Data / Medical devices / Canada / Medtronic CryoCath LP
Medtronic CryoCath LP: FDA-registered device maker in Pointe-Claire Quebec, Canada, 4 510(k) clearances and 3 PMA approvals
Medtronic CryoCath LP is registered with the FDA (registration 3002648230) in Pointe-Claire Quebec, Canada. It lists 5 device types. The FDA files 4 510(k) clearances and 3 PMA approvals under its listings, the newest dated December 13, 2023. 1 recall event names it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3002648230
- Address
- 9000 Autoroute Transcanadienne, Pointe-Claire Quebec, Canada, H9R 5Z8
- Owner or operator
- Medtronic, Inc. (2112641)
- Roles
- Manufacturer
- First device listed
- March 28, 2013
- Registered through
- 2026
- Brand names listed
- Arctic Front Advance ProTM, Arctic Front Advance cardiac cryoablation catheter, Coaxial Cable, Cryoconsole, ECG Cable, FlexCath Advance, FlexCath Advance Steerable Sheath and Dilator, FlexCath Select and more
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Cardiac Ablation Percutaneous Catheter | LPB | 3 | Manufacturer | accessdata.fda.gov |
| Catheter, Percutaneous, Cardiac Ablation, For Treatment Of Atrial Fibrillation | OAE | 3 | Manufacturer | accessdata.fda.gov |
| Catheter, Steerable | DRA | 2 | Manufacturer | accessdata.fda.gov |
| Introducer, Catheter | DYB | 2 | Manufacturer | accessdata.fda.gov |
| Percutaneous Cardiac Ablation Catheter For Treatment Of Atrial Fibrillation With Irreversible Electroporation | QZI | 3 | Manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| November 13, 2020 | K202620 | FlexCath Advance Steerable Sheath and Dilator | DRA | Substantially Equivalent | Medtronic Cryocath, LP | accessdata.fda.gov |
| November 26, 2018 | K183174 | FlexCath Advance Steerable Sheath and Dilator | DRA | Substantially Equivalent | Medtronic Cryocath, LP | accessdata.fda.gov |
| February 2, 2017 | K163268 | FlexCath Select Steerable Shealth and Dilator | DYB | Substantially Equivalent | Medtronic Cryocath, LP | accessdata.fda.gov |
| December 27, 2012 | K123591 | FLEXCATH ADVANCE STEERABLE SHEATH (12 FRENCH) | DRA | Substantially Equivalent | Medtronic Cryocath, LP | accessdata.fda.gov |
PMA approvals
Premarket approvals this establishment lists, with the supplements the FDA has decided since.
| Approved | PMA number | Device | Product code | Supplements | Latest decision | Source |
|---|---|---|---|---|---|---|
| December 13, 2023 | P230017 | PulseSelect Pulsed Field Ablation (PFA) system | QZI | 11 | June 30, 2026 | accessdata.fda.gov |
| December 17, 2010 | P100010 | ARCTIC FRONT CRYOCATHETER SYSTEM | OAE | 151 | September 25, 2026 | accessdata.fda.gov |
| April 17, 2003 | P020045 | 7F FREEZOR CARDIAC CRYOABLATION CATHETER AND CCT.2 CRYOCONSOLE SYSTEM | LPB | 102 | April 23, 2026 | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| August 4, 2006 | 36087 | Not yet classified | Terminated | 7F Freezor Cardiac Cryoablation catheter, REF # 207F1. CryoCath Technologies Inc. | Outer cartons of catheters were mislabeled with two different reference numbers. The front of the package showed the correct reference number; 207F1, however the section on the top of the box incorrectly referenced 207F3. All inside labels (inside the box and affixed on device pouches) showed the correct reference number, 207F1. | accessdata.fda.gov |
Compare with other makers
- All makers of Cardiac Ablation Percutaneous Catheter
- All makers of Catheter, Steerable
- All makers of Catheter, Percutaneous, Cardiac Ablation, For Treatment Of Atrial Fibrillation
- All makers of Percutaneous Cardiac Ablation Catheter For Treatment Of Atrial Fibrillation With Irreversible Electroporation
- All makers of Introducer, Catheter
Updated June 30, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.