Data / Medical devices / United States / Lacey Manufacturing Company LLC
Lacey Manufacturing Company LLC: FDA-registered device maker in Bridgeport, CT, United States, 5 510(k) clearances
Lacey Manufacturing Company LLC is registered with the FDA (registration 1218017) in Bridgeport, CT, United States. It lists 11 device types. The FDA files 5 510(k) clearances under its listings, the newest dated April 10, 2019. Registered through 2026. FDA data exported November 2, 2026.
SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.
- FDA registration number
- 1218017
- Address
- 1146 Barnum Ave, Bridgeport, CT, United States, 06610
- Owner or operator
- PARAGON MEDICAL, INC. (1218017)
- Roles
- Contract manufacturer, Manufacturer
- First device listed
- April 5, 2012
- Registered through
- 2026
- Brand names listed
- BEST Bipolar Forceps, Boston Endo Technologies
Devices it lists
| Device | Product code | Class | Role | Source |
|---|---|---|---|---|
| Electrosurgical, Cutting & Coagulation & Accessories | GEI | 2 | Contract manufacturer, Manufacturer | accessdata.fda.gov |
| Endoscopic Tissue Approximation Device | OCW | 2 | Contract manufacturer | accessdata.fda.gov |
| Instrument, Ligature Passing And Knot Tying | HCF | 1 | Contract manufacturer | accessdata.fda.gov |
| Knife, Orthopedic | HTS | 1 | Manufacturer | accessdata.fda.gov |
| Light, Surgical, Fiberoptic | FST | 2 | Contract manufacturer | accessdata.fda.gov |
| Neurosurgical Nerve Locator | PDQ | 2 | Manufacturer | accessdata.fda.gov |
| Orthopedic Manual Surgical Instrument | LXH | 1 | Manufacturer | accessdata.fda.gov |
| Orthopedic Stereotaxic Instrument | OLO | 2 | Manufacturer | accessdata.fda.gov |
| Plate, Fixation, Bone | HRS | 2 | Contract manufacturer | accessdata.fda.gov |
| Staple, Implantable | GDW | 2 | Contract manufacturer | accessdata.fda.gov |
| Stimulator, Nerve | ETN | 2 | Contract manufacturer | accessdata.fda.gov |
510(k) clearances
The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.
| Decided | 510(k) number | Device | Product code | Decision | Applicant | Source |
|---|---|---|---|---|---|---|
| April 10, 2019 | K182662 | NAV PAK Needle, NIM NAV PAK Needle | PDQ | Substantially Equivalent | Boston Endo Surgical Tech, | accessdata.fda.gov |
| August 22, 2018 | K180542 | NIM PAK Needle; NIM XPAK Needle; NIM Pedicle Probe | PDQ | Substantially Equivalent | Boston Endo Surgical Tech, | accessdata.fda.gov |
| October 25, 2013 | K131058 | BIPOLAR FORCEPS | GEI | Substantially Equivalent | Boston Endo-Surgical Technologies, Inc. | accessdata.fda.gov |
| August 23, 1994 | K940750 | INNERVISION,INC. LAPAROSCOPIC ELECTRODES | GEI | Substantially Equivalent | Innervision, Inc. | accessdata.fda.gov |
| June 13, 1994 | K936304 | ELECTROSURGICAL PENCIL | GEI | Substantially Equivalent | E & M Engineering, Inc. | accessdata.fda.gov |
Compare with other makers
- All makers of Neurosurgical Nerve Locator
- All makers of Orthopedic Stereotaxic Instrument
- All makers of Plate, Fixation, Bone
- All makers of Electrosurgical, Cutting & Coagulation & Accessories
- All makers of Staple, Implantable
- All makers of Orthopedic Manual Surgical Instrument
Updated April 10, 2019. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.