Data / Medical devices / Ireland / Phenox Limited
Phenox Limited: FDA-registered device maker in Galway Galway(County), Ireland, 7 510(k) clearances
Phenox Limited is registered with the FDA (registration 3013656790) in Galway Galway(County), Ireland. It lists 6 device types. The FDA files 7 510(k) clearances under its listings, the newest dated January 15, 2026. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3013656790
- Address
- Kamrick Court Ballybrit Business Park, Galway Galway(County), Ireland, H91XY38
- Owner or operator
- phenox Limited (10061667)
- Roles
- Complaint file establishment, Manufacturer
- First device listed
- November 7, 2019
- Registered through
- 2026
- Brand names listed
- Esperance pHLO Aspiration System, pNOVUS 21 Microcatheter, pORTAL Steerable Hydrophilic Guidewire, pRESET Delta LITE Thrombectomy Device, pRESET Delta Thrombectomy Device, pRESET LITE Thrombectomy Device, pRESET Thrombectomy Device
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Catheter, Intravascular, Diagnostic | DQO | 2 | Manufacturer | accessdata.fda.gov |
| Catheter, Percutaneous, Neurovasculature | QJP | 2 | Manufacturer | accessdata.fda.gov |
| Catheter, Thrombus Retriever | NRY | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Guide, Wire, Catheter, Neurovasculature | MOF | 2 | Manufacturer | accessdata.fda.gov |
| Neurovascular Mechanical Thrombectomy Device For Acute Ischemic Stroke Treatment | POL | 2 | Manufacturer | accessdata.fda.gov |
| Wire, Guide, Catheter | DQX | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| January 15, 2026 | K251357 | Esperance pHLO Aspiration System | NRY | Substantially Equivalent | Phenox, Ltd. | accessdata.fda.gov |
| February 28, 2025 | K242676 | pRESET Delta Thrombectomy Device and pRESET Delta LITE Thrombectomy Device | POL | Substantially Equivalent | Phenox Limited | accessdata.fda.gov |
| November 12, 2024 | K242420 | pNOVUS 21 Microcatheter | DQO | Substantially Equivalent | Phenox, Ltd. | accessdata.fda.gov |
| October 21, 2023 | K231539 | pRESET LITE Thrombectomy Device | POL | Substantially Equivalent | Phenox Limited | accessdata.fda.gov |
| January 20, 2023 | K222848 | pRESET Thrombectomy Device | POL | Substantially Equivalent | Phenox Limited | accessdata.fda.gov |
| November 28, 2022 | K221279 | pNOVUS 21 Microcatheter | DQO | Substantially Equivalent | Phenox, Ltd. | accessdata.fda.gov |
| October 9, 2019 | K191687 | pORTAL Steerable Hydrophilic Guidewire and pORTAL EXT Extension Wire | DQX | Substantially Equivalent | Phenox Limited | accessdata.fda.gov |
Compare with other makers
- All makers of Catheter, Percutaneous, Neurovasculature
- All makers of Catheter, Intravascular, Diagnostic
- All makers of Catheter, Thrombus Retriever
- All makers of Neurovascular Mechanical Thrombectomy Device For Acute Ischemic Stroke Treatment
- All makers of Wire, Guide, Catheter
- All makers of Guide, Wire, Catheter, Neurovasculature
Updated January 15, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.