NDD Medizintechnik AG: FDA-registered device maker in Zurich, Switzerland, 8 510(k) clearances
NDD Medizintechnik AG is registered with the FDA (registration 9614485) in Zurich, Switzerland. It lists 5 device types. The FDA files 8 510(k) clearances under its listings, the newest dated October 19, 2023. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 9614485
- FEI number
- 3002673652
- Address
- Technoparkstrasse 1, Zurich, Switzerland, CH-8005
- Owner or operator
- ndd Medizintechnik AG (9040235)
- Roles
- Complaint file establishment, Manufacturer, Specification developer
- First device listed
- November 20, 2007
- Registered through
- 2026
- Brand names listed
- Easy on-PC Spirometer, EasyOne Air Spirometer, EasyOne Filter FT, EasyOne Filter SP, EasyOne FlowTube, EasyOne Pro LAB Respiratory Analysis System, EasyOne Pro Respiratory Analysis System, EasyOne Pro/Pro LAB and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Calculator, Predicted Values, Pulmonary Function | BTY | 2 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Filter, Bacterial, Breathing-Circuit | CAH | 2 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Mouthpiece, Breathing | BYP | 1 | Complaint file establishment, Specification developer | accessdata.fda.gov |
| Spirometer, Diagnostic | BZG | 2 | Complaint file establishment, Manufacturer, Specification developer | accessdata.fda.gov |
| Transducer, Gas Flow | BXP | 1 | Complaint file establishment, Specification developer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| October 19, 2023 | K230178 | EasyOne Sky Spirometer | BZG | Substantially Equivalent | Ndd Medizintechnik AG | accessdata.fda.gov |
| November 22, 2022 | K221250 | EasyOne Filter | CAH | Substantially Equivalent | Ndd Medizintechnik AG | accessdata.fda.gov |
| February 22, 2017 | K161534 | EasyOne Pro Respiratory Analysis System | BTY | Substantially Equivalent | Ndd Medizintechnik AG | accessdata.fda.gov |
| January 5, 2017 | K161536 | EasyOne Air Spirometer | BZG | Substantially Equivalent | Ndd Medizintechnik AG | accessdata.fda.gov |
| September 27, 2012 | K120635 | EASYONE PRO RESPIRATORY TESTING DEVICE | BTY | Substantially Equivalent | Ndd Medizitechnik AG | accessdata.fda.gov |
| January 27, 2010 | K091428 | EASYONE PRO RESPIRATORY ANALYSIS SYSTEM | BTY | Substantially Equivalent | Ndd Medizitechnik AG | accessdata.fda.gov |
| June 2, 2009 | K090034 | EASY ON-PC SPIROMETER | BZG | Substantially Equivalent | Ndd Medizitechnik AG | accessdata.fda.gov |
| May 23, 2000 | K993921 | NDD MEDICAL TECHNOLOGIES EASYONE SPIROMETER: FRONTLINE MODEL 2000 AND DIAGNOSTIC MODEL 2001 | BZG | Substantially Equivalent | Ndd Medical Technologies | accessdata.fda.gov |
Compare with other makers
- All makers of Calculator, Predicted Values, Pulmonary Function
- All makers of Spirometer, Diagnostic
- All makers of Filter, Bacterial, Breathing-Circuit
- All makers of Transducer, Gas Flow
- All makers of Mouthpiece, Breathing
Updated October 19, 2023. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.