Skip to the page

Data / Medical devices / United States / JAS Diagnostics/Drew Scientific

JAS Diagnostics/Drew Scientific: FDA-registered device maker in Plantation, FL, United States, 5 510(k) clearances

JAS Diagnostics/Drew Scientific is registered with the FDA (registration 1064608) in Plantation, FL, United States. It lists 9 device types. The FDA files 5 510(k) clearances under its listings, the newest dated December 11, 2007. 6 recall events name it as the recalling firm. Registered through 2026. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
1064608
FEI number
3003071743
Address
6600 NW 14th Street BAY 12, Plantation, FL, United States, 33313
Owner or operator
JAS Diagnostics/Drew Scientific (9042128)
Roles
Manufacturer, Repackager or relabeler, Specification developer
First device listed
January 18, 2013
Registered through
2026
Brand names listed
D3 Hematology Analyzer Model D3, Differential Lyse (20L); Drew 3 Reagent Pac; Drew-3 Lytic Reagent; EX-Lyse; EX-PAC2, Drew-3 Enzymatic Cleaner; E-Z Clean, EX-Ezyme, Drew Hematology Clean, Drew-3 Hematology Diluent; EX-ISO Hematology Diluent, EX-CAL Hematology Calibrator, EX-Trol Controls (Low, Normal, High), EX-Trol Plus Controls (Low, Normal, High)

Devices it lists

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
December 11, 2007K071562D3 HEMATOLOGY ANALYZER, MODEL D3GKZSubstantially EquivalentDrew Scientific, Inc.accessdata.fda.gov
July 10, 2006K061511R&D CBC-3D + CRP HEMATOLOGY CONTROLJPKSubstantially EquivalentR&D Systems, Inc.accessdata.fda.gov
January 16, 2001K003991CD-CAL PLUS CALIBRATORKRXSubstantially EquivalentR&D Systems, Inc.accessdata.fda.gov
January 12, 2001K003874CBC-4K HEMATOLOGY CONTROLJPKSubstantially EquivalentR&D Systems, Inc.accessdata.fda.gov
September 20, 1995K952720AALTO SCIENTIFIC LTD. GLYCATED HEMOGLOBIN CONTROL LEVELS I & IIJPKSubstantially EquivalentAalto Scientific, Ltd.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
April 21, 201777464Class IITerminatedDrew Scientific DREW 3-PAC Reagent Kit containing: 5L Diluent, 750 mL Enzymatic Cleaner, and 125 mL Lysing Reagent.May result in elevated platelet backgrounds during routine startup/background checks.accessdata.fda.gov
March 10, 201673650Class IITerminatedDrew Scientific Inc. Drew3-PAC. This D3 Reagent Pack includes: diluent reagent 5L, enzymatic cleaner 750 mL, and a lysing reagent 125 mL.The reagent pack may result in elevated platelet background during Drew3 Hematology Analyzer routine check.accessdata.fda.gov
October 23, 201469622Class IITerminatedGlucose Hexokinase (Liquid) Reagent For the in vitro quantitative determination of Glucose in serum.Product is not performing according to specifications. Control 2 does not consistently recover within its assigned range.accessdata.fda.gov
April 7, 201468343Class IITerminatedGlucose Hexokinase Liquid Reagent For the in vitro quantitative determination of Glucose in serum.JAS Diagnostics, Inc. of Miami Lakes, FL is recalling their Glucose Hexokinase reagent due to certain lots not performing according to their specifications.accessdata.fda.gov
September 20, 200636728Not yet classifiedTerminatedBayer Advia 70 Hematology Analyzer, manufactured by Drew Scientific, Inc., Dallas, TX.System has given inaccurate readings when running samples that trigger an extra rinse due to very high WBC, RBC or Platlet counts.accessdata.fda.gov
August 24, 200636706Not yet classifiedTerminatedBayer Advia 70 Hematology Analyzer, manufactured by Drew Scientific, Inc., Dallas, TX.Flags and alerts on the user interface will not automatically transfering to the LIS.accessdata.fda.gov

Compare with other makers

Updated December 11, 2007. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.