Integrated Orbital Implants, Inc.: FDA-registered device maker in San Diego, CA, United States, 3 510(k) clearances

Integrated Orbital Implants, Inc. is registered with the FDA (registration 2027377) in San Diego, CA, United States. It lists 5 device types. The FDA files 3 510(k) clearances under its listings, the newest dated December 28, 1998. 4 recall events name it as the recalling firm. Registered through 2027. FDA data exported November 2, 2026.

SpecStream is the live web data engine for teams and agents. It reads the FDA registration and listing, 510(k), PMA, recall and enforcement files from openFDA every week, and this page is that reading, joined by the FDA's own numbers. Ask for the makers of any device type in any country and new clearances, approvals and recalls arrive in your sheet, CRM, Slack or agent as the FDA publishes them.

FDA registration number
2027377
FEI number
3009688114
Address
11230 Sorrento Valley Rd Ste 135, San Diego, CA, United States, 92121
Owner or operator
INTEGRATED ORBITAL IMPLANTS INC (2027377)
Roles
Repackager or relabeler, Specification developer
First device listed
December 11, 2006
Registered through
2027
Brand names listed
IMPLANT, EYE SPHERE, Needle, ophthalmic suturing, OCULAR PEG, Sterile Bio-eye Ha implant & conf., THREADED SLEEVE DRIVER, THREADED SLEEVE WRENCH

Devices it lists

DeviceProduct codeClassRoleSource
Conformer, OphthalmicHQN2Repackager or relabeler, Specification developeraccessdata.fda.gov
Implant, Eye SphereHPZ2Repackager or relabeler, Specification developeraccessdata.fda.gov
Needle, Ophthalmic SuturingHNM1Repackager or relabeler, Specification developeraccessdata.fda.gov
Ocular PegMQU2Repackager or relabeler, Specification developeraccessdata.fda.gov
Screwdriver, SurgicalLRZ1Repackager or relabeler, Specification developeraccessdata.fda.gov

510(k) clearances

The 510(k) numbers this establishment lists, with the FDA decision on each. The applicant is the company that holds the clearance.

Decided510(k) numberDeviceProduct codeDecisionApplicantSource
December 28, 1998K982562BIO-EYE HYDROXYAPATITE OCULAR IMPLAND AND CONFORMERHPZSubstantially EquivalentIntegrated Orbital Implants, Inc.accessdata.fda.gov
February 4, 1998K974203PERRY-KOLBERG (PK) TITANIUM MOTILITY/SUPPORT SYSTEMMQUSubstantially EquivalentIntegrated Orbital Implants, Inc.accessdata.fda.gov
August 24, 1989K891137MOTILITY ORBITAL IMPLANTHPZSubstantially EquivalentIntegrated Orbital Implants, Inc.accessdata.fda.gov

Recalls

Recall events where this establishment is the recalling firm, matched on its FEI.

InitiatedEventClassStatusProductReasonSource
May 20, 201158877Not yet classifiedTerminatedProduct Brand Name: Coated Bio-Eye Orbital Implant w/Conformer. Product Generic Name: Implant, Eye Sphere Wrap, Implant, Orbital. Model Number: I0016C, I0018C, I0020C, I0022C, I0024C. Description of the product: The CoatThe recall was initiated because Integrated Orbital Implants has confirmed certain lots of the Coated Bio-Eye were manufactured without expiration dating visible on the packaging. All unlabeled product is currently beyond its expiration date.accessdata.fda.gov
June 7, 201056329Not yet classifiedTerminatedSterile Bio-Eye Hydroxyapatite Orbital Implant and ConformerIntegrated Orbital Implants, Inc. has initiated a recall of it's Sterile Bio-Eye Hydroxyapatite Orbital Implant and Conformer due to a labeling issue in which the expiration date of the product was omitted.accessdata.fda.gov
December 20, 200637139Not yet classifiedTerminatedPerry-Kolberg Titanium Motility/Support System (Threaded Sleeve and Flat Peg), Model Number 100045 The threaded sleeve and flat peg are two components of the P-K Titanium Motility/Support System. The threaded sleeve is aThe threads on the threaded sleeve were manufactured with left-handed threads, requiring a modification to the surgical technique for proper insertion. Failure to properly identify the affected components and apply the modified insertion technique will result in an inability to insert the sleeve into the implant.accessdata.fda.gov
February 27, 200636298Not yet classifiedTerminatedBio-Eye Hydroxyapatite (HA) Orbital Implant and Conformer, Model Number: 100020SThe end label on the outer box was mislabeled on 9 of a 10 unit lot. The end label says ''22 mm'' and the implants are actually ''20 mm''. The main label on the cardboard box applied by the contract packager is correct in identifying the product as ''20 mm''.accessdata.fda.gov

Compare with other makers

Updated June 22, 2011. Read from openFDA bulk downloads (device registration and listing, 510(k), PMA, recall and enforcement files). CC0 1.0, public domain (openFDA terms of service). The files are joined on FDA identifiers: the 510(k) and PMA numbers a registration lists, and the recalling firm's FEI for recalls. Recall class comes from the FDA enforcement report. The FDA states that openFDA data is unvalidated and is not for decisions about medical care. Free to reuse with credit to SpecStream under CC BY 4.0. Spot a wrong value? Write to [email protected] with the link to this page.