Data / Medical devices / Australia / Micro-X Ltd
Micro-X Ltd: FDA-registered device maker in Tonsley South Australia, Australia, 2 510(k) clearances
Micro-X Ltd is registered with the FDA (registration 3012855798) in Tonsley South Australia, Australia. It lists 2 device types. The FDA files 2 510(k) clearances under its listings, the newest dated May 21, 2021. 8 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3012855798
- Address
- A14 6 MAB Eastern Promenade, Tonsley South Australia, Australia, 5042
- Owner or operator
- MICRO-X LTD (10057299)
- Roles
- Contract manufacturer, Manufacturer
- First device listed
- March 16, 2018
- Registered through
- 2026
- Brand names listed
- Rover
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Solid State X-Ray Imager (Flat Panel/Digital Imager) | MQB | 2 | Manufacturer | accessdata.fda.gov |
| System, X-Ray, Mobile | IZL | 2 | Contract manufacturer, Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| May 21, 2021 | K211423 | Rover | IZL | Substantially Equivalent | Micro-X Limited | accessdata.fda.gov |
| July 17, 2020 | K201488 | Rover | IZL | Substantially Equivalent | Micro-X , Ltd. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| March 27, 2026 | 98644 | Class II | Ongoing | Rover Mobile X-ray System Model/Catalog Number: MXU-RV35 and MXU-RV71 | X-Ray generator may malfunction resulting in the X-Ray being inoperable. | accessdata.fda.gov |
| April 4, 2025 | 96638 | Class II | Ongoing | Brand Name: Rover Product Name: Mobile X-ray System Model/Catalog Number: MXU-RV71, MXU-RV35 Product Description: Rover Mobile X-rays System ("Rover") is a mobile imaging system that incorporates a self-contained X-ray g | Potential for internal fastening mechanism within generator of mobile x-Ray to fail. | accessdata.fda.gov |
| March 28, 2025 | 96518 | Class II | Ongoing | Brand Name: Rover Product Name: Mobile X-ray System Model/Catalog Number: MXU-RV71 Product Description: Rover Mobile X-rays System ("Rover") is a mobile imaging system that incorporates a self-contained X-ray generator, | Potential for early life x-ray tube failure for mobile x-ray system due to excessive thermal load on the anode. | accessdata.fda.gov |
| October 23, 2024 | 95593 | Class II | Ongoing | MICRO-X Rover Mobile X-ray System, # MXU-RV19 | During internal testing it was found that if the system is Ready to expose and the hand switch is then dropped into the stowage unit such that it lands on the prep/expose switch, the prep switch can be activated for a very short time such that the orange ring of death is displayed in the tube cooling area of the screen. The system then becomes unresponsive t | accessdata.fda.gov |
| October 22, 2024 | 95624 | Class II | Ongoing | MICRO-X Rover Mobile X-ray System, # MXU-RV35 | Mobile x-ray system receiving/storage(operation) requirements to be followed: Temp:14 to 131(50 to 86) degrees F, RH:10% to 86%(30% to 60%) allow condensation dry time, Atmospheric Pressure:50kPa to 106 kPa(70kPa to 106kPa), Altitude:-102ft to 12,000 ft, (Maximum Gradient:9 degrees Fahrenheit), which mitigate risk of capacitor malfunction, unpredictable beha | accessdata.fda.gov |
| November 28, 2023 | 95617 | Class II | Ongoing | MICRO-X Rover Mobile X-ray System, # MXU-RV35; MICRO-X Rover Mobile X-ray System, # MXU-RV71 | Mobile x-ray system can report and deliver a lower post-exposure mAs value than what set by the operator. | accessdata.fda.gov |
| May 31, 2023 | 95603 | Class II | Ongoing | MICRO-X Rover Mobile X-ray System, # MXU-RV35 | Shots were terminated by the mAs integrator; however, the 4 ms exposure time did not allow enough tolerance to achieve diagnostic exposures due to variations in hardware and how different timers are started. | accessdata.fda.gov |
| August 31, 2022 | 90839 | Class II | Ongoing | MICRO-X ROVER MOBILE X-RAY SYSTEM, MXU-RV19 | Software calibration error with product equip with a Dose Area Product (DAP) meter. This results in the product displaying the incorrect DAP meter values which may impede radiation exposure management decisions | accessdata.fda.gov |
Compare with other makers
- All makers of System, X-Ray, Mobile
- All makers of Solid State X-Ray Imager (Flat Panel/Digital Imager)
Updated April 22, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.