Data / Medical devices / Finland / Palodex Group OY
Palodex Group OY: FDA-registered device maker in Tuusula Uusimaa, Finland, 14 510(k) clearances
Palodex Group OY is registered with the FDA (registration 3005383085) in Tuusula Uusimaa, Finland. It lists 11 device types. The FDA files 14 510(k) clearances under its listings, the newest dated November 17, 2025. 4 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3005383085
- Address
- Nahkelantie 160, Tuusula Uusimaa, Finland, 04300
- Owner or operator
- PaloDEx Group Oy (9079085)
- Roles
- Complaint file establishment, Exporter to the US, Manufacturer
- First device listed
- October 31, 2005
- Registered through
- 2026
- Brand names listed
- DIGORA Optime, DTX Studio Assist, DTX Studio Clinic, DTX Studio Core, DTX Studio Diagnose, DTX Studio Implant, DTX Studio Lab, FOCUS and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Abutment, Implant, Dental, Endosseous | NHA | 2 | Complaint file establishment | accessdata.fda.gov |
| Analyzer, Medical Image | MYN | 2 | Complaint file establishment | accessdata.fda.gov |
| Automated Radiological Image Processing Software | QIH | 2 | Complaint file establishment | accessdata.fda.gov |
| Dental Abutment Design Software For Dental Laboratory | PNP | 2 | Complaint file establishment | accessdata.fda.gov |
| Film, Radiographic | IWZ | 1 | Manufacturer | accessdata.fda.gov |
| Medical Device Data System | OUG | 1 | Complaint file establishment | accessdata.fda.gov |
| System, Image Processing, Radiological | LLZ | 2 | Complaint file establishment | accessdata.fda.gov |
| System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations | NOF | 2 | Exporter to the US | accessdata.fda.gov |
| System, X-Ray, Extraoral Source, Digital | MUH | 2 | Manufacturer | accessdata.fda.gov |
| Unit, X-Ray, Extraoral With Timer | EHD | 2 | Manufacturer | accessdata.fda.gov |
| X-Ray, Tomography, Computed, Dental | OAS | 2 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| November 17, 2025 | K252086 | DTX Studio Assist | MYN | Substantially Equivalent | Nobel Biocare C/O Medicim NV | accessdata.fda.gov |
| September 12, 2024 | K241249 | Orthopantomograph OP 3D LX (PAN 3D); Orthopantomograph OP 3D LX (PAN CEPH 3D) | OAS | Substantially Equivalent | Palodex Group OY | accessdata.fda.gov |
| December 8, 2023 | K231898 | DTX Studio Clinic (4.0) | LLZ | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| June 9, 2023 | K230505 | Orthopantomograph OP 3D LX | OAS | Substantially Equivalent | Palodex Group OY | accessdata.fda.gov |
| March 25, 2022 | K213562 | DTX Studio Clinic 3.0 | LLZ | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| November 20, 2020 | K203156 | DTX Studio Clinic | LLZ | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| October 8, 2020 | K200810 | IPS CaseDesigner | LLZ | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| March 1, 2019 | K181932 | DTX Studio design | PNP | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| June 7, 2018 | K180947 | Orthopantomograph OP 3D | OAS | Substantially Equivalent | Palodex Group OY | accessdata.fda.gov |
| January 11, 2018 | K172224 | DTX Studio diagnose | LLZ | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| January 31, 2017 | K163122 | NobelClinician, DTX Studio implant | LLZ | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| November 10, 2016 | K161634 | IPS CaseDesigner | LLZ | Substantially Equivalent | Nobel Biocare AB | accessdata.fda.gov |
| March 20, 2014 | K133231 | DIGORA OPTIME | MUH | Substantially Equivalent | Instrumentarium Dental, Palodex Group OY | accessdata.fda.gov |
| July 13, 2000 | K001729 | FOCUS | EHD | Substantially Equivalent | Instrumentarium Corp. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| October 28, 2021 | 95017 | Class II | Ongoing | Orthopantomograph OP300 dental computed tomography x-ray system. The X-ray device produces conventional 2D X-ray images and Xray projection images for the reconstruction of a 3D view. The device is operated and used by q | It was noticed in production on 28.10.2021, that the final testing database gives a pass result for Pan ADC repeatability test even when the test result is not within the set acceptance criteria (repeatability within 4%). | accessdata.fda.gov |
| January 7, 2020 | 84544 | Class II | Terminated | Soredex DIGORA Optime SOLID STATE X-RAY IMAGER (FLAT PANEL/DIGITAL IMAGER) | Slow degradation of plastic insulation used in the PSU DC plug of the DIGORA Optime, Scan eXam, Express, GXPS-500 systems may result in short circuiting which may cause heating and melting. The melting may generate smoke and eventually cause the PSU to fail. | accessdata.fda.gov |
| January 14, 2014 | 67342 | Class II | Terminated | The FOCUS is a microprocessor controlled intra-oral x-ray unit with a Load Matching Frequency (LMF) DC generator, which produces dental images on digital and film media. For the digital images the FOCUS is connected to t | Instrumentarium Dental has delivered a number of FOCUS 3.0 Intraoral X-ray units in November 2013 with a potential flaw in the mounting hardware. A number of wall mount units were delivered with FOCUS X-ray machines that had not been properly welded at our supplier. As a result of the incomplete welding operation, the wall mount unit on the FOCUS X-ray unit | accessdata.fda.gov |
| April 28, 2006 | 37838 | Not yet classified | Terminated | Cranex Tome panoramic x-ray unit with Spiral Tomography for cross-sectional imaging. manufactured by SOREDEX, PO Box 250, 00031 Helsinki, Finland. | There may be a material defect in the up/down movement axle of the unit. This may cause the upper part of the unit to suddenly come down. | accessdata.fda.gov |
Compare with other makers
- All makers of Dental Abutment Design Software For Dental Laboratory
- All makers of Abutment, Implant, Dental, Endosseous
- All makers of Analyzer, Medical Image
- All makers of System, Image Processing, Radiological
- All makers of Unit, X-Ray, Extraoral With Timer
- All makers of X-Ray, Tomography, Computed, Dental
Updated November 17, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.