Data / Medical devices / United States / MC3, Inc.
MC3, Inc.: FDA-registered device maker in Dexter, MI, United States, 13 510(k) clearances
MC3, Inc. is registered with the FDA (registration 3011468686) in Dexter, MI, United States. It lists 10 device types. The FDA files 13 510(k) clearances under its listings, the newest dated July 31, 2026. 1 recall event names it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 3011468686
- Address
- 2555 Bishop Circle West, Dexter, MI, United States, 48130
- Owner or operator
- Medtronic, Inc. (2112641)
- Roles
- Complaint file establishment, Manufacturer, Manufacturer for export, Specification developer
- First device listed
- December 21, 1992
- Registered through
- 2027
- Brand names listed
- Bio-Medicus Life Support Catheter and Introducer, Crescent RA Dual Lumen Catheter, Crescent Jugular Dual Lumen Catheter, MC3 Nautilus ECMO Oxygenator with Balance Biosuface, MC3 Nautilus Oxygenator Holder, MC3 Nautilus Smart ECMO Module with Balance Biosuface, MC3 Vasular Access Kit, Nautilus VF ECMO Oxygenator and more
Devices it lists
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| July 31, 2026 | K261335 | VitalFlow Set with Balance Biosurface | QJZ | Substantially Equivalent | Medtronic, Inc. | accessdata.fda.gov |
| January 15, 2026 | K251831 | Bio-Medicus Life Support Catheter and Introducer | QHW | Substantially Equivalent | Medtronic, Inc. | accessdata.fda.gov |
| May 20, 2025 | K250199 | VitalFlow Console | QNR | Substantially Equivalent | Medtronic, Inc. | accessdata.fda.gov |
| September 12, 2024 | K240880 | VitalFlow Set with Balance Biosurface | QJZ | Substantially Equivalent | Medtronic, Inc. | accessdata.fda.gov |
| October 4, 2023 | K232767 | Nautilus VF ECMO Oxygenator | BYS | Substantially Equivalent | Mc3, Inc. | accessdata.fda.gov |
| August 25, 2023 | K230364 | VitalFlow Console | QNR | Substantially Equivalent | Michigan Critical Care Consultants, Inc. (D.B.A Mc3 Inc.) | accessdata.fda.gov |
| August 25, 2023 | K223898 | VitalFlowTM Centrifugal Pump | QNR | Substantially Equivalent | Michigan Critical Care Consultants, Inc. (D.B.A Mc3 Inc.) | accessdata.fda.gov |
| May 3, 2021 | K203409 | MC3 Crescent Jugular Dual Lumen Catheter | PZS | Substantially Equivalent | Mc3, Inc. | accessdata.fda.gov |
| April 9, 2020 | K191935 | Nautilus Smart ECMO Module | BYS | Substantially Equivalent | Mc3 Incorporated | accessdata.fda.gov |
| October 29, 2018 | K182914 | MC3 Vascular Access Kit 21030 | DRE | Substantially Equivalent | Mc3 Incorporated | accessdata.fda.gov |
| July 16, 2018 | K180151 | MC3 Jugular Dual Lumen Catheter | PZS | Substantially Equivalent | Mc3 Incorporated | accessdata.fda.gov |
| February 27, 2014 | K132811 | SARNS SOFT-FLOW EXTENDED AORTIC CANNULA | DWF | Substantially Equivalent | Terumo Cardiovascular Systems Corporation | accessdata.fda.gov |
| February 18, 2014 | K132451 | SARNS SOFT-FLOW AORTIC CANNULA | DWF | Substantially Equivalent | Terumo Cardiovascular Systems Corp. | accessdata.fda.gov |
Recalls
Recall events where this establishment is the recalling firm, matched on its FEI.
| Initiated | Event | Class | Status | Product | Reason | Source |
|---|---|---|---|---|---|---|
| October 11, 2023 | 94016 | Class II | Ongoing | NautilusTM ECMO Oxygenator with Balance Biosurface-used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Product Number: (1) 48145; (2) 48145E | May have increased water path restriction within the heat exchanger, leading to degraded heat exchange performance during use. The reduction of water flow and reduced heat exchange performance may be experienced immediately upon priming or may worsen over the duration of use. The potential harm as stated in the IFU includes hypothermia due to inadequate heat | accessdata.fda.gov |
Compare with other makers
- All makers of Blood Pump For Ecmo, Long-Term (> 6 Hours) Use
- All makers of Extracorporeal System For Long-Term Respiratory / Cardiopulmonary Failure
- All makers of Oxygenator, Long Term Support Greater Than 6 Hours
- All makers of Tubing, Long Term Support Greater Than 6 Hours
- All makers of Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
- All makers of Dual Lumen Ecmo Cannula
Updated July 31, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.