Skip to the page

Data / Medical devices / United States / Natus Neurology Incorporated

Natus Neurology Incorporated: FDA-registered device maker in Middleton, WI, United States, 24 510(k) clearances

Natus Neurology Incorporated is registered with the FDA (registration 3010611950) in Middleton, WI, United States. It lists 32 device types. The FDA files 24 510(k) clearances under its listings, the newest dated January 22, 2025. 15 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
3010611950
Address
3150 Pleasant View Road, Middleton, WI, United States, 53562
Owner or operator
Natus Medical Incorporated (9004873)
Roles
Complaint file establishment, Contract manufacturer, Manufacturer, Repackager or relabeler, Specification developer
First device listed
June 21, 2010
Registered through
2026
Brand names listed
025420 PMIO Patient Bedside Monitor Cable, 025430 AC Power Adapter, 025440 USB-to-RS232 Adapter Cable, 026950 14.4V Li-ion Battery, 8-04-12700, 1073 ICS Chartr EP 200 Insert 2 Ch, US Only, 8-04-12702, 1073 ICS Chartr EP 200 Insert, Bone 2 Ch, US only, 8-04-12703, 1073 ICS Chartr EP 200 Insert, Bone & TDH49 2Ch, US only, 8-04-12720, 1073 ICS Chartr EP 200 Insert, Bone & TDH49 2Ch, DS only and more

Devices it lists

DeviceProduct codeClassRoleSource
Amplifier, Physiological SignalGWL2Specification developeraccessdata.fda.gov
Amplitude-Integrated ElectroencephalographOMA2Contract manufacturer, Manufactureraccessdata.fda.gov
Automatic Event Detection Software For Full-Montage ElectroencephalographOMB2Contract manufacturer, Manufactureraccessdata.fda.gov
Automatic Event Detection Software For Polysomnograph With ElectroencephalographOLZ2Manufactureraccessdata.fda.gov
Burst Suppression Detection Software For ElectroencephalographORT2Contract manufacturer, Manufactureraccessdata.fda.gov
Cable, ElectrodeIKD2Specification developeraccessdata.fda.gov
Calibrator, Hearing Aid / Earphone And Analysis SystemsETW2Contract manufactureraccessdata.fda.gov
Device, Monitoring, Intracranial PressureGWM2Contract manufactureraccessdata.fda.gov
Device, Nerve Conduction Velocity MeasurementJXE2Manufacturer, Specification developeraccessdata.fda.gov
Electrode, CorticalGYC2Contract manufacturer, Specification developeraccessdata.fda.gov
Electrode, CutaneousGXY2Contract manufacturer, Specification developeraccessdata.fda.gov
Electrode, NeedleGXZ2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Electrode, Needle, Diagnostic ElectromyographIKT2Complaint file establishment, Repackager or relabeler, Specification developeraccessdata.fda.gov
Electromyograph, DiagnosticIKN2Manufacturer, Specification developeraccessdata.fda.gov
Full-Montage Standard ElectroencephalographGWQ2Complaint file establishment, Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Methyl Methacrylate For CranioplastyGXP2Specification developeraccessdata.fda.gov
Monitor, Blood-Flow, UltrasonicHEP2Complaint file establishment, Manufactureraccessdata.fda.gov
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)MHX2Manufactureraccessdata.fda.gov
Monitor, Ultrasonic, FetalKNG2Manufactureraccessdata.fda.gov
Monitor, Ultrasonic, NonfetalJAF2Manufactureraccessdata.fda.gov
Non-Normalizing Quantitative Electroencephalograph SoftwareOLT2Manufacturer, Specification developeraccessdata.fda.gov
Oximeter, Tissue SaturationMUD2Manufactureraccessdata.fda.gov
Reduced- Montage Standard ElectroencephalographOMC2Contract manufactureraccessdata.fda.gov
Standard Polysomnograph With ElectroencephalographOLV2Complaint file establishment, Contract manufacturer, Specification developeraccessdata.fda.gov
Stimulator, Auditory, Evoked ResponseGWJ2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
Stimulator, Electrical, Evoked ResponseGWF2Manufacturer, Specification developeraccessdata.fda.gov
Stimulator, Mechanical, Evoked ResponseGZP2Manufacturer, Specification developeraccessdata.fda.gov
Stimulator, NerveETN2Specification developeraccessdata.fda.gov
Stimulator, Photic, Evoked ResponseGWE2Contract manufacturer, Manufacturer, Specification developeraccessdata.fda.gov
System, Monitoring, PerinatalHGM2Manufactureraccessdata.fda.gov
Transducer, UltrasonicJOP2Manufactureraccessdata.fda.gov
Unit, Neonatal PhototherapyLBI2Contract manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
January 22, 2025K243982Nicolet EDXGWFSubstantially EquivalentNatus Neurology Incorporatedaccessdata.fda.gov
December 12, 2024K243495Natus Ultrapro S100 (982A0594)GWFSubstantially EquivalentNatus Neurology Incorporatedaccessdata.fda.gov
December 17, 2019K192572CNS EnvisionOLTSubstantially EquivalentMoberg Research, Inc.accessdata.fda.gov
July 20, 2018K173366NicoletOneOLZSubstantially EquivalentNatus Neurology Incorporatedaccessdata.fda.gov
December 19, 2017K172743Natus VikingQuestIKNSubstantially EquivalentNatus Neurology Incorporatedaccessdata.fda.gov
May 2, 2013K130346SYNERGY FOCUS DESKTOP VERSION; SYNERGY FOCUS LAPTOP VERSIONGWFSubstantially EquivalentNatus Neurology Incorporatedaccessdata.fda.gov
April 25, 2012K120979CAREFUSION NICOLET EDXGWFSubstantially EquivalentCarefusion 209, Inc.accessdata.fda.gov
March 15, 2012K112052CAREFUSION NICOLET EDXGWFSubstantially EquivalentCarefusion 209, Inc.accessdata.fda.gov
April 8, 2011K103140NICOLET WIRELESS EEGGWLSubstantially EquivalentCarefusion 209, Inc.accessdata.fda.gov
December 30, 2008K072964NICOLET CORTICAL STIMULATORGYCSubstantially EquivalentCardinal Health, Inc.accessdata.fda.gov
November 5, 2008K080217COMPONENT NEUROMONITORING SYSTEMOMASubstantially EquivalentMoberg Research, Inc.accessdata.fda.gov
November 6, 2006K061908NICOLETONE SYSTEM V32 AMPLIFIERGWQSubstantially EquivalentViasys Neuro Careaccessdata.fda.gov
July 12, 2002K021185NERVUS MONITOROLVSubstantially EquivalentTaugagreining HFaccessdata.fda.gov
April 18, 2002K013281VERSALAB APMHGMSubstantially EquivalentNicolet Biomedicalaccessdata.fda.gov
September 6, 2001K011818STERILE EMG ELECTRODESIKTSubstantially EquivalentNicolet Biomedical, Inc.accessdata.fda.gov
March 9, 2001K010521NICOLET VERSALABJAFSubstantially EquivalentNicolet Biomedicalaccessdata.fda.gov
August 7, 1998K982635CAREDOP IIJAFSubstantially EquivalentNicolet Biomedicalaccessdata.fda.gov
June 20, 1997K965065TECA. MILLENNIUMGWFSubstantially EquivalentMedelec , Ltd.accessdata.fda.gov
January 27, 1997K964280DG NERVUSGWQSubstantially EquivalentMedelec , Ltd.accessdata.fda.gov
May 12, 1995K944196IMWXDOP IRJAFSubstantially EquivalentImex Medical Systems, Inc.accessdata.fda.gov
August 23, 1994K942441IMEXDOP CT+JAFSubstantially EquivalentImex Medical Systems, Inc.accessdata.fda.gov
June 24, 1991K910462POCKET DOP 3HEPSubstantially EquivalentImex Medical Systems, Inc.accessdata.fda.gov
April 11, 1985K850259ELECTROENCEPHALOGRAPH EEGGWQSubstantially EquivalentNicolet Biomedical Instrumentsaccessdata.fda.gov
April 11, 1985K850108EMG SURFACE, DIGITAL RING, BAR, GROUNDING, EEGGXYSubstantially EquivalentNicolet Biomedical Instrumentsaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
February 7, 202493969Class IIOngoingTENSIVE Conductive Adhesive Gel, REF 016-401600Natus has become aware that its third-party supplier Parker Laboratories Inc. is conducting a voluntary recall related to their Tensive Conductive Adhesive Gel, Ref. 22-60 Lot Number A0623009. They have received five complaints. These customers reported that the gel is too thick, is discolored (darker than usual), and in one instance, patients reported irritaccessdata.fda.gov
February 1, 201880023Class IITerminatedNicolet Ambulatory EEGPotential to be able to import an ambulatory exam for a patient for which the exam was not started.accessdata.fda.gov
June 9, 201777569Class IITerminatedNicolet Elite 2 MHz OB Probe, Non-Fetal Monitor, Model #: X1L007, Catalog Code: N200. Intended for non-invasive support, i.e. early detection of fetal life, monitor blood flow before and after surgery, etc.Some of the Elite 2 and 3 Obstetric probes and 5 MHz Vascular Probes may exhibit excessive background noise that may mask the users ability to clearly hear heart rate and/or blood flow.accessdata.fda.gov
September 11, 201571991Class IITerminatedNicoletOne Software v5.94, Catalog/Part Number: 482-649600. The NicoletOne data acquisition and review system, either with or without synchronous digital video. The system is intended for medical purposes to record, measWhen using the NicoletOne v5.94 software, after exiting the impedance check function and returning to the EEG screen, the impedance check signal remains active in waveform, obscuring the EEG signals.accessdata.fda.gov
February 27, 201364479Class IITerminatedNicolet EEG Wireless Amplifier 32/64 Channel. Catalog/Part Numbers : 515-015400 for the 32 channel amplifier and 515-015500 for the 64 channel amplifier. Product Usage: The Nicolet Wireless EEG Amplifier is intended to bNatus Neurology Incorporated is recalling the Nicolet EEG Wireless Amplifier which may overheat and become uncomfortable to touch around the area of the on/off button. The overheating may result in discomfort ranging from too hot up to the potential for a burn.accessdata.fda.gov
December 16, 201160797Not yet classifiedTerminatedNicVue Software version 2.9.2 and 3.0.1. Medical Device Data System (MDDS) Intended use: The NicVue software is intended to be the patient database for various Nicolet applications. The NicVue software is intended to aidUnder certain work flow processes, when selecting a new patient name in NicVue, the associated exams list may not properly refresh, and may continue to display the previous patient's exams.accessdata.fda.gov
October 5, 201160223Not yet classifiedTerminatedNicoletOne Software v 5.60.2-5.71.4 with Cortical Stimulator License, Catalog/Part Number: 828-056600 Product Usage: The SSU Amplifier is used with the Cortical Stimulator Control unit which is used for functional brain CareFusion is recalling the NicoletOne Software v5.60.2-5.71.4 used with the Cortical Stimulator Control Unit. It is possible that during cortical stimulation the electrode annotation label may be incorrect on the screen and in the report when the current is correctly delivered through the selected electrodes. Also, it has been determined that the stimulus caccessdata.fda.gov
January 6, 200950875Not yet classifiedTerminatedViasys Healthcare, Sonora Transcranial Doppler (TCD) System. Model Sonara. Part Number of Units: 982A0469 Sonara Unilateral. The Sonara Transcranial Doppler system is a medical ultrasound device for noninvasively measuriInternal testing has identified several several scenarios where unexpected System lockups, shutdowns or system errors would render the Sonara unavailable for use until the Sonara can be restarted. These issues can be corrected by installing the Version 6.0 b045 software updating the Audio Driver and updating to XP Service Pack 3. Additionally, improper wirinaccessdata.fda.gov
September 16, 200849546Not yet classifiedTerminatedGSI Audera (version 2.6 software) Viasys Healthcare, Inc. Part or (Catalog) Numbers: 2001-9700, 2001-9705, 2001-9715, 2001-9720 and 2001-9725. The GSI Audera is used as part of an audiometric test battery. It can be usedGSI Audera systems requires a system software update due to issues with the Split-Screen and the Vestibular Evoked Myogenic Potential (VEMP) functions. A. Split Screen Field Correction: GSI Audera units with version 2.6 software may mislabel Auditory Evoked Potential (AEP) waveform responses with respect to the identification of the stimulus ear. When using accessdata.fda.gov
June 13, 200849350Not yet classifiedTerminatedNicoletOne 5.30.2 Software when used with CSeries amplifiers in Fixed Room LTM Configurations with patient room kits. The product is used for extended monitoring of EEG in a hospital setting. The system provides connectiNicoletOne 5.30.2 Software when used with CSeries amplifiers in Fixed Room LTM Configurations with patient room kits. Cardinal Health NeuroCare has confirmed that the 3rd party room relay connected to the A2 wall plate does not always activate if the patient event button connected to the CSeries Amplifier is pressed twice within one second.accessdata.fda.gov
June 5, 200848758Not yet classifiedTerminatedNicoletOne photic adapter cable 085-463700Cardinal Health NeuroCare is implementing a voluntary field correction to replace a quantity of photic adapter cables, part number 085-463700, used to connect the NicLED Photic Strobe option, part number 698-625500, with NicoletOne EEG system. The photic adapter cable has a wiring error which delivers a reduced voltage and results in a decreased intensity ofaccessdata.fda.gov
September 11, 200745328Not yet classifiedTerminatedViasys Healthcare NicoletOne ICU Monitor, Modular Neurodiagnostic System (containing Axiomtek Panel PC computer system), released and installed between December 2004 and March 2007 (Axiomtek Panel PC Model Number: 2147-6Display lock-up: VIASYS Healthcare NicoletOne ICU Monitor freezes up during operation when using the digital video option.accessdata.fda.gov
July 17, 200738424Not yet classifiedTerminatedBMSI "MicroJack" PN 672-510000 patient interface electrode connection device used during electroencephalography (EEG) /Epilepsy Monitoring evaluations with various EEG monitoring systems. The MicroJack is used with BMSI The BMSI "MicroJack" patient interface electrode connection device used with the EEG monitor systems was found to be mis-wired. A complainant alleged that during depth electrode EEG study of a patient in preparation for brain surgery there was an observation that was perceived as non-logical data output.accessdata.fda.gov
August 25, 200636241Not yet classifiedTerminatedNicoletOne version 5.20 software (also known as NicoletOne Version 5.2 Software) used with the NicoletOne LTM, Sleep, nEEG, vEEG and ICU monitoring Systems.A software anomaly exists in the 5.20.1038 NicoletOne LTM, Sleep, nEEG, vEEG and ICU Monitor systems using the M, and/or C series amplifiers. If this anomaly occurs, the system will display the data for channel one in all channels on NicoletOne LTM, Sleep, nEEG, vEEG or ICU Monitor systems.accessdata.fda.gov
April 28, 200635416Not yet classifiedTerminatedVIASYS Healthcare Disposable Bar Electrodes. Re-order No. 019-435600. Single Use only. Manufactured in the U.S.A. for VIASYS Healthcare, 5225 Verona Road, Bldg 2, Madison, WI USA 53711-4495..Each box contains 10 pouches The Bar Electrodes do not meet performance specification for electrode impedance. A manufacturing defect was discovered in disposable bar electrodes, part number 019-435600, lot 604664, that has the potential to reduce the amplitude of a motor or sensory nerve action potential. These possible lower amplitudes will be measured only if the bar electrode is useaccessdata.fda.gov

Compare with other makers

Updated January 22, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.