LivaNova USA, Inc.: FDA-registered device maker in Houston, TX, United States, 1 510(k) clearance and 1 PMA approval

LivaNova USA, Inc. is registered with the FDA (registration 1644487) in Houston, TX, United States. It lists 4 device types. The FDA files 1 510(k) clearance and 1 PMA approval under its listings, the newest dated November 3, 2009. 29 recall events name it as the recalling firm (1 Class I). Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1644487
FEI number
1000117004
Address
100 Cyberonics BLVD., Houston, TX, United States, 77058
Owner or operator
LivaNova USA, Inc. (9002738)
Roles
Complaint file establishment, Manufacturer
First device listed
November 15, 2005
Registered through
2026
Brand names listed
Model 220, Patient Magnet, VAGUS NERVE STIMULATOR (VNS) SYSTEM, VNS THERAPY MODEL 402 TUNNELER

Devices it lists

DeviceProduct codeClassRoleSource
Instrument, Surgical, Non-PoweredHAO1Complaint file establishment, Manufactureraccessdata.fda.gov
Magnet, Test, PacemakerDTG1Complaint file establishment, Manufactureraccessdata.fda.gov
Stimulator, Autonomic Nerve, Implanted (Depression)MUZ3Complaint file establishment, Manufactureraccessdata.fda.gov
Stimulator, Autonomic Nerve, Implanted For EpilepsyLYJ3Complaint file establishment, Manufactureraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
November 3, 2009K092364MODEL 220 PATIENT MAGNETDTGSubstantially EquivalentCyberonics, Inc.accessdata.fda.gov

PMA approvals

Premarket approvals this establishment lists, with the supplements the FDA has decided since.

ApprovedPMA numberDeviceProduct codeSupplementsLatest decisionSource
July 16, 1997P970003VNS THERAPY SYSTEMLYJ238October 2, 2026accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
January 3, 202596063Class IIOngoingBrand Name: SenTiva" Product Name: VNS Therapy" SenTiva", Model 1000 Model/Catalog Number: 1000 Software Version: NA Product Description: The LivaNova VNS Therapy" System, used for Vagus Nerve Stimulation (VNS), consistsTheir is a potential that implanted pulse generators may stop delivering therapy due to an internal component issue.accessdata.fda.gov
December 12, 202495435Class IIOngoingSenTiva, REF: 1000; SenTiva Duo, REF: 1000-D; Generators Part of the VNS Therapy System. Used for Vagus Nerve Stimulation (VNS).Vagus nerve stimulator generators may stop delivering stimulation due to an internal, mechanically activated component that may become stuck in a closed position, which may result in patients returning to baseline seizure frequency or depressive symptoms and in the longer term, patients may be required to undergo generator replacement surgery to replace theiaccessdata.fda.gov
December 2, 202189335Class IITerminatedVagus Nerve Stimulation (VNS) Therapy Leads, PerenniaDURA, Model: 303. Model 303-20 PereniaDURA Lead (2.0 mm electrode inner diameter) and Model 303-30 PereniaDURA Lead (3.0 mm electrode inner diameter)A manufacturing issue may cause the silicone tubing wall thickness of vagus nerve stimulation leads to be less than the design specification. If the tubing becomes completely breached, the patient may experience discomfort or pain due to delivery of stimulation to an unintended location. If the inner lead conductor is exposed to body fluids the lead may breaaccessdata.fda.gov
November 12, 202086776Class IITerminatedVNS Therapy SENTIVA DUO # 1000-D - Product Usage: indicated for the treatment of chronic or recurrent depression in patients who are experiencing a treatment-resistant or treatment- intolerant depressive episode.During internal testing, it was found that upon a device reset, the Generator exhibits the incorrect Model Number when interrogated.accessdata.fda.gov
September 28, 202086570Class IITerminatedVNS Therapy AspireSR GeneratorDue to an extra digit being inadvertently added to the serial number of a subset of implantable pulse generators, they become not compatible with therapy programmers with software version 11.0.4.accessdata.fda.gov
February 4, 202084723Class IIOngoingVNS Therapy Programmer, Model 3000 used with Models 103, 104, 105, 106, or 8103 VNS Therapy generators.False positive warning may occur after: 1) VNS Generator interrogated at 0mA normal output current, 2) Generator programmed to non-0mA output current, 3) In-session re-interrogation performed. Users instructed to lower output current and widen pulse width. Only system diagnostic testing evaluates output current. Users may conclude device malfunction, could laccessdata.fda.gov
August 22, 201983873Class ITerminatedVNS Therapy, SenTiva, Model # 1000, (01)05425025750405, Rx Only for vagal nerve stimulation (VNS) therapySentiva generators may reset and become disabled within 60 days of enabling. Physicians can re-enable but devices will continue to be susceptible to resets. If a device experiences this issue, this may lead to additional surgery (premature replacement of generator), or patients may return to baseline seizure frequency or depressive symptoms due to cessation accessdata.fda.gov
August 13, 201984710Class IITerminatedVNS Therapy SENTIVA Generator Model # 1000 Labeling 26-0009-6800 Model 1000 Generator Sample Labels 26-0009-9600 Patient s Manual for Depression 26-0009-9500 Patient s Manual for Epilepsy 76-0000-5000 VNS Therapy System Firm identified a subset of its generators that were sterilized one additional sterilization cycle, which does not meet the firm's quality specifications.accessdata.fda.gov
November 16, 201884170Class IIOngoingVNS Therapy Program GMDN: 44077 Model # 3000 V1.5.2, RxOnlyThis recall is being initiated due to reports that that the therapy programming tablet with software version 1.5 errantly performs a normal mode diagnostic test instead of the selected system diagnostic test on Model 102 and Model 102R devices, if the output current is greater than 0.5mA. This can result in false high impedance values during patient follow-uaccessdata.fda.gov
November 16, 201884029Class IITerminatedCyberonics VNS Therapy AspireHC Model 105 Generator, 26-0007-4000/3. The firm name on the label is CYBERONICS, INC., Houston, TX. Vagus nerve stimulator.This recall is an expansion of Z-3019-2017 and Z-3020-2017, which was initiated to fix the devices premature battery depletion, caused by electrical leakage on the circuit board assemblies of the Models 105 and 106 generators. *Note this recall occurred in November 2018.accessdata.fda.gov
November 16, 201882566Class IIOngoingThe LivaNova VNS Therapy System, used for Vagus Nerve Stimulation (VNS), consists of an implantable VNS Therapy generator, lead, and external programming system used to change stimulation settings. The generator is an imLead impedance values reported by the affected VNS generator will be higher compared to those reported by previous models. This is due to a change in the timing of when affected VNS generator takes the lead impedance measurement during diagnostic testing. As a result, normal impedance ranges for the affected VNS generator have shifted relative to the existinaccessdata.fda.gov
January 24, 201880424Class IITerminatedVNS Therapy Programming System, Rx Only, Model 3000, v1.0.2.2Unintended warning message displayed on generators programmed with a Model 3000 v.1.0.2.2 programmer.accessdata.fda.gov
December 2, 201778914Class IITerminatedVNS(R) Therapy Programmer, GMDN: 44077, Model 3000 v1.0.2.2 Intended Use/Indications: United States Indications for Use: Epilepsy : The VNS Therapy System is indicated for use as an adjunctive therapy in reducing the freTwo Model 3000 Programmers were distributed in error by prior to FDA approval of version 1.0.2.2 software.accessdata.fda.gov
November 13, 201780062Class IITerminatedVNS Therapy Programmer, Model 3000, v1.0 SystemCertain Model 3000 programming events can result in miscalculation of parameters stored in the Models 103, 104, 105, and 106 generators. During these programming events, the miscalculations can lead to: " Delivery of more stimulation than intended, resulting in painful stimulation or other common side effects (Model 106 only); " No stimulation in the case ofaccessdata.fda.gov
June 13, 201777698Class IITerminatedVNS Therapy AspireHC Generator, VNS Therapy AspireSR Generator. Model No. 105. Product Usage: United States Indications for Use: Epilepsy (PMA 970003): The VNS Therapy System is indicated for use as an adjunctive therapyManufacturing process used to assemble the circuit board may result in some devices experiencing a faster than expected reduction in device longevity.accessdata.fda.gov
December 18, 201572896Class IITerminatedVNS Therapy AspireSR Generator Model 106. Indicated for use as an adjunctive therapy in reducing the frequency of seizures.Recall being initiated in response to three reports of "Burst Watchdog Timeout" events occurring with the Model 106 AspireSR Generator, resulting in a device reset condition where stimulation output is disabled.accessdata.fda.gov
November 18, 201572698Class IITerminatedCyberonics Vagus Nerve Stimulator VNS Therapy AspireSR Generator, Model 106Certain Model 106 Pulse Generators demonstrate delays in sensing during use of the 'Verify Heartbeat Detection' feature and exhibit the potential for decreased battery longevity.accessdata.fda.gov
October 7, 201572385Class IITerminatedCyberonics Vagus Nerve Stimulator (VNS) Therapy AspireSR Generator, Model 106Certain Model 106 Pulse Generators demonstrate delays in sensing during use of the 'Verify Heartbeat Detection' feature and exhibit potential for decreased battery longevity.accessdata.fda.gov
March 6, 201570804Class IITerminatedVNS Therapy DemiPulse Generator Model 103 and VNS Therapy DemiPulse Duo Generator Model 104; CYBERONICS, INC.The pulse generators have a lower battery longevity than specified in their design requirement as a result of the devices being inadvertently left in a programmed ON state during manufacture.accessdata.fda.gov
November 20, 201469844Class IITerminatedCyberonics VNS Therapy AspireHC, Model 105 Generator. The Cyberonics VNS Therapy System consists of the implantable VNS Therapy Generator, the VNS Therapy Lead, and the external programming system used to change the stimThe recalled product was distributed with an incorrect serial number printed on the device's label.accessdata.fda.gov
August 12, 201159818Not yet classifiedTerminatedVNS Therapy Aspire HC Generator and VNS, Model 105 Cyberonics, Inc. 100 Cyberonics Blvd., Houston, TX 77058 For implantation in humans to treat Epilepsy and Depression.The devices are being recalled because the output current delivered to the vagus nerve is less than the design intent and there is a potential charge imbalance at the lead cathode and generator-can during stimulation.accessdata.fda.gov
May 6, 201159139Not yet classifiedTerminatedVNS Therapy Demipulse Model 103 Generator Cyberonics, Inc. Houston, Texas, Model 103 Generators are provided in a sterile single use packages as part of the VNS Therapy System. Product labeling may be found at http://us.An investigation was initiated based on a report from the field in which an Intensive Follow-up Indicator (IFI) message was unexpectedly received by a medical professional when using Model 250 version 8.0 software to interrogate a patient's Model 103 Generator.accessdata.fda.gov
April 6, 201055446Not yet classifiedTerminatedVNS Therapy Demipulse Generator, Model 103 and VNS Therapy Demipulse Duo Generator, Model 104 VNS Therapy Programming System, Model 250 Version 7.0 and 7.1 SoftwareBattery life projection is inaccurate.accessdata.fda.gov
November 20, 200954020Not yet classifiedTerminatedVNS Therapy Demipulse Generator, Model 103 and VNS Therapy Demipulse Duo Generator, Model 104. The Cyberonics VNS Therapy system consists of an implantable VNS Therapy Generator, the VNS Therapy Lead, and the external prUnder certain conditions, product's battery life can be reduced.accessdata.fda.gov
July 24, 200953131Not yet classifiedTerminatedCyberonics VNS Therapy Programming M250 Programming System, model number 250, version 4.6, 6.1, 7.0 and 7.1. The Model 250 Handheld software is provided on flashcards packaged in software envelopes or pre-installed on haSome VNS Therapy System replacement Demipulse generators reporting low lead impedance readings. In rare instances, a system diagnostic test using Model 250 Programming Software (versions 7.1 and earlier) may report "Lead Impedance: OK" when a short-circuit condition exists.accessdata.fda.gov
February 7, 200847442Not yet classifiedTerminatedCyberonics VNS Therapy Demipulse Generator, Model 103; an implantable, multiprogrammable, vagus nerve stimulator.Reset/disabling of the VNS Therapy Demipulse Generator and Demipulse Duo Generator due to magnet interference resulting in the loss of stimulation.accessdata.fda.gov
October 25, 200745958Not yet classifiedTerminatedCyberonics, VNS Therapy System Model 250 Handheld programming system using Dell x5 handheld and preprogrammed with software v7.1 and higher; manufactured by Cyberonics, Inc., Houston, TX.Screen Freezes-- The Dell X5 Handheld PC screen will freeze caused due to incompatibility between the Microsoft 2002 OS and the model Dell X5 handheld computer. Once frozen, the handheld device becomes non-responsive to user input.accessdata.fda.gov
August 2, 200737912Not yet classifiedTerminatedCyberonics Neuro Cyberonics Prosthesis System NCP Bipolar Lead, Model #300; Sterile, Single use only; Distributed by Cyberonics, Inc., Houston, TX 77058.Dissolution/Fractures to the leads of the VNS Therapy Systemaccessdata.fda.gov
October 17, 200636672Not yet classifiedTerminatedCyberonics VNS Therapy System, Model 250-''HAND HELD'' programming software v6.1, v6.1.7, v7.0 and v7.1.3; manufactured by Cyberonics, Inc., Houston, TX.During programming, pulse generator may be inadvertently set to 8.0 mA output, regardless of the mA range selected by the clinicianaccessdata.fda.gov

Compare with other makers

Updated October 2, 2026. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.