Skip to the page

Data / Medical devices / United States / Orthopediatrics, Corp

Orthopediatrics, Corp: FDA-registered device maker in Warsaw, IN, United States, 48 510(k) clearances

Orthopediatrics, Corp is registered with the FDA (registration 3006460162) in Warsaw, IN, United States. It lists 64 device types. The FDA files 48 510(k) clearances under its listings, the newest dated September 24, 2026. 22 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3006460162
Address
2850 Frontier Dr, Warsaw, IN, United States, 46582
Owner or operator
ORTHOPEDIATRICS, CORP (9102640)
Roles
Complaint file establishment, Repackager or relabeler, Specification developer
First device listed
May 15, 2008
Registered through
2026
Brand names listed
3, 3.5, 7 Bone Screws, 4 Bone Screws, 6.5 and 7.3mm Large Fragment Cannulated Screw System, Aspire Ortho Spine System, Awl, BENDER, Bone Screw System, Cortical, Cancellous and Cannulated Bone Screws and more

Devices it lists

DeviceProduct codeClassRoleSource
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple ComponentKTT2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Appliance, Fixation, Spinal InterlaminalKWP2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
AwlHWJ1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
BenderHXW1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Bit, DrillHTW1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Bit, SurgicalGFG1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Bone Fixation Cerclage, SublaminarOWI2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Chisel, Surgical, ManualFZO1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ClampHXD1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Cutter, SurgicalFZT1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Cutter, WireHXZ1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Device, Fixation, Proximal Femoral, ImplantJDO2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Driver, Surgical, PinGFC1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Elevator, Surgical, General & Plastic SurgeryGEG1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ExtractorHWB1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Fastener, Fixation, Nondegradable, Soft TissueMBI2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
FileHTP1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ForcepsHTD1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Gauge, DepthHTJ1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Growing Rod SystemPGM2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Guide, Surgical, InstrumentFZX1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Hammer, SurgicalFZY1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Hook, BoneKIK1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ImpactorHWA1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Instrument, Bending Or ContouringHXP1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Instrument, CompressionHWN1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Instrument, Surgical, Orthopedic, Dc-Powered Motor And Accessory/AttachmentKIJ1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Kit, Surgical Instrument, DisposableKDD1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
MalletHXL1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Medical Device Data SystemOUG1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Orthopedic Manual Surgical InstrumentLXH1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Orthopedic Stereotaxic InstrumentOLO2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Orthosis, Limb BraceIQI1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Orthosis, Spinal Pedicle FixationMNI2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Orthosis, Spondylolisthesis Spinal FixationMNH2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
OsteotomeHWM1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
PasserHWQ1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Pedicle Screw Spinal System, Adolescent Idiopathic ScoliosisOSH2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Pin, Fixation, SmoothHTY2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Pin, Fixation, ThreadedJDW2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Plate, Bone, Growth Control, Pediatric, EpiphysiodesisOBT2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Plate, Fixation, BoneHRS2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ProbeHXB1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Prosthesis, Rib ReplacementMDI2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ProtractorHTH1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Punch, SurgicalLRY1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
RaspHTR1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ReamerHTO1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
RetractorGAD1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Rod, Fixation, Intramedullary And AccessoriesHSB2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Screw, Fixation, BoneHWC2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
ScrewdriverHXX1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Software For Diagnosis/TreatmentOSN2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Staple, Fixation, BoneJDR2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Stylet, Surgical, General & Plastic SurgeryGAH1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Table, Surgical With Orthopedic Accessories, ManualJEB1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
TampHXG1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Tap, BoneHWX1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Tape, Measuring, Rulers And CalipersFTY1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
TemplateHWT1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Thoracolumbosacral Pedicle Screw SystemNKB2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Tray, Surgical, InstrumentFSM1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Washer, Bolt NutHTN2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
WrenchHXC1Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
September 24, 2026K261345Pediatric Nailing Platform FemurHSBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
April 30, 2026K260323OrthoPediatrics® Locking Cannulated Blade Plate SystemHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
October 9, 2025K252600Pediatric Plating Platform I Small-MiniHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
June 24, 2025K251362PediFlex™ Flexible Nail SystemHTYSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
April 29, 2025K243963Pediatric Plating Platform HipHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
April 1, 2025K250623Pediatric Nailing Platform Tibia Pediatric Nailing Platform FemurHSBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
March 14, 2025K241816VerteGlide Spinal Growth Guidance SystemPGMSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
March 7, 2025K243798Orthex External Fixation SystemKTTSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
January 20, 2024K233105RESPONSE™ Rib and Pelvic SystemMDISubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
August 21, 2023K231266Pediatric Nailing Platform TibiaHSBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
March 23, 2023K222105RESPONSE 5.5/6.0 Cannulated Screw SystemNKBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
February 10, 2023K223786Orthex External Fixation SystemKTTSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
July 20, 2022K220679Pediatric Nailing Platform FemurHSBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
April 8, 2022K220809Drive Rail SystemKTTSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
February 4, 2021K203573RESPONSE Navigation InstrumentsOLOSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
January 29, 2021K201838PediFlex Flexible Nail SystemHTYSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
March 24, 2020K193100RESPONSE™ Spine System, RESPONSE™ 4.5/5.0 Spine System, RESPONSE™ 5.5/6.0 Spine SystemNKBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
March 16, 2020K200097Response BandLoc Spinal FixationOWISubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
October 9, 2019K190321Pediatric Nailing PlatformFemurHSBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
August 6, 2019K190992OrthoPediatrics PediFoot Deformity Corrections SystemHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
July 5, 2019K190324OrthoPediatrics Cannulated Screw SystemHWCSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
September 18, 2018K181390Response Spine System, Response 5.5/6.0 Spine System, Response 4.5/5.0 Spine SystemNKBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
May 10, 2018K172583OrthoPediatrics PediNail Intramedullary PlatformHSBSubstantially EquivalentOrthopediatrics, Inc.accessdata.fda.gov
December 6, 2017K172425OrthoPediatrics Wrist Fusion PlateHRSSubstantially EquivalentOrthopediatrics, Inc.accessdata.fda.gov
August 24, 2017K171173OrthoPediatrics Titanium PediPlates® SystemHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
February 13, 2017K163487Ultima HA Coated Half Pins and WireJDWSubstantially EquivalentVilex IN Tennessee, Inc.accessdata.fda.gov
September 27, 2016K162307OrthoPediatrics Locking Proximal Femur System Cortical ScrewsHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
August 11, 2016K161267Response BandLoc Spinal FixationOWISubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
March 24, 2016K151881X-Fix Line AdditionsKTTSubstantially EquivalentVilex IN Tennessee, Inc.accessdata.fda.gov
March 23, 2016K160466Response 5.5 Spine SystemNKBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
May 22, 2015K150600Response 5.5/6.0 Spine SystemNKBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
July 29, 2014K140431PEDILOC FRAGMENT SYSTEMHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
July 23, 2014K132820VILEX ULTIMA EXTERNAL FIXATION SYSTEM WITH HA COATED PINS AND WIRESJDWSubstantially EquivalentVilex, Inc.accessdata.fda.gov
May 29, 2014K140822DRIVE RAIL SYSTEMKTTSubstantially EquivalentDevise Ortho, Inc.accessdata.fda.gov
June 20, 2013K130217ORTHOPEDIATRICS ACL RECONSTRUCTIVE SYSTEMMBISubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
May 8, 2013K130655RESPONSE SPINE SYSTEMOSHSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
August 5, 2011K110959ORTHOPEDIATRICS BLADE PLATE SYSTEMHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
June 17, 2011K111086ORTHOPEDIATRICS FRACTURE AND OSTEOTOMY BONE PLATE SYSTEMHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
May 17, 2010K100240ORTHOPEDIATRICS PEDILOC TIBIA PLATE SYSTEMHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
April 24, 2009K090666PEDIPLATESHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
March 11, 2009K083726PEDINAIL INTRAMEDULLARY NAILING SYSTEMHSBSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
January 30, 2009K083286ORTHOPEDIATRICS PEDILOC LOCKING PLATE SYSTEMHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
November 25, 2008K082949ORTHOPEDIATRICS BONE SCREWSHWCSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
October 17, 2008K082375ORTHOPEDIATRICS PEDIFLEX FLEXIBLE NAIL SYSTEMHTYSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
July 22, 2008K081407ORTHOPEDIATRICS PEDIPLATES SYSTEMHRSSubstantially EquivalentOrthoPediatrics Corp.accessdata.fda.gov
June 3, 2008K081097ORTHOPEDIATRICS PEDIFLEX FLEXIBLE NAIL SYSTEMHTYSubstantially EquivalentOrthopediatrics, LLCaccessdata.fda.gov
February 19, 2008K073344ORTHOPEDIATRICS PLATING SYSTEMHRSSubstantially EquivalentOrthopediatrics, LLCaccessdata.fda.gov
November 22, 2005K052196VILEX X-FIXKTTSubstantially EquivalentVilex, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
September 12, 202291098Class IIOngoingOrthex Large Bone Shoulder Bolt, model no. AS-17Bolt breakage on the head or threaded portion, which may cause loss of strut continuity with frame. This may cause loss of deformity correction and/or disruption of bone regeneration.accessdata.fda.gov
June 29, 202290738Class IIOngoingOrthex External Fixation Wire Sharp Bayonet 1.8 x 400 mm Model: K400-18BNManufacturing variance near transition of tip is increasing the likelihood the wire tip may fracture. The fractured tip may be retained in the patient. Retrieval attempts may be made which could result in a delay of surgery and potentially damage soft tissue and increase healing timeaccessdata.fda.gov
July 6, 202086027Class IIOngoingOrthopedics 6.0MM ROD, COCR, SINGLE HEX, 500MM LENGTH-The RESPONSE" 5.5/6.0 Spine System is intended for immobilization and stabilization of the posterior, non-cervical spine in skeletally mature patients as an adjunct tProduct may have incorrect laser etched alignment lines, the non-conforming laser etch may have compromised strength, lead to unintended fracture of the deviceaccessdata.fda.gov
June 5, 202085837Class IITerminatedOrthoPediatrics ACL Reconstruction System ShieldLoc 6mm implant component model number 10-1008-4060 - Product Usage: is intended for fixation of tendons and ligaments during orthopedic reconstruction procedures such as AShieldLoc implant component of the ACL Reconstruction Systemlots may be labeled with the incorrect size. Product labeled as 10-1008-4070 was found to have 10-1008-4060 product in the package. Product labeled as 10-1008-4060 was found to have 10-1008-4070 product in the package.accessdata.fda.gov
August 19, 201983884Class IITerminatedModel No. 01-1501-0032 (Child Nail Attachment Bolt). Component of the Pediatric Nailing Platform. Product Usage: an orthopedic implant system commonly referred to as an intramedullary fixation rod (product code HSB). TheBinding can occur between the attachment bolt and intramedullary nail, which may lead to delays in surgical procedures.accessdata.fda.gov
August 19, 201983767Class IITerminatedOrthoPediatrics Adolescent attachment bolt used with the Pediatric Nailing Platform (PNP) targeting arm- intended as an orthopedic implant system (bolt is used to attach the targeting arm to the intramedullary fixation rInterference can occur between the adolescent attachment bolt and the adolescent nail, cause a delay in surgical proceduresaccessdata.fda.gov
August 3, 201779067Class IITerminatedResponse 5.5/6.0 Spine System 7.0mm x 40mm Pedicle Screw Product Usage: Posterior non-cervical pedicle screw fixationThe 7mm diameter uniaxial pedicle screws have been color anodized with the same color utilized on 5 mm diameter screws.accessdata.fda.gov
April 24, 201777270Class IITerminatedResponse BandLoc 5.5/6.0 Tensioner Instrument The Tensioner Instrument (01-1102-1000) is utilized to allow the surgeon to apply a recommended tension to the band and hold it in place during spine manipulation and set scrOver-tensioning of the band resulting in damage to the band causing it to ruptureaccessdata.fda.gov
November 18, 201675758Class IIITerminatedOrthoPediatrics PediNail Intramedullary Nailing System 4.5mm X 48mm Cortical ScrewLabeled as a 48mm Cortical Screw but measuring at 50mmaccessdata.fda.gov
July 27, 201674928Class IITerminated3.5mm Bowed Locking Compression Femur Plates, 14 hole Orthopediatrics PediLoc Locking Plate System comes in sets that offer the advantage of both conventional and locking plate fixation devices and instrumentation in oneOrthoPediatrics Corp.is voluntarily recalling multiple lots of the 3.5mm Bowed Locking Compression Femur 14-hole Plate and 18-hole Plate due to the devices being mislabeled.accessdata.fda.gov
November 10, 201572962Class IITerminatedUniAxial Pedicle Screw & UniAxial Reduction Pedicle Screw The Response 5.5/6.0 Spine System is intended for immobilization and stabilization of the posterior, non-cervical spine in skeletally mature patients as an adjuncResponse Spine UniAxial Pedicle & UniAxial Reduction Pedicle Screws may have been manufactured incorrectly, thus preventing the driver from fully engaging into the hexagonal drive feature of the screw.accessdata.fda.gov
July 28, 201571933Class IITerminated3.5mm Non Locking Cortical Screw, in the PediLoc Tibial Plate System Part number 00-0903-2510, 3.5mm x 10mm Non Locking Cortical Screw. Used in pediatric orthopedics.The 00-0903-2510, 3.5mm x 10mm Non Locking Cortical Screw, Lot # 150192-J package may contain a different screw. The screw in the package is a 00-0903-2526, 3.5mm x 26mm, and is etched correctly.accessdata.fda.gov
July 25, 201469050Class IITerminatedACL Sleeve Installation Tool Sizes: 6mm, 6.5mm, 7.0mm, 7.5mm, 8.0mm, 8.5mm, 9.0mm, 10.0mm Product Usage: The OrthoPediatrics ACL Reconstruction System is a pediatric and small stature adult ACL reconstruction system thatWeld fractures on the Sleeve Installation Tool for ACL reconstruction system.accessdata.fda.gov
January 8, 201467302Class IITerminated3.5mm Locking Cortical Bone Screw, T15 Hexalobe, Self Tapping, 20mm Part No. 00-0903-2620 OrthoPediatrics Pediloc" Tibia Plates are indicated for fractures, osteotomies, and non-unions of the pediatric and small stature OrthoPediatrics has initiated a Voluntary RECALL of Part # 00-0903-2620, 3.5MM Locking Cortical Screw, Lot # 009SV because the device within the package may be incorrect. These packages incorrectly contain a 3.5mm Non Locking Cortical Screw # 00-1050-3524.accessdata.fda.gov
November 7, 201367003Class IITerminatedOrthoPediatrics ACL Reconstruction System is a pediatric and small stature adult ACL reconstruction system containing Sleeve Installation Tool Set, Part 01-1008-0040/0047, 6mm; 6.5mm, 7mm, 7.5mm, 8mm, 8.5mm, 9mm, and 10mPart # 01-1008-0040/0047, ACL Sleeve Installation/ Insertion Tool, shipped November 4, 2013 - November 6, 2013 may be etched with the wrong size.accessdata.fda.gov
September 26, 201366450Class IITerminated3.5MM LOCKING SCREW, T15 HEXALOBE, SELF TAPPING, 34MM The OrthoPediatrics Proximal Femur Plating System combines implants and instruments in one convenient system. This system offers the advantages of the osteotomy bladeThe firm identified, through complaints that the 3.5MM LOCKING SCREW packaging material was marked as a 3.5mm screw and the part number was correct but that the description indicated a 7.0mm screw. Upon investigation, it has been determined that a lot number 009U2 was packaged and mislabeled internally by OrthoPediatrics.accessdata.fda.gov
July 24, 201365828Class IITerminated3.2mm Drill Bit. This is a component within the PediLoc Locking Plate System utilized to pre-drill a hole in bone prior to placement of a bone screw.OrthoPediatrics has initiated a voluntary recall of Part # 01-1050-002, 2.5mm Drill Bit, Lot #91300335. Only drill bits that are in their original packaging are being recalled. The description on the package of this drill bit has a wrong size in the description (3.2mm). The recall affects only packaged devices still in original packaging due to misbranding oaccessdata.fda.gov
April 19, 201365091Class IITerminated90 Degree Cannulated Infant Blade Plate 25mm x 5mm x 3 Hole Product Usage: The OrthoPediatrics Locking Cannulated Blade Plate System is intended for fixation of long bone fractures and osteotomies in all pediatric subgroPost Market Surveillance of the 90 degree Cannulated Infant Blade Plate indicated that there have been five reports concerning bending of the plate intra-operatively.accessdata.fda.gov
October 18, 201263554Class IITerminated4.5mm PLEO Osteotomy Guide. OrthoPediatrics Corp. markets a pediatric, extension osteotomy bone plate system. This system is marketed under the brand name OrthoPediatrics PediLock Extension Osteotomy Plate ( PLEO ). The Complaint received from sales representative that the drill guide tubes would not screw into replenishment instrument. Upon investigation, it has been determined that the device was not manufactured to design specifications and will not function as intended.accessdata.fda.gov
September 13, 201263396Class IITerminatedTrochar Scalpel Instrument (Surgical Punch) OrthoPediatrics intramedullary rods (nails) are generally rod-shaped devices, with screw holes at either end for fixation to bone. This device is intended to be inserted into tA complaint received from sales representative that a replenishment instrument was too short. Upon investigation, it has been determined that the device was not manufactured to design specifications and will not function as intended.accessdata.fda.gov
June 14, 201262351Class IITerminatedOrthoPediatrics PediLoc Locking Plate System, 4.5mm Contour Locking Compression Femur 8 Hole Plate Right. Used for pediatric patients as indicated for pelvic, small and long bone fractures.The device is a Left 8 hole plate but is incorrectly labeled and etched as a Right device.accessdata.fda.gov
July 21, 200952852Not yet classifiedTerminatedOrthopediatrics IM Femoral Nail - 7mm x 20 cm, Rt, non-sterile, Orthopediatrics, Warsaw, IN; Part # 10-1500-021. The system is used for pediatric and small stature adult patients to stabilize fractures of the femoral shaThe potential exists for the nails to fracture during insertion of the nail.accessdata.fda.gov

Compare with other makers

Updated September 24, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.