patThe fixation of the upper and lower tilt actuator, of the MD-Eleva system might break off and the table will start to rotate from 0 to + 90 I- 90 degree with high speed. This rotating movement cannot be stopped by the user.accessdata.fda.gov
June 23, 201687978Class IITerminatedPhilips Allura Xper System: Interventional Fluoroscopic X-Ray System Product No.: 722026, 722027, 722028, 722029, 722035, 722038, and 722058.Certain low-voltage DC power supplies (DCPS) used in these products may be subject to an increased probability of failure. Failure of a DCPS may result in the sudden loss of imaging functionality or mechanical movement, depending on what subsystems the DCPS is powering.accessdata.fda.gov
February 24, 201261267Not yet classifiedTerminatedPhilips MultiDiagnost Eleva II Software Version R4.1.x Model: 708032 This Philips MultiDiagnost Eleva system is intended to be used as a multifunctional I universal system. General R/F. Fluoroscopy, Radiography and AngioDisplayed skin dose rate is calculated using an incorrect point of reference, resulting in too low displayed values.accessdata.fda.gov
January 27, 201261043Not yet classifiedTerminatedPhilips Intellispace Portal, Release 4.0.0. For storing, processing and management of electronic information/data Model: 881001. Indicated for use as a diagnostic device.There maybe incorrect values in the diffusion/perfusion maps.accessdata.fda.gov
March 27, 201158320Not yet classifiedTerminatedS8-3t Micro TEE Transducer is an Ultrasonic Diagnostic. The Part # is 989605379471. The User information is labeled in part: "***iE33 Ultrasound System ***User Information Update***4535 614 04811 Rev A***New S8-3t TEE TrUsers of the Philips model S8-3t Micro TEE Transducer have reported that significant image quality degradation may occur after a number of use/cleaning cycles. If users do not inspect the transducer for such damage prior to each use, imaging may not always be available, which could pose a risk for patients.accessdata.fda.gov

Compare with other makers

Updated June 16, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.