Data / Medical devices / China / Philips Healthcare (Suzhou) Co., Ltd.
Philips Healthcare (Suzhou) Co., Ltd.: FDA-registered device maker in Suzhou Jiangsu, China, 12 510(k) clearances
Philips Healthcare (Suzhou) Co., Ltd. is registered with the FDA (registration 3009529630) in Suzhou Jiangsu, China. It lists 4 device types. The FDA files 12 510(k) clearances under its listings, the newest dated March 23, 2026. 4 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3009529630
- Address
- No. 258, Zhongyuan Road Suzhou Industrial Park, Suzhou Jiangsu, China, 215024
- Owner or operator
- Philips Medical Systems International BV (1217116)
- Roles
- Complaint file establishment, Manufacturer, Specification developer
- First device listed
- November 3, 2014
- Registered through
- 2026
- Brand names listed
- CT 5300, CT Areta RT, CT Rembra, CT Rembra RT, DigitalDiagnost C50, DuraDiagnost, Incisive CT, Smart Fit Knee 3T and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Coil, Magnetic Resonance, Specialty | MOS | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Solid State X-Ray Imager (Flat Panel/Digital Imager) | MQB | 2 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| System, X-Ray, Stationary | KPR | 2 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| System, X-Ray, Tomography, Computed | JAK | 2 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| March 23, 2026 | K252992 | CT Rembra RT; CT Areta RT; CT Rembra | JAK | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| March 20, 2026 | K260519 | Smart Fit TorsoCardiac 1.5T | MOS | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| May 3, 2024 | K232491 | CT 5300 | JAK | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| February 5, 2024 | K233600 | Smart Fit Knee 3.0T | MOS | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| September 1, 2023 | K232021 | Smart Fit TorsoCardiac 1.5T and Smart Fit Shoulder 1.5T | MOS | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| April 27, 2022 | K212441 | Philips Incisive CT | JAK | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| December 1, 2021 | K212864 | dS TorsoCardiac 1.5T, dS MSK S 1.5T, dS MSK M 1.5T | MOS | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| July 10, 2020 | K201725 | DigitalDiagnost C50 | KPR | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Lit. | accessdata.fda.gov |
| July 9, 2020 | K201640 | DuraDiagnost | KPR | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| March 20, 2018 | K180015 | Philips Incisive CT | JAK | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| January 4, 2017 | K163410 | DigitalDiagnost C50 | KPR | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
| June 12, 2014 | K141381 | DURADIAGNOST | KPR | Substantially Equivalent | Philips Healthcare (Suzhou) Co., Ltd. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| June 26, 2026 | 99511 | Class II | Ongoing | Philips Incisive CT with software V4.5&V5.0, Product Code 728143 and Product Code 728144. | Potential of failing to trigger clinical scan during Bolus Tracking. | accessdata.fda.gov |
| December 3, 2025 | 98238 | Class II | Ongoing | Philips Incisive CT | Potential for incomplete scan due to unstable connection inside of floating sensor. | accessdata.fda.gov |
| December 23, 2022 | 93574 | Class II | Ongoing | Incisive CT, model 728143 & 728144 running Software Version 5.0.0. | Multiple software issues which have the potential to lead to misdiagnosis due to image artifacts or incorrect image orientation labels, or the need for a CT rescan. These include: 1. Artifacts may occur on perfusion images, 2. Orientation label reversed in 2D images, 3. Auto voice does not work during the cardiac scan, 4. Auto voice and operators voice are t | accessdata.fda.gov |
| February 24, 2021 | 87473 | Class II | Terminated | Philips CT systems are advanced continuous-rotation computed tomography systems suitable for a wide range of computed tomographic (CT) applications - Product Usage: intended for use in the head and whole body. | Philips has internally detected an issue with the actuators used in the Incisive CT couch, which could result in the couch failure to self-lock, and unexpectedly moving slowly downward to its limit position. | accessdata.fda.gov |
Compare with other makers
- All makers of Coil, Magnetic Resonance, Specialty
- All makers of System, X-Ray, Tomography, Computed
- All makers of System, X-Ray, Stationary
- All makers of Solid State X-Ray Imager (Flat Panel/Digital Imager)
Updated August 21, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.