Data / Medical devices / United States / Ortho-Clinical Diagnostics, Inc.
Ortho-Clinical Diagnostics, Inc.: FDA-registered device maker in Rochester, NY, United States, 35 510(k) clearances
Ortho-Clinical Diagnostics, Inc. is registered with the FDA (registration 1319809) in Rochester, NY, United States. It lists 50 device types. The FDA files 35 510(k) clearances under its listings, the newest dated August 13, 2021. 19 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1319809
- FEI number
- 1000305840
- Address
- 513 Technology Blvd., Rochester, NY, United States, 14626
- Owner or operator
- QuidelOrtho Corporation (2024674)
- Roles
- Manufacturer, Manufacturer for export
- First device listed
- December 15, 2022
- Registered through
- 2026
- Brand names listed
- VITROS 5600 Integrated System, VITROS 5600 Integrated System Certified, VITROS 5600 Integrated System Refurbished, VITROS A1c Slides, VITROS ACET Slides, VITROS ALB Slides, VITROS ALB-TP Slides, VITROS ALC Slides and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| August 13, 2021 | K210858 | VITROS Chemistry Products PHBR Slides | DLZ | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| June 7, 2019 | K191316 | VITROS XT Chemistry Products ALB-TP Slides | CIX | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| April 26, 2019 | K190807 | VITROS XT Chemistry Products TBIL-ALKP Slides | CIG | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| April 3, 2019 | K190520 | VITROS XT Chemistry Products GLU-Ca Slides | CGA | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| March 27, 2019 | K190490 | VITROS XT Chemistry Products TRIG-CHOL Slides | CHH | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| March 14, 2019 | K190326 | VITROS XT Chemistry Products UREA-CREA Slides | CDN | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| October 30, 2018 | K182072 | VITROS Chemistry Products Cl-Slides, VITROS Chemistry Products ECO2 Slides, VITROS Chemistry Products GLU Slides | CGZ | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| October 30, 2018 | K182063 | VITROS Chemistry Products CRBM Slides, VITROS Chemistry Products CREA Slides, VITROS Chemistry Products TBIL Slides, VITROS XT 7600 Integrated System | JFY | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| September 24, 2015 | K152433 | VITROS Chemistry Products CRP Slides; VITRO Chemistry Products Calibrator Kit 7 | DCK | Substantially Equivalent | Ortho Clinical Diagnostics | accessdata.fda.gov |
| May 31, 2013 | K130332 | VITROS CHEMISTRY PRODUCTS TRIG SLIDES | CDT | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| September 7, 2012 | K120609 | VITROS CHEMISTRY PRODUCTS DHDL SLIDES | LBS | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| October 23, 2008 | K081543 | VITROS IMMUNODIAGNOSTIC PRODUCTS TSH REAGENT PACK AND CALIBRATORS, VITROS 5600 INTEGRATED SYSTEM | JLW | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| June 30, 2008 | K081411 | VITROS CHEMISTRY PRODUCT NA+ SLIDES; VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 2 | JGS | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| December 7, 2007 | K073157 | VITROS CHEMISTRY PRODUCTS K+ SLIDES AND CALIBRATOR KIT 2 | CEM | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| September 20, 2007 | K072440 | VITROS CHEMISTRY PRODUCTS: CA SLIDES (MODEL: 145 0261), CALIBRATORS KIT 1 (MODEL: 188 2208) | CJY | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| October 28, 2004 | K042006 | VITROS CHEMISTRY PRODUCTS DHDL SLIDES, VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 25, VITROS CHEMISTRY PRODUCTS PERFORMACE | LBS | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| December 10, 2002 | K023876 | VITROS CHEMISTRY PRODUCTS MG SLIDE, VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 1 | JIX | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| December 10, 2002 | K023875 | VITROS CHEMISTRY PRODUCTS ALB SLIDE, VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 4 | CIX | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| August 30, 2001 | K012593 | VITROS CHEMISTRY PRODUCTS MAGNETIC HDL-CHOLESTEROL REAGENT, VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 2 | LBR | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| July 20, 2000 | K001885 | VITROS CHEMISTRY PRODUCTS BUN/UREA SLIDES AND VITROS CHEMISTRY PRODUCTS CALIBRATOR KIT 1 | CDN | Substantially Equivalent | Ortho-Clinical Diagnostics, Inc. | accessdata.fda.gov |
| February 18, 1997 | K964960 | VITROS CHEMISTRY PRODUCTS UPRO SLIDES | JGP | Substantially Equivalent | Johnson & Johnson Clinical Diagnostics, Inc. | accessdata.fda.gov |
| December 18, 1995 | K954933 | EKTACHEM CLINICAL CHEMISTRY SLIDE FOR ACETAMINOPHEN | LDP | Substantially Equivalent | Johnson & Johnson Clinical Diagnostics, Inc. | accessdata.fda.gov |
| January 17, 1995 | K946090 | KODAK EKTACCHEM 950IRC ANALYZER | JJE | Substantially Equivalent | Clinical Diagnostic Systems, Inc. | accessdata.fda.gov |
| October 20, 1994 | K942610 | KODAK EXTACHEM CLINICAL CHEMISTRY SLIDE DIGOXIN (DGXN) | LFM | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| March 21, 1994 | K934273 | KODAK EKTACHEM CLINICAL CHEMISTRY SLIDE ALCOHOL (ALC) | DMT | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| August 3, 1993 | K932729 | KODAK EKTACHEM CLINICAL CHEMISTRY SLIDES (PHOS) | CEO | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| January 26, 1993 | K924488 | KODAK EKTACHEM CLINICAL CHEMISTRY SLIDES (LI) | JIH | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| February 4, 1991 | K910143 | KODAK EXTACHEM CLINICAL CHEMISTRY SLIDES (FE) | JIY | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| July 16, 1990 | K902356 | KODAK EKTACHEM CLINICAL CHEMISTRY SLIDES (SALI) | DKJ | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| June 27, 1986 | K861387 | KODAK EKTACHEM CLINICAL CHEMISTRY SLIDES (CK-MB) | JHS | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| May 29, 1986 | K861367 | KODAK EKTACHEM CLINICAL CHEMISTRY SLIDES (THEO) | KLS | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| April 4, 1984 | K840606 | EKTACHEM CLINICAL CHEM. SLIDES | CIG | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| April 1, 1982 | K820723 | KODAK EKTACHEM CLINICAL CHEM. NH3 | JID | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| August 3, 1981 | K812027 | KODAK EKTACHEM CLIN. CHEM. SLIDES (AMYL) | CIW | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
| August 20, 1980 | K801649 | KODAK EKTACHEM CLINICAL CHEMISTRY SLIDES | KNK | Substantially Equivalent | Eastman Kodak Company | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| December 19, 2024 | 96031 | Class II | Ongoing | Brand Name: VITROS Product Name: VITROS 5600 Integrated System Model/Catalog Number: 6802413 (New), 6802415 (Certified/Refurbished), 6904001 (China) Software Version: version 3.8.0 or higher Product Description: In vitro | The VITROS 5600 Integrated System software versions 3.8.0 may not correctly notify users if the Signal Reagent Pack exceeds the on-board and/or shelf-life expiration date. This could result in the use of expired products, which would increase the risk of no results or erroneous results from the instrument. | accessdata.fda.gov |
| October 25, 2023 | 93378 | Class II | Ongoing | VITROS Chemistry Products ECO2 Slides-For in vitro diagnostic use only. VITROS Chemistry Products ECO2 Slides quantitatively measure total carbon dioxide (CO2) concentration in serum and plasma using VITROS 250/350/5,1 F | Ortho Clinical Diagnostics (QuidelOrtho) confirmed during routine testing that some lots from Coating 3598 of VITROS ECO2 slides included carts which may contain consecutive slides that may not function as intended. These affected slides (potentially intermittent, consecutive slides within a cart or across consecutive carts) have an abnormality which may cau | accessdata.fda.gov |
| September 12, 2023 | 93238 | Class II | Ongoing | VITROS Chemistry Products Lipase Slides, Product Codes 1668409 (contains 60 Slides per Cartridge) and 8297749 (contains 18 slides per cartridge) | Products 1668409 and 8297749 may contain VITROS Lipase Slides with an abnormality which could cause -46% to +86% bias in lipase results depending on how the slides are used. Falsely low levels could result in a missed or delayed diagnosis of acute pancreatitis and may lead to diagnostic confusion in the setting of acute abdominal symptoms. Falsely elevated l | accessdata.fda.gov |
| August 5, 2023 | 92928 | Class II | Ongoing | VITROS XT Chemistry Products TBIL-ALKP Slides | Samples containing high levels of ALKP (or an interfering substance) could deplete the available substrate in the reagent layer of a VITROS ALKP Slide and not post the substrate deleption (DP) code, which may result in the System reporting an incorrect value (lower than the actual value), which may result in missed or delayed diagnosis of liver disease. | accessdata.fda.gov |
| May 3, 2021 | 87888 | Class II | Terminated | VITROS CoV2 Ag calibrator (Product Code 6199950) - Product Usage: is a chemiluminescent immunoassay intended for the qualitative detection of SARS-CoV-2 nucleocapsid protein antigens in nasopharyngeal (NP) and anterior n | Ortho investigated and confirmed the potential for unexpected failed calibration, and condition codes associated with the calibration, when using VITROS SARS-CoV-2 Ag Reagent Pack along with VITROS Immunodiagnostic Products SARS-CoV-2 Ag Calibrator, Lot 20. | accessdata.fda.gov |
| March 26, 2021 | 87649 | Class II | Terminated | VITROS Black Reference Slides CATALOG #: J02316 - Product Usage: The Black Reference Slide is a part/ tool used in the reflectometer correction factor adjustment procedure. | Delayed results. Ortho confirmed that two lots of VITROS Black Reference Slides are incorrectly labelled as White Reference Slides. If the customer fails to notice both the product name or the unexpected color of the slides and tries to use Black Reference Slides as White Reference Slides, the Correction Factor test will fail - and the analyzer will not be a | accessdata.fda.gov |
| July 13, 2020 | 86070 | Class II | Terminated | VITROS Chemistry Products TBIL Slides- 5 PACK/300 SLDS In vitro Diagnostic quantitatively measure total bilirubin (TBIL) concentration in serum and plasma, Product code: 8159931 | Etrombopag Interference for VITROS Chemistry Products: TBIL Slides, VITROS BuBc Slides and VITROS XT TBIL-ALKP Slides | accessdata.fda.gov |
| May 11, 2020 | 85652 | Class II | Terminated | VITROS Chemistry Product AMYL Slides Reagent, AMYLASE/5 PACK/300 SLDS, Product Code 1202670, UDI # 10758750008513 - Product Usage: For in vitro diagnostic use only to quantitatively measure amylase activity in serum, pla | Multiple coatings of VITROS Chemistry Products AMYL Slides are showing imprecision on control fluids when compared to the expected within lab SD as listed on the Performance Verifier (PV) Assay Sheets. | accessdata.fda.gov |
| April 1, 2020 | 85363 | Class II | Terminated | VITROS Chemistry Products CKMB Slides, Creatine Kinase MB, Product Code 805 8232-300 slides, UDI Number 10758750004294 - Product Usage: The VITROS Chemistry Product Slides are used to measure creatine kinase MB (CK-MB) a | The Spanish and Swedish language versions of the IFU state that the assay can be tested with Plasma which is false and could result in biased results. | accessdata.fda.gov |
| September 10, 2019 | 83879 | Class II | Terminated | VITROS chemistry Products Cl- Slides, Catalog No. 6844471 (which supports Urine CL-). MicroSlides which contain reagents in a dry, multi-layered form. | Users may experience intermittent slide dispense issues with some cartridges due to the anti-backup platen failing to advance inside the cartridge. | accessdata.fda.gov |
| June 17, 2019 | 83228 | Class II | Terminated | VITROS Chemistry Products GLU Slides-Product Code:1707801. IVD VITROS Chemistry Products GLU Slides quantitatively measure glucose (GLU) concentration in serum, plasma, urine, and cerebrospinal fluid using VITROS 250/350 | Potentially Biased Results using VITROS Chemistry Products GLU Slides | accessdata.fda.gov |
| May 5, 2018 | 80436 | Class II | Terminated | VITROS Sodium Slides, Catalog # | Potential for positively biased results | accessdata.fda.gov |
| June 12, 2017 | 77613 | Class II | Terminated | VITROS Chemistry Products PHYT Slides, REF/CATALOG, Rx ONLY, IVD; Ortho-Clinical Diagnostics, Inc. For in vitro diagnostic use only. VITROS Chemistry Products PHYT Slides quantitatively measure phenytoin (PHYT) concentra | The firm identified the potential for biased results to be generated when processing VITROS PHYT Slide product with citrate plasma specimen samples. The current Instructions for Use (IFU) and Assay Summary Chart state serum, heparin plasma, and citrate plasma as acceptable specimen types for use with the PHYT assay. | accessdata.fda.gov |
| December 20, 2016 | 76119 | Class II | Terminated | VITROS Na+ Slides, (UPN 10758750004812) For in vitro diagnostic use only. VITROS Na+ Slides quantitatively measure sodium (Na+) concentration in serum, plasma, and urine using VITROS 250/350/950/5,1 FS and 4600 Chemistry | There is a potential for biased results to be generated over the 10 day on-analyzer storage limit when using VITROS Na+ Slide cartridges warmed at room temperature and loaded onto the analyzer after using the minimum warm up requirements stated in the IFU. If Quality Control (QC) results are within acceptable limits, reported results are acceptable and were | accessdata.fda.gov |
| December 8, 2016 | 75936 | Class II | Terminated | VITROS Chemistry Products UPRO Slides, UPN 10758750000593, Product Usage: Quantitative measurement of total protein concentration in urine. | There is a potential for variable negatively and positively biased urine protein results using VITROS UPRO Slides. | accessdata.fda.gov |
| October 26, 2016 | 75692 | Class III | Terminated | VITROS CRP Slides: 1) VITROS Chemistry Products CRP Slides (250 slides per sales unit), Catalog # 1926740 and 2), VITROS Chemistry Products CRP Slides (90 slides per sales unit), Catalog # 1926740 | CRP samples diluted using VITROS Chemistry Products Specialty Diluent, VITROS Chemistry Products FS Diluent Pack 3, or a sample with a low concentration of CRP had positively biased results if the endogenous level of CRP in the diluent is not subtracted from the final result. The IFUs do not provide specific instructions for how to account for endogenous CRP | accessdata.fda.gov |
| May 18, 2016 | 74355 | Class II | Terminated | VITROS Chemistry Products Ca Slides, GEN 29, REF/Product Code, Unique Device Identifier No. 10758750009114 or 20758750009111, IVD -- Sales Unit: 300 slides/pack Product Usage: For in vitro diagnostic use only. VITROS Ca | Ortho Clinical Diagnostics (OCD) confirmed a potential for biased calcium (Ca) results to be generated when using VITROS Ca Slides, GEN29, and the VITROS 250/350/950/5,1 FS, 4600 Chemistry System or the VITROS 5600 Integrated System. An increase in negatively biased calcium results complaints prompted the investigation that identified this product issue. | accessdata.fda.gov |
| November 6, 2014 | 69791 | Class II | Terminated | VITROS CHEMISTRY PRODUCTS TRIG Slides, REF, IVD For in vitro diagnostic use only. VITROS Chemistry Products TRIG Slides quantitatively measure triglyceride (TRIG) concentration in serum and plasma using VITROS 250/350/95 | Potential for biased results using the specific lot of VITROS CHEMISTRY PRODUCTS TRIG slides. | accessdata.fda.gov |
| August 20, 2014 | 69094 | Class II | Terminated | VITROS Chemistry Products PHYT (Phenytoin) Slides, REF/Product Code, IVD. For in vitro diagnostic use only. VITROS Chemistry Products PHYT Slides quantitatively measure phenytoin (PHYT) concentration in serum and plasma | Ortho Clinical Diagnostics identified a potential for biased results to be generated when using VITROS PHYT Slides, Lot 2613-0150-4913. Some positively biased results were identified during testing of a different VITROS PHYT Slide lot; the affected slides were not released for distribution. Since Lot 2613-0150-4913 was manufactured in the same event, there i | accessdata.fda.gov |
Compare with other makers
- All makers of Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl
- All makers of Enzyme Immunoassay, Carbamazepine
- All makers of Enzymatic Method, Creatinine
- All makers of Diazo Colorimetry, Bilirubin
- All makers of Analyzer, Chemistry (Photometric, Discrete), For Clinical Use
- All makers of Nitrophenylphosphate, Alkaline Phosphatase Or Isoenzymes
Updated January 21, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.