Medtronic Perfusion Systems: FDA-registered device maker in Minneapolis, MN, United States, 181 510(k) clearances

Medtronic Perfusion Systems is registered with the FDA (registration 2184009) in Minneapolis, MN, United States. It lists 46 device types. The FDA files 181 510(k) clearances under its listings, the newest dated January 20, 2026. 55 recall events name it as the recalling firm (4 Class I). Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2184009
FEI number
1000116158
Address
7611 Northland Dr, Minneapolis, MN, United States, 55428
Owner or operator
Medtronic, Inc. (2112641)
Roles
Manufacturer, Manufacturer for export, Specification developer
First device listed
December 2, 1992
Registered through
2027
Brand names listed
540, 550M, 560, 68000 CARDIOBLATE, ABLATION PEN 4920501 W/PACING, ABLT PEN 49205YN W/PACE OUS18L, ACT, ACT EASY FILL DEVICE and more

Devices it lists

DeviceProduct codeClassRoleSource
Activated Whole Blood Clotting TimeJBP2Specification developeraccessdata.fda.gov
Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary BypassDTL2Manufacturer, Specification developeraccessdata.fda.gov
Analyzer, Heparin, AutomatedJOX2Manufacturer, Specification developeraccessdata.fda.gov
Apparatus, AutotransfusionCAC2Specification developeraccessdata.fda.gov
Apparatus, ElectrosurgicalHAM2Specification developeraccessdata.fda.gov
Apparatus, Suction, Single Patient Use, Portable, NonpoweredGCY1Specification developeraccessdata.fda.gov
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary BypassDWF2Manufacturer, Specification developeraccessdata.fda.gov
Catheter, Electrode Recording, Or Probe, Electrode RecordingDRF2Specification developeraccessdata.fda.gov
Catheter, PercutaneousDQY2Manufacturer, Specification developeraccessdata.fda.gov
Catheter, SteerableDRA2Specification developeraccessdata.fda.gov
Clamp, Surgical, General & Plastic SurgeryGDJ1Specification developeraccessdata.fda.gov
Console, Heart-Lung Machine, Cardiopulmonary BypassDTQ2Manufacturer, Specification developeraccessdata.fda.gov
Container, I.V.KPE2Manufactureraccessdata.fda.gov
Container, Specimen, SterileFMH1Manufactureraccessdata.fda.gov
Continuous Measurement ThermometerFLL2Manufacturer, Specification developeraccessdata.fda.gov
Control, Pump Speed, Cardiopulmonary BypassDWA2Manufacturer, Specification developeraccessdata.fda.gov
Defoamer, Cardiopulmonary BypassDTP2Manufacturer, Specification developeraccessdata.fda.gov
Device, Vascular, For Promoting EmbolizationKRD2Specification developeraccessdata.fda.gov
Electrode, Pacemaker, TemporaryLDF2Specification developeraccessdata.fda.gov
Electrosurgical, Cutting & Coagulation & AccessoriesGEI2Specification developeraccessdata.fda.gov
Filter, Blood, Cardiopulmonary Bypass, Arterial LineDTM2Manufacturer, Specification developeraccessdata.fda.gov
Filter, Blood, Cardiotomy Suction Line, Cardiopulmonary BypassJOD2Manufactureraccessdata.fda.gov
Gauge, Pressure, Coronary, Cardiopulmonary BypassDXS2Manufacturer, Specification developeraccessdata.fda.gov
Guide, Surgical, InstrumentFZX1Specification developeraccessdata.fda.gov
Heat-Exchanger, Cardiopulmonary BypassDTR2Manufacturer, Specification developeraccessdata.fda.gov
Instruments, Surgical, CardiovascularDWS1Specification developeraccessdata.fda.gov
Lavage, JetFQH2Specification developeraccessdata.fda.gov
Left Atrial Appendage Clip, ImplantablePZX2Specification developeraccessdata.fda.gov
Monitor And/Or Control, Level Sensing, Cardiopulmonary BypassDTW2Manufactureraccessdata.fda.gov
Monitor, Blood-Gas, On-Line, Cardiopulmonary BypassDRY2Manufacturer, Specification developeraccessdata.fda.gov
Oxygenator, Cardiopulmonary BypassDTZ2Manufacturer, Specification developeraccessdata.fda.gov
Pipette, DilutingGGY1Specification developeraccessdata.fda.gov
Plasma, Coagulation ControlGGN2Specification developeraccessdata.fda.gov
Probe, Blood-Flow, ExtravascularDPT2Manufacturer, Specification developeraccessdata.fda.gov
Protamine SulphateGFT2Specification developeraccessdata.fda.gov
Pump, Blood, Cardiopulmonary Bypass, Non-Roller TypeKFM2Manufacturer, Specification developeraccessdata.fda.gov
Reservoir, Blood, Cardiopulmonary BypassDTN2Manufacturer, Specification developeraccessdata.fda.gov
RetractorGAD1Specification developeraccessdata.fda.gov
Sensor, Blood-Gas, In-Line, Cardiopulmonary BypassDTY2Manufactureraccessdata.fda.gov
Single Lumen Ecmo CannulaQHW2Specification developeraccessdata.fda.gov
Stabilizer, HeartMWS1Specification developeraccessdata.fda.gov
Sucker, Cardiotomy Return, Cardiopulmonary BypassDTS2Manufactureraccessdata.fda.gov
Surgical Device, For Cutting, Coagulation, And/Or Ablation Of Tissue, Including Cardiac TissueOCL2Manufacturer for export, Specification developeraccessdata.fda.gov
System, Multipurpose For In Vitro Coagulation StudiesJPA2Specification developeraccessdata.fda.gov
Timer, Clot, AutomatedGKN2Manufacturer, Specification developeraccessdata.fda.gov
Tubing, Pump, Cardiopulmonary BypassDWE2Manufacturer, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance. Newest 100 of 181.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
January 20, 2026K253998Clearview Intracoronary ShuntsDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
January 16, 2026K251744Affinity Pixie™ Arterial Filter with Balance™ Biosurface; Affinity® Pediatric Arterial Blood FilterDTMSubstantially EquivalentMedtronicaccessdata.fda.gov
June 20, 2025K251258MC2™ Two-Stage Venous Cannula; MC2X™ Three-Stage Venous CannulaDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
July 10, 2024K240666Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811); Affinity Fusion Oxygenator with Integrated Arterial Filter and Cardiotomy/Venous Reservoir with Balance Biosurface (BB841); Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface NON STERILE (BB811-NS)DTZSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
June 12, 2024K241352Affinity NT Oxygenator and Uncoated Cardiotomy/ Venous Reservoir (541); Affinity NT Oxygenator with Balance Biosurface and Uncoated Cardiotomy/Venous Reservoir (541B)DTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
April 19, 2024K240534Bio-Medicus Life Support Catheter and IntroducerQHWSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
February 23, 2024K240190MYOtherm XP Cardioplegia Delivery System with Cortiva BioActive Surface, MYOtherm XP Cardioplegia Delivery System UncoatedDTRSubstantially EquivalentMedtronicaccessdata.fda.gov
December 7, 2023K231206DLP Silicone Coronary Artery Ostial CannulaeDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
August 30, 2023K232295LAA Exclusion SystemPZXSubstantially EquivalentSyntheon, LLCaccessdata.fda.gov
May 4, 2023K230960DLP™ Silicone Coronary Artery Ostial CannulaeDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
April 6, 2023K230640Affinity Fusion™ Oxygenator SystemDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
December 22, 2022K223508Cardioblate Gemini-s 49260 Surgical Ablation Device; Cardioblate Gemini-s 49351 Surgical Ablation DeviceOCLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
January 14, 2022K201057Bio-Medicus Life Support Catheter and IntroducerQHWSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
September 16, 2021K203111Affinity Fusion Oxygenator System, Affinity Pixie Oxygenation SystemDTZSubstantially EquivalentMedtronicaccessdata.fda.gov
July 15, 2021K201100Bio-Medicus Life Support Catheter and IntroducerDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
June 3, 2020K200514Cardioblate Gemini-s Surgical Ablation DeviceOCLSubstantially EquivalentMedtronicaccessdata.fda.gov
October 1, 2019K191526Cardioblate CryoFlex Surgical Ablation SystemOCLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
September 27, 2019K191444Affinity NT Oxygenator with Balance Biosurface, Affinity NT Oxygenator with Balance Biosurface and Uncoated Cardiotomy/Venous ReservoirDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
August 27, 2019K191077Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance Biosurface, Affinity CP Centrifugal Blood Pump with Cortive BioActive Surface, Medtronic External Drive MotorKFMSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 30, 2019K190623Cardioblate Pen Surgical Ablation Device, Cardioblate XL Pen Surgical Ablation DeviceOCLSubstantially EquivalentMedtronicaccessdata.fda.gov
May 17, 2019K191029Affinity NTTM Oxygenator (Model 511), Affinity® NT Hollow Fiber Oxygenator with Plasma Resistant Fiber (PRF) with TrilliumTM Biosurface (Model 511T), Affinity® NT Integrated CVR/Membrane Oxygenator with Plasma Resistant Fiber (Model 541), Affinity® NT Integrated CVR/Membrane Oxygenator with Plasma Resistant Fiber (Model 541-R), Affinity NT® Integrated CVR/Membrane Oxygenator with Trillium® Biosurface (Model 541T), Affinity NT® Integrated CVR/Membrane Oxygenator with Trillium® BiosurfacDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
April 12, 2019K183490Affinity NT Oxygenator, Affinity NT Oxygenator with Trillium Biosurface, Affinity NT Oxygenator with Cortiva BioActive Surface, Affinity Fusion Oxygenator with Cortiva BioActive Surface, Affinity Fusion Oxygenator with Balance BiosurfaceDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
April 3, 2019K190557Bio-Medicus Insertion KitDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
March 18, 2019K183511Affinity Pixie™ Oxygenator with Balance™ Biosurface (Model BBP211), Affinity Pixie™ Oxygenator and Cardiotomy/Venous Reservoir with Balance™ Biosurface (Model BBP241), Affinity Pixie™ Oxygenator with Cortiva™ BioActive Surface (Model CBP211), Affinity Pixie™ Oxygenator and Cardiotomy/Venous Reservoir with Cortiva™ BioActive Surface (Model CBP241)DTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
December 19, 2018K182610Valleylab FT10 Electrosurgical Platform, Cardioblate BP2 Surgical Ablation Device, Cardioblate LP Surgical Ablation DeviceOCLSubstantially EquivalentMedtronicaccessdata.fda.gov
October 19, 2018K182586DLP Aortic Root Cannula, DLP Aortic Root Cannula with Vent Line, DLP Pressure Monitoring Extension Line Adapter, DLP Cardioplegia Adapter with Pressure PortDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
August 22, 2018K181954autoLog IQ Autotransfusion SystemCACSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
March 22, 2018K180456Bio-Medicus Adult Cannulae KitDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
March 22, 2018K180453Bio-Medicus Adult Cannulae and IntroducerDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 27, 2017K171979Tubing PackDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
June 2, 2017K171308Tubing PackDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
February 10, 2017K162774MYOtherm XP Cardioplegia Delivery System with Cortiva BioActive Surface, MYOtherm XP Cardioplegia Delivery System with Cortiva BioActive Surface (Bridge System)DTRSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
February 1, 2017K162958MYOtherm XP Cardioplegia Delivery System with Trillium Biosurface; MYOtherm XP Cardioplegia Delivery System with Trillium Biosurface with Bridge; MYOtherm XP Cardioplegia Delivery System; MYOtherm XP Cardioplegia Delivery System with BridgeDTRSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
September 21, 2016K162016Affinity NT Oxygenator with Cortiva BioActive SurfaceDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 20, 2016K160091Temperature Probe, Affinity Temperature ProbeFLLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
January 15, 2016K153598Medtronic Bio-Medicus Adult Cannula KitDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
July 16, 2015K151523Uncoated Tubing and Connector ComponentsDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 27, 2015K151110Intersept Filtered Cardiotomy ReservoirDTNSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 8, 2015K150530Level Sensor, Level Sensor TapeDTWSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
April 9, 2015K150567MEDTRONIC BIO-MEDICUS CANNULA INSERTION KITDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
March 25, 2015K143083Bio-Medicus Pediatric Cannula and IntroducersDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
March 20, 2015K150422EOPA 3D Arterial CannulaDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
November 18, 2014K142673Bio-Medicus Adult Cannulae and IntroducerDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 24, 2014K142784Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface, Affinity Fusion Oxygenator with Integrated Arterial Filter and Carmeda BioActive SurfaceDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 23, 2014K133157TRI-OPTIC MEASUREMENT CELL; WITH BALANCE BIOSURFACE, WITH CARMEDA BIOACTIVE SURFACE, WITH TRILLIUM BIOSURFACE, WITH 6DRYSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
August 15, 2014K141951DLP SILICONE CORONARY ARTERY OSTIAL CANNULAEDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
June 12, 2014K141233AFFINITY PIXIE OXYGENATION SYSTEM WITH; CARMEDA BIOACTIVE SURFACE, BALANCE BIOSUFACEDTNSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 30, 2014K132730BIO-PROBE DISPOSABLE INSERT WITH; BALANCE BIOSURFACE, CARMEDA BIOACTIVE SURFACE, TRILLIUM BIOSURFACEDPTSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 22, 2014K140192CARPENTIER BI-CAVAL FEMORAL CANNULADWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 20, 2014K140165MC2 TWO-STAGE VENOUS CANNULA, OVAL MC2 TWO-STAGE VENOUS CANNULA, THIN WALL TWO-STAGE VENOUS CANNULA, MC2X THREE-STAGE VEDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
November 19, 2013K132712AFFINITY CP CENTRIFUGAL BLOOD PUMP WITH OR WITHOUT COATING, AFFINITY CP ADAPTERKFMSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 31, 2013K132995DLP RETROGRADE CORONARY SINUS PERFUSION CANNULA WITHOUT PRESSURE MONITORING LINE, DLP RETROGRADE CORONARY SINUS PERFUSIODWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 28, 2013K132972AFFINITY FUSION CARDIOTOMY/VENOUS RESERVOIR WITH BALANCE BIOSURFACEDTNSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 4, 2013K132645THORATRAK MICS RETRACTOR SYSTEM, RACK, BLADESGADSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
July 10, 2013K131269DLP CORONARY OSTIAL PERFUSION CANNULAEDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
April 1, 2013K123733CARDIOBLATE CRYOFLEX SURGICAL ABLATION SYSTEMOCLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
March 27, 2013K123762DLP RETROGRADE CORONARY SINUS PERFUSION CANNULA WITH AUTO-INFLATE CUFFDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
January 22, 2013K123314AFFINITY FUSION OXYGENATOR WITH INTEGRATED ARTERIAL FILTER AND CARMEDA BIOACTIVE SURFACEDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
January 9, 2013K122914AFFINITY FUSION CARDIOTOMY/VENOUS RESERVIOR WITH BALANCE BIOSURFACE MODEL BB841, AFFINITY FUSION CARDIOTOMY/ VENOUS RESEDTNSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
December 14, 2012K122827AFFINITY FUSION OXYGENATOR WITH INTEGRATED ARTERIAL FILTER AND BALANCE BIOSURFACE MODEL BB811DTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
December 7, 2012K122760AFFINITY AF100 ARTERIAL FILTER WITH BALANCE BIOSURFACEDTMSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
November 2, 2012K121878CARDIOBLATE CRYOFLEX SURGICAL ABLATION PROBESOCLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 19, 2012K122913AFFINITY FUSION RECIRCULATION LINE MODEL RCL841DWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
September 14, 2012K100645AFFINITY PIXIE OXYGENATION SYSTEM WITH CARMEDA BIOACTIVE SURFACE OR BALANCE BIOSURFACEDTZSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
July 25, 2012K120988DLP SINGLE STAGE VENOUS CANNULA, DLP RIGHT ANGLE SINGLE STAGE VENOUS CANNULA, DLP SINGLE STAGE VENOUS CANNULA WITH RIGHTDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
July 13, 2012K121767CARDIOBLATE GEMINI SURGICAL ABLATION DEVICEOCLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
June 14, 2012K121451CARDIOBLATE MAPS SURGICAL MAPPING, ABLATION, PACING , AND SENSING DEVICEOCLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 25, 2012K120612MEDTRONIC CLEAR INTRAVACULAR ARTERIOTOMY SHUNTDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
December 2, 2011K113235PRESSURE DISPLAY BOX,DLP DISPOSABLE PRESSURE DISPLAY SETS-NON STERILE VERSIONSDXSSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
June 28, 2011K111658AFFINITY CP CENTRIFUGAL BLLOD PUMP WITH CARMEDA BIOACTIVE SURFACEKFMSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
June 23, 2011K111657AFFINITY CP CENTRIFUGAL BLOOD PUMP WITH BALANCE BIOSURFACEKFMSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
December 16, 2010K100646AFFINITY PIXIE ARTERIAL FILTER WITH BALANCE BIOSURFACEDTMSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
October 13, 2010K101271HEMOSTASIS MANAGEMENT SYSTEM PLUS (HMS PLUS ), MODEL 305 XXJOXSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
June 22, 2010K100631AFFIITY CP CENTRIFUGAL BLOOD PUMPKFMSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 10, 2010K100274MIAR (MINIMALLY INVASIVE AORTIC ROOT) CANNULA WITH FLOW-GUARD, MODELS 11012L AND 11014LDWFSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
March 22, 2010K093535AUTOLOG AUTOTRANSFUSION SYSTEMCACSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
February 26, 2010K093203CARDIOBLATE BIPOLAR RADIOFREQUENCY SURGICAL ABLATION SYSTEM, MODELS 60831, 60832, 60841GEISubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
February 17, 2010K093650BIOTREND OXYGEN SATURATION AND HEMATOCRIT SYSTEMDTYSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
May 7, 2008K080824BIO-CONSOLE 560DWASubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
May 5, 2008K080509CARDIOBLATE 68000 GNERATOR, BP2 SURGICAL ABLATION DEVICE, LP SURGICAL ABLATION DEVICE, GEMINI-SSURGICAL ABLATION DEVICEOCLSubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
July 3, 2007K071253AFFINITY PEDIATRIC ARTERIAL FILTER, MODEL S4014 AND WITH CARMEDA BIOACTIVE SURFACE, MODEL CB4014DTMSubstantially EquivalentMedtronic Vascularaccessdata.fda.gov
June 18, 2007K070288CARDIOBLATE MONOPOLAR PEN, 60813, CARDIOBLATE MONOPOLAR XL, 60814OCLSubstantially EquivalentMedtronic Vascularaccessdata.fda.gov
May 22, 2007K070286BIO-CONSOLE, MODEL 560DWASubstantially EquivalentMedtronicaccessdata.fda.gov
April 24, 2007K070311CARDIOBLATE GEMINI SURGICAL ABLATION DEVICE, MODELS 49260 AND 49261GEISubstantially EquivalentMedtronic Vascularaccessdata.fda.gov
March 21, 2007K070213PERFORMER CBP SYSTEMDTQSubstantially EquivalentRand S.R.L.accessdata.fda.gov
June 23, 2006K061254EOPA 3D ARTERIAL CANNULA, MODELS 78220,78222,78320,783222DWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
March 15, 2006K052555MEDTRONIC PERFORMER TM CPB, MODEL R51, PCPBDTQSubstantially EquivalentRand S.R.L.accessdata.fda.gov
February 28, 2006K060400CARDIOBLATE SURGICAL ABLATION GENERATOR, MODEL 68000; CARDIOBLATE BP2 SURGICAL ABLATION DEVICE, MODEL 60831; CARDIOBLATGEISubstantially EquivalentMedtronic, Inc.accessdata.fda.gov
November 22, 2005K052524BIO-MEDICUS MULTI-STAGE VENOUS FEMORAL PERCUTANEOUS KITDWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
September 22, 2005K052372MC2X MULTI-STAGE VENOUS CANNULA, MODELS 91437, 91437CDWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
February 8, 2005K043179SELECT 3D ARTERIAL CANNULADWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
December 21, 2004K043291CARDIOBLATE DISPERSIVE ELECTRODE ADAPTER (ACCESSORY), MODEL 60884GEISubstantially EquivalentMedtronic Vascularaccessdata.fda.gov
October 18, 2004K042206PURPLE/BLACK HEPARIN ASSAY CONTROLGGNSubstantially EquivalentMedtronic Vascularaccessdata.fda.gov
October 18, 2004K042175HEPARINASE HR ACT CONTROL, MODEL 550-12GGNSubstantially EquivalentMedtronic Vascularaccessdata.fda.gov
March 19, 2004K040173PEDIATRIC AORTIC ROOT CANNULADWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
October 31, 2003K033264MALLEABLE SINGLE STAGE VENOUS CANNULA WITH CARMEDA BIOACTIVE SURFACE, MODEL CB681XX SERIESDWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
May 13, 2003K031037EOPA ELONGATED ONE-PIECE ARTERIAL CANNULA AND GUIDEWIREDWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
April 11, 2003K030696RETROGRADE CORONARY SINUS PERFUSION CANNULA WITH NO PRESSURE LINE (15 FRENCH, MANUAL AND AUTO INFLATE)DWFSubstantially EquivalentMedtronic Perfusion Systemsaccessdata.fda.gov
January 8, 2003K024069ONE PIECE PEDIATRIC ARTERIAL CANNULA, MODEL: 77006, 77106DWFSubstantially EquivalentMedtronic Vascularaccessdata.fda.gov
January 8, 2003K022272MALLEABLE SINGLE STAGE VENOUS CANNULA, MODELS 68112-68140 (15 TOTAL CODES)DWFSubstantially EquivalentMedtronic Cardiac Surgical Productsaccessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
June 24, 202699320Class IIOngoingEOPA Elongated One-Piece Arterial Cannula BLUNT 22FR, intended for use with cardiopulmonary bypass as an arterial return cannula, Model Number 77422Pinhole leaks may occur in the wire-wound body during cardiopulmonary bypass. Potential risks associated with this condition may include hypovolemia, vessel laceration or perforation, hypotension, ischemia, and organ dysfunction.accessdata.fda.gov
May 25, 202699199Class IIOngoingMedtronic DLP One-Piece Pediatric Arterial Cannula, Product Number/CFN 77010; Cardiopulmonary bypass vascular cannulaMedtronic received two complaints of loose foreign material confirmed as containing trace levels of blood.accessdata.fda.gov
May 12, 202698966Class IIOngoingOctopus Evolution Tissue Stabilizer, Model TS2000During the manufacturing process, Medtronic personnel identified an assembly issue where the tubing was incorrectly positioned. The short tube was attached to the bottom of the canister, and the long tube was attached to the top, contrary to the intended design.accessdata.fda.gov
April 21, 202698786Class IIOngoingMedtronic GUNDRY Retrograde Cannula Manual-Inflate Silicone Body 13FR, Model 94113T; Cardiopulmonary bypass vascular catheterCertain lots of product have the potential for a sterile barrier breach.accessdata.fda.gov
January 13, 202698354Class IIOngoingOctopus Nuvo Tissue Stabilizer, disposable tissue stabilization system, Product Number TSMICS1During the manufacturing, Medtronic personnel identified an assembly issue where the tubing was incorrectly positioned. The short tube was attached to the bottom of the canister, and the long tube was attached to the top, contrary to the intended design.accessdata.fda.gov
October 20, 202597912Class IIOngoingMedtronic HR-ACT (High Range Activated Clotting Time Cartridges), REF 402-03Medtronic personnel observed trace amounts of dry blood on the external carton label and Instructions for Use (IFU) in five boxes of one lot of ACT Cartridges.accessdata.fda.gov
October 3, 202597806Class IIOngoingMC3 VitalFlow Console, REF 58100; Blood pump of ecmoAs of August 6, 2025, Medtronic has received eleven reports of VitalFlow Consoles displaying an E70 error code during normal operation. When this occurs, the touch screen may become temporarily unresponsive and go blank for up to two minutes before recovering to full functionality. Importantly, the console continues to maintain set pump speed and function thaccessdata.fda.gov
September 12, 202597702Class IIOngoingAffinity NT Oxygenator, Oxygenator with Balance Biosurface and Uncoated Cardiotomy/Venous Reservoir, Product Number 541BMedtronic identified an Affinity NT Oxygenator unit with decreased CO2 gas transfer rates that did not meet performance requirements.accessdata.fda.gov
August 6, 202597295Class IOngoingDLP Left Heart Vent Catheter Malleable body and vented connector, SUCTION 12113 LV VENT 13FR, Model Number 12113The catheters may not retain their shape.accessdata.fda.gov
February 5, 202596259Class IOngoingAortic Root Cannula: 1. DLP Aortic Root Cannula A. CANNULA 11012 AR FLOWGUARD 12GA, model no 11012 B. CANNULA 11014 AR FLOWGUARD 14GA, model no. 11014 2. MiAR Cannula: A. CANNULA 11012L AR FLOWGUARD LONG 12GA, model no 1Unexpected loose material in the male luer used in the aortic root cannula has been identified. Potential harms when identified prior to use - procedure delay. Potential harm if not identified and used - stroke (reversible and irreversible).accessdata.fda.gov
December 12, 202496015Class IIOngoingDLP Pediatric One-Piece Arterial Cannulae, Model Numbers 77008 (8 Fr) and 77014 (14 Fr)Incorrect labeling for seven manufactured lots of certain models of Arterial Cannulae.accessdata.fda.gov
October 3, 202495507Class IIOngoingMedtronic DLP Aortic Root Cannula with Flow-Guard, REF 11012; for use in cardiopulmonary bypass surgeryThere is the potential for a potential sterility breach for three lots of the DLP Aortic Root Cannula due to a misaligned sealaccessdata.fda.gov
July 9, 202495152Class IIOngoingMedtronic DLP Single Stage Venous Cannulae with right angle metal tip, REF 67312During manufacturing, DLP Single Stage Venous Cannulae - straight tip (Model 66118) was incorrectly placed into a product labeled as DLP Single Stage Venous Cannulae - right angle metal tip (Model 67312).accessdata.fda.gov
May 16, 202494856Class IIOngoingTourniKwik Tourniquet Set (CFN 79012)Incorrect component placed in four manufactured lots of the TourniKwik" Tourniquet Set.accessdata.fda.gov
March 19, 202494274Class IIOngoingMedtronic Arterial Cannulae packaged as: a) DLP Curved Metal Tip Arterial Cannula 20 Fr., Model Number 80020; b) DLP Curved Metal Tip Arterial Cannula 20 Fr., Model Number 80220; c) DLP Curved Metal Tip Arterial Cannula Potential for unsealed sterile packing.accessdata.fda.gov
February 7, 202494068Class IIOngoingMedtronic DLP Vessel Cannula, Model Number REF 30000Medtronic is writing to inform you of incorrect labeling for three manufactured lots of the DLP Vessel Cannulae for the model and lot numbers listed above.accessdata.fda.gov
December 12, 202291343Class IIOngoingAffinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface, Custom Packs, REF BB811. Used in Cardiopulmonary bypass.An upward trend of complaints in which the Temperature Monitoring Adapter (TMA), located on the Affinity Fusion Oxygenator, had come loose from the oxygenator either during pre-procedure perfusion set-up or post-procedure when disassembling the perfusion circuit.accessdata.fda.gov
April 20, 202290089Class IIOngoingCardioblate" Gemini"-s Irrigated RF Surgical Ablation System; The device is placed in a plastic tray with a snap on plastic lid, the tray is placed in protective wrap, then into a sterile pouch, 1 device per carton, 1 caFirm detected an increase in complaints related to fractured jaw tips of the Cardioblate Gemini-s.accessdata.fda.gov
October 12, 202188932Class IIOngoingMedtronic Custom Perfusion kits, with the following product descriptions and corresponding model numbers: 1. CUSTOM PACK BB10Q85R FILTER (Model BB10Q85R); 2. CUSTOM PACK BB11C01R MIDI DEEP (Model BB11C01R); 3. CUSTOM PACProduct is labeled as non-pyrogenic but endotoxin testing was not performed.accessdata.fda.gov
September 27, 202188845Class IIOngoingCardioblate CryoFlex Surgical Ablation ConsoleThere is potential for intermittent electrical connectivity between the console and probe.accessdata.fda.gov
September 13, 202188685Class IIOngoingMedtronic Bio-Medicus Insertion Kits, Model number 96553, Pediatric Insertion Kit, Sterile; and Model number 96551, Venous Insertion Kit, Sterile.There was a label mix-up between two model numbers resulting in the incorrect guidewire being contained in the kits for both model numbers.accessdata.fda.gov
August 24, 202188549Class IIOngoingDLP Left Heart Vent Catheters, 16 FR. Sterile, Rx OnlyPotential for a wire protrusion through the left heart vent catheter tipaccessdata.fda.gov
April 29, 202187915Class IITerminatedMedtronic HY10Z48R2, Ctr., Custom Pack HY10Z48R2 Adult ECC 1/4, Custom Perfusion System, Sterile, Rx.Specific lots may have been manufactured with insufficient or incomplete welds.accessdata.fda.gov
March 3, 202187490Class IOngoingMedtronic Bio-Console 560 Extracorporeal Blood Pumping Console, Model Numbers: 560BC, 560BC1, 560BCS, 560BCS1, R560BCS1. Used in cardiopulmonary bypass (CPB) procedures.An electrical component within the system controller module of certain Bio-Console 560 devices may exhibit electrical failure causing the device to stop pumping. Issues observed include the pump stopping, the user interface going blank, and smoking and producing a burning odor during use.accessdata.fda.gov
February 4, 202187271Class ITerminatedMedtronic Affinity Pixie Hollow Fiber Oxygenator and Cardiotomy/Venous Reservoir with Balance Biosurface (OXYGENATOR BBP241 AFFINITY PIXIE WCVR OU). The Affinity Pixie Cardiotomy/Venous Reservoir (CVR) with Balance BiosuProducts being recalled due to potentially elevated level of bacterial endotoxin. Patients exposed to elevated levels of bacterial endotoxins may develop an acute inflammatory response.accessdata.fda.gov
November 14, 201984410Class IITerminatedMedtronic Affinity, 38um Arterial Filter, Catalog number REF 351Medtronic has identified an out of-specification condition exhibiting excess plastic (flash) in the arterial filter directly above the outlet port.accessdata.fda.gov
November 27, 201881702Class IIOngoingRESERVOIR "Y" ADAPTER, (a) BT920 (b) BT926 Suction and Anticoagulation assemblies are indicated for use with an autotransfusion system between the suction tip and reservoir.Medtronic discovered that certain Y-connectors included in the suction lines have exhibited tearing and cracking. These defects could cause the Y-connectors to leak when in use, which could result in potential blood loss and a breach in the circuit.accessdata.fda.gov
August 8, 201885821Class IITerminatedExtra corporeal circuit with bio-active surface.Affected products failed a sterilization test.accessdata.fda.gov
February 8, 201879235Class IITerminatedBIO CAL(R) Temperature Controller, Models: (a) 370, (b) 370I Product Usage: The BIO CAL(R) (unit) is a thermal transfer module designed to control patient blood temperature during cardiopulmonary bypass procedures when hMedtronic has been unable to develop a cleaning protocol to satisfy current industry concerns and expectations. As a result, an updated cleaning protocol will not be developed by Medtronic and it has been determined that the best course of action is to request BIO CAL users to discontinue use and dispose of BIO CAL devices.accessdata.fda.gov
January 16, 201879058Class IITerminatedMedtronic AFFINITY NT, Cardiotomy/Venous Reservoir (CVR) with Filter, 540 The AFFINITY(R) NT Cardiotomy/Venous Reservoir (CVR) with Filter is a single used device designed to collect and store blood during extracorporealPossible sterile barrier breach in the pouch of Affinity NT Cardiotomy Venous Reservoir stand alone uncoated and Affinity NT Cardiotomy Venous Reservoir stand alone Trillium coated products.accessdata.fda.gov
January 3, 201878977Class IITerminatedMedtronic Custom Perfusion Systems, indicated for use in the extracorporeal circuit during cardiopulmonary bypass (CPB) surgical procedures.Medtronic custom perfusion tubing packs contain Terumo OPS valves that were recalled due to a lack of flow through the valve.accessdata.fda.gov
June 22, 201777641Class IITerminatedDLP Extension Line Adapters 20 in length Used to extend cardioplegia line during cardiopulmonary bypass surgeryIdentification of small pinholes in a single packaging configuration of sterile pouches. A total of seven different products were affected.accessdata.fda.gov
February 4, 201673261Class IIITerminatedMedtronic Custom Perfusion Tubing Pack, Rx, Sterile EO. Terumo Cardiovascular Systems (Terumo CVS) has distributed an Urgent Safety Alert regarding the CD I H/S Cuvette. The cuvette is packaged into Medtronic Perfusion TMedtronic is notifying customers who have or may receive specific lots of Medtronic Perfusion Tubing Packs that include the potentially affected cuvettes manufactured by Terumo Cardiovascular Systems (Terumo CVS). Terumo Cardiovascular Systems (Terumo CVS) has distributed an Urgent Safety Alert regarding the CD I H/S Cuvette. The cuvette is packaged into Medaccessdata.fda.gov
October 28, 201572550Class IITerminatedMedtronic Perfusion Tubing Packs, Models TL7M64R3, TL7P17R1 & HY2W85R9, Sterilized using Ethylene Oxide. The Tubing Pack design and components are specified by the user, they are packaged with consideration of setup effiThis recall is being initiated due to a potential breach of the Tubing Pack Header Bags manufactured in these select lots. The seal in question is between the Tyvek and the Poly side of the header bag.accessdata.fda.gov
August 18, 201572025Class IITerminatedMEDIVATORS HEMOCOR HPH700, HPH-1400TS, HPH-1000TS. Enables the perfusionist to manage the patient's hematocrit and fluid status.Hemocor High Performance Hemoconcentrators demonstrate low ultrafiltration performance that is below product specification. These potentially affected units have been distributed as stand-alone devices and in specific lots of Medtronic Perfusion Tubing packs.accessdata.fda.gov
July 24, 201571897Class IITerminatedMedtronic EOPA Arterial Cannula, Model # 77620. Lot: 2015060544 intended to deliver oxygenated blood to the heart during cardiopulmonary bypass procedures for up to 6 hours in duration.EOPA Arterial Cannula Devices in this lot were shipped without the guidewire.accessdata.fda.gov
June 12, 201571517Class IITerminatedMedtronic DLP Femoral Arterial Cannula, models 57414, 57417, and 57421, and DLP Femoral Cannula Replacement Kit, Models 96017 and 96021. Sterilized using Ethylene Oxide. The cannula and dilator components are polyurethanMedtronic is recalling select lots of DLP Femoral Arterial Cannula product due to recent reports in which the user had difficulty or was unable to connect the cannula to the perfusion circuit tubing.accessdata.fda.gov
October 31, 201469746Class IITerminatedThe Affinity Fusion Oxygenator with Integrated Arterial Filter and Carmeda Bioactive Surface is a single-use, microporous, hollow-fiber, gas-exchange device with plasma resistant fiber and integrated heat exchanger and aMedtronic initiated an Urgent Medical Device Recall for 66 distributed Affinity FusionTM Oxygenation Systems with Carmeda Bioactive Surface due to damaged heat exchangers. Product affected by this issue is limited to model CB841 sold stand alone or incorporated in Total Systems TS1614R1 and TS1595R7. UPDATED: Recall was updated to incorporate three additionaaccessdata.fda.gov
September 9, 201159948Not yet classifiedTerminatedMedtronic Pressure Display Box, Models 66000, 64000, 63000, 60000. It is capable of measuring pressure between -100 mmHg and +500 mmHg with an accuracy of +/-5 mmHg from -100 mmHg to +300 mmHg and +/-10 mmHg from +301 toThe DFU for the Medtronic Pressure Display Box, model 66000, states that, for display readings of -100 to +300 mmHg there will be an accuracy of +/-5 mmHg, and for display readings of +301 to +500 mmHg there will be an accuracy of +/-10 mmHg. Through reports from customers, Medtronic has become aware that the Pressure Display Box may not always accurately diaccessdata.fda.gov
September 13, 201056902Not yet classifiedTerminatedMedtronic Octopus Nuvo Tissue Stabilizer, model TSMICS1. The Octopus Nuvo Tissue Stabilizer is a disposable tissue stabilization system consisting of a rigid shaft, detachable tissue stabilizer headlink and a flexible arMedtronic has received reports regarding the Octopus Nuvo Tissue Stabilizer stating that during use, the collet (a component of the device that stabilizes the head link) fractured, thereby causing immediate separation of the head link from the shaft of the device. The resulting potential hazards are that fragments of the collet could fall into the patient's accessdata.fda.gov
April 21, 201055749Not yet classifiedTerminatedHospital Grade Power Cord, UL, Part # 66319, 055476, manufactured by Electri-Cord Manufacturing Co. beginning in February 2003. The cords are a detachable unit, supplied with the instruments listed below: Medtronic Bio-CThe potential risks during the use of this power cord include electrical shock, delay in setup and therapy, interruption of therapy, device failure, and fires. Although Medtronic has received no reports of adverse events related to the affected cord, a failure may potentially lead to serious adverse health consequences, depending on the device, and therapy baccessdata.fda.gov
April 2, 201055900Not yet classifiedTerminatedMedtronic U-CLIP Double Arm Approximation Device, model V100D U-Clip, Catalog Number V100DRFRN2. Sterilized using Irradiation. The U-Clip consists of specially designed vascular clips optionally connected to needles via Medtronic received reports involving the V100D U-Clip where during handling, the release mechanism has become separated from the needle assembly. These instances of separation have occurred when pulling the clip through prosthetic material, or when grasping and releasing the clip using robotic instrumentation. While this issue does not impact performance of accessdata.fda.gov
March 23, 200951785Not yet classifiedTerminatedMedtronic One Source Pack, Catalog Numbers: ATLS21, ATLS24, ATLS2469, EC1S24, EC2S00, EC2S24, EE1S048 and EE2S21. Kits are packaging convenience kits containing previously released sterile-pack products and accessories.Medtronic has identified a small number of One Source Kits and MAXPAC/Total System lots with incorrect Use Before Dates on the outer kit package label. The Use Before Date on the outer label of the kit/pack does not accurately reflect the Use Before Date of the components within the kit/pack. For affected product, the outer label lists a date which exceeds taccessdata.fda.gov
February 25, 200951952Not yet classifiedTerminatedMedtronic, Transfer Spike, Blood Processing Accessory, REF BT945, Sequestration KitsSterility may be compromised. Non-vented caps that connect to the 3-way stopcock attached to the transfer spike could prevent Ethylene Oxide from contacting the inside surfaces of the stopcock during sterilization, leading to a potentially non-sterile product. Use of the product may cause serious health consequences from potential sepsis/infection and the asaccessdata.fda.gov
September 29, 200850173Not yet classifiedTerminatedDLP(R) Pericardial/Intracardiac Sump Cannulae, 20 Fr., P/N: 12112. This product is intended for draining the pericardial sac or the cardiac chambers.Separates: Six complaints were received from two locations. In all cases the sump tip assembly separated from the tubing during device removal and had to be retrieved from the patient. There were no adverse events affecting these patients.accessdata.fda.gov
May 9, 200848100Not yet classifiedTerminatedMedtronic AFFINITY NT Hollow Fiber Oxygenator with Carmeda BioActive Surface, CB511, with Plasma Resistant Fiber. Single Use gas exchange device for Cardiopulmonary Bypass. Catalog Number: 71166Medtronic is recalling selected Carmeda-coated cardiopulmonary bypass (CPB) products (e.g., oxygenators, reservoirs, pumps, cannulae and tubing packs) that were manufactured with contaminated heparin. Medtronic's heparin supplier recently reported that it had provided some batches to Medtronic that were contaminated with oversulfated chondroitin sulfate (OSCaccessdata.fda.gov
May 7, 200848101Not yet classifiedTerminatedMedtronic Trillium AFFINITY NT, 511T, Hollow Fiber Oxygenator with Trillium Biopassive Surface, with Plasma Resistant Fiber. MODEL Numbers: 95215, 95216, 95217, 95249, 95250, 95252, 0H46R28, 0M81R41, 0R35R13, 0Y95R22, 17Medtronic is advising that certain Trillium-coated Medtronic cardiopulmonary bypass (CBP) products (e.g., oxygenators, reservoirs, pumps and tubing packs) were manufactured with heparin batches contaminated with oversulfated chondroitin sulfate (OSCS). Based upon currently available information, Medtronic has determined that Medtronic Trillium-coated productaccessdata.fda.gov
October 1, 200745485Not yet classifiedTerminatedMedtronic Trillium Affinity NT, 541T, Integrated CVR/Membrane Oxygenator (Plasma Resistant Fiber [PRF] Medtronic, Inc., Minneapolis, MN 55432-5604.Unnaproved Component Resin: Affinity NT Integrated CVR Membrane Oxygenators and EL 240 Autotransfusion Blood Collection Reservoirs contain components made from an unapproved resinaccessdata.fda.gov
August 1, 200738485Not yet classifiedTerminatedMedtronic Intersept 3608 Sterile tubing (8') 1/2 x 3/32 in. Quantity 10, Lot 7626621, Use by 2009-07-31. Manufacturer: Medtronic, Inc. Minneapolis, MN 55432-5604 USA. Different components and tubing sets are included witMedtronic Custom Tubing Packs might have open header bag seals.accessdata.fda.gov
June 4, 200738154Not yet classifiedTerminatedMedtronic Performer CPB-Universal R2100375. Catologue Number R5100052. The Performer CPB System is an electromechanical extracorporeal support device used during cardiopulmonary bypass procedures. Manufactured by: RanD SDevice failure requiring use of back up systems (malfunctioning printed circuit board (PCB))accessdata.fda.gov
April 18, 200737273Not yet classifiedTerminatedMedtronic Intersept Filtered Cardiotomy Reservoir, Model 1351, Non-pyrogenic, Sterile, Manufacturer: Medtronic, Inc., Minneapolis, MNPyrogen Levels detected above specification: The product contains a pyrogen level above Medtronic''s internal specifications while the product is labeled as nonpyrogenic.accessdata.fda.gov
January 2, 200737079Not yet classifiedTerminatedMedtronic 2T10R1 Intersept Custom Tubing Pack. Pack 2T10R1 consists of two PVC lines; one of them is 132 inch in length and is capped. The second line is 102 inch in length and has a one way vacuum relief valve assembledOne lot of Custom Perfusion Sets, Catalog 2T10R1 was incorrectly assembled. The one way vacuum relief valve on the 102 inch line is attached backwards, thus preventing flow.accessdata.fda.gov
September 13, 200636333Not yet classifiedTerminatedMedtronic Intersept Custom Tubing Pack. Do Not Reuse. The design and components of this product were specified by the user from an array of components and designs offered by the manufacturer. Any change in the cardiopulmAn out of specification condition exists with the tapered tubing found in some Custom Tubing Packs. The wall thickness is undersized and does not meet specifications.accessdata.fda.gov
March 25, 200531477Not yet classifiedTerminatedMedtronic Custom Packs and Total System Packs. Pack can contain a number of different components specified by the customer and individualized for their bypass circuit set up requirements. Intersept Custom Tubing Pack, StSome warehouse inventory of Custom Pack product bags were found with ruptured seals. The seals were partially opened in the center of the bag's Tyvek edge. Since this bag is used to enclose and seal the custom pack assembly & had been sterilized, the ruptured seal breaches the sterility barrier for the package.accessdata.fda.gov
March 25, 200428638Not yet classifiedTerminatedMedtronic Trillium Affinity NT Integrated-CVR Membrance Oxygenator and Cardiotomy Venous Reservoir with Trillium Biopassive Surface (on the oxygenator), Model 541T-RAn incorrect date of manufacture and incorrect use-by date were printed on the labels of the pouches used for the product.accessdata.fda.gov

Compare with other makers

Updated July 27, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.