Skip to the page

Data / Medical devices / United States / Medivance, Inc.

Medivance, Inc.: FDA-registered device maker in Louisville, CO, United States, 5 510(k) clearances

Medivance, Inc. is registered with the FDA (registration 1725056) in Louisville, CO, United States. It lists 2 device types. The FDA files 5 510(k) clearances under its listings, the newest dated October 24, 2025. 3 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1725056
FEI number
3003329224
Address
321 South Taylor Avenue Suite 200, Louisville, CO, United States, 80027
Owner or operator
C. R. Bard, Inc. (2212754)
Roles
Specification developer
First device listed
January 8, 2015
Registered through
2027
Brand names listed
Arctic Sun Cleaning Solution, Arctic Sun Stat Temperature Management System, Arctic Sun Temperature Management System, Arctic Sun Temperature Management System (Model 5000), ArcticGel Pads

Devices it lists

DeviceProduct codeClassRoleSource
Disinfectant, Medical DevicesLRJ1Specification developeraccessdata.fda.gov
System, Thermal RegulatingDWJ2Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
October 24, 2025K251974Arctic Sun Temperature Management System (Model 5000)DWJSubstantially EquivalentMedivance, Inc.accessdata.fda.gov
April 30, 2025K243942Arctic Sun Stat Temperature Management SystemDWJSubstantially EquivalentMedivance, Inc.accessdata.fda.gov
February 28, 2020K200225Arctic Sun Stat Temperature Management SystemDWJSubstantially EquivalentMedivance, Inc.accessdata.fda.gov
September 2, 2016K161602Arctic Sun Temperature Management SystemDWJSubstantially EquivalentMedivance, Inc.accessdata.fda.gov
December 18, 2014K142702Arctic Sun Temperature Management System, ArcticGel Pads (Universal, XXS, XS, S, M and L), Small Universal ArcticGel Pad, Neonatal ArcticGel PadDWJSubstantially EquivalentMedivance, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
June 27, 202494881Class IIOngoingArctic Sun Temperature Management Systems, Name/REF: Arctic Sun STAT, NA/6000-00-00; Arctic Sun STAT Loaner, NA/6000-00-00L; Arctic Sun Stat EU UK/600001; Arctic Sun Stat Taiwan/600006; Arctic Sun Stat Japan/600020; ArctIf temperature management system fails to reach correct target water temperature while device is operating in patient control mode, due to sudden patient temperature changes/interruption in water flow/blockage of air flow by an obstruction or dirty filter, then system may not alert, and alarm absence may lead to hypothermia or hyperthermia, so a software updaccessdata.fda.gov
February 16, 202494030Class IIOngoingMedivance Neonatal ArcticGel Pads, REF: 31802, 3180202, 31802CNeonatal pads are experiencing reduced water flow, which may reduce or prevent water heating or cooling performance of the pads that are part of a temperature management system.accessdata.fda.gov
January 5, 200530896Not yet classifiedTerminatedArctic Sun Temperature Management SystemPotential for an inaccuracy of the primary patient temperature reading that is used to monitor and control patient temperature.accessdata.fda.gov

Compare with other makers

Updated October 24, 2025. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.