Data / Medical devices / United States / Mercury Medical Enterprises, LLC
Mercury Medical Enterprises, LLC: FDA-registered device maker in Clearwater, FL, United States, 21 510(k) clearances
Mercury Medical Enterprises, LLC is registered with the FDA (registration 1024404) in Clearwater, FL, United States. It lists 21 device types. The FDA files 21 510(k) clearances under its listings, the newest dated March 3, 2023. 3 recall events name it as the recalling firm (2 Class I). Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1024404
- Address
- 11300 49th St N, Clearwater, FL, United States, 33762
- Owner or operator
- Mercury Medical Enterprises, LLC (1024404)
- Roles
- Contract manufacturer, Manufacturer, Repackager or relabeler
- First device listed
- December 30, 1977
- Registered through
- 2026
- Brand names listed
- AIRWAY PRESSURE MANOMETER, AIRWAYS (MULTIPLE), ANESTHESIA CIRCUIT (MAPLESON), CLEAR ANATOMICAL FACE MASK, CPR BAG (MUTIPLE), CPR BAG (REUSABLE), DISPOSEAL, EXHALATION FILTER (CPR) and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| March 3, 2023 | K222880 | Endolumik Fluorescence Guided Gastric Calibration Tube (FG Bougie) | KNT | Substantially Equivalent | Endolumik, Inc. | accessdata.fda.gov |
| March 17, 2017 | K161250 | OC-FLEX Flexible IntraOral Cannula | CCK | Substantially Equivalent | Venture Therapeutics, Inc. | accessdata.fda.gov |
| October 17, 2014 | K142096 | T-PIECE RESUSCITATOR | BTL | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| November 22, 2013 | K121587 | BREATH SHAKE | BYI | Substantially Equivalent | Cheen Houng Ent. Co. , Ltd. | accessdata.fda.gov |
| April 6, 2010 | K093913 | MERCURY MEDICAL T-PIECE RESUSCITATOR | BTL | Substantially Equivalent | Mercury Medical, Inc. | accessdata.fda.gov |
| August 20, 2009 | K090710 | MERCURY CPAP | BYE | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| March 5, 2009 | K081266 | MERCURY MEDICAL PEEP VALVE | BYE | Substantially Equivalent | Mercury Enterprizes Dba Mercury Medical | accessdata.fda.gov |
| February 23, 2009 | K083056 | NEO-STAT CO2 <KG | CCK | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| February 3, 2004 | K032593 | MERCURY MEDICAL NEGATIVE INSPIRATORY FORCE (NIF) DISPOSABLE MONOMETER | BXR | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| July 30, 2003 | K031411 | MINI STATCO2 CO2 DETECTOR, MODEL 10-55371 | CCK | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| January 28, 2003 | K023579 | GAS SAMPLING LINES | CCK | Substantially Equivalent | Promedic, Inc. | accessdata.fda.gov |
| November 4, 2002 | K021576 | MERCURY MEDICAL STATCO2 END TIDAL CO2 DETECTOR, MODEL 10-55370 | CCK | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| November 3, 2000 | K001714 | MERCURY MEDICAL HYPERINFLATION BAG SYSTEM, MODEL 83-900-0149 | NHK | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| November 12, 1999 | K993558 | EZFLOW MAX, MODEL 1007 | CAF | Substantially Equivalent | Piper Medical Products | accessdata.fda.gov |
| April 26, 1999 | K990384 | EZFLOW CONTINUOUS NEBULIZER,MODEL 1005 | CAF | Substantially Equivalent | Piper Medical Products | accessdata.fda.gov |
| October 31, 1997 | K970756 | MERCURY MEDICAL REUSABLE CPR BAG | BTM | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| October 3, 1996 | K954490 | MERCURY MEDICAL CPR BAG EXHALATION FILTER | CAH | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| April 25, 1996 | K954486 | MERCURY AIRWAY PRESSURE MANOMETER | CAP | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| January 30, 1996 | K954866 | MERCURY CPR (COMPLETE PERSONAL RESUSCIATOR) BAG WITH EXPANDABLE RESERVOIR | BTM | Substantially Equivalent | Mercury Medical | accessdata.fda.gov |
| September 19, 1994 | K942919 | MERCURY EXPIRATORY RESISTANCE EXERCISER | BWF | Substantially Equivalent | Mercury Ent., Inc. D/B/A Mercury Medical | accessdata.fda.gov |
| May 20, 1991 | K911622 | CPR BAG | BTM | Substantially Equivalent | Merced Medical, Inc. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| December 10, 2024 | 95967 | Class I | Ongoing | Neo-Tee T-Piece Resuscitator, for pediatric emergency respiratory support, Part: 1050805, 1050808, 1050809, 1050810, 1050811, 1050814, 1050832, 1050839, 1050840, 1050841, 1050842 | Gas powered emergency resuscitator has a circuit flow controller manufactured with an undersized spring, which may cause resuscitator not reach the high and low ends of the PIP and PEEP pressure ranges, which may cause a loss of positive pressure, impacting effective ventilation of the patient. | accessdata.fda.gov |
| August 30, 2024 | 95303 | Class I | Ongoing | Neo-Tee T-Piece Resuscitator. Part Numbers 1050805, 1050832. For pediatric emergency respiratory support. | Manual resuscitator circuit flow controller may come apart due to a missing manufacturing step. | accessdata.fda.gov |
| October 22, 2015 | 72540 | Class II | Terminated | Mercury Medical Neo-Tee T-Piece Resuscitator and T-Piece Circuit. The Neo-Tee T-Piece Resuscitator is a gas powered emergency resuscitator intended to provide emergency respiratory support by means of a face mask or a tu | Incorrect use of T-Piece resuscitators will result in complete occlusion of the patient circuit and consequent failure to ventilate the patient. | accessdata.fda.gov |
Compare with other makers
- All makers of Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase
- All makers of Monitor, Airway Pressure (Includes Gauge And/Or Alarm)
- All makers of Nebulizer (Direct Patient Interface)
- All makers of Ventilator, Emergency, Manual (Resuscitator)
- All makers of Filter, Bacterial, Breathing-Circuit
- All makers of Tubes, Gastrointestinal (And Accessories)
Updated January 10, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.