Skip to the page

Data / Medical devices / United States / Nxstage Medical, Inc.

Nxstage Medical, Inc.: FDA-registered device maker in Lawrence, MA, United States, 24 510(k) clearances

Nxstage Medical, Inc. is registered with the FDA (registration 3003464075) in Lawrence, MA, United States. It lists 11 device types. The FDA files 24 510(k) clearances under its listings, the newest dated May 15, 2026. 18 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3003464075
Address
350 Merrimack St, Lawrence, MA, United States, 01843
Owner or operator
Fresenius Medical Care Holdings, Inc. (10061218)
Roles
Complaint file establishment, Specification developer
First device listed
September 20, 2019
Registered through
2026
Brand names listed
NxStage Cartridge Express, VersiHD with GuideMe Software, ViraGuard Viral Blocking Patient Transducer Protector

Devices it lists

DeviceProduct codeClassRoleSource
Accessories, Blood Circuit, HemodialysisKOC2Complaint file establishment, Specification developeraccessdata.fda.gov
Dialysate Concentrate For Hemodialysis (Liquid Or Powder)KPO2Complaint file establishment, Specification developeraccessdata.fda.gov
Dialyzer, High Permeability With Or Without Sealed Dialysate SystemKDI2Complaint file establishment, Specification developeraccessdata.fda.gov
Monitor, Temperature, DialysisFLA2Complaint file establishment, Specification developeraccessdata.fda.gov
Needle, FistulaFIE2Complaint file establishment, Specification developeraccessdata.fda.gov
Needle, Hypodermic, Single LumenFMI2Complaint file establishment, Specification developeraccessdata.fda.gov
Protector, Transducer, DialysisFIB2Complaint file establishment, Specification developeraccessdata.fda.gov
Separator, Automated, Blood Cell And Plasma, TherapeuticLKNUComplaint file establishment, Specification developeraccessdata.fda.gov
Stand, InfusionFOX1Complaint file establishment, Specification developeraccessdata.fda.gov
Subsystem, ProportioningFKR2Complaint file establishment, Specification developeraccessdata.fda.gov
Warmer, Thermal, Infusion FluidLGZ2Complaint file establishment, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
May 15, 2026K252377NxStage System One with NxViewKDISubstantially EquivalentFresenius Medical Care Renal Therapies Group, LLCaccessdata.fda.gov
March 14, 2024K232803NxStage System One with Cartridge Express (CAR-170-E and CAR-172-E)KDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
January 18, 2024K233213NxStage PureFlow SolutionKPOSubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
August 11, 2023K230632VersiHD with GuideMe softwareKDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
May 9, 2017K170469NxStage System One PlusKDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
March 20, 2015K143313NxStage Therapeutic Plasma Exchange (TPE) CartridgeKDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
June 16, 2014K140623NXSTAGE EXPRESS FLUID WARMERFLASubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
May 19, 2014K140526NXSTAGE SYSTEM ONEKDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
May 15, 2014K140571NXSTAGE PUREFLOW SLFKRSubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
March 3, 2014K133547NXSTAGE SYSTEM ONE WITH NXVIEWKDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
April 23, 2013K122051NXSTAGE SYSTEM ONEKDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
September 19, 2011K111174NXSTAGE PUREFLOW SLFKRSubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
July 7, 2008K081043LEAK DETECTION SENSOR AND TRAY ACCESSORY KITKOCSubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
August 24, 2007K071263NXSTAGE TRAVEL WARMER, MODELS TW-400 & FWS-500KDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
December 22, 2005K053286MODIFICATION TO: NXSTAGE PUREFLOW-B SOLUTIONKPOSubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
June 24, 2005K050525NXSTAGE SYSTEM ONEKDISubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
November 26, 2003K033386NXSTAGE PUREFLOW SOLUTIONKPOSubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
October 24, 2001K012832COMFORTMATE FLUID WARMING SYSTEM, MODEL # FW-200; COMFORTMATE DISPORSABLE DISPOSABLE WARMING SET, MODEL #FWS-200LGZSubstantially EquivalentNxstage Medical, Inc.accessdata.fda.gov
January 6, 2000K990803MEDISYSTEMS BUTTONHOLE NEEDLE SETSFIESubstantially EquivalentMedisystems Corp.accessdata.fda.gov
November 25, 1998K983076MEDISYSTEMS TRANSDUCER PROTECTORFIBSubstantially EquivalentMedisystems Corp.accessdata.fda.gov
August 18, 1997K971860MEDISYSTEMS DIALYSIS PRIMING SETSKOCSubstantially EquivalentMedisystems Corp.accessdata.fda.gov
February 18, 1994K932074MEDISYSTEMS APHERESIS NEEDLE WITH GUARDFIESubstantially EquivalentMedisystems Corp.accessdata.fda.gov
June 20, 1991K910734MEDISYSTEMS HEMODIALYSIS FISTULA SETFIESubstantially EquivalentMedisystems Corp.accessdata.fda.gov
June 6, 1991K910733MEDISYSTEMS ANTI-STICK INJECTION SITE NEEDLEFMISubstantially EquivalentMedisystems Corp.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
April 28, 202596730Class IIOngoingNxStage PureFlow-B Solution. Catalog numbers: RFP-400, RFP-401, RFP-402, RFP-403, RFP-404, RFP-406, RFP-453, RFP-454, RFP-456.Potential for the perimeter seal on the small chamber of the two-chamber bag to fail causing the electrolyte fluid to splash into the face of the user when attempting to open the peel seam to mix the two chambers prior to treatment.accessdata.fda.gov
May 14, 202494641Class IIOngoingNxStage PureFlow-B Solution, Premixed Dialysate for Hemodialysis, Device Catalog Numbers RFP-400, RFP-401, RFP-402, RFP-403, RFP-404, RFP-405, RFP-406, RFP-453, RFP-454, RFP-456The smaller chamber of the two chamber bag is bursting when nurses are attempting to mix the two chambers prior to use. The electrolyte fluid in the small chamber of the NxStage PureFlow B Solution has a pH of less than 2.0. The solution can be harmful if it comes in contact with the eyes or skin, and/or as a result of a slip or fall injury due to spilled flaccessdata.fda.gov
January 29, 202493886Class IIOngoingNxStage Cartridge Express with Speedswap, Catalog No. CAR-535. An accessory device for facilitating the removal and replacement of a flow-compromised filter during treatment of acute and chronic renal failure or fluid ovProduct is recalled due to reports of blood leaking or spraying from the arterial line on the cartridge.If this failure occurs, a patient may experience uncontrolled blood loss or a healthcare professional could be exposed to infectious patient blood.accessdata.fda.gov
August 27, 201983706Class IITerminatedLow Volume Cartridge IFU (SKU CAR-125-B) used with the following devices: 1) NxStage One, Model NX1000-1; 2) NxStage VersiHD Cycler, Model Numbers: NX1000-16, and NX1000-16-A; 3) NxStage One, Model Numbers: NX1000-3 and There is a potential patient health risk while performing chronic hemodialysis treatments in the home setting with for patients with low blood volume (2.4 Liters or less in a patient with body weight of 30kg or less) when prescribing larger dialysate volumes.accessdata.fda.gov
April 11, 201982693Class IITerminatedNxStage PureFlow B Solution, REF RFP-400, M535RFP4000 Product NxStage PureFlow B Solution is indicated for use with renal replacement therapy systems that utilize sterile premixed dialysate during hemodialysis.Certain lots were mislabeled with incorrect product number.accessdata.fda.gov
October 17, 201881445Class IITerminatedNxStage PureFlow B Solution-RFP-400, Premixed Dialysate for Hemodialysis. NxStage PureFlow B Solution is indicated for use with renal replacement therapy systems that utilize sterile premixed dialysate during hemodialysiPureFlow B Solution smaller chamber of the two chamber bag can burst electrolyte fluid and cause injury if it comes in contact with the eyes or skinaccessdata.fda.gov
June 11, 201880512Class IITerminatedNxStage Express Fluid Warmer (FW-300, FW-300-A, FW-300-WW, FW-301, FW-301-A) Product Usage: The NxStage Express Fluid Warmer is an accessory to the NxStage System One used to warm therapy fluids prior to administration.There is a potential risk of electrical fire when fluid leaks into the power receptacle on the back of the warmer. The risk exists any time the warmer is plugged in. The firm has received 7 reports of smoke, sparks, or flames coming from the Express Fluid Warmer since 2016. No adverse events have been reported.accessdata.fda.gov
January 29, 201879185Class IITerminatedNxStage Dialysate Sack: 1) REF SAK-301 UDI-M535SAK3010, 2) REF SAK-302 UDI-M535SAK3020, 3) REF SAK-303 UDI-M535SAK3030, 4) REF SAK-304 UDI-M535SAK3040, 5) REF SAK-306 UDI-M535SAK3060, 6) REF SAK-307 UDI- M535SAK3070, 6) May contain endotoxin levels which have been confirmed to exceed the ANSI/AAMI quality standard dialysis fluid of 0.5 EU/ml when used to prepare product.accessdata.fda.gov
November 10, 201779276Class IITerminatedNxStage PureFlow B Solution - Premixed Dialysate for Hemodialysis with NxStage System OneUsing different fluid formulations of NxStage PureFlow B Solution at the same time during treatment may cause patient health risk. The NxStage PureFlow B Solution is for use with systems that use one premixed dialysate during hemodialysis. The original labeling did not warn against mixing dialysate formulations and did not instruct staff to verify that the faccessdata.fda.gov
October 29, 201572554Class IITerminatedNxStage System One S Cycler - Model no. NX1000-3. For home hemodialysis.Ultrafiltration Volume (UFV) may not decrease during treatment-software error. The UF pump may continue to run and remove fluid even after the target UF volume has been removedaccessdata.fda.gov
October 29, 201572543Class IITerminatedNxStage System One S Cycler (High Permeability Hemodialysis System) Model no. NX1000-5Ultrafiltration (UF) Volume software error inaccurate fluid removalaccessdata.fda.gov
May 14, 201468354Class IITerminatedNxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-301 Lactate 45, Potassium 1, Sodium 140, Calcium 3, Magnesium 1, Chloride 100, Glucose (mg/dL) 100 Batch Size (liters) 60 The SAK is one of SAK Dialysate Concentrate contain aluminum levels which exceed internal product specificationaccessdata.fda.gov
January 24, 201467405Class IITerminatedNxStage PureFlow-B Solution; Model/Catalog Number: RFP-401. Product is packaged in a case containing two individual 5L bags. The NxStage PureFlow-B Solution is indicated for use with renal replacement therapy systems thaMislabeled product.accessdata.fda.gov
March 18, 201364820Class IITerminatedNxStage PureFlow-B Solution, Model/Catalog Number: RFP-401, packaged in a case The NxStage PureFLow-B Solution is indicated for use with renal replacement therapy systems that utilize sterile premixed dialysate during heProduct may be mislabeled.accessdata.fda.gov
December 20, 201263959Class IITerminatedMedisystems 15 Gauge x 3/5 inch Buttonhole Needle Set Product Code: BH-2035PE Product Usage: Medisystems Buttonhole Needle Sets are indicated for use as an access device for dialysis and pheresis procedures using a constA total of 5 (ea) single needle pouches are mislabeled as 15 Ga x1" instead of 15 Ga x 3/5".accessdata.fda.gov
December 14, 201160807Not yet classifiedTerminatedNXStage PureFlow SL SAK-303 - 2 dialysate sacks (SAK) with concentrate for use with PureFlow SL, Rx The NxStage PureFLow SL is an optional accessory to the NxStage System One that prepares dialysate for use during hemodiReport of high conductivity failure alarms with the PureFlow SL due to excess concentrate by weight in the product (SAK) dialysate Preparation Systemaccessdata.fda.gov
July 27, 200738546Not yet classifiedTerminatedNxStage Cartridge Express, CAR-170, for hemodialysis.Potential for dialysate leaks from the cartridge during treatment.accessdata.fda.gov
April 14, 200429268Not yet classifiedTerminatedNxStage Cartridge Express. A disposable extracorporeal blood and fluid pathway and a hemo filter. Model #CAR-124, 6 units per case.Pinhole leaks on the replacement (RF) side FMP bag in certain lots of its disposable cartridge balance chambers resulting in loss of dialysate or ultrafiltrateaccessdata.fda.gov

Compare with other makers

Updated May 15, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.