Data / Medical devices / United States / Orthoscan, Inc.
Orthoscan, Inc.: FDA-registered device maker in Scottsdale, AZ, United States, 8 510(k) clearances
Orthoscan, Inc. is registered with the FDA (registration 3005254598) in Scottsdale, AZ, United States. It lists 6 device types. The FDA files 8 510(k) clearances under its listings, the newest dated January 14, 2026. 2 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3005254598
- Address
- 14555 N. 82nd Street, Scottsdale, AZ, United States, 85260
- Owner or operator
- Ziehm-Orthoscan INC. (9073005)
- Roles
- Complaint file establishment, Manufacturer
- First device listed
- November 9, 2007
- Registered through
- 2026
- Brand names listed
- OrthoScan EMR Image Link, OrthoScan FD Mini C-arm, OrthoScan HD, OrthoScan Mobile DI, Orthoscan TAU MVP Mini C-arm System, Orthoscan TAU Mini C-arm, Orthoscan VERSA Mini C-Arm, TAU Model 1000-0015 Mini C-Arm and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Arthroscope | HRX | 2 | Manufacturer | accessdata.fda.gov |
| Image-Intensified Fluoroscopic X-Ray System, Mobile | OXO | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| Laparoscope, General & Plastic Surgery | GCJ | 2 | Manufacturer | accessdata.fda.gov |
| Solid State X-Ray Imager (Flat Panel/Digital Imager) | MQB | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| System, Digital Image Communications, Radiological | LMD | 1 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
| System, X-Ray, Fluoroscopic, Image-Intensified | JAA | 2 | Complaint file establishment, Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| January 14, 2026 | K252579 | Orthoscan TAU MVP Mini C-Arm System | OXO | Substantially Equivalent | Ziehm-Orthoscan, Inc. | accessdata.fda.gov |
| July 2, 2025 | K250587 | Orthoscan TAU Mini C-Arm | OXO | Substantially Equivalent | Ziehm-Orthoscan, Inc. | accessdata.fda.gov |
| January 14, 2025 | K243452 | Orthoscan VERSA Mini C-Arm | OXO | Substantially Equivalent | Ziehm-Orthoscan, Inc. | accessdata.fda.gov |
| October 21, 2021 | K213113 | Orthoscan Tau Mini C-Arm | OXO | Substantially Equivalent | Orthoscan, Inc. | accessdata.fda.gov |
| June 21, 2019 | K183220 | OrthoScan TAU Mini C-Arm | OXO | Substantially Equivalent | Orthoscan, Inc. | accessdata.fda.gov |
| March 28, 2014 | K133174 | ORTHOSCAN FD MINI C-ARM | OXO | Substantially Equivalent | Orthoscan, Inc. | accessdata.fda.gov |
| January 5, 2012 | K113708 | ORTHOSCAN MOBILE DI MINI C-ARM | OXO | Substantially Equivalent | Orthoscan, Inc. | accessdata.fda.gov |
| August 9, 2005 | K051754 | ORTHOSCAN, ORTHOSCAN HD | OXO | Substantially Equivalent | Orthoscan, Inc. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| August 8, 2024 | 95709 | Class II | Ongoing | Ziehm Solo. Digital Mobile C-arm | Ziehm Imaging, Inc., distributor, have been informed by manufacturer, Ziehm Imaging GmbH that installed devices may not fully meet the requirements of IEC 60601-2-54 and or 21 CFR 1020.32(c) with respect to wired hand switch may fail when being exposed to mechanical stress such as shocks (e.g. dropping) or impacts can irreversibly damage the switching elemen | accessdata.fda.gov |
| August 31, 2017 | 78784 | Class II | Terminated | Mobile Mini C-arm system Part # 1000-0001. Intended to provide the physician with general fluoroscopic visualization of the patient, including, but not limited to, surgical orthopedic procedures and critical and emergenc | OrthoScan Inc. discovered during investigation of a non-standard work flow a non-conformity of the devices. Specifically, the system software allows a user to activate the Digital Zoom feature in the course of taking a live image exposing a larger x-ray field than can be viewed by the user | accessdata.fda.gov |
Compare with other makers
- All makers of System, X-Ray, Fluoroscopic, Image-Intensified
- All makers of Image-Intensified Fluoroscopic X-Ray System, Mobile
- All makers of Solid State X-Ray Imager (Flat Panel/Digital Imager)
- All makers of System, Digital Image Communications, Radiological
- All makers of Arthroscope
- All makers of Laparoscope, General & Plastic Surgery
Updated January 14, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.