Skip to the page

Data / Medical devices / United States / Merge Healthcare Incorporated

Merge Healthcare Incorporated: FDA-registered device maker in Hartland, WI, United States, 17 510(k) clearances

Merge Healthcare Incorporated is registered with the FDA (registration 2183926) in Hartland, WI, United States. It lists 4 device types. The FDA files 17 510(k) clearances under its listings, the newest dated April 14, 2025. 85 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2183926
FEI number
1000116130
Address
900 Walnut Ridge Dr, Hartland, WI, United States, 53029
Owner or operator
Merge Healthcare (10024020)
Roles
Manufacturer
First device listed
June 22, 2010
Registered through
2026
Brand names listed
CADstream, IBM iConnect Access, Merge Cardio, Merge Eye Care PACS, Merge Hemo, Merge Hemo Model RCSV2, Merge OrthoCase, Merge OrthoPACS and more

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
April 14, 2025K250301Merge Universal Viewer (MUV)LLZSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
June 21, 2024K233326Merge Hemo, Model RCSV2DQKSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
January 26, 2021K203104IBM iConnect AccessLLZSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
October 17, 2019K192455Merge PACSLLZSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
September 20, 2019K192276Merge CardioLLZSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
September 25, 2018K182290IBM iConnect AccessLLZSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
December 8, 2017K173475Merge PACSLLZSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
April 7, 2016K152864Merge HemoDQKSubstantially EquivalentMerge Healthcare Incorporatedaccessdata.fda.gov
May 18, 2011K110006OIS SYMPHONY IMAGE MANAGMENT SYSTEMNFJSubstantially EquivalentOphthalmic Imaging Systemsaccessdata.fda.gov
June 23, 2010K092915CEDARA WEBACCESS, MODEL: 2.4LLZSubstantially EquivalentCedara Software Corp.accessdata.fda.gov
November 6, 2009K092954CADSTREAM VERSION 5LLZSubstantially EquivalentConfirma, Inc.accessdata.fda.gov
December 17, 2008K082421HEARTSUITE HEMODYNAMICS 7.10DQKSubstantially EquivalentEmageon, Inc.accessdata.fda.gov
September 5, 2008K082144AMICAS PACS, VERSION 6.0LLZSubstantially EquivalentAmicas, Inc.accessdata.fda.gov
December 7, 2005K053281EVMS (ENTERPRISE VISUAL MEDICAL SYSTEM SOFTWARE)LLZSubstantially EquivalentEmageon, Inc.accessdata.fda.gov
August 2, 2005K051649VERICIS CARDIOVASCULAR IMAGE AND INFORMATION SYSTEM, MODEL 4.0LLZSubstantially EquivalentCamtronics Medical Systemsaccessdata.fda.gov
August 16, 2004K041935DR SYSTEMS PACS, RELEASE 6.1LLZSubstantially EquivalentDr Systems, Inc.accessdata.fda.gov
October 22, 2002K022881CEDARA I-SOFTVIEWLLZSubstantially EquivalentCedara Software Corp.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
July 22, 202699520Class IIOngoingMerge PACS and Merge OrthoPACS, medical imaging diagnostic workstationSoftware issue may cause measurements to be displayed inaccurately.accessdata.fda.gov
June 30, 202699391Class IIOngoingMerge PACS, medical imaging diagnostic workstationThumbnails from a previously opened patient study may be displayed in the Thumbnail Bar while a different patient study is currently open.accessdata.fda.gov
August 11, 202597429Class IIOngoingMerge Hemo, Model RCSV2, Model/Catalog Number 99-01172-00, software versions 11.1 and 11.1.1 Product Description: The Merge Hemo, Model RCSV2 device is a hemodynamics recording computer system that monitors, measures, diMerge Healthcare has been informed by Schiller AG (Baar, Switzerland) of an issue with the Schiller ARGUS PB-3000 Patient Data Module (PDM) where certain units trigger an error message on the Merge Hemo Client (Pressure Sensor Defective) during non-invasive blood pressure (NIBP) measurements, specifically when the initial inflation pressure is set in the higaccessdata.fda.gov
February 19, 202596344Class IIOngoingVERICIS, Merge Cardio, Model/Catalog Number: Version 9.x, Software Version: 9.0.6 and 9.0.8; VERICIS is an integrated cardiovascular information system classified as a picture archiving and communications system.When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent with the associated primitive measurements in the final patient report.accessdata.fda.gov
July 23, 202188379Class IITerminatedMerge Hemo, Software packages 10.2, 10.3, and 10.4The firm identified a safety issue affecting the software associated with Merge Hemo versions 9.x and 10.x, used in combination with an HL7 lab interface.accessdata.fda.gov
August 6, 202086205Class IITerminatedMerge PACSMeasurements done on the Merge PACS generated MPR s may have incorrect measurements.accessdata.fda.gov
May 8, 202085633Class IITerminatedMerge Healthcare Merge Application Server Software Release and Merge Healthcare Merge Cardio Workstation Software Release - Product Usage: VERICIS is a system intended to be used to acquire, store, print, transfer, and aAn error in the calculation of the Michigan Reference Ranges can generate an inaccurate Z-Score calculation. The error may reduce the sensitivity of the Z-Score in detecting an abnormality resulting in a false negative.accessdata.fda.gov
July 11, 201983300Class IITerminatedMerge PACS versions 7.3, 7.3.1, 8.0 and 8.0.1Potential for prior thumbnails to not display in reverse chronological order and images may not scroll in reverse chronological order when mammography stacked scrolling is enabled. Merge PACS provides image manipulation tools to enable users to view and compare images such as: linking, MPR, MIP, 3D image fusion/registration of CT, MR and PET; as well as CVR accessdata.fda.gov
December 20, 201881869Class IITerminatedThe WinStation Retinal Imager, also known as Merge Eye Station. DCF-1024 & DCF-512 Digital Imaging System Product Usage: The WinStation Retinal Imager has the same intended use as other fundus cameras. It is specificallyCertain configurations of Merge Eye Station hardware may result in electrical output that exceeds the allowable limits for medical devices. Leakage current was found to exceed allowable limits in earth leakage current, touch current in a single fault condition (of open ground) and patient leakage current in a single fault condition (of open ground).accessdata.fda.gov
August 14, 201777811Class IITerminatedMerge Unity software, formerly known as DR Systems Unity PACS software. The firm name on the label is Merge Healthcare, Hartland, WI. Merge Unity is a medical image and information management system that allows viewing, The software is not identifying the patient as having atypical hyperplasia, resulting in an incorrect Gail Risk calculation.accessdata.fda.gov
August 7, 201780570Class IITerminatedMerge Unity software, formerly known as DR Systems Unity PACS software. The firm name on the label is Merge Healthcare, Hartland, WI. Merge Unity is a medical image and information management system that allows viewing, The software is not identifying the patient as having atypical hyperplasia, resulting in an incorrect Gail Risk calculation.accessdata.fda.gov
June 13, 201777627Class IITerminatedMerge Eye Care PACS Viewer 5.2 Merge Eye Care PACS is a software solution for the display, management, archive, interface and integration of ophthalmic device reports, images and data. Merge Eye Care PACS is a software sWhen the user has not set up any user preference on the sorting order to render the study images (OS/OD/etc.) and reports, the ECP may get an incorrect study index. If the user attempts to delete an image, ECP may then read that image as OS when it is, in fact, OD.accessdata.fda.gov
May 24, 201777271Class IITerminatedMerge OrthoPACS software. The firm name on the label is Merge Healthcare, Hartland, WI.Studies that have QC, PDE, or HL7 ADT updates applied may fail to propagate via telmed protocol to the destination server and may fail to import on the destination server.accessdata.fda.gov
May 24, 201777265Class IITerminatedMerge OrthoPACS software.A migrated study that has annotations will display the annotations, but when a prior study is loaded that should have annotations, the second study will not display annotations.accessdata.fda.gov
May 8, 201777249Class IITerminatedMerge PACS software. Merge PACS (Picture Archiving Communication System) is designed and marketed for soft copy reading, communication, and storage of studies produced by digital modalities, including digital mammographyWhen cut lines are shown on an image, the lines may go from being vertical and then shift to horizontal causing confusion to the physician. This may cause a misdiagnosis.accessdata.fda.gov
May 8, 201777248Class IITerminatedMerge PACS software. The firm name on the label is Merge Healthcare, Hartland, WI.Merge PACS did not show unviewed images when the last view was skipped. There is a potential risk to health of a physician misdiagnosis because not all images are available for viewing.accessdata.fda.gov
April 6, 201776847Class IITerminatedFellows "Mighty 8" Power strip (Part Number 04175-0008) and TrippLite Power strip (PS-415-HGULTRA - Part Number 13-00106-00) are two components sold as part of the Merge Hemo System.Merge is conducting a hardware recall (replacement) of Fellows "Mighty 8" Power Strip and TrippLite Power Strip due to overheat of input resistor causing the power strip to smoke.accessdata.fda.gov
January 23, 201786449Class IITerminatedMerge LISA defect in the software resulted in medications that are not associated with the patient (i.e., medications that the patient is not currently taking) appearing on their report.accessdata.fda.gov
December 9, 201675602Class IITerminatedMerge Eye Station f/k/a: DFC-1024 & DFC-512 Digital Imaging System, WinStation, and WinStation Retinal Imager distributed by Ophthalmic Imaging Systems (OIS). Versions: 11.6.0 and priorThis recall has been initiated due to an issue related to the potential accidental deletion of record(s) by an Eye Station user.accessdata.fda.gov
December 9, 201675149Class IITerminatedMerge Eye Station. f/k/a: DFC-1024 & DFC-512 Digital Imaging System, WinStation, and WinStation Retinal Imager distributed by Ophthalmic Imaging Systems (OIS). Model number 136 T1700 Capture Stations & 46 T5810 Capture SMerge received reports of Merge Eye Station being unable to capture images of the eye as expected per the intended use of the product. Merge is recalling product from the field to reduce the risk to patient health.accessdata.fda.gov
October 20, 201675270Class IITerminatedMerge, eFilm Workstation and eFilm Lite eFilm Workstation with Modules is a software application that is used for viewing medical images. eFilm Workstation with Modules receives digital images and data from various sourcA product issues happens for RF projection images. If user measures on RF image,.cal (Calibration) is not displayed and measurement is not correct. The.cal label is not displayed on the projection images after calibration is performed which should be present if the measurement is presented based on Pixel Spacing.accessdata.fda.gov
July 14, 201675267Class IITerminatedMerge RadSuite,f/k/a: Emageon Advanced Visualization, RadSuite versions 8.30.7.8, 8.30.7.9, 8.30.8, and 8.31. Advanced Visualization (Image Viewing) includes: Full featured 2D imaging, 3D surface and volume rendering, ReIt was reported by a customer that RadSuite images are not appearing as readable images. This product malfunction has the potential to result in delay in care and a possible re-exposure of the patient to radiation (x-ray).accessdata.fda.gov
May 25, 201675497Class IITerminatediConnect Access software. The firm name on the label is Merge Healthcare, Hartland, WI.Software displayed incorrect prior reports in the viewport area, only when more than one prior study (2 or more) was viewed.accessdata.fda.gov
April 15, 201677299Class IITerminatedMerge LIS software. The firm name on the label is Merge Healthcare. Merge LIS system is a complete system for ordering, managing and reporting a patient s laboratory work, from the time of order entry to the time the labThere are potential issues with results reporting for certain run-based tests. Under certain conditions, the wrong results could inadvertently be verified.accessdata.fda.gov
April 13, 201677124Class IITerminatedMerge Cardio software. The firm name on the label is Merge Healthcare, Hartland, WI. Intended to be used to acquire, store, print, transfer, and archive clinical information.Fetal patient report was automatically pulling prior measurement data for a prior fetus since the fetal study is based on the mother's MRN, resulting in the wrong fetal measurements getting referenced.accessdata.fda.gov
April 8, 201676541Class IITerminatedDR Systems Unity PACS software, now known as Merge Unity PACSReports were missing demographic header information when they were faxed to referring physicians.accessdata.fda.gov
April 8, 201676471Class IITerminatedDR Systems Unity PACS software, now known as Merge Unity PACS. Product Usage: Merge Unity PACS is a medical image and information management system that allows viewing, selection, processing, printing, telecommunicationsThe software is not adding the correct tomo image.accessdata.fda.gov
April 4, 201676974Class IITerminatedSpO2 connecting cable for Masimo LNCS sensor (Merge Part Number: HW-HEMO-00014), Product Usage: Merge Hemodynamics monitors, measures, and records physiologic data from a human patient undergoing a cardiac catheterizatioUnder certain conditions, the cables used with the Hemo system during a patient procedure could stop displaying the patient SpO2 causing a slight delay in patient care.accessdata.fda.gov
April 4, 201676910Class IITerminatediConnect Enterprise Archive (ICEA) software. The firm name on the labeling is Merge Healthcare, Hartland, WI.An error message can occur resulting in the prior studies being unavailable for viewing.accessdata.fda.gov
April 4, 201676859Class IITerminatedMerge Hemo software. The firm name on the labeling is Merge Healthcare, Hartland, WI. Merge Hemo monitors, measures, and records physiologic data from a human patient undergoing a cardiac catheterization procedureUse of the software may show an incorrect value to the user when viewing the Fractional Flow Reserve (FFR) results during recording.accessdata.fda.gov
April 4, 201676851Class IITerminatediConnect Enterprise Archive (ICEA) software. iConnect Enterprise Archive is intended for use as a vendor neutral archive for storage and communications of medical images and dataThe study is archived but cannot be opened in iConnect Access and cannot send to PACS resulting in comparison studies not being available for physician review to determine the progression of disease.accessdata.fda.gov
April 4, 201676844Class IITerminatedMerge Eye Station and Merge Eye Care PACS.During an antivirus program scan of the Eye Station or Eye Care PACS, the antivirus program may detect a newly captured image to be an unwanted file and delete the image permanently.accessdata.fda.gov
April 4, 201676768Class IITerminatediConnect Enterprise Archive software.The versions allow images to be stored without pixel data, resulting in the system not being able to present all the prior studies, which could cause a delay in treatment in determining the progression of disease.accessdata.fda.gov
April 4, 201676654Class IITerminatediConnect Enterprise Archive when used with RadSuite. The firm name on the label is Merge Healthcare.The software produced a number of "do not route" exceptions, which may result in potential patient injury or delay in diagnosis or treatment.accessdata.fda.gov
April 4, 201676594Class IITerminatedMerge PACS software. The firm name on the label is Merge Healthcare.Studies that have QC, PDE, or HL7 ADT updates applied may fail to propagate via telmed protocol to the destination server and may fail to import on the destination server.accessdata.fda.gov
April 4, 201676590Class IITerminatedMerge Cardio software. The firm name on the label is Merge Healthcare, Hartland, WI.When taking measurements from images on the Cardio workstation or from the US cart, numbers are not crossing to the report in the correct unit of measure.accessdata.fda.gov
April 4, 201676447Class IITerminatedMerge Hemo software. Product Usage: Merge Hemo is a hemodynamic monitoring system that records and displays physiological data.In some instances, the system will lock tabs within a study, even when a second user does not have the study open on a different workstation.accessdata.fda.gov
April 4, 201676431Class IITerminatedMerge Cardio software.Cardio study list does not show STAT studies without refreshing.accessdata.fda.gov
April 4, 201676401Class IITerminatedMerge Cardio software using EchoIMS. The firm name on the label is Merge Healthcare, Hartland, WI.A situation can occur allowing two physicians to access the same study report in EchoIMS when launched from the Cardio Study List without receiving the read-only notification prompt.accessdata.fda.gov
April 4, 201676312Class IITerminatedMerge Eye Station Import Utility (ESIU). The firm name on the labeling is Merge Healthcare.System locks up which may result in potential patient injury or delay in diagnosis or treatment.accessdata.fda.gov
April 4, 201676309Class IITerminatedMerge Eye Care Systems, consisting of Merge Eye Station, Merge Eye Care PACS, and Merge Eye Station Import Utility (ESIU).The system will completely stop allowing the downloading or acquisition of new images due to incompatible software application versions.accessdata.fda.gov
April 4, 201676260Class IITerminatedMerge PACS software. The firm name on the label is Merge Healthcare, Hartland, WI.Potential exists for an incorrect patient image being displayed which could result in the delay in diagnosis or treatment.accessdata.fda.gov
March 28, 201676214Class IITerminatedMerge Hemo software. Merge Hemo monitors, measures, and records physiologic data from a human patient undergoing a cardiac catheterization procedureThere is a potential connection issue when powering up the Merge Hemo Record Station and the Hemo Monitor does not communicate with the Client PC.accessdata.fda.gov
March 28, 201675957Class IITerminatedMerge Cardio software. Product Usage: Merge Cardio is a system intended to be used to acquire, store, print, transfer, and archive clinical information including images, Hemodynamic studies and reports, measurements (viaIf a reader selects Multi-study review prior to the original study completing its loading process and then immediately returns to image review of the original study, it is possible that not all current images will be present for review, which could result in incorrect treatment/diagnosis.accessdata.fda.gov
March 28, 201675914Class IITerminatedMerge Eye Station Import Utility (ESIU) when used with Merge Eye Station and Merge Eye Care PACS. The firm name on the labeling is Merge Healthcare, Hartland, WI.Eye Station images were not importing properly and were imported under "unknown" due to an issue when validating patients using only an Medical Record Number (MRN)accessdata.fda.gov
March 28, 201675825Class IITerminatedMerge Cardio software. Merge Cardio is a system intended to be used to acquire, store, print, transfer, and archive clinical information including images, Hemodynamic studies and reports, measurements (via import from DIIf images are sent without an order in the system, they will be matched with the latest order on the current patient/modality matching potentially resulting in the matching of the report to the incorrect accession number (but still associated to the correct patient).accessdata.fda.gov
March 28, 201675713Class IITerminatedMerge PACS software. Merge PACS (Picture Archiving Communication System) is designed and marketed for soft copy reading, communication and storage of studies produced by digital modalities, including digital mammography.Cut lines on the image may present horizontally rather than vertically.accessdata.fda.gov
March 28, 201675629Class IITerminatedMerge PACS software. Product Usage: Merge PACS (Picture Archiving Communication System) is designed and marketed for soft copy reading, communication and storage of studies produced by digital modalities, including digitThe software did not show unviewed images when the last view was skipped. The physician may potentially misdiagnose when not all images are available for viewing.accessdata.fda.gov
March 10, 201677086Class IITerminatedThe Schiller PB 1000, also known as Merge Hemo Patient Data Module (PDM), a major component of the Merge Hemo software.If the PDM is utilized to output a pressure for computing fractional flow reserve (FFR), the analog output may not reflect the true representation of the selected pressure waveform being provided by the PDM to the Link Assembly which provides the analog output.accessdata.fda.gov
February 9, 201675027Class IITerminatedMerge Cardio software. The firm name on the label is Merge Healthcare, Hartland, WI. Image processing system.A report can be confirmed with the incorrect patient demographics resulting in it being saved under the incorrect patient record in the Electronic Medical Record (EMR).accessdata.fda.gov
February 5, 201674776Class IITerminatedMerge PACS software. The firm name on the label is Merge Healthcare, Inc., Hartland, WI. Intended to create and display two-dimensional and three-dimensional images of anatomy from a series of digitally acquired images.When measuring a lesion on an unmagnified mammography image then performing the same measurement on an image magnified by the Hologic imager (different image), the measurements are not the same.accessdata.fda.gov
January 31, 201674919Class IITerminatedRadSuite software. The firm name on the label is Merge Healthcare, Hartland, WI.Potential for RadSuite AV viewer to skip image slices when the user presses page up or page down when the viewer displays multiple viewports and the user has mouse focused on any viewport other than the first viewport.accessdata.fda.gov
January 31, 201674510Class IITerminatedMerge OfficePACS software. The firm name on the label is Merge Healthcare, Heartland, WI.Potential data loss occurs as a result of product archiving not working properly.accessdata.fda.gov
January 30, 201675334Class IITerminatedMerge FlexConnect software, a component of Merge LIS. Merge FlexConnect is middleware used in conjunction with Merge LIS to facilitate connection to external applicationsCommunication protocols interfacing with the affected software version with some select instruments were not properly handled, preventing data captured by these instructions to be processed by the rest of the LIS software.accessdata.fda.gov
January 30, 201675239Class IITerminatedCADstream software. The firm name on the label is Merge Healthcare, Hartland, WI.The software was not presenting the PURE filter user interface message on DICOM transfer studies. If a site starts using PURE filter, the user interface message will not display. This may result in incorrect patient follow-up.accessdata.fda.gov
January 30, 201675034Class IITerminatedMerge Cardio software. Product Usage: Merge Cardio is an integrated cardiovascular information system classified as a picture archiving and communications system.Patient information in the header is only found on the first page of the report and not on the subsequent pages.accessdata.fda.gov
January 30, 201674924Class IITerminatedRadSuite software. The firm name on the label is Merge Healthcare, Hartland, WI. RadSuite provides a means to distribute, display, and store diagnostic-quality medical images in electronic format.Interventional Radiology (IR) images are stored as JPEG2k Lossless in Merge Enterprise Archive (EA) and are not displaying correctly in RadSuite.accessdata.fda.gov
January 30, 201674773Class IITerminatedMerge PACS software. Product was distributed under the AMICAS label, Brighton, MA, but labeling was later changed to Merge Healthcare, Hartland, WI.The patient name in the Halo title bar and the thumbnails do not match the name on displayed images.accessdata.fda.gov
January 30, 201674734Class IITerminatediConnect Access used with Merge PACS software provides medical specialists with access to diagnostic quality images, reports, and various types of patient data over conventional TCP/IP (e.g., internet) networks.Studies that are viewed in iConnect Access that originate on Merge PACS / Ortho PACS may not display the correct current patient demographics if there has been a PDE (Patient / Study Demographic Edit) performed after the images were ingested in PACS.accessdata.fda.gov
January 30, 201674651Class IITerminatedMerge PACS software. The firm name on the label is Merge Healthcare, Hartland, Wisconsin. Merge PACS 6.0 is software intended to create and display two-dimensional and three-dimensional images of anatomy from a series ofA migrated study that has annotations will display the annotations, but when a prior study is loaded that should have annotations, the second study will not display annotations.accessdata.fda.gov
January 30, 201674648Class IITerminatedMerge PACS software. The firm name on the label is Merge Healthcare, Hartland, WI. Intended to create and display two-dimensional and three-dimensional images of anatomy from a series of digitally acquired images.Studies coming over via telmed were missing patient's DOB, procedure, and referring physician.accessdata.fda.gov
January 30, 201674522Class IITerminatedMerge OfficePACS software. The firm name on the label is Merge Healthcare, Hartland, WI. OfficePACS is intended for the manipulation and displaying of medical images by a suitable licensed and qualified healthcare profesPotential data loss occurs as a result of the software archiving not working properly.accessdata.fda.gov
December 17, 201572978Class IITerminatedRadSuite, a picture archive and communications system. Model Numbers Versions 5.30.0, 5.30.1, 5.30.2, 5.30.2 SB0344, 5.30.3, 5.30.4, 5.30.4 HF0418E, 5.30.5, 5.30.5 HF0404E, 5.30.5 HF0413E, 5.30.5 HF390E, 5.30.5 SB0368, 5Potential incorrect Standardized Uptake Values (SUV) measurements in RadSuite.accessdata.fda.gov
November 17, 201576258Class IITerminatedMerge RadSuite software. The firm name on the label is Merge Healthcare, Hartland, WI.The values provided from the Pixel Value tool do not appear to be correct, which may result in potential patient injury or delay in diagnosis or treatment.accessdata.fda.gov
October 26, 201572661Class IITerminatedMerge Hemo with software versions 10.0 LA. Merge Hemo (formerly named HeartSuite Hemodynamics) monitors, measures, and records physiologic data from a human patient undergoing a cardiac catheterization procedure.The firm, Merge Healthcare, sent out Merge HEMO V10.0 & Merge CARDIO V10.1 software to 3 customers before the product was completely validated in house.accessdata.fda.gov
October 15, 201575876Class IITerminatedDR Systems Unity PACS software, now known as Merge Unity PACS software.The software fails to associate to the correct MG image if there are two images for the same view.accessdata.fda.gov
October 8, 201575909Class IITerminatedMerge OrthoCase software. The firm name on the label is Merge Healthcare, Hartland, WI.Measurements in the software are changing after saving a plan with a measurement result, which may result in potential patient injury or delay in diagnosis or treatment.accessdata.fda.gov
October 1, 201575714Class IITerminatedMerge Cardio software. Merge Cardio is a system intended to be used to acquire, store, print, transfer, and archive clinical information from Camtronics and other vendors systems including images, hemodynamic studies andReporting feature times out after inactivity for more than an hour sending the user back to the study list, which causes all reporting data being entered to be lost.accessdata.fda.gov
September 22, 201576719Class IITerminatedMerge Cardio software. Product Usage: Merge Cardio is a system intended to be used to acquire, store, print, transfer, and archive clinical information including images, Hemodynamic studies and reports, measurements (viaUsers can merge a device import file with an image study that already has a confirmed report, which may result in including information not present at the time of physician interpretation.accessdata.fda.gov
September 22, 201576717Class IITerminatedMerge Cardio software with Issuer of Patient ID (IPID). The firm name on the label is Merge Healthcare, Hartland, WI.For sites using the Issuer of Patient ID (IPID), the system will display the study list and images from different patients with different IPIDs as though they are for the same patient if they all have the first name, last name, and medical record number in common.accessdata.fda.gov
July 23, 201574846Class IITerminatedMerge Unity Z3D software. Merge Unity PACS (formerly DR Systems PACS) is a medical image and information management system that allows viewing, selection, processing, printing, telecommunications, and media interchange oThe software is unable to accurately determine the calcium score of scans with a slice thickness not equal to 3 mm.accessdata.fda.gov
May 31, 201575616Class IITerminatedThe Schiller PB 1000, also known as: Merge Hemo Patient Data Module (PDM), V2 model, a major component of the Merge Hemo software.Non-invasive blood pressure pumps (NIBP) voltage is not sufficient and causes the NIBP pumps to fail prior to reaching adequate initial pressure.accessdata.fda.gov
April 9, 201574853Class IITerminatedMerge RadSuite software. Radiological image processing system.When RadSuite is used with IPID (Issuer of Patient ID) as a part of the "Patient Identifier," it is possible in some circumstances that the demographics of one patient will be applied to a study or studies for another patient.accessdata.fda.gov
March 30, 201576946Class IITerminatedSchiller AG ISA CO2 Sensor (AKA: PhaseIn Unit), Merge Part Number HW-HEMO-00001. The PhaseIn Unit is an optional accessory (sold separately) to the Merge Hemo Patient Data Module (PDM). The PDM is a major component of thThe units may display the alarm "sampling line clogged" after the flow zeroing procedure that is conducted automatically 1 hour after start up. This could result in the potential of a small bias added to the CO2 measurement and affect the alarm notification.accessdata.fda.gov
March 5, 201575419Class IITerminatedMerge LIS software.There is a potential for duplicate container numbers to be created for patients.accessdata.fda.gov
January 21, 201571814Class IITerminatedMerge Hemo, 9.10, 9.20.0, 9.20.1,9.20.2, 9.30, 9.40.0, 9.40.1, 9.40.2 with Massimo PHASEIN End Tidal CO2 (EtCO2) module. Merge Hemo (formerly named HeartSuite Hemodynamics) monitors, measures, and records physiologic datA system freeze-up of the Merge Hemo system, that included the PHASEIN End Tidal CO2 unit, resulted in the user needing to move the patient to another cath lab.accessdata.fda.gov
September 29, 201469406Class IITerminatedMerge Healthcare, Merge Hemo Programmable diagnostic computer. The system comprises the Patient Data Module and the HeartSuite Hemodynamics Hemo Monitor PC. The two units are connected via a serial interface. All vital pIt has been reported that during use, the SpO2 value displayed on the Hemo Monitor may not update to reflect changes in the patient's oxygen value. It is also possible that if using the pulse rate of the SpO2 finger clip to calculate the patient's heart rate, it too may be subject to displaying a stale value.accessdata.fda.gov
August 28, 201469295Class IITerminatedeFilm Workstation 4.0 and 4.0.1. eFilm Workstation is one of the components of a PACS (Picture Archiving and Communications System). Product Usage: eFilm Workstation is a software application that is used for viewing medThere is an issue related to eFilm Workstation versions 4.0 and 4.0.1 when having multiple studies open and utilizing the thumbnail panel to select multiple series from multiple studies may lead to the selection of an incorrect study.accessdata.fda.gov
April 30, 201475564Class IITerminatedMerge Hemo software. Merge Hemo monitors, measures, and records physiologic data from a human patient undergoing a cardiac catheterization procedure. The Monitoring System is for the monitoring of vital parameters includThe application may crash during the cath lab procedure.accessdata.fda.gov
May 6, 201374815Class IITerminatedRadSuite software. The firm name on the label is Merge Healthcare, Hartland, WI.Multiple studies were missing at a customer location that never made it to the archive before watermarkingaccessdata.fda.gov
November 1, 201275158Class IITerminatedCADstream software. Product Usage: CADstream is an image processing system designed to assist in the visualization, analysis, and reporting of magnetic resonance imaging (MRI) studies. CADstream also is intended to proviAn incorrect biopsy or missed target could result if the incorrect grid is selected within the application.accessdata.fda.gov
July 2, 201274577Class IITerminatedMerge HEMO software.The International Normalized Ratio (INR) value displayed in the study report does not match the value that is imported on the pre-procedure labs screen from HL7accessdata.fda.gov
October 28, 201175425Class IITerminatedFusion Workstation.; Indicated for the transmission and review of radiological images.After a period of time running Fusion Workstation, the Hounsfield measurement tool will report incorrect values.accessdata.fda.gov
October 19, 201175161Class IITerminatedCADstream software Product Usage: CADstream is an image processing system designed to assist in the visualization, analysis, and reporting of magnetic resonance imaging (MRI) studies. CADstream also is intended to providCustomers may experience an issue with the software study preferences when changes are made to the study protocol, resulting in incorrect patient follow-up.accessdata.fda.gov
January 1, 200847526Not yet classifiedTerminatedEVMS (Enterprise Visual Medical System); Picture archiving and communications system; Model Numbers: 5.30.4, 5.30.5, 5.30.6, 5.30.7, 5.40.0 and 7.0.0.1. Emageon, Inc., Hartland, WI 53029.Miscalculation: The calculation of the standard uptake value does not include the required calibration factor/decay correction factor. The resulting value is incorrectly calculated, which may lead to incorrect interpretation of tissue density. The calculation error exists in both the software and user guide.accessdata.fda.gov

Compare with other makers

Updated August 21, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.